Вы находитесь на странице: 1из 7

Automotive Electronics Product Information Lambda Probe Interface IC - CJ120/125

Integrated circuit for continuous lambda regulation with Ri measurement

Features  Pump current control with hold function and shut off for regulation of nernst cell at 450mV  Pump current sense amplifier with switchable amplification and adjustment  lambda output amplifier  Virtual ground voltage source for sensor and pump current control  Nernst cell reference voltage source (450mV, reference to virtual ground)  Offset adjust control  Diagnosis circuit  Oscillator / generation for timing  Ri measurement and calibration with S&H and Ri differential amplifier  SPI (only slave mode) for initialization, identification and transfer of diagnosis information Features only CJ125  Programmable reference pumping current (4 bits)  Suppression of parasitic interference of heater clock with Ri measurement

Customer benefits:  Excellent system know-how  Smart concepts for system safety  Secured supply  Long- term availability of manufacturing processes and products  QS9000 and ISO/TS16949 certified

The integrated circuit CJ120/CJ125 is a control and amplifier circuit for a wide range -Sensor LSU4.x for the continuous regulation of in combination with the sensor in the range of = 0.65... (air).

Block diagram

Application example (only proposal!)

The application circuit of the CJ120/125 consists of the following parts :  Capacitor between [VCC] and [GND] to stabilize the supply voltage VCC  Capacitor between [UB] and [GND] to stabilize the supply voltage VUB  Capacitor between [CF] and [GND] to filter the lambda signal  Capacitor between [UA] and [GND] to stabilize lambda signal output  Capacitor between [UN] and [GND] to stabilize nernst signal  Capacitor between [/RST] and [GND] to stabilize reset signal  Shunt between [IA] and [IP] for pump current sensing  Resistor between [IA] and [UP] to compensate parasitic effects of the lambda sensor  Resistor between [US] and [UP] to feed the nernst cell reference voltage into the pump current control circuit  Resistor between [UP] and [UN] for leakage detection  Resistor between [RF] and [CF] to filter the lambda signal  Capacitor between [UR] and [GND] to stabilize the output signal for ADC  Capacitor between [UN] and [GND] for filtering  Resistor between [RM] and capacitor at [CM] for adjustment of Ri measurement current  Capacitor between [CM] and resistance at [RM] for dc filtering.  Resistor between [RS] and [VM] for adjustment  Resistor between [UN] and [VCC] only for LSU-4.9  Resistor between [DIAHD] and Drain of the external heater  Resistor and capacitor before [UN] for filtering

Pin description Pin


UB VCC,VCCS a.) GND, GNDS b.) VM US IP IA RF CF UA UP UN RM CM RS UR DIAHG DIAHD SCK SI SO

Description
Power supply input (14V) Power supply input (5V) Ground Virtual ground of pump current control and of the LSU (0.5VCC) Nernst cell reference voltage (450mV) Inverting input of pump current amplifier (shunt voltage) Non inverting input of pump current amplifier and output of the pump current control Output of pump current amplifier (--> external filter) Input of lambda output amplifier (after external filter) Output of lambda output amplifier Non inverting input of pump current control Inverting input of pump current control respective in-/output for Ri-measurement (LSU) Output Ri-measurement current (DC) Input Ri-measurement current (AC, DC free) In-/output Ri-calibration measurement Output Ri-signal (analogous) Diagnosis input (gate of external transistor) Diagnosis input (drain of external transistor) Input SPI-clock (from C) Input serial data (SPI, from C) Output serial data (SPI, to C) Slave select (SPI, from C) Input Reset Rextern= 10k

PIN configuration

/SS /RST OSZ


a.)

For hybrid version it is recommended to connect VVCS with the reference VCC for the ADC b.) For hybrid version it is recommended to connect GNDS with the reference ground for the ADC

Maximum ratings Parameter


Supply voltage UB Supply voltage VCC Temperature Maximum allowed voltages valid for pins: RM, UP, US,RF, CF, UA, UR, DIAHG, DIAHD; SCK, SI, SO, /SS, /RST, OSZ Allowed current Maximum allowed voltages, no destruction when ISO-pulses 3a,b are applied. Valid for board pins: RS, UN, VM, IA, IP, CM Offset between GND and GNDS Offset between VCC and VCCS ESD Ext. resistor 6.8 k Junction Storage Ambient

Condition

Symbol
VUB VVCC TJ TST TA VX

Min.
-0.3 -0.3 -40 -40 -40 -0.3

Max.
35 5.5 150 150 125 VVCC+0.3

Unit
V V C C C V

IDIAHD VX

-1 -0.3

10 28

mA V

VGND VVCC Human body model R= 1.5k, C= 100pF

-0.1 -0.1 -2

0.1 0.1 2

V V kV

Electrical characteristics Parameter


Power supply Power supply operating range Current consumption Current consumption Pump current control Offset voltage Input current Input offset current VGND = VGNDS VVCC = VVCCS VUB VVCC IVCC IVCCS 9 4.75 18 5.25 75 4 10 1 1 30 30 10 1 17.24 8.15 12 0.20 0.285 -3 VVCC -0.18 0.315 3 V V mA mA mV A A mA mA A A

Condition

Symbol

Min.

Max.

Unit

Voff -40C Tj < 150C IUP, UN -40C Tj < 150C Ioff VUN < VUP; PA = 1; Output current source condition -IIA 0.5V < VIA < VCC-0.5V VUN > VUP; PA = 1; Output current sink condition IIA 0.6V < VIA < VCC-0.5V No output current PA = 0 IIA Pump current sense amplifier (LA = 0: measurement mode; LA = 1: adjustment mode) Input current -40C Tj < 150C IIP Amplification SPI-bit VL = 1 A0 Amplification SPI-bit VL = 0 A0 CMRR-1= VUA/ VIP VIP= VIA= 1...4V Common mode rejection ratio CMRR-1 0.5V < VUA< VCC-0.5V |IUA| < 10A Output voltage swing |IUA| < 10A; LA = 0 VUA Output voltage adjustement IRF=0A; LA = 1 VRF / VVCC VUA= VUA(LA = 1) - VUA(LA = 0) Output error offset adjust VUA VIP= VIA= VVM |IUA| < 10A

-10 -1 -1 10 10 -10 -1 16.64 7.85

mV/V V

mV

Parameter
Virtual ground voltage source Output current operating range Output voltage ratio

Condition

Symbol
IVM

Min.
-IIA - 2 0.48

Max.
-IIA + 2 0.52

Unit
mA

-IIA-1mA < IVM < IIA+1mA

VVM / VVCC

Nernst cell reference voltage source Output current operating range IUS Oscillator Frequency f external 10k Measurement current for Ri (RA = 0 measurement mode; RA =1 adjustment mode) Output resistor of push-pull-stage -1mA IRM 1mA R Ri amplifier Leakage current when switch is open ILeak Amplification A0 Ron for a switch Ron Input voltage range at CM, UN and RS VRI Output voltage range VUR Zero point for output trace VUR/ VVCC Pump reference current programmable with Current range - IUn SPI-bits PRx; x = 0 to 3 Diagnosis of sensor lines Short circuit to ground VVM/ VVCC Short circuit to Vbat VVM/ VVCC Short circuit to ground VUN/ VVCC Short circuit to Vbat VUN/ VVCC Short circuit to ground VIA,IP Short circuit to Vbat VIA Diagnosis of external heater Low level VDIAHG High level VDIAHG Pull up current - IDIAHG Short circuit to ground DIAHG = low IDIAHD Short circuit to Vbat DIAHG = high IDIAHD Open load DIAHG = low IDIAHD No failure DIAHG = high IDIAHD No failure DIAHG = low IDIAHD Filter time T=1/f tDIAG / T SPI Data rate Bit-frame Number of read / write commands Number of register

-0.4 2.49 5 -500 15 2 0.06 VVCC 0.05

0.4 3.51 100 500 16.3 100 VVCC- 1.1 VVCC- 0.2 0.063

mA kHz nA V V

150

0.35 0.55 0.35 0.55 0.3 VVCC - 0.3 0.7 VVCC 10 - 350 - 100 - 100 - 1 000 350 15 / 32

0.45 0.65 0.45 0.65 1.5 VVCC+ 2 0.3 VVCC VVCC+ 0.3 50 - 100 10 000 100 - 350 10 000 16 / 32 2 16 6 4

V V V A A A A A A

Mbaud bit

SPI

Block schematic, register, RD / WR-commands with hec-code

Failure bits
00 01 10 11
d.)

a.)

Ext. heater
Short circuit to ground Open load Short circuit to Vbat No failure

Sensor b.)
Short circuit to ground Low battery c.) Short circuit to Vbat No failure

a.)

Each failure leads to a switch off of pump current and virtual ground Failure identification at UN must be enabled with ENSCUN Open load is not recognizable; bits used for low battery After RD_DIAG or if no failure is present; Failure bits will be restored if failure is still present

b.) c.) d.)

Timing

Read access

Write access

v: command valid/not valid dc: dont care (-) x: 0 or 1 Z: tristate

Contact
Robert Bosch GmbH Sales Semiconductors Postbox 13 42 72703 Reutlingen Germany Tel.: +49 7121 35-2979 Fax: +49 7121 35-2170 Robert Bosch Corporation Component Sales 38000 Hills Tech Drive Farmington Hills, MI 48331 USA Tel.: +1 248 876-7441 Fax: +1 248 848-2818 Robert Bosch K.K. Component Sales 9-1, Ushikubo 3-chome Tsuzuki-ku, Yokohama 224 Japan Tel.: +81 45 9 12-83 01 Fax: +81 45 9 12-95 73 Internet: www.bosch-semiconductors.de

E-Mail: bosch.semiconductors@de.bosch.com

04/2006 All rights reserved by Robert Bosch GmbH including the right to file industrial property rights Robert Bosch GmbH retains the sole powers of distribution, such as reproduction, copying and distribution. For any use of products outside the released application, specified environments or installation conditions no warranty shall apply and Bosch shall not be liable for such products or any damage caused by such products.