Multiple choice ouestion 1.

The bench cannot be designed to work at lower frequencies [A ] a) Becomes too lengthy b) becomes too small c) Standing waves do not occur at lower frequencies d) none 2. The purpose of the microwave bench is [C ] a) to test transmission line theory principles b) to observe standing wave pattern c) both d)none 3. The microwave bench in lab designed to work in the band [A ] a) X b) L c) S d) C 4. The minimum frequency that can exist in the Bench (approx.) is [A ] a) 9 GHz b) 12 MHz c) 9 MHz d) None 5. The maximum frequency that can exist in the Bench (approx.) is [B ] a) 9 GHz b) 12 MHz c) 9 MHz d) None 6. The mode used in the laboratory bench is [A ] a) Dominant mode b) degenerate mode c) any one of the above two d) none 7. The cut off wave length of the bench is [A ] a) 2a b) 2b c)c f d) none 8. For radio frequencies above 1000 MHz the method used for Impedance measurement is [A ] a) Slotted line b) Impedance Bridge c) Either of the method d) None 9. The isolator used in between source and slotted section is [B ] a) Avoid harmonics in the source b) to prevent the reflected wave entering back into the source c) A & B d) None 10. In VSWR meter the amplifier is of high gain because [A ] a) Input to meter in low b) To provide multi range facility c) Both d) None 11. In VSWR meter, the amplifiers gain is variable because [B ] a) Input to meter in low b) To provide multi range facility
DOEC/Lecture notes/5EC5 MWI Page 1

c) Both d) None 12. The amplifier in VSWR meter is tuned to a frequency [A ] a) 1 KHz b) 2 KHz c) 10 KHz d) 100 KHz 13. The lower part of the VSWR meter scale represents [A ] a) VSWR b) Power c) Attenuation d) None 14. The PiN diode in the bench is used to modulate the output of [B ] a) Reflex klystron b) Gunn oscillator c) Both c) None 15. In VSWR meter the amplifier used is ac type because [A ] a) to avoid drift problem of dc amplifiers b) Cheap c) Small size d) All 16. The diode detector was input/output relation that is [C ] a) Non linear b) Square c) Both d) None 17. The mode of the wave over the bench is [C ] a) Dominant b) TE10 c) Both d) None 18. In wave meter the pointer is [B ] a) Oscillatory b) Rotary c) Stationary d) None 19. In the bench the source is always followed by [B ] a) Attenuator b) Isolator c) Wave meter d) Detector 20. In the bench the source is modulated by a frequency [A ] a) 1 KHz b) 10 KHz c) 100 KHz d) None 21. Tunable probe exists over / in [B ] a) VSWR meter b) Slotted section c) Attenuator d) None 22. The method used to measure high VSWR is [B ] a) Slotted line method b) Double minimum method c) Both d) None 23. Low VSWR method can be used to measure VSWR up to [A ]
DOEC/Lecture notes/5EC5 MWI Page 2

a) ten b) five c) three d) None 24. In low VSWR method, in VSWR meter the pattern maximum [A ] is set to a) One b) zero db c) Both d) None 25. In high VSWR method, in VSWR meter the pattern minimum [C ] is set to a) One b) zero db c) Three db d) None 26. While measuring guide wave length, the termination of the bench [A ] must be a) Short b) Matched termination c) Open d) None 27. While measuring guide wave length, always minimum points are [C ] considered because a) Minima are sharp b) minima are easily locatable c) Both d) None 28. Guide wave length does not depend upon [A ] a) Termination b) frequency c) Mode of the wave d) none 29. While measuring attenuation, the termination of the bench must be [B ] a) Short b) Matched termination c) Open d) None 30. Gyrator gives a phase shift to a wave travelling from output [B ] to input a) 180o b) 0o c) 90o d) None 73. Calibration standards are [C ] a) Rotary type phase shifter b) Rotary type attenuator c) Both d) None 31. The range of VSWR in db indicated VSWR meter is [B ] a) 0-2db b) 0-10db c) 0-5db d) 0-100db 38. For low power measurement the technique used is [A ] a) Bolometer technique b) Calorimeter technique c) Reflect meter technique d) Calorimetric wave meter technique

DOEC/Lecture notes/5EC5 MWI

Page 3

32. The magic T can be used for the measurement of [B ] a) Frequency b) Impedance c) Q factor d) None 33. Thermo couple is a junction of [B ] a) Two similar metals b) Two dissimilar metals c) Identical but different lengths d) None 34. The Smith chart is [D ] a) A Polar plot b) represents complex reflection coefficient c) Inscribed in a unity circle d) all 35. The complete circles in the smith chart represent [C ] a) Normalized resistance b) Normalized conductance c) Both d) none 36. The arcs in the smith chart represent [C ] a) Normalized reactance b) Normalized susceptance c) Both d) none 36. The circles and arcs over the smith chart are [A ] a) Orthogonal b) opposite to each other c) At 450 d) None 37. The upper half of the smith chart represents [C ] a) Inductive reactance b) inductive susceptance c) Both d) None 38. The lower half of the smith chart represents [C ] a) Capacitive reactance b) capacitive susceptance c) Both d) None 39. The radius of the constant SWR circle is [C ] a) Voltage SWR b) current SWR c) Both d) None 40. The centre of the constant SWR circle is [C ] a) 1of horizontal line b) centre of the chart c) Both d) None 41. Smith chart is always used with [B ] a) Normalized impedances b) Normalized admittances c) Both d) None

DOEC/Lecture notes/5EC5 MWI

Page 4

42. The centre of the arcs of the smith chart is [C ] a) r 1r ,0b) 1,1 x c) r 1r ,1d) 1, r 1r

43. The centre of the circles of the smith chart is [C ] a) r 1r ,0b) 1,1 x c) r 1r ,1d) 1, r 1r

44. In wave meter the pointer is [B ] a) Oscillatory b) Rotary c) Stationary d) None 45. In the bench the source is always followed by [B ] a) Attenuator b) Isolator c) Wave meter d) Detector 46. In the bench the source is modulated by a frequency [A ] a) 1 KHz b) 10 KHz c) 100 KHz d) None 47. Tunable probe exists over / in [B ] a) VSWR meter b) Slotted section c) Attenuator d) None 48. The method used to measure high VSWR is [B ] a) Slotted line method b) Double minimum method c) Both d) None 49. Low VSWR method can be used to measure VSWR up to [A ] a) ten b) five c) three d) None 50. In low VSWR method, in VSWR meter the pattern maximum [A ] is set to a) One b) zero db c) Both d) None 51. In high VSWR method, in VSWR meter the pattern minimum [C ] is set to a) One b) zero db c) Three db d) None 52. While measuring guide wave length, the termination of the bench [A ] must be
DOEC/Lecture notes/5EC5 MWI Page 5

a) Short b) Matched termination c) Open d) None

DOEC/Lecture notes/5EC5 MWI

Page 6