CN HOLDING TANK
CN HOLDING TANK
CLARIFIER
EQUALIZATION
TA10
TAD
FINAL pH TANK
DRAIN
Control Panel
PH 3 PH 4 PH 5
BLOWER
MIXER 3
A O M
OFF
ON
MIXER 4
MIXER 5
MIXER 6
MIXER 7
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
DOSING PUMP E
DOSING PUMP F
DOSING PUMP G
DOSING PUMP H
DOSING PUMP I
DESLUDGE PUMP
FILTER PUMP
DIVERTION VALVE
A O M
A O M
A O M
A O M
A O M
A O M
A O M
A O M
CF FEED PUMP A
CF FEED PUMP B
OFF ON
OFF
ON
Setting of Chemical Treatment Tank Chemical Treatment Tank 1 meter pH 3 1. Measured value setting Measured value Checkout time Measure value Off 2. Relay setting Relay adjustment Relay 1: limit 1 Relay 2: limit 2 3. Limit setting Limit 2: upper 6.3 pH limit 1: lower 6.00 pH Limit fault Hyst : 0.20 pH t on: 1 s Control : on Relay 1: limit 1 active closed t on: 0 s t off: 0 s Relay 2: limit 2 active closed t on: 0 s t off: 0 s
Chemical Treatment Tank 2 meter pH 4 4. Measured value setting Measured value Checkout time Measure value Off 5. Relay setting Relay adjustment Relay 1: limit 1 Relay 2: limit 2 6. Limit setting Limit 2: upper 8.5 pH limit 1: lower 8.02 pH Limit fault Hyst : 0.20 pH t on: 1 s Control : on Relay 1: limit 1 active closed t on: 0 s t off: 0 s Relay 2: limit 2 active closed t on: 0 s t off: 0 s
Final pH Tank meter pH 5 7. Measured value setting Measured value Checkout time Measure value Off 8. Relay setting Relay adjustment Relay 1: limit 1 Relay 2: limit 2 9. Limit setting Limit 2: upper 9.0 pH limit 1: upper 8.80 pH Limit fault Hyst : 0.20 pH t on: 1 s Control : on Relay 1: limit 1 active closed t on: 0 s t off: 0 s Relay 2: limit 2 active closed t on: 0 s t off: 0 s
Note: 1. 2. 3. 4. If the pH is out of the limit setting, the particular dosing pump will automatically ON to dose the chemical to adjust the pH to the setting limit If the pH of Chemical Treatment Tank 1 is above pH 6.00, dosing pump E is triggered. If the pH of Chemical Treatment Tank 2 is below pH 8.02, dosing pump F is triggered If the pH of final pH tank is above pH 9.00, dosing pump G is triggered
Sludge Dehydration 1. 2. In a fix interval or when sludge is needed to be pumped out from the Sludge Thickener. Manually turn the Filter Press Feed Pump to ON position. Pressure will slowly increase when the filter press is filling up with sludge. Eventually the pressure will be built up to a limit where the diaphragm pump is unable to run. Manually turn OFF the switch when the Filter Press is full. 3. Proceed to remove the sludge cake from the filter plates