Вы находитесь на странице: 1из 2

Heterodyne meter resonance (GAD)

http://translate.googleusercontent.com/translate_c?depth=1&...

\ home \ RL construction \ Antenna \ ...

Heterodyne meter resonance (GAD)


The circuit is a heterodyne meter resonance (GAD) of all tested schemes showed the best results. Produced by "Heathkit" as a set of self-assembly.

The construction of several non-trivial scheme, first RF gain, and then full-wave detection. The uneven voltage range is minimized by means of the tuning capacitor. Coils in the primary source of data was not, make them work is not, if you need a stretch band, you can include a capacitor across the coil. The detector will work best Schottky diodes and the diodes work well GD4 series .., .. GD5 . The power switch can be combined with the regulator sensitivity. Powered from any DC 9 volts. Instead, the device can be switched on headphones to listen to. For use as a wavemeter enough to set the potentiometer to the end position for the generation breakdown. IA Well-wishers (UN7GM), un7gm@qsl.net

Popular cry
08.01.2013 11:24 Acquiring GAD-2 ... - UT8IK 23.11.2012 19:11 In the lower text mistake - my call UU6JD, and not UU6LD, ... - VyacheslavUU6JD ... 23.11.2012 18:59 In the address UR3AFJ - would not mind IR-2 instrument - as now ... - Vyacheslav, UU6LD ... 13.06.2012 3:28 Hi Paul, I have a shop manual for GAD-2, com ... - Victor (RU0APX) ... 17.02.2012 6:59 Very need instruction manual GAD-2, I will be very is permissible to recognize ... - Paul 17.02.2012 6:46 Very need instruction manual GAD-2 ... -

1 of 2

Thursday 29 August 2013 02:37 PM

Heterodyne meter resonance (GAD)

http://translate.googleusercontent.com/translate_c?depth=1&...

12.01.2012 8:35 Very harosh device has two nearly new can donate to ... - UR3AFJ 25.12.2011 3:37 ALL ARRANGEMENTS FOR APPLIANCE GAD-2 DESCRIPTION AND ALL IS ALSO CAN peroxide ... - UR3AFJ 04.10.2011 14:16 Schottky diodes are good low dropout. But the frequency response of n ... - ut1wpr 08.06.2011 7:47 desired design but you can repeat and proscheba as the norm ... - Valentine ua3tak ... 17.12.2010 18:50 scheme and instructions ... - Leonid UX5NQ ... 25.11.2010 11:31 Very need instruction manual GAD-2, I will be very is permissible to recognize ... - ra4ndn 25.11.2010 10:40 Instructions GAD-2 ... - ra4ndn 11.01.2010 10:05 gir ... 11.01.2010 10:04 scheme gir ... 14.08.2009 21:00 The scheme GAD-2 I've got Victor UA9LO / 9 ... - UA9LO / 9 Victor ... 26.06.2009 12:46 Need (not sem) and the Regulations under the GAD-2 (LO indicator ... - Albert 30.04.2009 10:22 Gere ... 25.11.2008 8:34 The issue has already been set 14 .11. '08 ... - ua9lka, pl ... 14.11.2008 8:14 Wanted: GAD-1. If anyone has, throw on ua9lka @ mail / yandex .... - ua9lka 27.06.2007 22:43 The scheme can be found here: @ ftp://f68475:Yr0cIcsG ftp.ibox.org.ua / ... - er1caf 19.05.2007 16:11 Please, who has a scheme to "GAD-2" .... Skinte on elektronku ..... - ut5edt 11.11.2006 23:17 Who has a scheme to "GAD-2", produced such. Please read through the Share ... - ra9spf 20.04.2005 16:35 Is there anyone skhma industrial Gere. Produced for radiolyubit ... - ra1qfv

Falcon prices gym .

2 of 2

Thursday 29 August 2013 02:37 PM

Вам также может понравиться