Вы находитесь на странице: 1из 24

COAXIAL AND SPECIAL CABLES MANUFACTURING

INDEX 1 2 3 5 7 9 10 12 15 16 17 18 19 20
The Company Quality Technical Information Trunk Beta Bond Cube Digisat NX Bonded Multicoax Drop Messenger Connector Cross Reference RG Mil Security Cables Intercom Cables and R/B Packaging

LEGEND Cu CuSn FeCu CuPet PEG PEXG PE Al2 Al2/S Al3 AlCo PET LSZH PVC
Electrolytic bare copper Tinned copper Copper-plated steel wire Copper/Polyester foil Polyethylene expanded with gas injection (azote) Skin/Foam/Skin Polyethylene expanded with eXtra gas injection Polyethylene Polyester/Aluminium foil Polyester/Aluminium S-foil Aluminium/Polyester/Aluminium foil Aluminium/Polyester/Copolymer foil No migrating polyester film Low Smoke Zero Halogen Polyvinyl chloride

THE COMPANY
BETACAVI s.r.l. is one of the leading quality companies in its sector with major activities in europe and other international markets. Established more than 30 years ago, it now has advanced production technology and a site area of 24000sq metres. BETACAVI is accredited with iso

9001 and en 50117 certification and focuses on: careful selection of quality suppliers, regular staff training, constant technological innovation of production and quality control systems. Flexibility throughout the organisation ensures customers are guaranteed the best service from receipt of enquiry through to the final despatch of the product.

Presences of BETA CAVI s.r.l. in Europe.

MANUFACTURING Latest technology machinery and boasting more than 30 years of know how in the sector have promoted BETACAVI one of the European most complete and innovative coaxial cable manufacturer for Wireless and Broadband Hybrid Fiber Coaxial (HFC) applications. Starting from the extrusion process where in real time we check the production parameters like : - Diameters and Roundness (laser) - Voltage Test - Lump Detection - Capacitance - Expansion Rate and Impedance.

We also record and get report on the whole production by on line graphics. To the braiders hall where we have a production capacity of more than 700.000 meters per day.

PHYSICAL FOAM Vs. CHEMICAL FOAM


Ph before DH
0.0 -10.0

Ph after DH

Ch before DH

Ch after DH

Attenuation (dB/100m)

-20.0 -30.0 -40.0 -50.0 -60.0 -70.0


100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000

-80.0

Frequency (Mhz)

The IEC standard 68-2 part 3 Basic environmental testing procedure define the damp heat test procedure. During a period of 21 days the cable is subjected to a continuous stress of temperature (40 2C) and humidity (93 2/3 %) to reproduce the influence of moisture. According to the norm , after the damp heat test the attenuation of the cable must not have increased more than 5% respect pre-test value. Physical foam (gas injected) dielectric is a standardized process that BETACAVI has implemented since many years. As result of the measurement we obtained 3,5% worst attenuation values starting from 1000 MHz compared to the values measured before the DH Test.

PHYSICAL FOAM AND SKIN-FOAM-SKIN EXTRUSION PROCESS

Thinner coaxial cables compared to the existing ones in


the market but with same or better features Really insusceptible to moisture (much closer and regular expansion cells in the dielectric) More robust and flexible cables

Better Structural Return Loss parameters Lower attenuations Impedance more stable Better velocity ratio values

Above mentioned procedures are the basis to build up our entire range of coaxial cables that we have divided in terms of family groups in function of the application.

Further step was to improve the percentage of nitrogen gas up to 72% so to achieve extremely high quality standards that today we can guarantee for 15 years providing enormous advantages for the end user in terms of durability, flexibility and saving costs. To exceed Physical foam performance and to improve electrical and mechanical parameters has been introduced the Skin-Foam-Skin technique that provides two extra layers of PE materials respectively on the inner conductor and on the outer part of the dielectric. The reason is to compensate the irregularity of the material it self during extrusion process improving the adhesion of the material to the inner conductor and impermeability of the dielectric obtaining results that combined to the previous mentioned can highly exceed and satisfy the most severe international standards.

DURAFLAM

TM

Low Smoke Zero Halogen

Electrically

Mechanically

Duraflam compound Fire resistant Fume emission Corrosivity UV resistance CEI 20-36 CEI 20-37/20-38 CEI 20-37/20-38 ISO 4892-2 IEC 60331 IEC 61034 IEC 60754-2

Duraflam is a Low Smoke Zero Halogen material designed for Universal applications (Indoor and Outdoor use) according to the most severe international standards. - Very low emission of carbon monoxide (CO) - Halogen Free - UV resistance - Watertight material. TESTED QUALITY Our quality is constantly tested in our laboratory with following measurements : - Up to 140 dB Screening efficiency (Triaxial test method with BEDEA Tube norm EN50 289-1-6) - Structural Return Loss - Damp heat steady state test norma EN50 290-1-6 - Attenuation - Impedance Today , BETACAVI is able to guarantee its production for a period of 15 years
More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com 3

TRUNK

Broadband Applications
CONSTRUCTION PARAMETERS Inner conductor Dielectric - gas injection
tape coverage mm 2,20

N92Cu

Coax 4

N115Cu

Coax 3

Norm UNI/EN 50117


Cu 2,20 Cu 2,70 Cu 3,45 Cu

mm

9,20

PEG

10,20

PEG

11,50

PEG

14,90

PEG

% mm %

100 9,80 46

CuPet Cu

100 11,00 66

Cu Cu

100 12,25 52

CuPet Cu

100 15,70 65

Cu Cu

Screen

braid coverage

Sheath
minimal bending radius

mm mm kg/km

12,70 130 125,6

PE

13,60 135 166,2

PE

15,00 150 179,9

PE

19,60 195 321,0

PE

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

All the cables are certified CLASS A


752 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

752 542 82 2,0 4,1 6,3 9,1 9,9 11,8 13,8 15,6 16,7 19,1 >26 >24 >22 <5 >100 >90 >80 4,5 4,4

752 522 85 1,6 3,4 5,2 7,5 8,2 9,7 11,3 12,8 13,6 15,6 >30 >28 >26 <5 >95 >90 >85 3,0 6,0

752 522 85 1,3 2,7 4,2 6,1 6,6 7,9 9,3 10,5 11,3 13,0 >26 >24 >22 <5 >100 >90 >80 1,9 2,5 5

522 85 2,0 4,1 6,3 8,9 9,7 11,7 13,3 15,0 16,0 18,2 >30 >28 >26 <5 >85 >85 >80 4,5 10

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

BETABONDCUBE
CONSTRUCTION PARAMETERS Inner conductor Dielectric - gas injection
tape coverage braid coverage tape coverage

Distribution & Drop > 110db


mm

N29BB

N35BB

RG6BB

RG7BB

RG11BB

Norm UNI/EN 50117


0,65 Cu 0,80 Cu 1,00 Cu 1,25 Cu 1,63 Cu

mm % mm % % mm mm kg/km

2,90 100 3,45 45 100 4,80 25/50 24,5

PEG AlCo CuSn

3,50 100 4,05 40

PEG AlCo CuSn

4,60 100 5,20 45

PEG AlCo CuSn

5,30 100 5,90 41

PEG AlCo CuSn

7,10 100 7,70 41

PEG AlCo CuSn

Screen

Al2/S PVC LSZH

100 5,40 30/60 29,2

Al2/S PVC LSZH

100 6,90 35/70 48,2

Al2/S PVC LSZH

100 7,70 40/80 57,0

Al2/S PVC LSZH

100 10,10 50/100 95,5

Al2/S PVC LSZH

Sheath
minimal bending radius

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

All the cables are certified CLASS A++


751 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

751 531 83 5,6 10,9 16,5 23,2 25,0 29,3 33,7 37,6 40,0 45,1 >35 >33 >30 <2 >120 >110 >100 34 17

751 541 82 4,5 8,7 13,3 18,8 20,3 23,9 27,6 30,9 32,8 37,2 >35 >33 >30 <2 >120 >110 >100 22 13

751 521 85 3,7 7,1 10,8 15,2 16,5 19,4 22,3 25,0 26,6 30,1 >35 >33 >30 <2 >120 >110 >100 14 13

751 531 83 2,9 5,5 8,5 12,0 13,1 15,4 17,8 20,1 21,4 24,3 >35 >33 >30 <2 >120 >110 >100 8,5 9,5 7

541 82 6,7 13,3 20,1 28,2 30,5 35,7 40,9 45,7 48,5 54,7 >35 >33 >30 <2 >120 >110 >100 52 21

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

DIGITAL SAT
NX Bonded
CONSTRUCTION PARAMETERS Inner conductor Dielectric - gas injection
tape coverage mm

DIGISAT NX29H

DIGISAT NX35

DIGISAT NX35H
Norm UNI/EN 50117

DIGISAT NX48

DIGISAT NX48H

0,65

Cu

0,80

Cu

0,80

Cu

1,13

Cu

1,13

Cu

mm

2,90

PEXG

3,50

PEXG

3,50

PEXG

4,80

PEXG

4,80

PEXG

% mm %

100 3,45 65

AlCo CuSn

100 4,05 40

AlCo CuSn

100 4,05 70

AlCo CuSn

100 5,40 45

AlCo CuSn

100 5,40 70

AlCo CuSn

Screen

braid coverage

Sheath
minimal bending radius

mm mm kg/km

4,30 23/45 20,7

PVC LSZH

5,00 25/50 23,6

PVC LSZH

5,00 25/50 27,0

PVC LSZH

6,80 35/70 43,8

PVC LSZH

6,80 35/70 48,9

PVC LSZH

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

CLASS A
751 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

CLASS A
751 531 83 5,6 11,0 16,7 23,4 25,3 29,6 34,0 37,9 40,2 45,4 >35 >33 >30 < 15 >80 >75 >70 34 30 751 531 83 5,6 10,9 16,6 23,2 25,1 29,4 33,7 37,6 39,9 45,0 >35 >33 >30 <5 >90 >85 >80 34 18,5 751 521 85 4,1 7,9 12,0 16,9 18,2 21,4 24,6 27,5 29,2 33,0 >35 >33 >30 < 15 >80 >80 >75 17 18,5

CLASS A
751 521 85 4,1 7,8 11,9 16,8 18,1 21,2 24,4 27,3 29,0 32,7 >35 >33 >30 <5 >90 >85 >80 17 12,5 9

541 82 6,8 13,3 20,2 28,3 30,6 35,8 41,1 45,8 48,6 54,8 >35 >33 >30 <5 >90 >85 >80 52 22,5

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

MULTICOAX
NX Bonded
FEATURES Multicoax is a multicore coax range created to make your life easier. Satellite multiswitch IF distribution systems require mini coax cables with superior performance. NX 35 Bond is perfect for this requirement and is marked with different coloured stripes to facilitate the identification of the cable during installation. Colours range is available in the following versions : - 2 core NX 35 (2 IF SAT) - 5 core NX 35 (4 IF SAT + 1 terrestrial) - 9 core NX 35 (8 IF SAT + 1 terrestrial)

DIGISAT 2x NX35

DIGISAT 5x NX35

DIGISAT 9x NX35

CONSTRUCTION PARAMETERS Single Coaxial Cable single cable sheath Central filler
mm 5,00 NX35 PVC 5,00

Norm UNI/EN 50117


NX35 PVC 5,00 NX35 PVC

mm

3,50

PVC

8,00

PVC

Spirally wound tape

PET

PET

Outer Sheath
minimal bending radius

mm mm

5,0-11,0 130

PVC

15,0 75/150

PVC

20,0 100/200

PVC

Weigth

kg/km

48

185

359

Refer to NX Bonded Cables page for construction and electrical parameters of NX35 Bond Cable.

10

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

DROP

SMATV & DTT Applications


CONSTRUCTION PARAMETERS Inner conductor Dielectric - gas injection
tape coverage mm

DIGISAT N19

DIGISAT N29

DIGISAT N35H

DIGISAT N35

Norm UNI/EN 50117


0,40 FeCu 0,65 Cu 0,80 Cu 0,80 Cu

mm

1,90

PEG

2,90

PEG

3,50

PEG

3,50

PEG

% mm %

100 2,40 60

Al3 CuSn

100 3,40 45

Al3 CuSn

100 4,00 70

Al3 CuSn

100 4,00 40

Al3 CuSn

Screen

braid coverage

Sheath
minimal bending radius

mm mm kg/km

3,60 18/35 15,2

PVC LSZH

4,30 23/45 18,7

PVC LSZH

5,00 25/50 27,1

PVC LSZH

5,00 25/50 24,0

PVC LSZH

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

CLASS A
752 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

752 542 82 6,9 13,5 20,4 28,7 31,0 36,3 41,6 46,4 49,2 55,5 >30 >28 >26 < 15 >80 >80 >70 52 33

752 532 83 5,6 10,9 16,6 23,3 25,2 29,6 34,0 38,0 40,3 45,5 >30 >28 >26 <5 >90 >85 >80 34 18,5

752 532 83 5,6 11,0 16,8 23,5 25,5 29,8 34,3 38,3 40,6 45,8 >30 >28 >26 < 15 >80 >75 >70 34 30

572 79 10,8 21,4 32,4 45,3 48,9 57,2 65,5 73,0 77,4 87,2 >30 >28 >26 < 15 >80 >80 >75 320 36

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer 12

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

DIGISAT N44

DIGISAT N46

DIGISAT N46Cu

DIGISAT N48H

DIGISAT N48

DIGISAT N48Cu

Norm UNI/EN 50117


1,00 Cu 1,00 Cu 1,00 Cu 1,13 Cu 1,13 Cu 1,13 Cu

4,40

PEG

4,60

PEG

4,60

PEG

4,80

PEG

4,80

PEG

4,80

PEG

100 4,90 30

Al3 CuSn

100 5,10 30

Al3 CuSn

100 5,10 30

CuPet Cu

100 5,35 70

Al3 CuSn

100 5,35 45

Al3 CuSn

100 5,35 40

CuPet Cu

6,00 30/60 32,0

PVC LSZH

6,70 35/70 41,7

PVC LSZH

6,70 35/70 43,8

PVC LSZH

6,80 35/70 49,5

PVC LSZH

6,80 35/70 44,3

PVC LSZH

6,80 35/70 45,0

PVC LSZH

CLASS A
752 532 83 4,5 8,8 13,3 18,8 20,4 24,0 27,6 30,9 32,9 37,3 >30 >28 >26 < 15 >75 >75 >70 22 28 752 542 82 4,5 8,8 13,3 18,8 20,4 24,0 27,6 30,9 32,9 37,3 >30 >28 >26 < 15 >75 >75 >70 22 29 752 542 82 4,2 8,6 13,1 18,5 20,1 23,6 27,2 30,5 32,4 36,7 >30 >28 >26 < 15 >80 >80 >75 22 24 752 522 85 4,1 7,8 12,0 16,9 18,3 21,4 24,7 276 29,3 33,2 >30 >28 >26 <5 >90 >85 >80 17 13 752 522 85 4,1 7,9 12,0 17,0 18,3 21,5 24,8 27,7 29,5 33,3 >30 >28 >26 < 15 >80 >80 >70 17 19 752 522 85 3,8 7,7 11,7 16,5 17,9 21,0 24,2 26,9 28,7 32,5 >30 >28 >26 < 15 >80 >80 >70 17 21 13

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

DROP

SMATV & DTT Applications


CONSTRUCTION PARAMETERS Inner conductor Dielectric - gas injection
tape coverage mm

DIGISAT N53

DIGISAT N53Cu

DIGISAT N71

DIGISAT N71Cu

Norm UNI/EN 50117


1,25 Cu 1,25 Cu 1,62 Cu 1,62 Cu

mm

5,30

PEG

5,30

PEG

7,20

PEG

7,20

PEG

% mm %

100 5,90 40

Al3 CuSn

100 5,90 41

CuPet Cu

100 7,80 41

Al3 CuSn

100 7,80 40

CuPet Cu

Screen

braid coverage

Sheath
minimal bending radius

mm mm kg/km

7,30 38/75 48,8

PVC

7,30 38/75 51,3

PVC

10,00 50/100 87,8

PE

10,00 100 81,1

PE

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

752 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

752 522 85 3,4 7,0 10,7 15,0 16,3 19,1 22,1 24,7 26,3 29,7 >30 >28 >26 < 15 >80 >80 >75 14 16

752 532 83 2,9 5,6 8,6 12,2 13,3 15,7 18,1 20,4 21,7 24,7 >30 >28 >26 < 15 >80 >75 >70 8,5 15

752 532 83 2,7 5,4 8,4 11,9 12,9 15,3 17,7 19,9 21,2 24,1 >30 >28 >26 < 15 >80 >80 >75 8,5 13

522 85 3,7 7,2 11,0 15,5 16,8 19,7 22,7 25,4 27,0 30,6 >30 >28 >26 < 15 >80 >75 >70 14 18,5

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer 14

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

MESSENGER
Aerial Installation
Inner conductor Dielectric - gas injection
tape coverage

DIGISAT N46MSN

DIGISAT N53MSN

DIGISAT N71MSN

DIGISAT N92MSN

CONSTRUCTION PARAMETERS
mm 1,00 Cu 1,25

Norm UNI/EN 50117


Cu 1,62 Cu 2,20 Cu

mm

4,60

PEG

5,30

PEG

7,20

PEG

9,20

PEG

% mm % mm N mm mm mm

100 5,10 30 1,30 1176 6,7+2,9 70 52,0

Al3 CuSn

100 5,85 40

Al3 CuSn

100 7,80 41 FeZn 7x0,80 4900 PE 10+4,7 100 118,9

Al3 CuSn

100 9,80 46 FeZn 7x0,80 4900 PE 12,7+5,3 130 167,8

Al3 CuSn

Screen

braid coverage

Messenger
breaking strength

FeZn

1,30 1176

FeZn

Sheath
minimal bending radius

PE

7,3+2,9 75 58,9

PE

Weight ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 50 MHz 200 MHz 450 MHz 862 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz 2400 MHz 3000
(20 C)

752 pF/m % dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB dB dB mOhm/m dB dB dB
(20 C)

752 522 85 3,7 7,2 11,0 15,5 16,8 19,7 22,7 25,4 27,0 30,6 >30 >28 >26 < 15 >80 >75 >70 14 18,5

752 532 83 2,9 5,6 8,6 12,2 13,3 15,7 18,1 20,4 21,7 24,7 >30 >28 >26 < 15 >80 >75 >70 8,5 15

752 522 85 2,2 4,2 6,5 9,2 10,0 11,8 13,7 15,4 16,4 18,7 >30 >28 >26 < 15 >80 >80 >75 4,5 11,5 15

542 82 4,5 8,8 13,3 18,8 20,4 24,0 27,6 30,9 32,9 37,3 >30 >28 >26 < 15 >75 >75 >70 22 29

Structural return loss


MHz 5 - 470 MHz 470 - 1000 MHz 1000 - 3000

Transfer impedance
MHz 5 - 30

Screening efficiency
MHz 30 - 1000 MHz 1000 - 2000 MHz 2000 - 3000

Conductor resistance
inner outer

/Km /Km

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

CONNECTOR CROSS REFERENCE


Cable Type Coax 3 N115 Coax 4 N92 RG11 BBCube Crimp Compression Hardline RG7 BBCube Crimp Compression Hardline RG6 BBCube Crimp Compression Hardline Screw on N35 BBCube Crimp Compression Hardline Screw on N29 BBCube Crimp Compression Hardline Screw on N19 Crimp Compression Hardline N29 Crimp Compression Hardline Screw on NX29H Crimp Compression Hardline Screw on N35 - N35H Crimp Compression Hardline Screw on F 59 ALM 3,7/6,4 F 59 CX3 3,7 Hardline 11 CRFS 37 CMP MC 37 A 043 FTO-3846 FRF-65385/S FTO-37 F 60 MINI 3,2/5,6 CRFS 30 CMPMC 30 FTO-37 FRF-51315 F 60 MINI 3,2/5,6 CRFS 30 CMPMC 30 FRF-51315 Upon request CRFS 22 RF-59/2,4 FTO-37 F 60 MINI 3,2/5,6 CRFS 30 CMP MC 30 FRF-51315 F 59 ALM 3,7/6,4 F 59 CX3 3,7 Hardline 11 CRFS 37 CMP MC 37 A 043 FTO-3846 FRF-65385/S F 56 UNIV 4,9/8,8 F 56 CX3 4,9 Hardline 1 CFS6 CMP6-49 A 025 FTO-66 FRF-59/4,9 SLC-6 F 56 UNIV 5,5/8,8 F 56 CX3 7,5 Hardline 21 CMPPRG 7 A 031 FCC-538 FM RG11 EPA 7,4/11,5 FM RG11 CX3 7,5 Hardline 32 CFS 11 EX 11 Hardline B004 FRF-11475 SLC-11 Cabel Con Hardline 46 Hardline 44 Hardline 413 Hardline 309 PPC Hardline H011 Hardline E063 Hardline E019 Hardline D056 FTO-14 TRATEC Cable Type NX35 - NX35H Crimp Compression Hardline Screw on N44 Crimp Compression Hardline Screw on N46 Crimp Compression Hardline Screw on N46Cu Crimp Compression Hardline Screw on N48 - N48H Crimp Compression Hardline N48Cu Crimp Compression Hardline Screw on NX48 - NX48H Crimp Compression Hardline Screw on N53 Crimp Compression Hardline N53Cu Crimp Compression Hardline N71 Crimp Compression Hardline N71Cu The afore-mentioned technical data are purely indicative and therefore uncomplete. For major informations , please visit the websites of the respective manufacturing companies: Crimp Compression Hardline FM RG11 EPA 7,4/11,5 FM RG11 CX3 7,5 Hardline 32 CFS 11 EX 11 Hardline B004 FRF-11475 SLC-11 FM RG11 EPA 7,4/11,5 FM RG11 CX3 7,5 Hardline 32 CFS 11 EX 11 Hardline B004 FRF-11475 SLC-11 Hardline 01 F 56 UNIV 5,5/8,8 CMPPR 47 A 025 FCC-538 Hardline 01 F 56 UNIV 5,5/8,8 CMPPR 47 A 025 F 56 UNIV 5,1/8,8 F 56 CX3 5,1 Hardline 01 CFS6-J CMP6-51 Hardline A025 FTO-66 FCC-538 F 56 UNIV 5,1/8,8 F 56 CX3 5,1 Hardline 01 F 56 UNIV 5,1/8,8 F 56 CX3 5,1 Hardline 01 CFS6-J CMP6-51 Hardline A025 CFS6-J CMP6-51 Hardline A025 FTO-66 1205-S/F 1205-S/F SLC-6 F 56 UNIV 4,9/8,8 F 56 CX3 4,9 Hardline 01 CFS6 CMP6-49 A 025 FTO-66 1205-S/F SLC-6 FRF-59/4,9 SLC-6 F 56 UNIV 4,9/8,8 F 56 CX3 4,9 Hardline 01 CFS6 CMP6-49 A 025 FTO-66 FRF-59/4,9 SLC-6 Hardline 01 A 025 FTO-45530 CRFS 46 FRF-68460/S F 59 ALM 3,7/6,4 F 59 CX3 3,7 Hardline 11 CRFS 37 CMP MC 37 A 043 FTO-3846 FRF-65385/S Cabel Con PPC TRATEC

www.cabecon.dk - www.ppc.dk - www.tratec.nl

16

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

RG MIL
C-17
CONSTRUCTION PARAMETERS Inner conductor Dielectric
mm

RG 58C/U

RG 213/U

RG 59B/U

RG 11A/U

Norm UNI/EN 50117


19x0,18 CuSn 7x0,75 Cu 0,58 FeCu 7x0,40 CuSn

mm

2,95

PE

7,25

PE

3,70

PE

7,25

PE

Screen

braid coverage

mm %

3,45 94

CuSn

7,95 97

Cu

4,30 97

Cu

7,95 97

Cu

Sheath
minimal bending radius

mm mm kg/km

4,95 25/50 38

PVC

10,3 50/100 163,2

PVC

6,15 30/60 54,2

PVC

10,3 50/100 145,6

PVC

Weigth ELECTRICAL PARAMETERS Impedance Capacity Velocity ratio Attenuation


MHz 100 MHz 200 MHz 400 MHz 600 MHz 800 MHz 1000
(20 C)

502 pF/m % 1002 66

502 1002 66

752 672 66

752 672 66

dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m

15,2 22,2 33,1 42,1 50,6 58,8

5,8 8,7 12,8 16,4 19,8 23,3

10,9 15,8 22,9 28,7 33,7 38,3

6,5 10,0 14,2 18,7 23,0 26,6

Structural return loss


MHz 5 - 300 MHz 300 - 600 MHz 600 - 1000 dB dB dB >30 >25 >23 >30 >25 >23 >30 >25 >23 >30 >25 >23

Transfer impedance
MHz 5 - 30 mOhm/m < 15 < 15 < 15 < 15

Screening efficiency
MHz 30 - 1000 dB
(20 C)

>55

>55

>55

>55

Conductor resistance
inner outer

/Km /Km

37,5 14,0

5,5 4,0

157,0 9,0

21,0 4,3

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

17

SECURITY CABLES

Security cables produced in accordance with norm CEI 79-1 / Sheath in PVC anti-flame norm CEI 20-22

Sheath PVC

SIC 2 SIC 4 SIC 6 SIC 8 SIC 10 SIC 12 SIC 14 SIC 22 SIC 24 SIC 26 SIC 32 SIC 34

mm 3,3

Screen
Al2

Tape
PET

Insulation
PVC

Composition conductors Cu
n x mm 2 2 x 0,22

3,6

Al2

PET

PVC

4 x 0,22

4,3

Al2

PET

PVC

6 x 0,22

4,8

Al2

PET

PVC

8 x 0,22

5,2

Al2

PET

PVC

10 x 0,22

5,5

Al2

PET

PVC

12 x 0,22

6,1

Al2

PET

PVC

14 x 0,22

4,3

Al2

PET

PVC

2 x 0,50 + 2 x 0,22

4,8

Al2

PET

PVC

2 x 0,50 + 4 x 0,22

5,2

Al2

PET

PVC

2 x 0,50 + 6 x 0,22

4,8

Al2

PET

PVC

2 x 0,75 + 2 x 0,22

5,3

Al2

PET

PVC

2 x 0,75 + 4 x 0,22

PACKAGING
Security Cables Intercom Cables

Shrink Foil
mt
100

100

R/B

100

18

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

INTERCOM CABLES
Solid intercom cables with external sheath CuSn conductors

CFG2 CFG4 CFG6 CFG8 CFG10 CFG12 CFG16

n x mm 2 x 0,6

4 x 0,6

6 x 0,6

8 x 0,6

10 x 0,6

12 x 0,6

16 x 0,6

R/B

Flat twin-lead

Cu conductors

R/B35 R/B50 R/B75 R/B100 R/B150

nx mm2 2 x 0,35

2 x 0,50

2 x 0,75

2 x 1,00

2 x 1,50

More detailed technical bulletins, graphics and data are available on our web site www.betacavi.com

19

PACKAGING
Cable type
N92Cu Coax 4 N115Cu Coax 3 N29BB N35BB
3

Easy Pack

Wooden Reel 500/1000 500/1000 500/1000 350/700

km x pallet 2/4 2/1 2/1 1,4/0,7 14,4 7,2/6 7,2/6


Pallet with 24 EasyPack boxes

200 100/250 100/250 250/500


3

3 3 3

RG6BB RG7BB

3/6 3/2 14,4 14,4 14,4 7,2/6 7,2/6 7,2


Pallet with 72 EasyPack boxes

RG11BB NX29H NX35 NX35H NX48 NX48H

250/500 200 200 200 100/250 100/250 100 500 500 200 200 100/250 100/250 100/250 100/250 100/250 100/250 100/250 100/250 100/250 100/250 250/500 250/500 500/1000 500/1000 500/1000 500/1000 100 100 500/1000 500/1000 500/1000 500/1000

2 x NX35 5 x NX35 9 x NX35 N19 N29 N35H N35 N44 N46 N46Cu N48H N48 N48Cu N53 N53Cu N71 N71Cu N46 MSN N53 MSN N71 MSN N92 MSN RG 58 C/U RG 213 /U RG 59 B/U RG 11 A/U 20

2 0,5 14,4 14,4 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 7,2/6 3/2 3/2
Wooden Reel EasyPack

7,2/6/12 2/4 7,2/6/9 2/4

COAXIAL AND SPECIAL CABLES MANUFACTURING

BETA CAVI s.r.l. - via delle industrie - 84091 Battipaglia (Sa) Italy tel. +39 0828 308765 - 345912 Pbx - fax ++ 39 0828 342283 www.betacavi.com - e-mail: info@betacavi.com

IFI RT E

LI

TY S YS

UNI - EN - ISO 9001 CERTIFICATO N 9125. BETC

apr '08

EM

QU