POWER CURRENT / VOLTAGE TRANSFORMER TYPE JUK 123a

2GKK610061-EN

IT

ABB

APPLICATION
Current / voltage instrument transformers type JUK 123a are intended for measurement and circuit protection of high voltage line substations with the highest voltage of 123 kV at 50 Hz frequency, in effectively earthed and compensated systems. The combined Instrument transformers are one-phase devices for outdoor application in temperate climate - temperatures from 233 K (-40 C) up to 314 K (+40 C), humidity up to 100% at 303 K (+30 C), altitudes up to 1000 m above the sea level.

DESIGN
Current / voltage instrument transformer type JUK 123a consists of a current and voltage modules enclosed in a common aluminum, hermetic casing filled with transformer oil. The casing consists of the following parts: bottom tank with voltage transformer porcelain or composite insulator head with current transformer shielded expansion bellows.

The bottom aluminum tank is equipped with current and voltage secondary contacts and terminals of equi-potential 2 screens. Terminal blocks make it possible to connect up to 10mm wires and can be equipped with fuses for voltage or surge arresters for current circuits. The voltage and current circuit contacts which are meant for power accounting can be sealed up. The terminal box is equipped with two cable glands PG 21 (the choke range from dim.13 mm up to dim.18 mm) or two glands PG29 (choke range from dim.18 mm to dim. 25 mm). The hollow insulator is made of brown porcelain and has a creepage distance for III class of pollution. On request a silicone hollow insulator with creepage distance for IV class of pollution can be used. The primary current terminals are located in the aluminum head of the transformer. The P2/A terminal is common for voltage and current transformers. The terminals can be executed as either stud (copper, dim. 30 or 40 mm) or flat clamp (made of aluminum) type. Standard dimensions of a flat terminal are showed on the drawing below. The expansion bellows, located in the upper part of a transformer and made of stainless steel compensate for thermal changes of oil-volume. Main electrical insulation is made of electrical grade cable paper which is impregnated with transformer oil. On request the transformer can be equipped with coordinating spark gap, two secondary terminal boxes, different types of secondary terminals (e.g. screwed type), covers for sealing and other dimensions and number of cable glands. Depending on thermal currents values, reconnection ratio and the number of cores and their parameters the current / voltage instrument transformer may be executed as: I. standard unit II. unit of smaller head and less oil content.

PRIMARY TERMINALS

Execution Total weight (incl. oil): porcelain insulator silicone insulator Insulating oil weight

I Max. 650 kg 580 kg 150 kg

II Max. 500 kg 430 kg 100 kg

STANDARDS IEC 60044-3

Page 2/4

TECHNICAL DATA CURRENT / VOLTAGE INSTRUMENT TRANSFORMER JUK 123a


Sl.No 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Parameter Type Standards Rated primary voltage Highest system voltage Rated power frequency withstand voltage 50 Hz Rated lighting impulse withstand voltage 1,2/50 s Minimum creepage distance Rated frequency Total weight Insulating oil weight Dimensions Value JUK 123a IEC 60044-3; PN-E 06553:2000 110: 3kV 123kV 230kV 550kV 3640 or 3800 mm with silicone insulator 50Hz see table see table see dimension drawing Current transformer Rated primary current Rated 1s thermal current Rated dynamic current A kA kA 20 6 15 25 6 15 40 12 30 50 20 50 100 40 100 150 40 100 200 40 100 300 50 125 400 50 125 500 50 125 600 50 125 800 50 125 1000 50 125 1200 50 125 1600 50 125 2000 50 125 3000 63 157 reconnectable 1:2 or 1:2:4 (thermal currents values are subject to change) Rated secondary current 1 A or 5 A Rated continuous thermal current 120% or 150% or 200% Number of cores: 1-5 measuring 1-3 protection 1-4 Measuring cores parameters: total rated output accuracy class Protection cores parameters: total rated output accuracy class Voltage transformer 18. 19. Voltage factor and time Number of windings: measuring protection Measuring windings parameters: rated secondary voltage total rated output accuracy class Residual windings parameters: rated secondary voltage rated output accuracy class 1,5/30s or 1,9 / 8h 1-5 1-4 1-3 100: 3 V or 110: 3 V 10 - 150 VA 10 - 400 VA 0,2 or 0,2 i 3P 0,5 or 0,5 i 3P 100: 3 V or 110: 3 V 25 VA or 50 VA 3P or 6P 2,5 - 30 VA 0,1 2,5 - 60 VA 0,2 or 0,2 S 2,5 - 120 VA 5P or 10P 2,5 - 120 VA 0,5 or 0,5S

12.

13. 14. 15.

16.

17.

20.

10 - 75 VA 0,1 or 0,1 i 3P

21.

Page3/4

CURRENT / VOLTAGE INSTRUMENT TRANSFORMER JUK 123a DIMENSION DRAWING

I1n <1250 A >1250 A 203000 A

A 758 818 920

B 90 120 120

C 30 40 Flat 20

Execution I standard II with smaller head


A

D 2070 1990

H 2735 2500

200 90

P1

P2 B

C secondary terminal box

4xO30 for lifting

earth clamps 12

450 4xO24 for fixing O652

518 628

The manufacturer reserves the right to introduce changes resulting from technical developments. ABB Sp. z o.o. Branch Office in Przasnysz Leszno 59 Street, 06-300 Przasnysz, POLAND Phone: +48 29 75 33 252 , Fax: +48 29 75 33 329