Вы находитесь на странице: 1из 3

9/5/13

Printable Flashcard on API 570 Flashcards: Free Flash cards

API 570 Flashcards


Total Flash Cards 13

1.

In a Positive Material Identification program, a material non-conformance is a test result that:

3.8 material nonconformance: Is not consistent with the specified alloy.

2.

What is the remaining life of a piping system with a short-term corrosion rate of 0.010 in/yr (0.25 mm/yr) and a long-term corrosion rate of 0.005 in/yr (0.13 mm/yr)? A minimum required thickness of 0.150" (3.8 mm), a remaining thickness of 0.210" (5.3 mm), and an original thickness of 0.270" (6.8 mm).

7.1.1 Long-term and short-term corrosion rates should be compared to see which results in the shortest remaining life as part of the data assessment.

3.

How do you evaluate the effects of fire damage on a piping system?

7.4 Utilizing API 579 Fitness-for-Service

4.

The remaining life of a piping system shall be calculated with what formula?

7.1.1 T actual - T minimum / corrosion rate

www.proprofs.com/flashcards/cardshowall.php?title=api-570-flashcards

1/3

9/5/13

Printable Flashcard on API 570 Flashcards: Free Flash cards

5.

The owner-user shall specify industry qualified UT Shear Wave Examiners when:

570 5.10 Trying to detect and size flaws for Fitness-forService evaluation.

578 3.5 level of examination:


6.

What is the level of examination in a Material Verification program?

The specified percentage of the number of components to be examined.

7.

Substituting appropriate NDE procedures for a pressure test after a repair may only be done after:

570 8.2.6 Pressure Testing Consultation with the inspector and the piping engineer.

8.

API RP 579 provides procedures for:

570 5.3.11 API RP 579, Section 3 provides procedures for the assessment of equipment for resistance to brittle fracture.

9.

When positive material identification (PMI) testing is required, portable X-ray fluorescence spectrometer:

578 5.2.1 Portable X-ray Fluorescence cannot be used to detect elements lighter than sulfur (S).

www.proprofs.com/flashcards/cardshowall.php?title=api-570-flashcards

2/3

9/5/13

Printable Flashcard on API 570 Flashcards: Free Flash cards

10.

Piping system corrosion rates shall be calculated on:

7.1.1 Either a short-term or long-term basis

11.

API 578, Material Verification program for new and existing alloy piping systems covers:

4.2.5 Components Covered in a Material Verification Program Process valves (including control valves) and relief valves.

A piping system with a high potential consequence of failure has a corrosion rate of 10 MPY, 0.010 in/yr (0.25 mm/yr), a retirement 12. thickness of .350" (8.9 mm), a required thickness of .250 (6.4 mm), and an actual thickness today of .500" (12.7 mm). What is the remaining life?

7.1.1 Remaining Life Calculations

13.

Piping components identified by PMI as not meeting the original piping specifications:

570 5.8 Would be targeted for replacement.

www.proprofs.com/flashcards/cardshowall.php?title=api-570-flashcards

3/3

Вам также может понравиться