RE 29 929/12.99
Replaces: 04.97
H/A 5348/96
Table of contents
Contents Features Ordering code Technical data Terminal allocation Unit dimensions Page 1 1 2 2 3
Features
VT-NE30 power supply unit (unipolar output voltage): For the voltage supply to amplifiers for all proportional valves For the voltage supply to proportional valves with integral electronics VT-NE31 power supply unit (bipolar output voltage): For the voltage supply to amplifiers for servo-valves VT-NE32 power supply unit (unipolar output voltage): Same function like VT-NE30 power supply unit In addition, regulated output voltage for the supply to closedloop control or evaluation electronics or accessory components such as pressure transducers, position measuring systems Compact build, connection via terminal strip Unregulated output voltages (filtered); for VT-NE32, additionally regulated output voltage Vibration strength to DIN IEC 68, insulation testing to VDE 0113 Short-circuit protection by means of fine-wire fuses in the output circuits; with VT-NE32, disconnection of the regulated output after approx. 1.5 s in the case of overloading or short-circuit; restart by pressing the reset key Can be screwed on or snapped onto DIN rail LED lamps Conforms with EU directives (CE sign)
Ordering code VT
Compact power supply unit, unipolar Compact power supply unit, bipolar Compact power supply unit, unipolar and regulated = NE30 = NE31 = NE32
1X / *
Further details in clear text 1X = Series 10 to 19 (10 to 19: unchanged technical data and terminal allocation)
VT-NE30 VT-NE32
1/4
RE 29 929/12.99
Technical data (for applications outside these parameters, please consult us!)
VT-NE30
filtered Operating voltage Frequency Ausgangsleistung Output power (at U = 230 VAC): no load full load Load current Residual ripple (with full load) Fuse Connection cross section Permissible ambient temperature range Storage temperature range Weight
1)
filtered
U f PA UA UA Imax U IS A
230 VAC 10 % or 115 VAC 10 % 47 to 63 Hz 70 VA + 31 VDC 1) + 26 VDC 1) 2,5 A < 3 VAC 4AT max. 4 mm2 20 to + 50 C 20 to + 70 C 2,2 kg 1,3 kg 2,4 kg < 3 VAC 0,8 A M 7 VA + 27 VDC 1) + 24 VDC 1) 7 VA 27 VDC 1) 24 VDC 1) 0,25 A < 3 VAC 0,8 A M 60 VA + 30 VDC 1) + 25 VDC 1) 0,25 A < 3 VAC 0,8 A T 25 VA + 24 VDC + 24 VDC 2,5 A 1 A < 50 mVAC see features
In the case of deviation of 10 % from the operating voltage U = 230 VAC, the output voltage UA changes by 10 %.
Note: For details regarding environment simulation tests in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 29 929-U (declaration on environmental compatibility).
Terminal allocation
P
The compact power supply units VT-NE30 to VT-NE32 are delivered ready-to-connect to an operating voltage of 230 VAC. With screw-on type assembly the plate for the clip-connection has to be removed.
0 115 0 115
0 115 0 115
Rexroth Hydraulics
2/4
VT-NE30 VT-NE32
RE 29 929/12.99
Unit dimensions
4. connection secondary side only with VT-NE30 and VT-NE 31 5. and 6. connection secondary side only with VT-NE32
(dimensions in mm)
0 115 0 115
0 115 0 115
74
60
80
VT-NE30
+ VT-NE32
64 85 64
85
0 115 0 115
47,5
59,5
+24 0 24 VT-NE31
56 78 81
VT-NE30 VT-NE32
70
3/4
Rexroth Hydraulics
102
82
RE 29 929/12.99
Notes
Mannesmann Rexroth AG Rexroth Hydraulics D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 eMail product.support@rexroth.de Internet www.rexroth.com
Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80 / 22 32 56 Fax: 0 14 80 / 21 90 52 E-mail: info@rexroth.co.uk
The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.
4/4
VT-NE30 VT-NE32