Вы находитесь на странице: 1из 9

1(9)

SIMPOW integrated in NEPLAN


BCP (Busarello+Cott+Partner Inc.) and STRI have integrated the Simpow dynamic analysis modules in the NEPLAN planning and optimization software. Simpow users are now profiting from one of the best planning and optimization software, which provides an advanced graphical interface and the possibility to expand the program package with a lot of different calculation modules such as relay selectivity analysis, reliability analysis and optimal maintenance planning, see the list of modules below. The new integrated version of Simpow in NEPLAN is available from September 2005. The combined package is one of the most complete power system planning and optimization tools on the market. BCP and STRI are also collaborating with support, marketing and sales of their respective software. For further information, please contact BCP or STRI.

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

2(9)

Modules included in NEPLAN:


Graphical Database Editor Load Flow Short Circuit Motor Starting Overcurrent Protection (Selectivity Analysis) Distance Protection Arc Flash Calculation Harmonic Analysis Optimal Separation Points and Network resupply Load Profile Time Simulation Optimization of Distribution Networks Optimal Capacitor Placement Network Reduction Optimal Power Flow Simpow Phasor Mode (Transient Stability) Simpow Instantaneous value Mode (EMT Simulation) Simpow DSL for Primary Components Simpow Linear Analysis, phasor mode Simpow Linear Analysis, instantaneous value mode Simpow DSL Basic and Commands Voltage Stability Available Transfer Capability Analysis (ATC) Cable Sizing (requires modules LF+SC+OCP) Investment Analysis Fault Finding SQL Database Driver SQL Database Converter Interface to SCADA and GIS systems PSS/E Import/Export UCTE Interface Reliability Analysis Optimal Maintenance Planning

Below, see some examples from the integrated version of NEPLAN/Simpow.

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

3(9)
HVDC-Example designed by STRI (Sweden) and BCP (Switzerland)

Turbine and Governor


Gov-76506 TUR-33781

G14 P=0.895 MW Q=-18.922 Mvar

G12 P=0.000 MW Q=-15.000 Mvar

Rectifier Turbine and Exiter


Gov-795070

Inverter
NG14 15.2 kV u=93.14 % Uang=0.00 NG12 13.8 kV u=91.70 % Uang=0.09 GDC2 150 kV u=99.37 % GDC3 150 kV u=98.62 % YGG2AC 123.9 kV u=93.74 % Uang=7.02
P=-0.895 MW Q=18.922 Mvar I= 0.773 kA Ploss=0.024 MW Qloss=0.486 Mvar P=0.000 MW Q=15.000 Mvar I=0.684 kA Ploss=0.015 MW Qloss=0.308 Mvar

VVIK0 135 kV u=113.85 % Uang=0.00


TUR-33777 VVIK02VVIK P=139.673 MW Q=41.935 Mvar I=0.548 kA Ploss= 3.601 MW Qloss=35.559 Mvar

VVIK 135 kV u=106.35 % Uang=-14.03

VVG2AC 123.9 kV u=100.33 % Uang=-20.16


Wik Fir.= 24.26 deg Ratio=0.000 Cntrl= TR2_VVIK Tap=0

GDC1 150 kV u=100.12 %

Ynged Fir.=145.35 deg Ratio=0.000 Cntrl=

P=133.143 MW Q=0.000 Mvar I=0.900 kA Ploss=0.903 MW Qloss=47.863 Mvar P=-135.168 MW Q=0.000 Mvar I=0.900 kA Ploss=0.903 MW Qloss=64.846 Mvar DCLine1 P=135.168 MW I=0.900 kA Ploss=1.013 MW DCLine2 P=134.155 MW I=0.900 kA Ploss=1.012 MW

P=-132.239 MW Q=47.863 Mvar I=0.699 kA Ploss=0.903 MW Qloss=47.863 Mvar

P=132.239 MW Q=-47.863 Mvar I=0.699 kA Ploss= 0.000 MW Qloss=18.838 Mvar

TR2_YGNE Tap=1

P=-132.239 MW Q=66.701 Mvar I=1.141 kA Ploss=0.000 MW Qloss=18.838 Mvar

T1 Tap=0

T2 Tap=0

P=136.072 MW Q= 64.846 Mvar I=0.700 kA Ploss=0.903 MW Qloss=64.846 Mvar P=136.072 MW Q=83.738 Mvar I=0.643 kA Ploss=0.000 MW Qloss=18.892 Mvar P=-136.072 MW Q=-64.846 Mvar I= 0.700 kA Ploss=0.000 MW Qloss=18.892 Mvar

GVVIK P=-139.673 MW Q=-41.935 Mvar

P=-0.001 MW Q=0.000 Mvar I=0.900 kA Ploss=0.903 MW Qloss=64.846 Mvar VVIK1 P=0.000 MW Q=-37.437 Mvar VVIK2 P=0.000 MW Q=-39.925 Mvar

P=-0.001 MW Q=0.000 Mvar I=0.900 kA Ploss=0.903 MW Qloss=47.863 Mvar Shunt P=0.000 MW

P=0.919 MW Q=-18.435 Mvar I=0.142 kA Ploss=0.024 MW Qloss=0.486 Mvar

P=0.015 MW Q =-14.692 Mvar I=0.113 kA Ploss=0.015 MW Qloss=0.308 Mvar

Exiter-33776

GDC_E1 150 kV u=-0.00 %

GDC_E2 150 kV u=0.00 %

YGNE 75 kV u=99.96 % Uang=0.15

DC-75898 P=0.001 MW Q=0.000 Mvar

DC-75911 P=0.001 MW Q=0.000 Mvar

YGNE1 P=0.000 MW Q=-15.488 Mvar

YGNE2 P=0.000 MW Q= -18.086 Mvar

LoadY P=131.304 MW Q=0.000 Mvar

CFC_VVIK

CCA_VVIK

COL_VVIK

MC_VVIK

CFC_YGNE

CCA_YGNE

COL_YGNE

Rectifier

Master

Inverter

HVDC Control System

Single line diagram of an HVDC system

Dialog for the predefined HVDC controllers

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

4(9)

Results of the above HVDC simulation

Results displayed in the NEPLAN chart manager

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

5(9)
Subsynchronous Resonance IEEE Benchmark designed by STRI (Sweden) and BCP (Switerland)

BUSF 500 kV U=495.9 kV Uang=2.75

BUSB 500 kV U=495.9 kV Uang=2.75

BUSC 500 kV U=539.3 kV Uang=-13.21

BUSA 500 kV U=499.1 kV Uang=8.82

BUSGEN 12 kV U=12.0 kV Uang=15.32

Exciter and Inertia


INERTIA-Exciter

BUSFBUSB P=0.0 MW Q=0.0 Mvar

RLC-Element
RLC P=-708.3 MW Q=104.5 Mvar P=709.4 MW Q=-321.0 Mvar BUSCBUSA P=709.4 MW Q=-321.0 Mvar P=-720.0 MW Q=29.1 Mvar

TRAF Tap=0

P=720.0 MW Q=52.6 Mvar

BUSGEN P=-720.0 MW Q=-52.6 Mvar

Turbine and Inertia


INERTIA-Turbine

INF P=708.3 MW Q=-104.5 Mvar

EMT Simulation

NEPLAN single line diagram of the SSR IEEE Benchmark

NEPLAN Dialog for the Exciter and the Inertia of the Turbine.

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

6(9)

Results of the SSR IEEE Benchmark of the simulation in Simpow EMT Simulation mode.

FFT (Fast Fourier Transformation) of the above SSR Result Curve

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

7(9)

IF(START.AND.(.NOT.START0).AND.IDC.EQ/0./.0.)THEN IF(DI.EQ/0./.0.)THEN UCR=UPRE(NODE1) UCI=UPIM(NODE1) UC=SQRT(UCR0**2+UCI0**2) UDIO0=FACY*UC FAC=(U(NODE2)-U(NODE3))/UDIO0 IF(1.-FAC*FAC.LE.0.)THEN FAC1=0. ELSE

NEPLAN Block Diagram of an user defined Exciter and Simpow DSL Language

NEPLAN Dialog for the Simpow Simulation Parameters

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

8(9)

Overcurrent protection example designed by BCP (Switzerland )

Selectivity diagram

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

9(9)

Reliability example designed by BCP (Switzerland )

Frequency and probability of supply interruptions.

STRI AB Box 707 SE-771 80 LUDVIKA Sweden

Business address: Lyviksvgen 8 SE-771 31 LUDVIKA Sweden

Reg.No/VAT SE556314-821101 Phone +46(0)240 795 00 Fax +46(0)240 150 29 info@stri.se www.stri.se

Вам также может понравиться