Вы находитесь на странице: 1из 3

ONLINE GAS ANALYSIS Biogas/ AD CDM Landll Gas

GA3000

GA3000
The GA3000 builds on eld-proven, robust gas analysis technology to offer cost effective online monitoring with local data outputs Benets
No training required Low cost of ownership Calibration accredited to ISO 17025 Quick and easy self-installation Compact, self-contained system Gas conditioning included as standard Zero service downtime - Hot Swap capability Clear servicing schedules Field-proven, industry standard equipment Start-up conguration wizard Simple user calibration

Features
CH4, CO2, O2 measurement H2S measurement 0 - 5000ppm (optional) H2S clean air purge Large, clear, backlit display 4-20mA outputs for each gas Alarm relays (user congurable) Gas return-to-process option User replaceable H2S sensor IP54 rated weather-proof enclosure

2010 Geotechnical Instruments (UK) Ltd, Sovereign House, Queensway, Leamington Spa, Warwickshire, CV31 3JR. Tel: +44 (0)1926 338111 Visit our website at www.geotech.co.uk Page 1 of 3 DS12, Iss.01

Technical Specications
GA3000
GENERAL SPECIFICATION
Number of Sampling Points Gases To Be Monitored Reading Intervals Operating Temperature Range 1 CH4, CO2, O2, H2S (optional) Continuous For CH4, CO2, & O2 Congurable For H2S 0C to +40C 110 - 230 VAC 50/60 Hz 0.1A 5% Lithium Manganese Backup Battery For Memory Retention CH4 & CO2 O2 H 2S CH4 CO2 O2 H 2S Gas CH4 CO2 O2 H 2S Response Time, T90 CH4 CO2 O2 H 2S By dual wavelength infrared cell with reference channel By internal electrochemical cell By external module (electrochemical cell) 0 - 70% to specication, 0 - 100% reading 0 - 60% to specication, 0 - 100% reading 0 - 25% 0 - 5000ppm 0-5% vol 0.5% (vol) 0.5% (vol) 1.0% (vol) 0-5000PPM 20 seconds 20 seconds 20 seconds 60 seconds 5-15% vol 1.0% (vol) 1.0% (vol) 1.0% (vol) 15%-FS 3.0% (vol) 3.0% (vol) 1.0% (vol) FS 70% 60% 25%

POWER
Mains Options Consumption Instrument Backup Memory

GAS RANGES
Gases Measured

Range

Typical Accuracy

100ppm or 5% of reading (if greater)

Oxygen Cell Lifetime H2S Cell Lifetime

Approximately 3 years in air Approximately 2 years in air 550 ml/min typically -200 mbar Vacuum -200 mbar Up to Four 4-20mA Output Channels 2 user denable alarms which can be triggered when above or below a set value. Alarms can be latched to advise user if an alarm has occurred. Recovery values can also be dened. 3 single pole changeover 6A 250V relays volt free. Two relays for alarms and one for fault condition

PUMP
Flow Flow-Fail Point Maximum Vacuum Restart

COMMUNICATIONS
Output Channels Alarm Notications Relay Outputs

Sales Ofce: Tel: +44 (0)1926 338111 Fax: +44 (0)1926 338110 Email: sales@geotech.co.uk
Product designs and specications are subject to change without notice. User is responsible for determining suitability of product. Page 2 of 3 Geotechnical Instruments Ltd DS12, Iss.01

Technical Specications
GA3000 continued
PHYSICAL
Weight Size Enclosure Operation Keys Display Gas Conditioning Filters 29 Kilograms 650 x 600 x 210mm Painted Steel 600 x 600 x 210mm IP54 Membrane Panel Keypad Liquid crystal display, 40 x 16 characters Fibre optic woven red back-light for low light conditions User replaceable microbre lter Calibrated Under UKAS Accreditation (Certicate Number 4533)

CERTIFICATION RATING
ISO17025

Sales Ofce: Tel: +44 (0)1926 338111 Fax: +44 (0)1926 338110 Email: sales@geotech.co.uk
Product designs and specications are subject to change without notice. User is responsible for determining suitability of product. Page 3 of 3 Geotechnical Instruments Ltd DS12, Iss.01