With the above parameters and the accompanying charts we determine RKM40 by
the following procedure
1. Wet bulb temperature = 75 Deg. F
2. Cooling range = 90 - 82 = 8 Deg. F; Approach temperature = 82 - 75 = 7
Deg. F
3. Selection factor = 5.3 (Selection Factor table, 75 Deg. F wet bulb)
4. From Cooling Tower Capacities table, Model RKM40 can handle 120 GPM at
5.0 selection factor or 136 GPM at 5.5 selection factor. At 5.3, it will handle
approximately 130 GPM.
(back to top)
10
11
12
13
14
15
16
4.1
4.7
5.2
5.7
6.1
6.5
6.9
7.2
7.5
7.8
8.1
8.4
3.7
4.3
4.8
5.2
5.6
6.4
6.7
7.3
7.6
7.9
3.3
3.9
4.4
4.8
5.2
5.6
6.3
6.6
6.9
7.2
7.4
3.6
4.1
4.5
4.9
5.3
5.6
5.9
6.2
6.5
6.8
2.8
3.3
3.8
4.2
4.6
5.3
5.6
5.9
6.2
6.5
6.7
2.6
3.1
3.6
4.4
4.8
5.1
5.4
5.7
6.3
6.5
2.4
2.9
3.3
3.7
4.1
4.5
4.8
5.1
5.4
5.7
6.2
13
14
15
16
17
18
19
20
2.2
2.7
3.1
3.5
3.9
4.2
4.6
4.9
5.2
5.5
5.8
2.5
3.4
3.8
4.1
4.4
4.7
5.3
5.5
5.7
1.9
2.4
2.8
3.2
3.6
3.9
4.2
4.5
4.8
5.1
5.3
5.5
1.8
2.3
2.7
3.1
3.4
3.7
4.3
4.6
4.9
5.2
5.4
1.7
2.2
2.6
3.3
3.6
3.9
4.2
4.5
4.8
5.1
5.2
1.6
2.4
2.8
3.2
3.5
3.8
4.1
4.4
4.6
4.8
1.5
1.9
2.3
2.7
3.1
3.4
3.7
4.3
4.5
4.7
4.9
1.5
1.8
2.2
2.6
3.3
3.6
3.9
4.2
4.4
4.6
4.8
10
11
12
13
14
15
16
5.6
6.1
6.6
7.4
7.8
8.1
8.4
8.5
8.5
8.5
4.6
5.2
5.7
6.1
6.6
6.9
7.3
7.6
7.9
8.2
8.4
8.5
4.3
4.8
5.3
5.8
6.1
6.5
6.9
7.2
7.5
7.8
8.1
8.4
4.5
5.4
5.8
6.2
6.6
6.9
7.1
7.4
7.7
3.7
4.2
4.7
5.1
5.5
5.9
6.2
6.5
6.8
7.1
7.4
7.6
3.5
4.1
4.5
4.9
5.3
5.7
6.3
6.6
6.9
7.1
7.4
3.3
3.8
4.3
4.7
5.1
5.4
5.7
6.3
6.6
6.9
7.1
3.2
3.7
4.1
4.6
4.9
5.2
5.5
5.8
6.1
6.4
6.6
6.9
3.5
3.9
4.3
4.7
5.3
5.6
5.9
6.2
6.4
6.7
2.9
3.3
3.8
4.1
4.5
4.8
5.1
5.4
5.7
6.2
6.5
2.7
3.2
3.6
4.4
4.7
5.3
5.6
5.8
6.1
6.3
2.6
3.1
3.5
3.8
4.2
4.6
4.9
5.2
5.4
5.7
6.2
2.5
3.4
3.7
4.1
4.4
4.7
5.3
5.5
5.8
2.4
2.9
3.3
3.6
4.3
4.6
4.9
5.2
5.4
5.7
5.9
2.3
2.8
3.2
3.5
3.9
4.2
4.5
4.8
5.1
5.3
5.6
5.8
(back to top)
10
11
12
13
14
15
16
5.5
6.1
6.6
7.1
7.5
7.9
8.3
8.5
8.5
8.5
8.5
8.5
5.1
5.7
6.2
6.6
7.4
7.8
8.1
8.4
8.5
8.5
8.5
4.8
5.3
5.8
6.2
6.6
7.4
7.7
8.3
8.5
8.5
4.5
4.9
5.5
5.9
6.3
6.7
7.3
7.6
7.9
8.2
8.4
10
11
12
13
14
15
16
17
18
19
20
4.2
4.7
5.2
5.6
6.4
6.7
7.3
7.6
7.9
8.1
4.5
4.9
5.4
5.7
6.2
6.5
6.8
7.1
7.4
7.6
7.9
3.8
4.3
4.7
5.1
5.5
5.9
6.2
6.5
6.8
7.1
7.3
7.6
3.7
4.2
4.6
5.3
5.7
6.3
6.6
6.9
7.1
7.4
3.5
4.4
4.8
5.1
5.5
5.8
6.1
6.4
6.6
6.9
7.1
3.3
3.8
4.2
4.6
5.3
5.6
5.9
6.2
6.4
6.7
6.9
3.2
3.7
4.1
4.5
4.8
5.2
5.5
5.7
6.3
6.5
6.8
3.1
3.5
4.4
4.7
5.1
5.4
5.6
5.9
6.1
6.3
6.6
3.4
3.9
4.2
4.6
4.9
5.2
5.5
5.8
6.2
6.5
2.9
3.3
3.7
4.1
4.5
4.8
5.1
5.4
5.7
5.9
6.1
6.4
2.8
3.2
3.6
4.4
4.7
5.3
5.6
5.8
6.3
1.5
2 2.5
3 3.5
4.5
5.5
6.5
7.5
8.5
13
15
16
18
21
23
27
30
34
38
44
49
55
63
70
20
22
24
27
30
35
40
45
50
57
66
74
82
90
98
26
30
32
36
42
46
54
60
68
76
88
98
110
110
110
39
45
48
54
63
69
81
90
102
114
132
147
165
189
210
52
60
64
72
84
92
108
120
136
152
176
196
220
240
260
66
74
82
90 102 116
134
150
168
190
220
246
260
260
260
78
90
162
180
204
228
264
294
330
378
400
216
240
272
304
352
392
400
410
420
268
300
336
380
440
492
520
560
600
402
450
504
570
660
738
780
800
825
536
600
672
760
880
648
720
816
864
520 600 640 720 840 920 1080 1200 1360 1520 1760 1960 2000 2050 2100
(back to top)
Model
G
P
M
Dimension Dimensions
Piping-inches
s-in.
-mm
L/Mi
L W H L
n
Piping-mm
No. of
Module
I Ou O D F
OU O D F
s
W H
IN
n t F R V
T F R V
RKM10
34
130
45 33 47
114
119
3 838 4 2
1 50
50
25 25 25
RKM15
52
195
50 33 47
127
119
0 838 4 2
1 50
50
25 25 25
RKM20
70
264
50 46 47
127
119
0 1168 4 2
1 50
50
25 25 25
RKM30
103
390
50 66 47
127
119
0 1676 4 3
1 75
75
50 25 25
RKM40
137
520
50 92 47
127
119
0 2336 4 3
1 75
75
50 50 20
RKM50
160
606
50 88 53
127
134
0 2235 6 3
1 75
75
50 50 20
RKM60
206
780
50 138 47
127
119
0 3504 4 4
10
0 100 50 50 20
RKM80
276
1044 80 88 58
203
147
2 2235 3 4
10
0 100 50 50 20
RKM100
320
1212 50 176 53
127
134
0 4470 6 5
12
7 127 50 50 25
RKM150
480
1818 50 264 53
127
134
0 6705 6 6
15
2 152 50 50 25
RKM200
640
2424 50 352 53
127
134
0 8940 6 6
15
2 152 50 50 25
RKM240
827
3132 80 264 58
203
147
2 6705 3 8
20
3 203 75 75 50
RKM320
110
3
4176 80 352 53
203
147
2 8940 3 8
20
3 203 75 75 50
RKM400
137
9
5220 80 440 58
20
3 203 75 75 50
MODEL
RKM10
RKM15
RKM20
RKM30
RKM40
RKM50
RKM60
Air Flow
CFM
M3/min
3004
85
4240
120
5300
150
8481
240
10601
300
13251
375
15901
450
HP
0.25
0.5
0.5
0.5
0.5
0.5
0.5
Motor
KW Qty
0.2
1
0.37
1
0.37
1
0.37
2
0.37
2
0.37
2
0.37
3
Dry Weight
LBS
KG
187
85
308
140
330
150
550
250
660
300
726
330
990
450
Wet Weight
LBS
KG
420
187
420
187
540
241
840
375
1080
482
1200
535
1620
723
RKM80
RKM100
RKM150
RKM200
RKM240
RKM320
RKM400
18021
26502
39753
53004
54064
72085
90106
510
750
1125
1500
1530
2040
2550
1
0.5
0.5
0.5
1
1
1
0.75
0.37
0.37
0.37
0.75
0.75
0.75
2
4
6
8
6
8
10
1496
1452
2178
2904
4488
5984
7480
680
660
990
1320
2040
2720
3400
2200
2400
3240
4320
6600
8800
12000
981
1070
1445
1927
2944
3925
5352
L = Tower Length
IN = Water Inlet
DR = Drain
FV = Float Valve