Sales & Products Quality Service Compressed Air Dryers Compressed Air Treatment Accessories Evaporative Cooling Towers Dry Cooling Towers Industrial Chiller Catalogues Compressed Refrigerated Air Dryer Wall Mounted Refrigerated Air Dryer High Pressure Refrigerated Air Dryer Refrigerated Air Dryer Compact Heatless Air Dryer Heatless Air Dryer Heatless Desiccant Air Dryer Moisture Separator Compressed Air Filter Automatic Drain Valve Water Cooled After Cooler Air Cooled After Cooler Compressed Air Receiver Bottle Cooling Tower Square Cooling Tower Cross Flow Cooling Tower Evaporative Coil Cooling Tower Modular Cooling Tower Double Cross Flow Cooling Tower Dry Cooling Tower Aqua Saver Head Office & Customer Care Ahmedabad, Gujarat Aurangabad, Maharastra Bengaluru, Karnataka Bhopal, Madhya Pradesh Chandigarh Chennai, Tamilnadu Coimbatore, Tamilnadu Cuttack, Orissa Delhi Hyderabad, Andhra Pradesh Jamshedpur, Jharkhand Kolkata, West Bengal Lucknow, Uttar Pradesh Madurai, Tamilnadu Mumbai, Maharastra Nagpur, Maharastra Nasik, Maharastra Pune, Maharastra

Contact

Raipur, Madhya Pradesh Rajkot, Gujuarat Sangli, Maharastra Secundrabad, Andhra Pradesh Sivasagar, Assam Surat, Gujuarat Tirupur, Tamilnadu Vadodara, Gujuarat Visakhapatnam, Andhra Pradesh

GEM Equipments Limited Air Treatment Accessories Air Receiver VAR Series

Products

COMPRESSED AIR DRYERS & ACCESSORIES Specifications


Refrigeration Air Dryers
Compressed Refrigerated Air Dryer Wall Mounted Refrigerated Air Dryer High Pressure Refrigerated Air Dryer Refrigerated Air Dryer

Desiccant Air Dryers


Compact Heatless Air Dryer Heatless Air Dryer Heatless Desiccant Air Dryer

Air Treatment Accessories


Moisture Separator Compressed Air Filter Automatic Drain Valve Water Cooled After Cooler Air Cooled After Cooler Compressed Air Receiver

Salient Features Designed as per IS7938 Hand and man holes Working pressure upto 40 bar Shell / Dish as per ASME Sec VIII and IS2825

COOLING TOWERS
FRP / Evaporative Cooling Towers
Bottle Cooling Tower Square Cooling Tower Cross Flow Cooling Tower Evaporative Coil Cooling Tower Modular Cooling Tower Double Cross Flow Cooling Tower

Gem Air Receiver helps to Store compressed air. Condense and trap the moisture in the compressed air and to let the impurities settle down before air passes into the piping. Equalise pressure variations in the pipe. Prevent short cycle loading and unloading of the compressor.

Dry Cooling Towers


Dry Cooling Tower Aqua Saver

INDUSTRIAL COOLERS
Refrigeration Industrial Chiller

Gem air receiver are dimensioned to suit the compressor flow rate, the regulating system, the working pressure and the expected variations in the air consumption. Mountings

a) Safety Valve: Air receiver shall be provided with a safety valve preferably of direct spring loaded type and shall be soon constructed and adjusted as to permit the air to escape from air receiver without increasing the pressure beyond 10% above the working pressure. b) Drain Valve: A drain valve either manually operated or automatic in operation shall be provided to drain the condensate. c) Pressure Guage: A pressure guage of bourdon type conforming to IS 3624 - 1996 shall be fitted in the Air Receiver. The dial shall be graduated in bar and the graduate shall be from zero to not less than 1.5 times and not more than 2 times the design pressure of the receiver. d) Fusible Plugs: Fusible Plugs shall be fitted to safe guard the installation in case of excessive rise in temperature due to fire.

TECHNICAL SPECIFICATIONS Model Overall Capacity Diameter Height m (inner) mm mm Working Pressure bar 7 VAR025 0.25 490 1610 10.5 12.5 7 VAR50 0.5 610 2005 10.5 12.5 7 VAR075 0.75 734 1900 10.5 12.5 7 VAR100 1.0 734 2750 10.5 12.5 7 VAR150 1.5 980 3165 10.5 12.5 7 VAR200 2.0 980 3165 10.5 12.5 VAR250 2.5 980 3820 7 Shell/Dish Thickness mm 5/5 10.5 12.5 5/5 5/6 6/8 5/6 5/6 8/8 5/6 8/8 10/10 5/6 8/8 10/10 5/6 8/8 10/10 5/6 2" NB FLG 2" BSP 2" BSP 1 1/2" BSP 1 1/2" BSP 1" BSP 3/4" BSP In/Out Connection Design Presure bar 8 12 14 8 12 14 8 12 14 8 12 14 8 12 14 8 12 14 8 Hydro Test Pressure bar 12 18 21 12 18 21 12 18 21 12 18 21 12 18 21 12 18 21 12 Man Hole Man Hole 475x425mm Man Hole 475x425mm Hand Hole Hand Hole Hand Hole Hand Hole Hand Hole / Man Hole

10.5 12.5 7 VAR300 3.0 980 4485 10.5 12.5 7 VAR400 4.0 1289 3575 10.5 12.5 7 VAR500 5.0 1289 4340 10.5 12.5 7 VAR600 6.0 1289 5095 10.5 12.5 7 VAR800 8.0 1464 5300 10.5 12.5 7 VAR1000 10.0 1464 6510 10.5 12.5

8/8 10/10 5/6 8/8 10/10 8/8 10/10 12/12 8/8 10/10 12/12 8/8 10/10 12/12 8/10 12/12 12/14 8/10 12/12 12/14 8" NB FLG 8" NB FLG 6" NB FLG 4" NB FLG 4" NB FLG 4" NB FLG

12 14 8 12 14 8 12 14 8 12 14 8 12 14 8 12 14 8 12 14

18 21 12 18 21 12 18 21 12 18 21 12 18 21 12 18 21 12 18 21

475x425mm

Man Hole 475x425mm

Man Hole 475x425mm

Man Hole 475x425mm

Man Hole 475x425mm

Man Hole 475x425mm

Man Hole 475x425mm

* Product Design and specifications are subject to change due to constant upgradation.