Pages 9 10 Detergent/Rinse Aid Dispenser Page 11 Page 12 Heater Access Fuse and Relay access
Pages 13 - 16 Error Codes & Service Test Modes Page 17 Pages 18 Thermistor Temperature / Voltage Chart Cycle Time Chart
Extra Large Capacity Elegant Design with Digital Touch Sensors Increased Convenience Super Quiet Operation No Filter Cleaning Required
End function A. When all of the cycles within the selected cycle is executed, this function is executed. B. During this function, the End sign is displayed with the MELODY generated. C. After the selected cycle is completed, the power automatically turned OFF.
Operating Principles
Operating principle and order of dish washer
cycle
Inner Space Pre wash
Dishes
Front
Main wash
Rinse
Dishes
Dry
Water Heater
Disposer
Grinds the leftover food to make the particles smaller in size High temperature water
Flow Meter
Normal water fill Flow meter must count the water flow for this unit to operate. Water level switch is activated by water from the inlet only. You cant just pour water into the unit to test it. Flow Meter
Selecting this option diverts water, with the distributor motor, to run the upper spray arm only
Distributor motor for Half Load operation. Test Mode P8 Micro Switch for motor. Cam to activate switch Fault code PE
Dishwasher
Dishwasher
Accessing Heater Remove mesh filter assy Remove shield Remove heater
Removing the shield without removing the filter assy could result in broken tabs
Check List If reassemble the terminal of Relay after check or replacement, you must be careful. Dont confuse.
Cause . __________________ When leakage sensor detects 4.5V or below for 1 second. . . . . __________________ When the button is pressed continuously for over 30 seconds
Reason . __________________ Base part hose connection defect Sump and Tub assembly defect Drain Pump assembly defect Main PBA defect __________________ Sub PBA defect Main PBA defect
Tests Without Pulling D/W ___________________ . . . . . . . .__________________ Check for moisture in console
Service Press the ALL is displayed for Inspection Delay Start the first three (3) Mode + Normal + seconds and then t1 Power keys at the same time
You can change the mode by pressing the Normal key. Each time the Normal key is pressed, the mode changes in the order of t1 t2 t3 t4 t5 t6 t7 t8. Live Test Notes Water fill in approximately 70 seconds average water pressure, fills to about 1 inch past heater shield (very little water showing in unit) Water not needed in unit for 45 second drain pump test
Test Related Symptom Activate Mode Mode parts 1. When the pulse of Water supply valve 4E error If you press the Delay t1 Inlet valve, Check valve resistance 100 or less is detected defect 9E error Start key, water is drained Flow and voltage at brown 1 minute after the for 45 seconds and then wire at CN14 to yellow Meter, Low Flow Meter defect water supply starts Level the water Foregin particles within wire at detergent 2. When flow meter Sensor supply starts. dispenser 1.2 K ohms water supply valve pulse is 5 or less, 5 If the pulse count is more @ 120vac Water supply valve seconds after the than 660, change the terminal not connected water supply starts. mode. Main PBA defect 3. When the water is Make sure to change the not detected 5 minutes mode when the pulse after the water supply count is more than 660 in starts t1 mode.
Reason
Tests Without Pulling Test D/W Mode Perform service test t3, run for 3 minutes and compare the display temp with actual water temp Celsius. It should be within about 8 degrees C. Difference due to tank vs. sump temperature. t3
Water 4 E 1 When 80 or above is Thermistor Defect supply detected during water Water supply Error supply temperature of 80 or above Main PBA defect
HE error
1. Press the Delay Start After temp key to start or stop the increases 2 heater and the circulation degrees C, time pump. is about 50 2. If a low water level is seconds for sensed, water is supplied each degree C again and the operation increase continues. 3. The current temperature is shown on the display. 4. It operates up to 70C. t6 to OFF with 1. MICRO SWITCH On no water t6 to The sensing state is ON with water displayed as On on the 88 segment display. 2. MICRO SWITCH Off The sensing state is displayed as OFF on the 88 segment display. 1. Press the Delay Start After temp key to start or stop the increases 2 heater and the circulation degrees C, time pump. is about 50 2. If a low water level is seconds for sensed, water is supplied each degree C again and the operation increase continues. 3. The current temperature is shown on the display. 4. It operates up to 70C.
Drain 5E Error
Heater HE Error
Drain pump defect Low Level Sensor defect Foreign particles clogging mater drain hose Drain valve terminal not connected Main PBA defect When the temperature Heater defect change is 4 or less Heater Relay defect within the Heater terminal not first 10 minutes after connected the heating starts Main Wire-Harness defect Main PBA defect When OFF status of Low Level S/W is not detected within3 minutes during the drain
Perform service test t6 Check motor resistance and voltage at white on CN1 to orange wires at CN14 42.2 ohms @ 120vac
t6
Perform service test t3, will heat water approximately 1 degree C per minute If not working, relay driver voltage is on main pcb red wire CN7 to white wire on door switch on right, looking at back of panel. Will read approximately 50 ohms and 12vdc off and 0.5vdc on.
t3
HE error
Reason
Tests Without Pulling Test D/W Mode Perform service test t3, will heat water approximately 1 degree C per minute If not working, relay driver voltage is on main pcb red wire CN7 to white wire on door switch on right looking at back of panel. Will read approximately 50 ohms and 12vdc off and 0.5vdc on. Perform service test t3, run for 3 minutes and compare the display temp with actual water temp Celsius. It should be within about 8 degrees C. Difference due to tank vs. sump temperature t3
When the temperature Heater Relay defect of the Thermistor is Thermistor defect 80 or above for Main PBA defect more than 3 seconds
HE error
1. Press the Delay Start After temp key to start or stop the increases 2 heater and the circulation degrees C, time pump. is about 50 2. If a low water level is seconds for sensed, water is supplied each degree C again and the operation increase continues. 3. The current temperature is shown on the display. 4. It operates up to 70C.
t3
HE error
1. Press the Delay Start After temp key to start or stop the increases 2 heater and the circulation degrees C, time pump. is about 50 2. If a low water level is seconds for sensed, water is supplied each degree C again and the operation increase continues. 3. The current temperature is shown on the display. 4. It operates up to 70C. 1. Press the Delay Start key to start the 2 parts. 2. t5 starts blinking on the display while water is being drained. 3. When draining is finished, t5 is displayed without blinking. pump out is approximately 30 seconds
Drain 5E Error
When OFF status of Low Level S/W is not detected within3 minutes during the drain
Drain pump defect Low Level Sensor defect Foreign particles clogging mater drain hose Drain valve terminal not connected Main PBA defect
Perform service test t6 Check motor resistance and voltage at white on CN1 to orange wires at CN14 42.2 ohms @ 120vac
t5
5E error
Error Error Cause type Mode Half load error PE When micro s/w is not detected for over 30 seconds after the Distributor motor starts
Reason
Tests Without Pulling Test D/W Mode Perform service test t8 Violet wire CN 14 to Yellow wire at detergent dispenser 2.6 K ohms @ 120vac t8
Distributor motor defect Micro sw terminal not connected Main PBA defect
PE Error
1. If you press the Delay ON 8 seconds, Start key, the parts OFF 4 seconds operate just once. Water not 2. There is no stop needed in unit function. 3. While the synchronous motor is operating, its sensing state is displayed as On/OFF on the 88 segment display. 4. When the synchronous motor stops, the sensing state (On/OFF) of the micro switch is displayed.
t2
Circulation Nozzle does 1. Press the Delay Start Place some Motor not spray key to start or stop the cups on racks and run pump. 2. If a low water level is circulation pump detected, water is to verify water distribution in supplied again and the operation continues. tub. Fan Motor Fan Motor Press the Delay Start key not working to start or stop the fan motor. Listen for fan running Water not needed in unit Actual temp C of water in sump Water not needed in unit
t4
t7
Prewash 1
16:30 17:30 16:30 5:30 5:30 ~17:30
Prewash 2
(16:30) 17:30 (17:30)
Prewash 3
17:30 (17:30)
Main wash
32:30 46:30 37:30 11:30 11:30 ~46:30
Rinse 1
7:30 7:30 7:30 9:30 7:30 7:30
Rinse 2
(7:30) 7:30 (7:30)
Rinse 3
32:30 46:30 32:30 12:30 12:30 ~46:30
Dry
20 20 20 20
Total Time
110~134 181 115 11 38 58~181
Pre-wash 1,2,3
-
Main wash
120F (49C) 149F (65C) 113F (45C) 113 F (45C) 113~149F (45~65C)
Rinse 1,2
-
Rinse 3
No Sanitize 140F (60C) 158F (70C) 140F (60C) 140F (60C) 140~158F (60~70C) Sanitize 162F (72C) 162F (72C) 162F (72C) 162F (72C) 162F (72C)
No Power Troubleshooting
1. When the power does not come on
The power does not come on.
Is the voltage between orange (No. 6) and pink (No. 7) of CN7 connector of main PBA 4.5V or above and the voltage between orange (No. 6) and white (No. 9) 10.5V or above?
N
The main PBA is defective. Please replace it.
N
Is the connector of graphic LED seated properly? Connect the connector firmly.
Y N
Is the condition of graphic LED normal?
Y
Is the voltage on CN7 between orange (No. 6) and pink (No. 7) 4.5~5.25V and the voltage between orange (No. 6) and white (No. 9) pin 10.5-13V?
Y
Graphic LED is defective. Please replace it.
No Buzzer Troubleshooting
Cant hear the buzzer sound and the display part is not turned on.
N
Is the power switch ON? Turn on the power switch. (All selection switches are valid only when the power switch is turned ON.)
Y
Is the SUB PBA connector properly seated?
N
Connect the connector firmly.
Y
Is the voltage on CN7 between orange (No. 6) and pink (No. 7) connector of main PBA 4.5V or above and the voltage between orange (No. 6) and white (No. 9) 10.5V or above?
N
Main PBA is defective. Please replace it.
Y
SUB PBA ASSY is defective. Please replace the Control Pane ASSY.
No Drain Troubleshooting
The drain is not working. (5E)
Y N
Is the drain hose clear? Clean the inside of the drain hose.
Y
Is the Low Level Sensor working normally? (Check service test mode t8 and check the float operation.)
Y
Is the drain pump terminal normal?
Y
Does the drain motor read about 25?
N
Drain pump is defective. Please replace it.
Y N
Is the main relay working normally? Refer to Main relay is not working. Main relay is defective. Please replace it.
Y
Main PBA ASSY is defective. Please replace it.
Does the valve open continuously? Y Does the water valve stay open for 5 minutes straight? Y The water supply pressure is too low. Check household water supply and shutoff valve to D/W.
Y N
Is the wire connection firmly connected?
N
Is the fan connection seated? Firmly connect the connector.
Y
Does the Fan Motor coil read about 150?
Y N
ASSY Fan Vent is defective. Please replace it. Is the Dispenser operating relay operating?
SERVICE BULLETIN
PRODUCT: BULLETIN NUMBER: BULLETIN DATE: MODELS: Chassis
SUBJECT: Customer complains the unit starts operating by itself. SYMPTOM: The front panel buttons activate with very light pressure and are very sensitive. SOLUTION: Order and install new ASSY Panel Control (DD97-00105A). The replacement board has been reprogrammed to reduce the sensitivity of the buttons.
ELECTRONICS
Note: Consult the Samsung Service Website at (http://service.samsungportal.com) for the Service Manual and other information on this product.
This information is published for experienced repair technicians only and is not intended for use by the public. It does not contain warnings to advise non-technical individuals of possible dangers in attempting to service a product. Only experienced professional technicians should repair products powered by electricity. Any attempt to service or repair the product or products dealt with in this information by anyone else could result in serious injury or death. Information provided in this bulletin is subject to change or update without notice.