Вы находитесь на странице: 1из 45

rvic

M nual
Wall split type

Table of Contents
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.

Summary .............................................. .3 Model explaining . ............................................. .4 Use and installation ............................... .4 Exploded view and part list.............................................. 20 Operation principle. ................................................ 28 Parameter. ................................................ 28 Wiring diagrams. .................................................. 30 PCB principle chart................................................. 32 Part list of PCB ..................................................... 32 PCB function . .......................................... 34 Troubleshooting. ........................... 40

1. Summary
1.1 indoor unit

Model 48

1.2 outdoor unit

9000BTU
model indoor unit Net Dimension outdoor unit 700225500 CQS-25H3A-G48AY1 790270180

12000BTU
CQS-35H3A-A48AH1 790270180 795255540

2Model explaining
c
Improve an ordinal number Divide the body outdoors box a body code External appearance characteristic code Separately the body indoor machine(or whole type) style code Separately the body pit code inside the indoor machine(or whole type) Code of refrigerant type no code - R22 C-R407c A-R410a Power type 1:115v/60Hz 2:220V/60Hz 3:220-240V/ 50Hz 4:240V/50Hz Main function code: c-Cold breeze type;H-Hot pump type;A-Hot pump the type take assistance electricity to heat;E-The electricity heat Capacity code: x1000W Structure form code Special craft code:Q-Deal with contact quickly;S-Soft start;dOutside tube in addition to frost The weather type code(T1 type code abridge)

"C" CHIGO brand


as: CQS-25H3A-G48AY1 T1 climate type,deal with contact quickly ,hot pump type, wall split type air conditioner, cooling capacity is 2500Wpower is 220-240V/50Hz/1PHrefrigeration is R410A,the kernel of indoor unit is 418the pattern no. is 48first time design, outdoor unit is 1HP of 2003 year Indoor unit modle isCQS-25H3A-G48Aoutdoor unit model isCQS-25H3A-Y1

3. Use and installation .


BASIC ACCESSORIES
This Installation section explains how and where to connect this new air conditioner. Please read make sure all accessories are included as shown below and read manual thoroughly. This Installation section is provided to assist the per-son knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar with this type of installation. Please contact a professional installer if necessary.

ACCESSORIES SUPPLIED WITH THE UNIT:


No 1 2 Part Name Remote Controller Remote Holder Q'ty 1 1 Remark No 3 Part Name Battery Q'ty 2 Remark

Before installation: Selection of installation positions for indoor unit


To be installed at the position where the air delivered from the unit can reach every corner of the room Avoid to biockage the air inlet or outlet of the indoor nit To avoid too much oil smoke or steam Avoid possible generation infiow, lingering or leakage of flamm gasee Avoid high-frequency facilities (such as high frequency arc welders etc.) Not to install a fire alarm near the air outlet. To avoid the places where acid solutions are frequently used

[Selection of installation positions for indoor unit]


To be installed at the position where the air delivered from the unit can reach every comer of the room; To avoid being affected by the outdoor air; To avoid blockage to the air inlet or outlet of the unit; To avoid too much oil smoke or steam; To avoid possible generation,inflow,lingering or leakage of flammable gases; To avoid high-frequency facilities(such as high frequency arc welders,etc,) To avoid the places where acid solutions are frequenty used; To avoid the places where some special sprayers(sulfides) are frequently used Not to install on top of the musical instruments,TV,computer etc,valuable appliance. Not to install a fore alarmning device near the air outlet of the unit(during operation,the fire alarm device might be erroneously triggered by the warm air from the unit);

Make sure of enough space for installation and maintenance


To take into consideration the operational convenience and safety in installation,it is recommended ti ensure enough space between the unit and the walls,

Attention:lf

there are some additional function devices to install on the air conditioner,Besure add to the installation space for the function devices

Height limits of indoor and outdoor units Either the indoor unit or the outdoor unit can be higher,but the height difference must comply the stated requirements Try to reduce the bending of the piping line as much as possible so as to avoid possidle negative impacts upon the performnances of the units

[Selection of installation positions rot outdoor unit]


To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises; To install the unit at the places not to exposed to rain or direct sunshine,and the places with good ventilation; The noises generated from the unit will not affect the neighboring places; Do not install the unit on non-metal frame; Not to install the unit at the places where there might occur the generation,inflow,stay or leakage of inflammable gases; pay attention to the drainage of the condensed water from the base plate during operations; To avoid the air outlet being directly against the wind.

Detailed space requirements around the outdoor unit

[lnstallation fixture of indoor unit]

4Indoor outside explosion the diagram and spare parts catalogue


4.1 CQS-25H3A-G48AY1 4.1.1 Explosive view of indoor unit

4.1.2 Spare parts list of indoor unit


No. 1 2 3 4 5 6 7 8 9 10 Louver Outlet part Left angle plate Base Cross flow fan Fan Bearing Connecting Cable Quick coonector Evaporator assembly Evaporator left fixed plate Description Part No. CQS-25H3A-G48AY1 100420003/100420083 391200006 100360001 100060106 100010016 2 1 1 1 1 1 1 1 1 1

Qty

110010603 342300055
979900183 972900618 109990108

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

Screw cover Middle frame Air Filter Display box cover Disp;ay box Front Panel Remote controller
Roomtemp.Sensor Holder

109990023 391070007 100190111 . 100410004 391022065 336815006 100280105 100430025 100420002 109990109 100130003 030020173 391110017 050010042 030090005

2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Pipe Clamp Eliminator


Evapora torright fixed plate

Motor platen Motor Wire Clip Power Cord


Terminal Board

Display lamp panel Tube Temp.Sensor Electric control plate Room Temp.Sensor Electric box Transformer Connecting Wire Base right angle plate Wall-mounting frame Step motor Step Motor plate Crank connecting rod

331800039 079990030 331300107 049990012


100100035

030180061
120310028 100300003 020100010 320273001 320273001 100420082

4.1.3 Explosive view of outdoor unit for 1HP

4.1.4 Spare parts list of outdoor unit


No. 1 2

Description
Front Grill Grill Clip

Part No.

Qty
1 8

CQS-25H3A-G48AY1
020120002 109990256

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

Front Plate Small handle Nut Gasket Axial flow fan Motor Motor support PE Sponge Base Anti-vibration pad for the compressor Compressor Nut Gasket Nut Top panel PU Sponge Partition board Electric installation board Compressor Capacitor Capacitor Clamp Fan Capacitor Terminal Board Wire Clip PU Sponge Condenser tube temp. sensor wire Copper pipe or sensor Capillary Assy Damping rubber Drainpipe for the condensor Intake pipe for the condensor 4-way Valve Discharge pipe Damping block Damping rubber Suction pipe Quick connector 1 Quick connector 2 Low-pressure Connecting Pipe High-pressure Connecting Pipe Filling valve Valve installation plate Large handle

020070001 100050001 150020009 150030013 100030013 030020201 313040004 090020234 020010129 010011455 302114004 010011578 010011456 150020003 020080001 090020226 020030001 020130006 030010015 020140006 030010005 030090025 321100011 090020227 372100103

1 1 1 1 1 1 1 1 1 3 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1

PE 1 2

338000008
079990030 971900314 110030023 360510003 360440093 973500175 360220111 110020011 110030017 360120107 351600014 351600014 979900184

42 43 44 45

361300062 359000004 313020016 100040001

1 1 1 1

46 47 48 49 50

Right panel Connecting Wire Connecting Cable Electric heater Electric heating wire clip

313060035 425300038 342300046 320440005 313990014

1 1 1 1 4

4.2 CQS-35H3A-A48AH1
4.2.1 Explosive view of indoor unit

4.2.2 Spare parts list of indoor unit


No. 1 2 3 4 5 6 Louver A Louver B Swing Louver Connecting rod Guide Louver Bearing Outlet part Description Part No.

CQS-35H3A-A48AH1
100420003 100420083 100420007 100420072 100420008 100090110

Qty
1 1 12 3 6 1

7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52

Left angle plate Base Cross flow fan Cross flow fan bearing Fan Bearing Connecting Cable Quick connector Evaporator assembly Evaporator left fixed plate Remote controller Screw cover Middle frame Front Clip Air Filter Cold Catalyst Display box cover Display box Front Panel Middle frame coverplate
Room temp. Sensor Holder Insert Block Copper pipe of sensor

100360001 100060108 100010016 110010603 342300097 979900178 972901480 109990108 336815006 109990023 391070007 391220004 100190127 119990011 100410004 100410004 391022065 100080034 100280105 079990240 079990030 100430025 109990109 100130003 030020173

1 1 1 1 1 1 1 1 1 1 2 1 4 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1

Pipe Clamp
Evaporator right fixed plate

Motor platen Motor Electric box cover Display lamp plate Tube Temp. Sensor Room Temp. Sensor Electric control plate Connecting Wire Transformer Electric box Wire Clip Terminal Board Power Cord Right angle plate Wall-mounting frame Screw Step motor Motor fixed plate Crank connecting rod Upper crank Lower crank Thermal insulation pipe

100100041 331800039 079990030 049990012 331300009 425300063


030180061 100100035 391110018

030090005
050010050 100300003 020100010

150010019
320273001

100420002
100420082 100420001 100420081 099990080

4.2.3 Explosive view of outdoor unit for 1.5HP

4.2.4 Spare parts list of outdoor unit


No. 1 2

Description
Front Grill Grill Clip

Part No.

Qty
1 8

CQS-35H3A-A48AH1
020120015 109990256

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Front Plate Small handle Nut Gasket Axial flow fan Motor Motor support PE Sponge Base Anti-vibration pad for the compressor Compressor Gasket Nut Top panel Partition board PU Sponge Electric installation board Compressor Capacitor Capacitor Clamp Terminal Board Fan Capacitor Wire Clip PU Sponge Condenser Tube temp.sensor wire Copper pipe or sensor 4-way Valve Intake pipe for the condensor Capillary Assy Damping rubber Filter Right panel Large handle Quick connector 1 Quick connector 2 Connecting Cable Low-pressure Connecting Pipe High-pressure Connecting Pipe Filling valve Valve installation plate Drainpipe for the condensor Discharge pipe Damping block

020070056 100050021 150020009 150030018 393010001 320222005 313040002 090020234 313011093 305146005 302114009 305142002 305143002 020080002 313030014 090020027 020130006 030010017 020140006 321000025 030010005 321100003 090020028 372100086 338000008 079990030 973500062 360450021 971900295 110030017 361910002 020060041 100040002 351600014 351600014 342300045 979900176

1 1 1 1 1 1 1 1 1 3 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

PE 1 2

40 41 42 43 44 45

361300062 359000004 020020008 360540042 360220103 110020011

1 1 1 1 1 1

46 47 48 49 50

Suction pipe Damping rubber Connecting Wire Electric heater Electric heating wire

360130149 110030023 425300038

1 2 1 1 4

320440005
313990014

5. Operation principle
indoor unit
10 11 9

indoor fan

connection pipe 12

connection pipe

2 15

outdoor unit
1 5 13 14 3 16 4

outdoor fan

pay attention to sealing cooling heating


4.flow divider for condenser 9.flow divider for evaporator 5.Non-return valve 10.evaporator 6.auxiliary capillary 16pipe

1.compressor evaporator

2. 4-way value

3.condenser

7.cooling capillary

8.high-pressure valve

11. pipe temp. sensor for

12.low-pressure valve

13.Vapor liquid separator

14.low-pressure switch

15. high-pressure switch

temp. sensor for condenser Cooling cycly compressor4-way valuecondenserflow divider for condenserNon-return valvecooling capillary high-pressure valveflow divider for evaporatorevaporatorlow-pressure valve4-way valueVapor liquid separator compressor. Heating cyclycompressor4-way valuelow-pressure valveevaporatorflow divider for evaporatorhigh-pressure valve cooling capillaryauxiliary capillaryflow divider for condensercondenser4-way valueVapor liquid separator compressor. NoteTo the model of RF or LF beginning, use outdoor unit model to express the whole unit.

6. Parameter Performance parameter


Model pattern Power supply Cooling Cooling capacity NO.
Ph-V-Hz

CQS-25H3A-G48AY1 48 220-240V/50Hz 2780

CQS-35H3A-A48AH1A 48 220-240V/50Hz 3590

Cooling Input Cooling Rated current EER Heating Capacity Heating Heating Input Heating Rated current COP Max. input consumption Max. current Model Type Brand Compressor Capacity Input Start electric current Thermal protector Capacitor Model Fan motor Indoor unit Input Capacitor Speed Fan motor diameterheight Air flow Noise level Net Dimension (W*H*D) Packing Dimension (W*H*D) Net/Gross weight Model Fan motor Outdoor uni Input Capacitor Speed Fan motor diameterheight Noise level Net Dimension (W*H*D) Packing Dimension (W*H*D) Net/Gross weight Refrigerant type

W A w/w. W W A w/w. W A

865 4.0 3.21 2780 770 3.5 3.61 1660 8.2 PA108X1C-4DZDE ROTARY TOSHIBA

1120 5.1 3.21 3680 1020 4.7 3.61 2170 10.6 PA140X2C-4FT ROTARY TOSHIBA 3365/3385 1160/1200 2601 inner 35 YDK-16-4 47 1.2 1350 93633 600 35-42 790*270*180 875*345*340 12/14 YDK-35-6A H 67 2 900 401115 54 795*255*540 920*335*585 36/40 R410A/1020g

W W A uF W uF r/min mm m3/h dB(A) mm mm Kg W uF r/min mm dB(A) mm mm Kg g

2570/2670 885/915 21.7 inner 25 YDK-16-4 47 1.2 1350 93633 500 29-39 790*270*180 875*345*340 12/14 YDK-30-6 85 2 890 384136 49 700*225*500 825320535 30/32 R410A/610g

7.Wiring diagrams
7.1 CQS-25H3A-G48AY1 Indoor unit:

Outdoor unit:

7.2 CQS-35H3A-A48AH1 Indoor unit:

Outdoor unit:

8.PCB principle chart(CQS-25H3A-G48AY1/CQS-35H3A-A48AH1)


1 2
CNB
N1

6
220UF /16V E2

D5 E1 U F U SE

C1 104

GND

C22 104/275VAC

CNC D1-D4
AC .ZER O

IC 4 7805

Vin

OUT

+5

E3 4.7UF /25V

: JS2-B46aC-M01A/0

C2 104

IN 4001

2200UF /35V R28 51

F 3A 250V Z R COM 471 10A

U1

CNM
5

C13 104 E4 4.7UF /50F 9 GND P04 7 R47 510


6

+5 47uF /16V
E8 C18 104
CN E

+5 GND
R2 10K
4
CLOCK

M37540
IC 7 AT24C02

CO M
CM

1 2 6
SCL

3 5
SDA

7 4

R3 10K

CN

52C-1A

10

+5
27 28 29
19 P3 2 18 P3 1 20 P3 3

R30 4.7K R29 4.7K

GND
5 DATA

11

P05
R46 510

H EAT

X2A
3 JZ C-7F *3 12

R27 51 R26 51 C15 102 C16 102

CL OCK DA TA

1 2

C2 10 2

C1 10 2

E2 22UF/16V

P06
R45 510

GND
IC 1 74ALS164

20S

X3A

U1 B

30

R44
16

/
HS TP.0

MR

13

P07
510

CLK

9
14

Q0

Q1

Q2

Q3

Q4

Q5

Q6

52CB
15

P02 25
R43 510
2 1 P1

10

11

12

C
FMC

13

R50 220

D11 4148

D9 4148

R8 4.7K

+5 C

F M O

X1A

X2B
14

P03 26
R42 510

/
HS TP.1 P1 3

dh on/o ff

X3B
8

P10 31
2

D8 4148 R51 220

D12 4148

D10 4148

R9 4.7K
6 CO M1

R41
MC2003

510

+5
9 P1 1 32 CO M4 6 P2 5

GND
X1B D6 IN 4148 Q3 9013 R13 4.7K Q2 9013 R54 4.7K

Q9 9012
7 CO M2

BUZ R37 2K
CN U 5 N

GND

R7 4.7K

C21 104/275V

L1

B U1 GND +5
IC 6 R14 330
1

C3 102

BU ZZ P0 1 Xo ut

+5
24 15 8 P2 4

R11 4.7K

GND

GND

XL 8.00

C30 102 Q5 9012

R55 4.7K

R15 300K
Xi n 14

GND
CO M3 5

8 CO M3

CF I 1.2uF
1

R36 220 C20

IC 5

+5 C28
7 P2 3

3 2 BT131

R6 4.7K

P0 0

23

4 6

R10 4.7K

102 Q4 9012

R40 4.7K

9 CO M4

Q7

GND

he at/c ool D7 4148

+5

B
CO M2

3 CN G TE MP 2

473/275V

R35 390 M C3021 R19 510


2

Vs s

GND
16

+5

Q7 1815

+5 GND
K EY R16 10K R52 510

GND
P3 4 21 6 P2 2

+5
C8 104

+5
R12 4.7K Q6 9012

C29 102

R38 4.7K 2 S

Tr

C9 104
1

R20 4.3K

+5

R4

Q8 9012

GND
1G ND
CO M1 3

S 3

RM T H S0038

GND
R31

C4 102

2 1

-+

GND

GND R17 510


R18 4.3k

GND

R49 510
C23

/R ESET

GND
11

Tp

C7 104
3

C6 104

GND10K GND

R23

C17 E5

104

+5
Vc c 13 10

C27 102

R39 4.7K

3 +5V

R1 51 E1 22UF /16V

+5 GND
+5 V S 17 P3 0

CND

GND

GND

GND

GND

3 2 1

10uf/16F 4.7K

R24 C12 102

4.7K

R25 10K

46
EM C
8 A

12 GN D 5 4 3 C NTR0 P1 4

A
R3 AC ..ZE RO R2 10K 4.7K C11 102 Q1 GND C1815

+5
R5 4.7K R48 C24 102 10K C19 102

GND

R53
P2 1/AN 1 P2 0/AN 0 T0 P3 7 IN 2 2

GND
R22 R21 C10 4.7K 101 C25 102 10K

+5

CN W

GND GND
C26 104

GND 1

GND

GND 2

GND 3 4 5

GND

GND 6

9. List of PCB
1PCB material listing(CQS-25H3A-G48AY1/CQS-35H3A-A48AH1)
No. Part code A items A01 0107504000 A02 0107500100 A03 0107200200 A04 0107500202 A05 0107503500 A06 0107700201 A07 0107100201 A08 0107100401 A09 0107100101 A10 A11 A12 A13 A14 0504000100 0113200601 0122100100 0101700801 0101702601 Part name Public materialc IC IC IC IC IC diode audion audion audion Temperature sensor resonator Buzzer R carbon film model M37544G2ASP TD62003AP MC7805CT BT131 MOC3021 IN4007 9013 1815 9012 GT(3274)-001 CST8.00MTW OBO-15240PB17 51 RT-1/4W 4.7K RT-1/4W Qty 1 1 1 1 1 5 1 2 5 1 1 1 2 15 description IC1 IC2 IC4 IC5 IC6 D1-D5 Q3 Q1Q7 Q4-Q6Q8Q9 Installation locationCNG XL BUZ R26R27 R2R5-R12R21 R24 R29-R30 R53R54 3PIN remark

R3R16R17R19 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 0701100302 A35 A36 A37 A38 A39 A40 A41 A42 A43 A44 0701100501 0701100401 0701100601 0701200301 0701200401 1501300600 1501300600 2104000100 0116100100 9803010400 0304200500 Compressor relay safety clip Insurance tube safety Single-Inter calation connector 0101702601 10K 330 510 4.3K R carbon film R carbon film R carbon film R oxidation film R carbon film 2 K 390 300 K 220 220 450VAC 473/275V 104/275V capacitance 102 104 1000F/35V 220F/16V 10uF/25V XH-2A XH-3A XH-3A yellow XH-5A XH-4A XH-6A VH-3A VH-5A XH-2A white white white white white white 1 1 1 1 1 1 1 1 2 1 1 1 CND CNM CNG CNE CNB CNU CNC 52C FUSE FUSE ZR N2 white white RT-1/4W RT-1/4W RT-1/4W RJ-1/4W RT-1/4W RT-1/4W RT-1/4W RY-1W RT-1/4W 9 1 2 2 2 1 1 1 2 1 1 2 8 10 1 1 1 1 1 R22R23R25R31 R48 0101701201 0101701401 0101102201 0101701901 0101701301 0101703401 0101200503 0101701001 0104200202 0104300201 0104300301 0104600811 0104601311 0104101102 0104101001 0104100401 0701100201 0701100301 R14 R49R52 R18R20 R4R37 R35 R15 R36 R50R51 CFI C20 C21C22 C3C4C11C12 C15C16C19C25 C1C2C5-C9C13 C17C26 E7 E2 E5 CNC CNW

1.2F5%CBB61

HF2160-1A-12DE 520mm 3.15A/250AC ZGAY/621-10-126 6.3 KET

A45 A46 A47 A48 A49

2903300103 0125300100 0119200601 1303000211 1102101680

jumper inductance button transformer jumper

0.510mm 0.043mH A06-(c)9.5mm B03-01A JF1DJ46/48DCP21

9 1 1

J1-J6J8-J10 L1 SW1

B items B01 B02 B03 B04 B05 0107701301 1501200400 2903300103 0304200500 0107100201

2-Q cooling and hot plate materials diode relay jumper Single-Inter calation audion resistance IN4148 JZC-32F 12V

156 113.5 D6D9 X3X1 J7 20SFMO Q2 R13

2 2 1 2 1 1 D6D9D10 X1X3 X2 J7 20SFMO HEAT Q2 R13

0.510mm 6.3 9013 KET

B06 0101702201 C items C01 C02 C03 C04 C05 C06 C07 diode relay relay jumper Single-In tercalati on Single-In tercalati on audion

4 7K RT-1/4W Electric heating materials IN4148 JZC-8F 12V 3 2 1 1 2 1 1

SJ-S-112DM 0.510mm 6.3 4.8 9013 KET

10A/250VAC

10A/250VAC

C08 resistance D items D01 D02 0107501000 0104601311

4.7K RT-1/4W 1 Blackout memory materials Manifold capacitance Anion materials Singerzntercalation 6.3 KET AT24C02 104

1 1

IC7 C18

E items E01 0304200500

N1

10

PCB function:

NOTE: Ts is the set temperature, Tr is indoor room temperature, TP1 is indoor coil pipe temperature, TP2 is outdoor coil pipe temperature.

Display panel LED


according to display mode: dehumidification, cooling, ventilation, heating, auto, sleep, fan speed, swing, timer, indoor

fan running.

wind speed indication correspond fan speed of indoor blower fan. Cooling Start up the compressor: when the room temperature is more than Ts+1, compressor start-up Shut down the compressor: when the room temperature is less than or equal to the set temperature Ts-1, compressor shutdown When the temperature of coil pipe of the indoor units is less than or equal to 1 for one minute and the compressor has continuous run for more than ten minutes, the compressor and outdoor blower fan shut down through the electric control board and the indoor blower fan is running at low speed. When the temperature of coil pipe of the indoor units is more than or equal to 7 and the compressor has shutdown for more than three minutes, the compressor and outdoor blower fan start to run and the indoor blower fan is running at set speed. When the temperature of coil pipe of the indoor units is equal to or less than 10 for three minutes in the compressor has continuous run for three minutes, the compressor, indoor and outdoor blower fans and swinging wind shut down. Restart up six minutes later; if the above situations appear again within six minutes, all the outputs are shut down through the electric control board and display failure. After the compressor runs five minutes, the lamp flashes 4 times per six seconds or display E4 if the temperature of indoor coil pips is more than 25 in the continuous 20 minutes. The controller will automatically shut down if the temperature of indoor coil pips is more than 25 in another continuous 20 minutes, that is the abnormality protection of outdoor units and the indicator lamp keeps its former state of flashing. If the temperature of indoor coil pips is less than 25 in the second 20 minutes or the compressor shuts down, the electric control board will store to the normal display and the time is restarted when starting up the compressor next time.

Heating (only applicable to heat pump units) Start up the compressor: when the room temperature is less than Ts-1, compressor start-up Shut down the compressor: when the room temperature is more than or equal to the set temperature Ts+3, compressor shutdown The electric heating start-up in the heating mode shall meet the following conditions: start up the compressor and indoor blower fan none defrost TP1< 49 Tr 20. The electric heating shutdown in the heating mode shall meet one of the following conditions: shutdown indoor blower fan Tr 23 TP150.

In the heating mode, the indoor flower fan can be set as high/ medium/ low /automatic running mode by remote control. however the anti cool air function is prior. In the heating mode, the anti cool air control function is to control shutdown of the indoor blower fan by detecting the temperature of coil pipe of evaporator so as to attain the purpose of preventing cold air from blowing. For the waste heat emission function in the heating mode, in principle, the indoor blower fan shall be on for fifteen seconds after the electric heating is closed. When the temperature of coil pipe of indoor units is more than or equal to 56, the outdoor blower fan shuts down and it enters the overload protection; when the temperature of coil pipe of indoor units is less than or equal to 52, the outdoor blower fan starts up and it exit the overload protection. When the temperature of coil pipe of indoor units rises to 63, the compressor and outdoor blower fan are closed and two minutes later, the change valve is closed. The indoor blower fan is running at the set speed. Restart up six minutes later; if the above situations appear again within ten minutes, all the outputs are shut down through the electric control board and display failure. When you press turbo button of remote, the air conditioner enter turbo running, compressor ,outdoor blower fan and four-way valve turn on all along, indoor blower fan run at high speed and it must meet start condition, turbo indication is light. After the compressor runs five minutes, the lamp flashes 4 times per six seconds or display E4 if the temperature of indoor coil pips is less than 30 (heating) in the continuous 20 minutes. The controller will automatically shut down if the temperature of indoor coil pips is less than 30 in another continuous 20 minutes, that is the abnormality protection of outdoor units and the indicator lamp keeps its former state of flashing.

Defrost (only applicable to the heating mode) 1. the intelligent defrost In the heating mode, the electric control board checks and compares the temperature of indoor room and indoor coil pipe after the compressor works for a while; judge whether the outdoor heat exchanger part is frosted or not according to conditions such as the change of indoor coil pipe temperature; if it is judged as frosted, it automatically enters defrosting process. When defrosting, close the indoor and outdoor blower fan and four-way valve. 2. Outdoor PCB for defrost. In the heating mode, the unit defrost by outdoor control board unit start defrost shall all meet the following conditions acompressor continuous running over 7 minutes bdefrost relay shut off -5 ccompressor cumulate running time over 50 minutes. first defrost interval time is 50 minutes, later defrost interval time decided by last defrost time. Defrost time(minute) 15 10--15 7--10 3--7 3 Next defrost interval time(minute) 30 40 60 70 80

2end defrost condition(meet one of follows) adefrost time have fifteen minutes. bdefrost relay turn on 8

cpress ON/OFF key in defrost process. 3. Outdoor sensor for defrost unit start defrost shall meet one of the following conditions a. compressor cumulate running time over 30 minutes and it continuous running over 3 minutes, the temperature of coil pipe of the outdoor units is equal to or less than 15 for one minutes (Tp2-15). b. compressor cumulate running time over 40 minutes and it continuous running over 3 minutes, the temperature of coil pipe of the outdoor units is equal to or less than 5 for one minutes (Tp2-15). c. Air conditioner first power on or it wait over 30 minutes ,the temperature of coil pipe of the outdoor units is equal to or less than 2 (Tp2-15) end defrost condition(meet one of follows) a. the temperature of coil pipe of the outdoor units is more than 15 (Tp2-15). b. defrost time have fifteen minutes. Sequence chart in defrosting mode Dehumidification Dehumidification running is to eliminate the water vapor in the air by using the cool circulating capacity, but the dehumidification will not decrease the indoor temperature in great deal. The air conditioner automatically repeats on and off circulation according the room temperature, which is shown in the following figure.

Tr

C C
Tr10

indoor blower fan

low speed forbid dehumidify start-upshutdown start-up shutdown shutdown start-up shutdown start-up shutdown

n a rf or oe dw o l b

shutdown start-up shutdown shutdown start-up shutdown start-up shutdown start-up

shutdown

In the dehumidification mode, the indoor fan is running at the low speed for twenty seconds at first, then it select working mode.

Automatic mode Conditions for entering the automatic running mode are: After power-up for the first time, start up and select the automatic operating mode of remote or press emergency key, the working mode depends on Tr and if the working mode had set , it doesnt change by Tr and the default set temperature is 25 .

r T

26 C

1 2 5 2 e d o m
Time on and time off When the time on or time off is used, the clock of remote controller shall be corresponding to the current clock and the timing times is less than or equal to 24 hours, when the timing time is reached, unit will start-up or shutdown. Sleep function When the sleep key is press, air conditioner enter sleep state, indoor blower fan running at low speed, only sleep indication display. Emergency key function There is a forcible execution key on the panel of indoor units and the air conditioner can run by pressing the key when the remote control is out of work or missing. When pressing down the forcible execution key, then power up and enter the self-check program.

Failure display Display state serial failure Running lamp Indoor unit 1 2 3 4 5 6 7 8 9 Indoor TEMP. sensor failure Indoor coil pipe TEMP. sensor failure Overheat (frost) protection Pump failure Indoor blower fan failure Outdoor feedback failure Open door failure Outdoor coil pipe TEMP. sensor failure (EEPROM) communicate failure Outdoor unit 1 2 3 4 5 6 Outdoor TEMP. sensor failure Outdoor coil pipe TEMP. sensor failure Over current protect of compressor TEMP. sensor of exhaust failure Communicate failure Module protection light light light light light light Flash 1 time/8 SEC Flash 2 time/8 SEC Flash 3 time/8 SEC Flash 4 time/8 SEC Flash 6 time/8 SEC Flash 7 time/8 SEC E2 E3 E7 E1 E6 E5 Flash 1 time/8 SEC Flash 2 time/8 SEC Flash 3 time/8 SEC Flash 4 time/8 SEC Flash 6 time/8 SEC Flash 7 time/8 SEC light light light light light light light light light Flash 3 time/8 SEC Flash 4 time/8 SEC Flash 6 time/8 SEC E2 E3 E8 E9 E5 E7 E0 E1 E6 LED Timer lamp LCD

11 . TROUBLE SHOOTING
Indoor Tr sensor error

Is CN (Tr sensor connector) connected properly? YES

NO Connect CN properly.

Is Tr sensor resistance value (5KO at 25? ) normal? YES

NO Replace TA sensor.

Indoor P. C. board is defective.

Replace P. C. board.

Indoor TP1 sensor error

Is CN (TP1 sensor connector) connected properly? YES

NO Connect CN properly.

Is TP1 sensor resistance value (5KO at 25? ) normal? YES

NO Replace TC sensor.

Indoor P. C. board is defective.

Replace P. C. board.

Only indoor fan motor does not operate.


<Primary check> (1) Is it possible to detect the power supply voltage (200-240V) between L and N on the terminal block? (2) Does the indoor fan motor operate in cooling operation? Turn off power supply once, and turn it on again.

Does compressor continue to operate? NO Start to operate indoor unit in cooling operation at airflow level LOW,wait three minutes..

YES

Is it possible to detect AC 220V between pin(high/middle/low) and pin(common) of motor connector .

NO

Replace main P.C. board.

YES Turn off indoor unit and rotate cross-flow fan by hand when the unit is on standby.Is it possible to rotate cross-flow fan by hand properly? YES Is capacitor of indoor fan ok? NO Replace capacitor

Does indoor fan operate? YES

NO

NO

Replace bearing.

YES Fan motor operates normally.

Replace indoor fan motor.

Compressor does not operate.


Turn on power supply. <Primary check> (1) Is the room temperature higher than the preset temperature in cooling operation? (2) Is the crossover cable connected properly? NO Check power supply.

Does OPERATION indication indicate? YES Does compressor delay three minutes by temperature changes or others? YES Wait three minutes

NO

Is resistance value of room sensor (Tr) and heat exchanger sensor (TP1) normal? YES

NO

Room sensor or heat exchanger sensor is defective. Replace room sensor or heat exchanger sensor.

Is it possible to detect AC 220-240V on terminal block or contactor of compressor? YES Are all of compressor cords normal? YES Is compressor motor winding normal?(Check winding resistor.) YES Is capacitor for compressor normal? YES Is overload relay normal? YES Does compressor start? YES Does compressor stop after a while? YES Is gas quantity normal? (Check gas pressure.) YES Compressor is defective.

NO

Microcontroller is defective or miniature relay is defective..

Replace P.C. board.

NO

Rewire or replace defective cords.

NO

Compressor is defective.

Replace compressor.

NO

Capacitor is defective.

Replace capacitor.

NO

Overload relay is defective.

Replace overload relay.

NO

Compressor is defective.

Replace compressor.

NO

Gas shortage (Gas leak)

Supply gas.

YES

Replace compressor.

Press START/STOP button.

The unit does not beep at all. OPERATION indication on indoor unit is not indicated.

Is transmission mark indicated? YES

NO

Is receiver on indoor unit exposed to direct sunlight? YES

NO YES

Press RST button on remote control with tip of pencil.

Is there any thyristor fluorescent light nearby? YES

NO

NO YES

Does indoor unit operate when moving remote control near receiver or indoor unit? YES Batteries are exhausted. Press START/STOP button.

NO

Does indoor unit start to operate by automatic restart function? YES NO

Is transmission mark indicated? YES

NO

Does indoor unit beep and operate? YES

Does radio sound is affected by remote control when a signal is transmitted at distance of 5 cm from radio? YES

NO

Remote control is defective. P.C. board is defective.

Avoid direct sunlight.

Keep indoor unit away from thyristor fluorescent light.

Replace P.C. board.

Replace batteries.

Normal operation

Replace remote control.

Trouble shooting

Trouble

NO

Is the unit display normal? YES Does outdoor unit run?

Is the power applied to the unit? YES Is the power normal? check the voltage between L&N of terminal block Check the compressor ,wires and its capacitor. YES Press the power ON/OFF button of wire control or remote control

NO

Check power supply mains or interconnection wires

NO

Check the wiring of indoor and outdoor

YES Does the compressor run normally? YES Does the indoor unit run? NO

NO

Does the control ok?

NO

YES

Normal

Does the beeper beep?

NO

Control failure YES Does the control PCB ok?

YES NO Is the display all off? YES Check the connector on display PCB connected to control PCB Check the display PCB itself

Check the failure code according to the failure table

NO Control PCB failure

Indoor unit and outdoor unit dont operate

Indoor and outdoor unit dont operate

Does the electric switch cut off after a few nimutes?


YES NO

Does the electric switch cut off?


YES

Is the power supply no problem?


YES Change a good remote, does the air conditioner running? NO Press emergency key, does the air conditioner running? NO Does the fuse of indoor PCB burn out?

NO

Make the power supply ok.

Reconnect the wires.

Is the wires of indoor unit and outdoor unit no problem?


YES

YES

Replace remote control.

Find the reason and replace the failure componet.

NO

Is the insulation of indoor unit and outdoor unit no problem?


YES

YES

Replace remote receiver or display panel.

YES

Replace fuse of indoor PCB.

YES Rreplace the failure componet. NO

NO Does the transformer has output? YES Does the 12V and 5V of indoor PCB have? NO Replace PCB. NO Replace transformer.

Is the resistance of each main component no problem?

YES normal

Вам также может понравиться