Вы находитесь на странице: 1из 6

www.hilti.

de Company: Specifier: Address: Phone I Fax: E-Mail: Specifier's comments: ATKINS HP -|Anchor desin Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


1 Eseex Waste RH 28-08-2013

1. Input data

Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report:: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile Base material: Installation: Reinforcement:

HIZ (RE 500-SD + Rebar), 20mm h ef,opti = 90 mm (h ef,limit = 120 mm) G30.18 Gr. 400 ETA 07/0260 03-11-2008 | 08-11-2012 design method ETAG BOND; EOTA TR 029 e b = 0 mm (no stand-off); t = 10 mm lx x l y x t = 550 x 950 x 10 mm (Recommended plate thickness: not calculated) IPBi/HEA; (L x W x T x FT) = 133 mm x 140 mm x 9 mm x 9 mm cracked concrete , C30/37, f cc = 37.00 N/mm; h = 170 mm, Temp. short/long: 35/25C hammer drilled hole, installation condition: dry no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm) no longitudinal edge reinforcement Reinforcement to control splitting according to EOTA TR 029, 5.2.2.6 present.

Geometry [mm] y

z 550 3 900 4 x 950 t=10 h ef =90 lx = 550 1 2 x h = 170

500

Loading [kN, kNm] Resulting loads Design loads (Load case 1) N Vx Vy Mx My Mz 20.000 70.000 0.000 0.000 0.000 0.000

Eccentricity (structural section) [mm] e x = 0; e y = 0

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.de Company: Specifier: Address: Phone I Fax: E-Mail: ATKINS HP -|Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


2 Eseex Waste RH 28-08-2013

2. Load case/Resulting anchor forces


Load case (Design loads): Anchor reactions [kN] Tension force: (+Tension, -Compression) Anchor 1 2 3 4 Tension force 5.000 5.000 5.000 5.000 Shear force 17.500 17.500 17.500 17.500 Shear force x 17.500 17.500 17.500 17.500 Shear force y 0.000 0.000 0.000 0.000 Tension x max. concrete compressive strain []: 0.00 max. concrete compressive stress [N/mm]: 0.00 resulting tension force in (x/y)=(0/0) [kN]: 20.000 resulting compression force in (x/y)=(0/0) [kN]: 0.000 3 y 4

3. Tension load (EOTA TR 029, Section 5.2.2)


Proof Steel Strength* Combined pullout-concrete cone failure** Concrete Breakout Strength** Splitting failure** 20.000 N/A 71.226 N/A Load [kN] 5.000 20.000 Capacity [kN] 123.571 61.611

1 Utilization bN [%] 4 32

2 Status OK OK

28 N/A

OK N/A

* most unfavorable anchor **anchor group (anchors in tension) Steel Strength NRk,s [kN] 173.000 g M,s 1.400 NRd,s [kN] 123.571 NSd [kN] 5.000

Combined pullout-concrete cone failure Ap,N [mm ] 291600 yc 1.040 e c1,N [mm] 0 NRk,p [kN] 32.346
0 2

Ap,N [mm ] 72900 t Rk,cr [N/mm ] 5.72 y ec1,Np 1.000 NRk,p [kN] 129.383
2

t Rk,ucr,25 [N/mm ] 11.00 k 2.300 e c2,N [mm] 0 g M,p 2.100

s cr,Np [mm] 270 y g,Np 1.200 y ec2,Np 1.000 NRd,p [kN] 61.611
0

c cr,Np [mm] 135 y g,Np 1.000 y s,Np 1.000 NSd [kN] 20.000

c [mm] 10000

y re,Np 1.000

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.de Company: Specifier: Address: Phone I Fax: E-Mail: ATKINS HP -|Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


3 Eseex Waste RH 28-08-2013

Concrete Breakout Strength Ac,N [mm ] 291600 e c1,N [mm] 0 NRk,c [kN] 37.394
0 2

Ac,N [mm ] 72900 y ec1,N 1.000 g M,c 2.100

c cr,N [mm] 135 e c2,N [mm] 0 NRd,c [kN] 71.226

s cr,N [mm] 270 y ec2,N 1.000 NSd [kN] 20.000 y s,N 1.000 y re,N 1.000 k1 7.200

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.de Company: Specifier: Address: Phone I Fax: E-Mail: ATKINS HP -|Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


4 Eseex Waste RH 28-08-2013

4. Shear load (EOTA TR 029, Section 5.2.3)


Proof Steel Strength (without lever arm)* Steel failure (with lever arm)* Pryout Strength** Concrete edge failure in direction** * most unfavorable anchor **anchor group (relevant anchors) Steel Strength (without lever arm) VRk,s [kN] 86.000 g M,s 1.500 V Rd,s [kN] 57.333 VSd [kN] 17.500 Load [kN] 17.500 N/A 70.000 N/A Capacity [kN] 57.333 N/A 172.511 N/A Utilization bV [%] 31 N/A 41 N/A Status OK N/A OK N/A

Pryout Strength (bond relevant) Ap,N [mm ] 291600 yc 1.040 y s,Np 1.000 NRk,p [kN] 32.346
0 2

Ap,N [mm ] 72900 t Rk,cr [N/mm ] 5.72 e c1,V [mm] 0 NRk,p [kN] 129.383
2

t Rk,ucr,25 [N/mm ] 11.00 k 2.300 y ec1,Np 1.000 gM,c,p 1.500

s cr,Np [mm] 270 k-factor 2.000 e c2,V [mm] 0 VRd,c1 [kN] 172.511

c cr,Np [mm] 135 y g,Np 1.200 y ec2,Np 1.000 VSd [kN] 70.000
0

c [mm] 9075 y g,Np 1.000 y re,Np 1.000

5. Combined tension and shear loads (EOTA TR 029, Section 5.2.4)


bN 0.325 bN + bV <= 1
a a

bV 0.406

a 1.5

Utilization bN,V [%] 44

Status OK

6. Displacements
The displacement of the highest loaded anchor should be calculated according to the relevant approval under the effect of the following characteristic loads. NSk VSk = = 3.704 [kN] 12.963 [kN]

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7. Warnings
Characteristic bond resistances depend on short- and long-term temperatures. Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7! The anchor plate is assumed to be sufficiently stiff in order to be not deformed when subjected to the actions! The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger diameters of the clearance hole see Chapter 1.1. of EOTA TR029!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.de Company: Specifier: Address: Phone I Fax: E-Mail: ATKINS HP -|Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


5 Eseex Waste RH 28-08-2013

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.de Company: Specifier: Address: Phone I Fax: E-Mail: ATKINS HP -|Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.9


6 Eseex Waste RH 28-08-2013

8. Installation data
Anchor plate, steel: Profile: IPBi/HEA, 133 mm x 140 mm x 9 mm x 9 mm Hole diameter in the fixture: df = 20 mm Plate thickness (input): 10 mm Recommended plate thickness: not calculated Cleaning: Premium cleaning of the drilled hole is required Anchor type and diameter: HIZ (RE 500-SD + Rebar), 20mm Installation torque: 0.000 kNm Hole diameter in the base material: 25 mm Hole depth in the base material: 90 mm Minimum thickness of the base material: 140 mm

25.0 475.0

1 25.0 275.0 275.0

2 25.0

Coordinates Anchor [mm] Anchor x y 1 -250 -450 2 250 -450 3 -250 450 4 250 450

c -x -

c +x -

c -y -

c +y -

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

25.0