Вы находитесь на странице: 1из 18

BSC3119 Nokia BSC/TCSM, Rel. S12, Product Documentation, v.

EG - GSM Timer and BSC Parameter Handling

DN9813203 Issue 9-0 en

# Nokia Corporation

1 (18)

EG - GSM Timer and BSC Parameter Handling

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This document is intended for the use of Nokia's customers only for the purposes of the agreement under which the document is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Nokia. The document has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this document concerning the suitability, capacity, or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Nokia and the customer. However, Nokia has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia will, if necessary, explain issues which may not be covered by the document. Nokia's liability for any errors in the document is limited to the documentary correction of errors. NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY LOSSES), that might arise from the use of this document or the information in it. This document and the product it describes are considered protected by copyright according to the applicable laws. NOKIA logo is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their respective companies, and they are mentioned for identification purposes only. Copyright Nokia Corporation 2007. All rights reserved.

2 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

Contents

Contents
Contents 3 List of tables 4 List of figures 5 Summary of changes 7 EG - GSM TIMER AND BSC PARAMETER HANDLING 9 EGO OUTPUT TIMERS/PARAMETERS 11 EGT MODIFY TIMER 13 EGP MODIFY PARAMETER 17

DN9813203 Issue 9-0 en

# Nokia Corporation

3 (18)

EG - GSM Timer and BSC Parameter Handling

List of tables

4 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

List of figures

List of figures

DN9813203 Issue 9-0 en

# Nokia Corporation

5 (18)

EG - GSM Timer and BSC Parameter Handling

6 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

Summary of changes

Summary of changes

Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Changes made between issues 9 and 8V


EGO OUTPUT TIMERS/PARAMETERS The execution printout was updated.

Editorial changes.

Changes made between issues 8V and 8


EGT MODIFY TIMER Changed the explanation of 'time unit' as timers T3168 and T3192 have different ranges of values.

Changes made between issues 8 and 7 (61)


Changes due to new functionalities

EGO

OUTPUT TIMERS/PARAMETERS Two new timers (T3168, T3192) were added to EXECUTION PRINTOUTS. MODIFY TIMER Two new timers (T3168, T3192) and their rules for timer unit guide were added to PARAMETER EXPLANATIONS. One example about timer value guide for timer T3168 was added to EXAMPLES.

EGT

DN9813203 Issue 9-0 en

# Nokia Corporation

7 (18)

EG - GSM Timer and BSC Parameter Handling

8 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

EG - GSM TIMER AND BSC PARAMETER HANDLING

EG - GSM TIMER AND BSC PARAMETER HANDLING


With the commands of this command group you handle GSM timers and BSC parameters. Menu of the command group:
GSM TIMER AND BSC PARAMETER HANDLING COMMANDS ? O: T: P: Z; ..... ..... ..... ..... ..... DISPLAY MENU OUTPUT TIMERS/PARAMETERS MODIFY TIMER MODIFY PARAMETER RETURN TO MAIN LEVEL

The commands in this command group are: EGO EGT EGP OUTPUT TIMERS/PARAMETERS MODIFY TIMER MODIFY PARAMETER

DN9813203 Issue 9-0 en

# Nokia Corporation

9 (18)

EG - GSM Timer and BSC Parameter Handling

10 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

EGO OUTPUT TIMERS/PARAMETERS

EGO OUTPUT TIMERS/PARAMETERS


Function

With the command EGO you print out the name, value, preset value, and type of timers and parameters. output category;
EGO: [ <output category> | <all> def ];

Parameters Syntax Parameter explanations

output category
The parameter can have the following values: TIM PAR ALL Displays timers. Displays parameters. Displays all timers and parameters.

The default value is all parameters and timers.


Examples

1.

Display all timers and parameters. ZEGO; or ZEGO:ALL;

2.

Display timers. ZEGO:TIM;

Additional information

The command reads the value of the parameter from the BSC Control Parameter File (PAFILE) and displays them on an output device.

Execution printouts The execution printout for example 2 is the following:


PRESET PARAMETER VALUE VALUE MODIFIABLE -------------------------------- -------------------------------T4 60.00 S 60.00 S YES T7 20.00 S 20.00 S YES T8 12.00 S 12.00 S YES T10 8.00 S 8.00 S YES T13 15.00 S 15.00 S YES

DN9813203 Issue 9-0 en

# Nokia Corporation

11 (18)

EG - GSM Timer and BSC Parameter Handling

T17 T18 T3101 T3103 T3105_D T3105_F T3107 T3109 T3111 T3121 T3122 T3168 T3192 T9101 T9103 T9104 T9105 T9108 T9113 TBBI COMMAND EXECUTED

4.00 12.00 3.00 6.00 0.28 0.10 6.00 12.00 0.50 12.00 6.00 1.00 0.50 10.00 2.00 15.00 10.00 2.00 13.00 15.00

S S S S S S S S S S S S S S S S S S S S

4.00 12.00 3.00 6.00 0.28 0.10 6.00 12.00 0.50 12.00 6.00 1.00 0.50 10.00 2.00 15.00 10.00 2.00 13.00 15.00

S S S S S S S S S S S S S S S S S S S S

YES YES YES YES NO NO YES YES NO YES YES YES YES NO NO YES YES NO YES YES

The values of all timers are displayed in seconds.


Semantic error messages Execution error messages
/*** READING PARAMETER FILE FAILED ***/

If an error occurs, the general semantic error messages of MML commands are printed out.

The MML is unable to read the parameter file.

12 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

EGT MODIFY TIMER

EGT MODIFY TIMER


Function Parameters Syntax

With the command EGT you modify the value of the timer. timer name: time unit, timer value;
EGT: ( <timer name> ) : [ <time unit> | 1 def] , ( <timer value> ) ;

Parameter explanations

timer name
The parameter indicates the timer which is to be modified. The timer names comprises of 1-10 characters. The names of timers are listed in the guidance texts. The parameter is obligatory.

time unit
The parameter, given in a decimal format, indicates which time unit has been used as a value. The parameter can have the following values: 1 2 Value in seconds. Value in 10 milliseconds.

The default value is seconds. For timers T3168 and T3192, the timer unit is either seconds or milliseconds. The values of these timers are decimal values which indicate the timer values from 500 ms to 4 seconds for timer T3168 and from 500 ms to 1.5 seconds for timer T3192 every half second. In these cases, the parameter can have the following values:

DN9813203 Issue 9-0 en

# Nokia Corporation

13 (18)

EG - GSM Timer and BSC Parameter Handling

1 2

Value in seconds. Value in milliseconds.

The default value is seconds.

timer value
The parameter, given in a decimal format, indicates the new value of the timer. The guidance text shows the name, current value, and value range of the timer in the selected time unit. Parts of seconds can only be given by using the 10 milliseconds time unit. The parameter is obligatory.
Examples

1.

Modify the value of T4 to 10 seconds. ZEGT:T4:,10; or ZEGT:T4:1,10;

2.

Modify the value of T3107 to 3.50 seconds. ZEGT:T3107:2,350;

3.

Output the guide for the timer value of timer T3168 in seconds. ZEGT:T3168:1
/* IDENTIFY VALUE OF TIMER T3168 DECIMAL NUMERAL 0 ... 7 0 1 2 3 4 5 6 7 ... ... ... ... ... ... ... ... 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 s s s s s s s s

PARAMETERS CURRENT VALUE IS 1,0 S PARAMETER IS OBLIGATORY */

Additional information

After completion of semantic checks, the MML writes the value to the PAFILE. If this is carried out successfully, the file is updated to the disks. After updating the file, the file is distributed to other units. If these actions are not successfully carried out, the previous value is applied and rewritten to the file.

Execution printouts
COMMAND EXECUTED

14 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

EGT MODIFY TIMER

The MML has updated the new value of the timer to the file.
Semantic error messages Execution error messages
/*** MODIFYING FAILED ***/

If an error occurs, the general semantic error messages of MML commands are printed out.

The MML is unable to modify the timer. The reason for the failure is stored in the log file of the system.
/*** STORING FAILED ***/

The MML is unable to store the value of the timer in the file.
/*** MCMU - 01 NOT UPDATED ***/ /*** BCSU - 02 NOT UPDATED ***/ /*** TRY AGAIN ***/

The units that have not updated the file are listed. You can re-enter the command to update files to units.

DN9813203 Issue 9-0 en

# Nokia Corporation

15 (18)

EG - GSM Timer and BSC Parameter Handling

16 (18)

# Nokia Corporation

DN9813203 Issue 9-0 en

EGP MODIFY PARAMETER

EGP MODIFY PARAMETER


Function Parameters Syntax Parameter explanations

With the command EGP you modify the value of the parameter. parameter number: parameter value;
EGP: ( <parameter number> ) : ( <parameter value> ) ;

parameter number
The parameter indicates the parameter which is to be modified. The names of the parameters and the corresponding numbers are displayed on the output device. The parameter is obligatory.

parameter value
The parameter indicates the new value of the parameter. The name of the parameter, its current value, and the range of the value are displayed. The parameter is obligatory.
Examples

1.

Modify the value of the first parameter to 1. ZEGP:1:1;

2.

Modify the value of the sixth parameter to 1. ZEGP:6:1;

Additional information

After completing semantic checks, the MML writes the value to the PAFILE. If this is carried out successfully, the file is updated to the disks. After updating the file, the file is distributed to other units. If these actions are not successfully carried out, the previous value is applied and rewritten to the file.
COMMAND EXECUTED

Execution printouts

The MML has updated the new value of the parameter to the file.

DN9813203 Issue 9-0 en

# Nokia Corporation

17 (18)

EG - GSM Timer and BSC Parameter Handling

Semantic error messages Execution error messages

If an error occurs, the general semantic error messages of MML commands are printed out.

/*** MODIFYING FAILED ***/

The MML is unable to modify the parameter. The reason for the failure is stored in the log file of the system.
/*** STORING PARAMETER FAILED ***/

The MML is unable to store the value of the parameter in the file.
/*** MCMU - 01 NOT UPDATED ***/ /*** BCSU - 02 NOT UPDATED ***/ /*** TRY AGAIN ***/

The units that have not updated the file are listed. You can re-enter the command to update files to units.

18 (18)