Catalogue Drainage and Sewage

Drainage Pumps

Submersible, Self-priming Pumps and Accessories

Catalogue C1 - 50 Hz - 2009

C1

5 3 6 2 8 9 7 10 12 11 13

Wilo-ComfortVario CO 1 /MVIE

B4

Series Catalogue

10

11

12

13

Wilo-Jet WJ

Wilo-Sub TWI 5-SE P & P

WiloSilentMaster

Wilo-Sub TWU 3

Wilo-RainSystem AF Comfort

Wilo-ComfortVario COR

Wilo-Stratos ECO

Wilo-Safe

Wilo-StarZ 15 TT

WiloDrainLift Con

Wilo-Stratos

Wilo-Drain TM/ TMW 32 Twister

Wilo-DrainLift S

B1

B1

B1

B1

B1

B4

A1

A1

A1

C3

A1

C1

C3

2 3
8

6 4 5 7

8 9

WiloCronoBloc-BL

A3

Series Catalogue

10

10

WiloEMU KS

Wilo-RainSystem AF 150

Wilo-Comfort-Vario COR 4

Wilo-Stratos-D

WiloCronoLine-IL-E

Wilo-TOP-Z

Wilo-Stratos

WiloCronoBloc-BL

WiloDrainLift M

WiloDrainLift WS

C1

B1

B4

A1

A2

A1

A1

A3

C3

C3

Programme overview and fields of application

Drainage pumps
Pump type Free ball passage [mm] Macerator Dry well installation Main field of application

Page

Submersible pumps Wilo-Drain TM/TMW 32 10 10 10 10 10 5 to 45 S S/M/C S/M/C S/M/C M/C S/M/C C C C C C C S M M C 20 25 31 31 31 39

Wilo-Drain TS/TSW 32 Wilo-Drain TS 40 Wilo-Drain TS 50 Wilo-Drain TS 65 Wilo-EMU KS Self-priming pumps Wilo-Drain LP 40 Wilo-Drain LPC

5 6 to 12

S/M/C S/M/C

S/M/C

C C

52 55

Submersible/pedestal pumps (hot water) Wilo-Drain TMT/TMC Wilo-Drain VC 10 5 to 7 C S/M/C C C C M/C 63 67

Key: S M C

Fields of application: Can be used/applicable Cannot be used/not applicable Single- and two-family houses Multi-family house Commercial New in the range or series extension or modification Sewage/faeces Wastewater/drainage Wastewater/coarse contaminants Production sewage Condensate Calorific value/air-conditioning devices

Subject to change without prior notice 03/2007 WILO AG

Pump for basement drainage. Permanently clean pump shaft. No bothering odours. Absolutely reliable.

Wilo-Drain TMW 32 Twister.


Settling sediments in wastewater mostly deposit in the pump shaft and cause odours. This is different in the case of Wilo Drain TMW 32 Twister. Thanks to its patented technology it provides continuous swirlings in the suction area. The settling sediments are automatically and completely pulled into the pump and that is why it remains permanently clean. Enormous? That is what we call Pumpen Intelligenz.

www.wilo.com

twister

Contents

General notes and abbreviations Planning guide Submersible pumps


Wilo-Drain TM/TMW 32 Wilo-Drain TS/TSW 32 Wilo-Drain TS Wilo-EMU KS

6 8 12

Self-priming pumps
Wilo-Drain LP 40 Wilo-Drain LPC

48

Submersible/pedestal pumps (hot water)


Wilo-Drain TMT/TMC Wilo-Drain VC

60
Submersible/pedestal pumps (hot water)

Electrical accessories
Recommended accessories Product descriptions

72

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Self-priming pumps

Submersible pumps

500 answers to FAQs. Used 9000 times in 14 days. 1001 new suggestions. For even more expert knowledge.

The knowledge database from Wilo.


Did you know? The knowledge database from Wilo will give you good and quick advice: with approx. 500 responses to the most frequently asked questions (FAQs) all about pumps, installations and systems. It is already being visited extensively by many skilled craftsmen.This is proven by 9000 utilisations in only 14 days, which we recently registered. The best thing: With every new question which you ask us with the contact form, we all become wiser together. Because the corresponding answer is naturally incorporated as soon as possible. Know-how? We call this Pumpen Intelligenz. www.wilo.com

Drainage pumps
Contents

Submersible pumps
Series overview Wilo-Drain TM/TMW 32 Wilo-Drain TS/TSW 32 Wilo-Drain TS 40, 50, 65 Wilo-EMU KS 12 25 31 39
Submersible pumps
5

20

Self-priming pumps
Series overview Wilo-Drain LP 40 Wilo-Drain LPC 40, 50, 80 48 52 55
Self-priming pumps Electrical accessories Hot water

Submersible/pedestal pumps
Series overview Wilo-Drain TMT/TMC Wilo-Drain VC 60 63 67

Electrical accessories Wilo-Drain


Recommended accessories Product descriptions Switchgear Wilo-EC-Drain 1x4.0 Switchgear Wilo-EC-Drain 2x4.0 Switchgear Wilo-DrainControl PL 1 Switchgear Wilo-DrainControl PL 1 WS Switchgear Wilo-DrainControl PL 2 Switchgear Wilo-DrainControl PL 2 WS Switchgear Wilo-DrainControl 1 / 2 Small alarm switchgear Wilo KAS Wilo Drain-Alarm 2 Alarm switchgears Wilo-AlarmControl 1/2 Motor switchgear/motor protection plug CE Level sensor Float switch MS1 Float switch WA Ex-rated cut-off relay Breakdown barrier Switch cabinet, outdoor installation for Wilo-DrainControl Flash light Signal horn Dynamic pressure system Bubbling-through system Tripping unit Wilo-SK 545 72 79 79 79 80 80 81 81 82 82 82 83 83 83 84 84 84 84 85 85 85 85 86 86

Wilo Catalogue C1 - 50 Hz - Drainage pumps

General notes and abbreviations

Abbreviations and what they mean Abbreviation 1~ 1/min 3~ -A D DI DM DN EBM EM ESM GRD/GLRD H IA IN Inst. LB Meaning 1-phase alternating current Revolutions per minute 3-phase alternating current Float switch attached Direct activation Leakage detection Three-phase motor with direct activation Nominal diameter of the flange connection Individual run signal Single-phase motor with starting capacitor Individual fault signal Mechanical seal Delivery head Starting current Rated current; current at P2 Installation: H = horizontal, V = vertical Readiness for delivery (L = stock article, C = available in 2 weeks, K = available in 4 weeks, A = available on request) Power consumption (power supplied from the mains system) Rated motor power Pressure class in bar (e.g. PN10 = suitable up to 10 bar) Positive temperature coefficient (PTC thermistor sensor) Platinum temperature sensor with a resistance value of 100 : at 0C Volume flow Float switch attached Run signal or collective run signal Fault signal or collective fault signal Thermal winding contacts (in motor for monitoring the winding temperature, full motor protection by additional tripping unit) Star/delta activation Operating mode of double pumps: Individual operation of the respective duty pump Operating mode of double pumps: Parallel operation of both pumps Number of poles of electric motors: 2-pole motor = approx. 2900 1/min at 50 Hz Number of poles of electric motors: 4-pole motor = approx. 1450 1/min at 50 Hz Number of poles of electric motors: 6-pole motor = approx. 950 1/min at 50 Hz

Material designations and their meaning Material 1.4021 1.4057 1.4112 1.4122 1.4301 1.4305 1.4306 1.4308 1.4401 1.4408 1.4462 1.4470 1.4517 1.4541 1.4542 1.4571 1.4581 Abrasite Al Al-oxide C Ceram Composite Cr EN-GJL EN-GJS G-AlSi12 GFK GG GGG Inox PA 30GF Meaning Chrome steel X20Cr13 Chrome steel X17CrNi16-2 Chrome steel X 90 Cr Mo V 18 Chrome steel X39CrMo17-1 Chrome-nickel steel X5CrNi18-10 Chrome-nickel steel X8CrNiS18-9 Chrome-nickel steel X2CrNi19-11 Chrome-nickel steel GX5CrNi19-10 Chrome-nickel-molybdenum steel X5CrNiMo17-12-2 Chrome-nickel-molybdenum steel GX5CrNiMo19-11-2 Chrome-nickel-molybdenum steel X2CrNiMoN22-5-3 Chrome-nickel-molybdenum steel GX2CrNiMoN22-5-3 Chrome-nickel-molybdenum steel with copper addition GX2CrNiMoCuN25-6-3-3 Chrome-nickel steel with titanium addition X6CrNiTi18-10 Chrome-nickel steel with copper and niobium additions X5CrNiCuNb16-4 Chrome-nickel-molybdenum steel with titanium addition X6CrNiMoTi17-12-2 Chrome-nickel-molybdenum steel with niobium addition GX5CrNiMoNb19-11-2 Chilled cast iron for use in highly abrasive fluids Light metal material (aluminium) Aluminium oxide Carbon Ceramic coating; coating with very high adhesive strength, protection against corrosion and abrasion High-strength plastic material Chromium Cast iron (cast iron with lamellar graphite) Cast iron (cast iron with spheroidal graphite, also referred to as spheroidal cast iron) Die-cast aluminium Fibreglass plastic See EN-GJL See EN-GJS Stainless steel See Composite

P1 PN = P2 PN PTC PT 100 Q (=) -S SBM SSM WSK

Y/'

; <   

Subject to change without prior notice 09/2008 WILO SE

General notes and abbreviations

Material PE-HD PP-GF30 PUR SiC St St.vz. V2A (A2) V4A (A4)

Meaning High-density polyethylene Polypropylene, reinforced with 30% fibreglass Polyurethane Silicon carbide Steel Galvanized steel Material group, e.g. 1.4301, 1.4306 Material group, e.g. 1.4404, 1.4571

We do not accept liability for faults or defects arising from natural wear and tear. Wilo General Terms of Delivery and Service The latest version of our General Terms of Delivery and Service can be found on the Internet at www.wilo.com

Wear and tear Pumps or parts of pumps are subject to wear in accordance with the latest technology (DIN 31051/DIN-EN 13306). This wear may vary depending on operating parameters (temperature, pressure, speed, water conditions) and the installation/usage situation and may result in the malfunction or failure at different times of the aforementioned products/components, including their electrical/electronic circuitry. Wearing parts are all components subject to rotary or dynamic stress, including electronic components under tension, in particular: - Seals (incl. mechanical seals), seal rings - Stuffing boxes - Bearings and shafts - Impellers and pump components - Wear rings and counter rings - Stationary wear rings/wear plates - Macerators - Capacitors - Relays/contactors/switches - Electronic circuits, semiconductor components, etc.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Self-priming pumps

Submersible pumps

With pumps and fluid flow machines (such as submersible mixers and recirculation pumps) and their components that have a coating (cataphoretic coating, 2K or ceram coating), this coating is subject to constant wear from the abrasive constituents of the fluid. For this reason, the coating is also among the wearing parts of these units.

Planning guide
Drainage pumps

Both the sewage generated in a building or on a piece of land and the rainwater which accumulates on courtyard and roof surfaces should be pumped to the sewer system with the aid of pumping stations and lifting units, insofar as they do not flow naturally downhill into the local sewage network. There are different ways of disposing this sewage, depending on the respective fluids to be pumped. Wilo submersible pumps and sewage lifting units are designed especially to meet these different requirements and comply with currently valid EN standards. Planning must be carried out in accordance with DIN EN 12050/12056 Drainage systems for buildings and sites. A distinction is made here between sewage emerging from discharge points above the local backflow level, which must be guided to the public sewer system by taking advantage of natural declines, and sewage from discharge points whose water levels in the anti-syphon trap lie below the local backflow level. The backflow level is defined in bylaws. The upper street edge is usually taken as a rough guide value. Sewage (rainwater and wastewater) that accumulates at levels below the backflow level must be pumped to the public sewer system by means of automatically operating lifting units Wilo sewage lifting units or Wilo submersible pumps. According to DIN 1986-100, EN 12050 and EN 12056, the following details are to be observed for system planning and design:

- Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. Acidic sewage must be neutralised. Determining the required pump and/or system output Volume flow Qp [l/s]: Equivalent to the sum of the incoming wastewater QS and the incoming rainwater Qr, which must be determined in accordance with EN 12050/ EN 12056: QS = amount of wastewater [l/s] made up of the sum of all sewage sources, taking simultaneity into account, Qr = amount of rainwater [l/s] as the product of rain yield factor, discharge coefficient and rainfall surface Delivery head Htot [m]: Equivalent to the total height differential between the lowest collecting tank level and the base of the backflow loop + the entire friction losses Hf [m] in the pressure pipe. Attention: When selecting a lifting unit, it is necessary to take into account that the pressure difference between the delivery head at the duty point at nominal flow rate (observe minimum volume flow) and the delivery head at zero volume flow must still amount to approximately 2-3 m in order to open the non-return valve. Operating modes (in accordance with DIN EN 60034-1) S1 = permanent operation The motor temperature increases during operation until it reaches the operating temperature (state of thermal stability). The temperature is dissipated during operation by means of coolant and/or the surrounding fluid. The machine can be operated without interruption while in this status. Specification of the installation type (non-immersed/immersed) and/or of the installation is also to be taken into account. Permanent operation has no effect on this. S1 does not explicitly mean 24 h/day, 7 days/week! Please observe the service life specifications and/or running times per year in the respective documentation. S2 = short-term operation The motor cannot be operated continuously, since the power dissipation that is converted into heat in the motor exceeds the heat dissipation capacity of the cooling unit. The max. operating period is specified in minutes, e.g. S2-15. There must be a pause until the machine temperature does not deviate by more than 2K from the ambient temperature. S3 = intermittent operation This operating mode represents a conventional load for sewage pumps. It describes a relationship between operating time and downtime. Both values must be indicated on the name plate and/or in the installation and operating instructions. For S3 operation, calculations always refer to a period of 10 min. Examples: S3 - 20% means: Operating time 20% of 10 min = 2 min Downtime 80% of 10 min = 8 min S3 - 3 min means: Operating time 3 min Downtime 7 min If 2 values are specified, that means, for example: S3 - 5 min/20 min: Operating time 5 min Downtime 15 min S3 - 25%/20 min: Operating time 5 min Downtime 15 min Additional planning instructions: See Wilo Sewage planning guide (on order).

- Lifting units are to be designed in terms of their performance in such a way that a minimum flow rate of t 0.7 m/s is ensured for the prescribed nominal diameters of the pressure pipe. Prescribed minimum nominal diameters: Sewage lifting unit for sewage containing faeces without comminution unit: DN 80 Sewage lifting unit for sewage containing faeces with comminution unit: DN 32 Sewage lifting unit for sewage free of faeces: DN 32 Sewage lifting unit for limited use for sewage containing faeces without comminution unit: DN 25 Sewage lifting unit for limited use for sewage containing faeces with comminution unit: DN 20 - The pressure pipe of a lifting unit must be equipped with a nonreturn valve and installed with its invert above the backflow level (backflow loop). The pressure pipe may not be connected to wastewater downpipes. - Wastewater gate valves (supply and pressure sides) are to be installed in accordance with DIN 1986-100, EN 12050/EN 12056. - Ventilation pipes for lifting units are to be guided to heights above the roof level; the minimum nominal pipe diameter for sewage lifting units is DN 70. - Feed lines are to be laid with sufficient incline (a minimum of 1:50). - It is practical to install pipes flexibly through masonry. - An automatic standby pump is to be provided if the sewage drain pipe does not allow for interruptions. - Switchboxes and signalling systems are to be installed at a dry, easily accessible position. The signalling system is to be mounted at an observable position. - Lifting units require regular maintenance (at least 1x a year in detached houses, at least 1x every six months in multi-family houses and at least 1x every three months in systems in commercial plants). - The installation area is to be provided with sufficient ventilation and lighting. A working space of at least 600 mm is to be provided above and next to all operating elements and all parts requiring maintenance. The lifting unit must be provided with anti-buoyant mounting.

Subject to change without prior notice 09/2008 WILO SE

Planning guide
Drainage pumps

Wastewater lifting unit (sewage without faeces) in accordance with EN 12050-2


Double pumps Wilo-Drain Twister Double pump drainage station Wilo-Drain Twister 1 Submersible pump (2 x) 2 Pressure pipe DN 32 with Y-piece 3 Non-return valve 4 Backflow loop 5 Backflow level 6 Sewer 7 Switchgear 8 Float switch for level and alarm control Configuration of the backflow loop The backflow loop should not be set up directly in vertical position above the position of the lifting unit if possible. The rest of the sewage pipe is to be laid at an incline down to the connection to the sewer system.
Wastewater/drainage
9

Drainage and sewage lifting unit (sewage with faecal content) in accordance with EN 12050-1
Double system Wilo-DrainLift XXL

12
Ventilation

11
Backflow level (generally upper street edge)

1 2 3 4 5 6 7 8 9 10 11 12 13 14

5 1
Inlet

3 9

10 8 7 6

14

13

Drainage pump

Gate valve DN 100 or DN 150 Flange piece with hose and hose clips DN 100 or DN 150 Flexible hose connection for ventilation Connection kit, tank with pump, 2 gate valves and ventilation flange with hose Diaphragm hand pump 1 " Non-return valve DN 80 or DN 100 Gate valve DN 80 or DN 100 Flange piece with hose and hose clips DN 80 or DN 100 3-way cock Y-pipe DN 80 or DN 100 Microprocessor-controlled switchgear KAS, small alarm switchgear with signalling tone Flexible hose connection for diaphragm hand pump Fitting support for weight relief

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Self-priming pumps

Planning guide
Drainage pumps

Pressure losses in solid pipes

0,4 30,0 [m] 20,0

1,0

2,0

4,0

10

20

40

100

200

400

1000

[m/h]

6000 30,0 [m]

DN20

20,0

DN25
10,0

DN32

DN40

10,0

4,

/s
8,0

8,0 6,0

DN50

3,
0

6,0

DN6

/s
4,0

DN8 DN1 00

4,0

DN1

2,
50 DN1

25

/s
2,0

2,0

/s

DN2 DN2 50

1,

DN3

00

1,0 0,8 0,6

00

1,0

DN3 50

DN4

/s

00

1,

0,8 0,6

DN6

0,4

/s

00

DN5

0,

00

0,4
DN7 00 DN8 DN9 00 DN1 000 00

0,
0,2

/s

0,

0,2

/s

0,1 0,1 0,2 0,4 1,0 2,0 4,0 10 20 40 100 200 400 [l/s] 1000 2000

0,1

10

Subject to change without prior notice 09/2008 WILO SE

Planning guide
Drainage pumps

Pressure losses in hoses


0,1 100 1 10 100 200 Q [m/h] 100
Wastewater/drainage
11

Dv [m]

Dv [m]

/ Ho se A

10

10

1
Electrical accessories

0,1 0,1 1 10 100 200 Q [m/h]

0,1

Q = volume flow; Dv = pressure losses per 100 m hose (kb = 0.25)

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Hot water

Self-priming pumps

m/2 52m m/H ose 63m C m/2 75m m/H ose B

/ 4

/ 5 mm 127

m/1

m/1

m/1

mm

25m

38m

32m

50m

102

152

mm

/ 6

Wastewater / drainage
Submersible pumps

Series overview Wilo-Drain TM/TMW, TS/TSW, TS


Series: Wilo-Drain TM/TMW 32
Wilo-Drain TM/TMW 32

10 8 6 4 2 0 0 14Q[m3/h]

> Basement drainage pump > Application: For pumping clear or slightly muddy water - From tanks, sumps or pits - For overflows and flooding - For draining basement stairways and basement areas

H[m]

10

12

Series: Wilo-Drain TS/TSW 32


Wilo-Drain TS/TSW 32

10 8 6 4 2 0 0 2 4 6 8 10 12 Q[m/h]

> Basement drainage pump > Application: Pumping clear or slightly muddy water - From tanks, sumps or pits - For overflows and flooding - For draining basement stairways and basement areas - From domestic areas (washing machine water, soapsuds) - From small fountains, waterworks or streams

Series: Wilo-Drain TS 40, TS 50, TS 65


Wilo-Drain TS 40 - TS 65

H[m]

24 20 16 TS 50 12 8 4 0
TS

TS 65
40

> Submersible drainage pump > Application: Pumping of wastewater with foreign matter with max. 10 mm, for - House/site drainage - Environmental and water treatment technology - Industrial and process engineering

12

H[m]

0 4 8 12 16 20 24 28 32 36 40 44 48 52 Q[m/h]

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Series overview Wilo-Drain TM/TMW, TS/TSW, TS


Series: Wilo-Drain TM/TMW 32
> Product advantages: Constantly clean pump sump due to patented integrated turbulator (TMW) Vortex hydraulics non-susceptible to clogging No fluid-related odour formation Easy to install High operational reliability Easy operation For aggressive fluids (HD version) > Additional information: Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . Installation example . . . . . . . . . . . . . . Mechanical accessories . . . . . . . . . . . Page 20 21 23 24 24

Series: Wilo-Drain TS/TSW 32


> Product advantages: Permanent operation 4000 hrs/year High-quality motor seal with dirt deflector Heavy-duty, impact-resistant stainless steel housing Detachable connection cable/float cable Easy operation and maintenance Permanently clean pump sump (with TSW) > Additional information: Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical accessories . . . . . . . . . . . Page 25 26 28 29

Series: Wilo-Drain TS 40, TS 50, TS 65


> Product advantages: Inox & composite Detachable connection cable Wide performance range Thermal motor monitoring for 3~, even without switchgear (with TS 40) > Additional information: Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . Terminal diagram . . . . . . . . . . . . . . . . . Mechanical accessories . . . . . . . . . . . Page 31 32 34 35 37

Wilo Catalogue C1 - 50 Hz - Drainage pumps

13

Electrical accessories

Hot water

Self-priming pumps

Submersible pumps

Wastewater / drainage
Submersible pumps

Series overview Wilo-EMU KS


Series: Wilo-EMU KS
Wilo-EMU KS

60 50

EMU
n Tech

40 30 20 10 0 0 50 100 150 200 250 300 Q[m/h]

ologie

> Submersible drainage pump > Application: Pumping of wastewater with foreign matter with max. 45 mm, for - Excavation pits, basins and sumps - Flooded basement areas - Use in fountains

14

H[m]

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Series overview Wilo-EMU KS


Series: Wilo-EMU KS
> Product advantages: Long service life High operational reliability Slurping operation possible Suitable for permanent operation Easy handling > Additional information: Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 39 40 44 45

Wilo Catalogue C1 - 50 Hz - Drainage pumps

15

Electrical accessories

Hot water

Self-priming pumps

Submersible pumps

Wastewater / drainage
Submersible pumps

Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS


Wilo-Drain TM/TMW 32 Operating mode S1 (permanent operation) Motor immersed Motor non-immersed TS/TSW 32 TS 40 TS 50 TS 65

(200 hrs/year)

(4000 hrs/year)

(200 hrs/year)

(200 hrs/year)

(200 hrs/year)

(200 hrs/year)

(4000 hrs/year)

Operating mode S3 (intermittent operation) Operating time [%] Switching frequency/h max. Switching frequency/h recommended Sealing of pumps/motor On pump side: On motor side: Mechanical seal Mechanical seal Rotary shaft seal Oil barrier chamber Design Wet well installation Stationary Portable Submersible Open multi-channel impeller Vortex impeller Turbulator Materials Motor Aluminium casting Stainless steel Pump Plastic Stainless steel Equipment Motor monitoring (temperature) Explosion protection Sheath current cooling Ready-to-plug Connection cable [m] 25 50 20 30 50 20 25 50 20 25 50 20 25 40 20


only TMW

only TSW

only 1~

only 3~ Version A


Version A


3 (10 with TM 32/8 and TMW 32/11 HD) Version: TM 32/7, TMW


10

10

10

10

Connection cable detachable Attached float switch

Version A

Version A

= available or approved, = not available or not approved

16

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Equipment/function Wilo-Drain TM/TMW 32, TS/TSW 32, TS


Wilo-Drain TM/TMW 32 Equipment (continued)
Submersible pumps
17

TS/TSW 32

TS 40

TS 50

TS 65

Integrated non-return valve Non-return valve Capacitor box with 1~230 V Hose connection
= available or approved, = not available or not approved

Version: TMW Enclosed (except TM32/7)

Enclosed

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Self-priming pumps

Wastewater / drainage
Submersible pumps

Equipment/function Wilo-EMU KS
Wilo-EMU KS Operating mode S1 (permanent operation) Motor immersed Motor non-immersed Operating mode S3 (intermittent operation) Operating time [%] Switching frequency/h max. Switching frequency/h recommended Sealing of pumps/motor On pump side: On motor side: Mechanical seal Mechanical seal Rotary shaft seal Oil barrier chamber Design Wet well installation Stationary Portable Submersible Closed multi-channel impeller Open multi-channel impeller Open single-channel impeller Vortex impeller Materials Motor Aluminium casting Cast iron Stainless steel Pump Plastic Cast iron PP-GF30 Bronze Equipment Motor monitoring (temperature) Explosion protection Sheath current cooling Ready-to-plug Connection cable [m] Connection cable detachable
= available or approved, = not available or not approved

15


KS 5, 6, 8, 14, 15, 16, 220 KS 20 KS 9, 12, 24, 37, 70

KS 12, 20 and Ex/GG version

KS 5, 6, 16 KS 2 4

10/20

18

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Equipment/function Wilo-EMU KS
Wilo-EMU KS Equipment (continued) Attached float switch Shock-proof capacitor plug for 1~230 V Capacitor box with 1~230 V
= available or approved, = not available or not approved

Version S
Submersible pumps
19

KS 8, 9, 12, 14, 15

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Self-priming pumps

Wastewater / drainage
Submersible pumps

Series description Wilo-Drain TM/TMW 32

Wilo-Drain TM/TMW
Basement drainage pump

Design
Submersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applications. A residual-current-operated protection switch for a trigger current of 30 mA that is to be provided onsite (regulation concerning installation outdoors) must be used in accordance with EN 60335-2.41. In addition TMW Due to its design, the Wilo-Drain TMW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The maintenance intervals are extended. Deactivating the Twister (see Installation and operating instructions) increases the pump curve by 1 m. Motor Jacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation. Cable In accordance with DIN EN 60335-2-41, an electrical connection cable of 10 m is required for outdoor operation (different regulations apply abroad). Sealing of pumps/motor compartment Mechanical seal on impeller side, one rotary shaft seal on motor side; there is an oil chamber between the seals.

Type key
Example: Wilo-Drain TMW 32/11 HD TMW 32 /11 HD Submersible pump with turbulator Nominal diameter of the pressure port (DN 32) Max. delivery head (m) For aggressive fluids

Application
For pumping clear or slightly muddy water

From tanks, sumps or pits For overflows and flooding For draining basement stairways and basement areas
TMW 32 The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours. Wilo-Drain TMW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimised.

Scope of delivery
Pump ready for connection with cable, plug and attached float switch (except TM 32/8), non-return valve provided (except TM 32/7), installation and operating instructions

20

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TM/TMW 32


Wilo-Drain TM 32/7 Approved fluids
Submersible pumps
21

TM 32/8

TMW 32/8

TMW 32/11

TMW 32/11 HD

Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Fire-fighting water Heating water (Tmax = 35C) Boiler water Condensate Cooling water Clean water Untreated (sewage) water Drainage water Partially desalinated water Rainwater Swimming-pool water Sea water Wastewater Aggressive fluids Power Power consumption P1 1~230 V [kW] Power consumption P1 3~400 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Speed [1/min] Motor Protection class with max. submersion depth Insulation class Switching frequency/h max. Pump Max. noise level at min. level [dBA] Submersion depth, maximum [m] Fluid temperature [C] Fluid temperature, for short periods up to 3 min [C] Cable type
= available or approved, = not available or not approved

0.32 0.25 1.4 2900

0 .5 0.37 2 .2 2900

0.45 0.37 2.1 2900

0.75 0.55 3.6 2900

0.75 0.55 3.6 2900

IP 68 F 60

IP 68 F 60

IP 68 F 60

IP 68 F 60

IP 68 F 60

47 3 3 35 90 H05 RN-F

52 3 3 35 90 H07 RN-F

55 3 3 35 90 H05 RN-F

54 3 3 35 90 H05 RN-F

54 3 3 35 90 H07 RN-F

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Self-priming pumps

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TM/TMW 32


Wilo-Drain TM 32/7 Pump (continued) Cable length [m] Cable cross-section 1~230 V Cable cross-section 3~400 V Plug Type of connection cable Activation type Explosion protection (EEx d II B T4) Free ball passage [mm] Dimensions Pressure port [R/Rp] Hose connection [mm] Weight [kg] Materials Pump housing Impeller Shaft Rotary shaft seal Mechanical seal Motor housing
= available or approved, = not available or not approved

TM 32/8

TMW 32/8

TMW 32/11

TMW 32/11 HD

3 [mm2] [mm2] 3G1 Shock-proof

10 3G1 Shock-proof

3 3G1 Shock-proof

3 3G1 Shock-proof

10 3G1 Shock-proof

Non-detachable Non-detachable Non-detachable Non-detachable Non-detachable Direct 10 Direct 10 Direct 10 Direct 10 Direct 10

1 35 3.8

1 35 5.2

1 4.7

1 6.2

1 6.2

PP-GF30 PP-GF30

PP-GF30 PP-GF30

PP-GF30 PP-GF30 1.4021 (AISI 420)

PP-GF30 PP-GF30

PP-GF30 PP-GF30

on motor side on pump side

NBR Carbon/ceramic

NBR Carbon/ceramic

NBR Carbon/ceramic

NBR Carbon/ceramic

NBR Carbon/ceramic 1.4404 (AISI 316L)

1.4301 (AISI 304)

22

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Pump curves, dimensions, weights Wilo-Drain TM/TMW 32


Wilo-Drain TM /TMW 32
2-pole, 50 Hz
[m]

Wilo-Drain TM/TMW
10

4 3

8 Q

10

12

14

[m3/h]

Dimension drawings
Wilo-Drain TM/TMW 32

1 ~ 230V 50 Hz

D Bmin x Bmin

Dimensions, weights Wilo-Drain Pressure port Hose connection Overall height up to connection L 294 294 293 323 323 Pump diameter D [mm] 35 35 165 165 165 165 165 280 280 330 330 350 350 350 350 14 14 30 30 30 Min. sump dimensions H B [kg] 3.8 5 .2 4.7 6.2 6.2 Min. drainage level Weight

TM 32/7 TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD

G/ Rp 1 1 1 1 1

Wilo Catalogue C1 - 50 Hz - Drainage pumps

23

Electrical accessories

Hot water

Hmin

Self-priming pumps

Submersible pumps

1 = TM 32/7 2 = TMW 32/8 3 = TM 32/8 4 = TMW 32/11

Wastewater / drainage
Submersible pumps

Installation example, mechanical accessories Wilo-Drain TM/TMW 32


Installation example
Schematic diagrams in conjunction with switchgears

Alarm On

On

Peak load

adjustable

Base load and alarm Off Off

Mechanical accessories
Non-return valve Rp 1 with drainage screw, plastic, nominal pressure PN 4 bar

Gate valve set Gate valve, designed as a coupling sleeve slider, female/female thread Rp 1" PN 16 RG,

Double nipple male/male thread 1" x 1", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.

24

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Series description Wilo-Drain TS/TSW 32

Wilo-Drain TS/TSW 32
Basement drainage pump

Design
Submersible pump suitable for stationary, fully automatic operation. A pressure hose of appropriate length is connected for mobile use, while a pipe is connected to the pressure port for stationary applications. A residual-current-operated protection switch for a trigger current of 30 mA that is to be provided onsite (regulation concerning installation outdoors) must be used in accordance with EN 60335-2.41. TSW in addition Due to its design, the Wilo-Drain TSW ensures constant turbulence in the suction area of the pump. This results in a clean pump sump. No fluid-related odours are generated, due to the turbulence and the elimination of the settling sediment connected with it. The maintenance intervals are extended. Motor Jacket-cooled, stainless steel-encapsulated, dry electric motor with built-in thermal overload protection and automatic reactivation. The capacitor is on the inside. Cable In accordance with DIN EN 60335-2-41, an electrical connection cable of 10 m is required for outdoor operation (different regulations apply abroad). Sealing of pumps/motor compartment High operational reliability due to shaft sealing consisting of a mechanical seal on the pump side and a rotary shaft seal on the motor side as well as upstream dirt deflector for additional protection of the mechanical seal, oil barrier chamber.

Type key
Example: Wilo-DrainTS 32/9 A TS 32 /9 A Drainage pump Nominal diameter of pressure port Max. delivery head With float switch

Example: Wilo-DrainTSW 32/11 A TSW 32 /11 A Drainage pump with turbulator Nominal diameter of pressure port Max. delivery head With float switch

Application
For pumping clear or slightly muddy water

TSW The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours. Wilo-Drain TSW 32 has a turbulator that prevents the sediments from depositing by removing it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimised.

Scope of delivery
Pump ready for connection with cable, plug and attached float switch, non-return valve and hose connector ( 32 mm, R1) provided, installation and operating instructions.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

25

Electrical accessories

From tanks, sumps or pits For overflows and flooding For draining basement stairways and basement areas From domestic areas (washing machine water, soapsuds) From small fountains, waterworks or streams

Hot water

Self-priming pumps

Submersible pumps

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TS/TSW 32


Wilo-Drain TS 32/9-A Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Fire-fighting water Heating water (Tmax = 35C) Boiler water Condensate Cooling water Clean water Untreated (sewage) water Drainage water Partially desalinated water Rainwater Swimming-pool water Sea water Wastewater Aggressive fluids Power Power consumption P1 1~230 V [kW] Power consumption P1 3~400 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Speed at 50 Hz [1/min] Motor Protection class with max. submersion depth Insulation class Switching frequency/h max. Pump Max. noise level at min. level [dBA] Submersion depth, maximum [m] Fluid temperature [C] Fluid temperature, for short periods up to 3 min [C] Cable type
= available or approved, = not available or not approved

TS 32/12-A

TSW 32/8-A

TSW 32/11-A

0 .5 0.3 2 .2 2900

0.8 0.6 3.4 2900

0.5 0.3 2.2 2900

0 .9 0.6 3.6 2900

IP 68 B 50

IP 68 B 50

IP 68 B 50

IP 68 B 50

65 10 3-35 90 H07RN-F

65 10 3-35 90 H07RN-F

65 10 3-35 90 H07RN-F

65 10 3-35 90 H07RN-F

26

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TS/TSW 32


Wilo-Drain TS 32/9-A Pump (continued)
Submersible pumps
27

TS 32/12-A

TSW 32/8-A

TSW 32/11-A

Cable length [m] Cable cross-section 1~230 V Cable cross-section 3~400 V Plug Type of connection cable Activation type Explosion protection (EEx d II B T4) Free ball passage [mm] Dimensions Pressure port [R/Rp] Hose connection [mm] Weight [kg] Materials Pump housing Impeller Shaft Rotary shaft seal Mechanical seal Motor housing
= available or approved, = not available or not approved

10 [mm2] [mm2] 3G1 Shock-proof Detachable Direct 10

10 3G1 Shock-proof Detachable Direct 10

10 3G1 Shock-proof Detachable Direct 10

10 3G1 Shock-proof Detachable Direct 10

Rp 1 32, R1 6.8

Rp 1 32 , R 1 7.8

Rp 1 32 , R 1 6.8

Rp 1 32, R1 7.8

PP-GF30 SPS

PP-GF30 SPS

PP-GF30 SPS

PP-GF30 SPS

1.4401 (AISI 316) on motor side on pump side NBR Carbon/ceramic NBR Carbon/ceramic NBR Carbon/ceramic NBR Carbon/ceramic
Hot water Electrical accessories

1.4301 (AISI 304)

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-priming pumps

Wastewater / drainage
Submersible pumps

Pump curves, dimensions, weights Wilo-Drain TS/TSW 32


Wilo-Drain TS 32
2-pole, 50 Hz
12

Wilo-Drain TS/TSW 32

10

H[m]

TSW
TS
4

32/

11

32

TSW
TS 32

/12

32/
/9

8 Q

10

12

14

[m/h]

Dimension drawings

1~230V 50 Hz

Hmin

D 400 x 400

Dimensions, weights Wilo-Drain Hmin TS 32/9-A TS 32/12-A TSW 32/8-A TSW 32/11-A 400 400 400 400 A 246 270 266 290 Dimensions B [mm] 280 300 300 320

A B C

C 320 340 340 360

D 161 171 161 171

28

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Mechanical accessories Wilo-Drain TS/TSW 32


Mechanical accessories
Non-return valve Rp 1 with drainage screw, plastic, nominal pressure PN 4 bar
Submersible pumps

Double nipple male/male thread 1" x 1", for installation of the gate valve directly behind the non-return valve (accessory) on the pressure outlet.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

29

Electrical accessories

Hot water

Self-priming pumps

Gate valve set Gate valve, designed as a coupling sleeve slider, female/female thread Rp 1" PN 16 RG,

52 customer service technicians. Overwhelming availability. 1 telephone number. Everywhere in Germany.

Wilo factory customer service.


The Wilo factory customer service technicians are partners who are there for you with their practical support in all of Germany 365 days a year. Your personal contact partner on site offers you all conceivable support. This local service works so well thanks to our unparalleled organisational structure. Everything comes together in our factory-owned Wilo Service Centre. Based on this, every service call is coordinated perfectly via your personal control centre, and the Wilo customer service technician will be on site to give optimum support with a lot of useful information. Exemplary? We call this Pumpen Intelligenz. www.wilo.com

Wastewater / drainage
Submersible pumps

Series description Wilo-Drain TS 40, TS 50, TS 65


Design
Submersible drainage pump as submersible monobloc unit for vertical wet well installation - Low weight - Detachable, oil-resistant power supply cable - Detachable float switch - Corrosion-resistant Motor: Three-phase asynchronous motor 3~400 V, 50 Hz or single-phase motor 1~230 V, 50 Hz Motor protection: Single-phase current: Three-phase current:

TS 40/

TS ... H

Submersible drainage pump, 2-pole

Type key
Example: Wilo-Drain TS 50 H 111/11 A TS 50 H 111 /11 A Submersible pump (wastewater) Connection 50 (= Rp 2) 65 (= Rp 2 ) Impeller shape: H = half-open impeller Nominal diameter of the impeller [mm] Power P2 [kW] = value/10 = 1.1 kW With float switch, connection cable and plug If not otherwise indicated: Connection cable with bare cable end

Bearing configuration: Bearing of the motor shaft in permanently lubricated, low-maintenance roller bearings. Hydraulics: Half-open impeller with a ball passage of 10 mm. Installation possible without pedestal. With practical vertical pressure port.

Scope of delivery
TS 40, TS 50, TS 65 Pump ready for connection with 10 m connecting cable, if necessary equipped with float switch and plug (version A), hose connection (only TS 40) and installation and operating instructions.
Hot water
31

Additional type key: Example: Wilo-Drain TS 40/10 A TS 40 /10 A Submersible pump (wastewater) Connection 40 (Rp 1 ) Max. delivery head [m] With float switch, connecting cable and plug If not otherwise indicated: Without float switch, bare cable end (only with 3~)

Application
Wilo-Drain TS submersible pumps are well suited for pumping wastewater with foreign matter of max. 10 mm, for - House and site drainage - Environmental and water treatment technology - Industrial and process engineering

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Self-priming pumps

Wilo-Drain TS

Thermal winding contacts (WSK) TS 50, TS 65: Motor protection is to be provided onsite from 1.1 kW and higher = thermal winding contacts (WSK) TS 40: Thermal motor monitoring selfswitching

Submersible pumps

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TS ...


Wilo-Drain TS 40/10 TS 40/10 A Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Fire-fighting water Heating water (Tmax = 35C) Boiler water Cooling water Clean water Untreated (sewage) water Drainage water Partially desalinated water Rainwater Swimming-pool water Wastewater Highly diluted alkaline solutions Mildly aggressive fluids Aggressive fluids Power Power consumption P1 1~230 V [kW] Power consumption P1 3~400 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Speed [1/min] Motor Protection class with max. submersion depth Insulation class Switching frequency [1/h] Pump Max. noise level at min. level [dBA] Submersion depth, maximum [m]
= available or approved, = not available or not approved

TS 40/14 TS 40/14 A

TS 50... TS 50... TS 50... TS 65... H 111/11 (A) H 122/15 (A) H 133/22 (A) H 117/22 (A)

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

0.48 0.55 0.4 2.2 1.1 2900

1.0 0.92 0.75 4.4 2.0 2900

1 .5 1 .5 1 .1 7.7 3.2 2900

2 .0 1 .5 3.6 2900

2.9 2.2 5.1 2900

2.9 2.2 5.1 2900

IP 68 B 50

IP 68 B 50

IP 68 F 50

IP 68 F 50

IP 68 F 50

IP 68 F 40

70 5

70 5

10

10

10

10

32

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Technical data Wilo-Drain TS ...


Wilo-Drain TS 40/10 TS 40/10 A Pump (continued) Fluid temperature [C] Cable type Cable length [m] Cable cross-section 1~230 V Cable cross-section 3~400 V Plug Type of connection cable Activation type Explosion protection (EEx d II B T4) Free ball passage [mm] Dimensions Pressure port [R/Rp] Hose connection [mm] Weight [kg] Materials Pump housing Impeller Shaft Rotary shaft seal on motor side Mechanical seal on motor side Mechanical seal on pump side Static seal Motor housing
= available or approved, = not available or not approved

TS 40/14 TS 40/14 A

TS 50... TS 50... TS 50... TS 65... H 111/11 (A) H 122/15 (A) H 133/22 (A) H 117/22 (A)

3 - 35

3 - 35

3 - 35

3 - 35

3 - 35

3 - 35

OZOFLEX H07 RN-F oil-resistant 10 [mm2] [mm2] 3G1 4G1 10 3G1 4G1 10 3G1 4G1

OZOFLEX (PLUS) H07 RN-F - oil-resistant 10 4G1.5 CEE 10 4G1.5 CEE 10 4G1.5 CEE

Shock-proof (only 1~)

Shock-proof/ CEE

Plug (detachable)
Self-priming pumps
33

Direct 10

Direct 10

Direct only 3~ 10

Direct only 3~ 10

Direct only 3~ 10

Direct

10

1 40 13.0

1 40 16.0

2 21

2 22

2 23

2 24

PP-GF30 PP-GF30

PP-GF30 PP-GF30

PUR PUR

PUR PUR

PUR PUR

PUR PUR
Hot water Electrical accessories

1.4404 (AISI 316L)/1.0402 SiC/SiC SiC/SiC NBR SiC/SiC SiC/SiC NBR NBR SiC/SiC NBR

1.4404 (AISI 316L)/1.0301 NBR SiC/SiC NBR NBR SiC/SiC NBR NBR SiC/SiC NBR

1.4301 (AISI 304)

1.4301 (AISI 304)

Note on Wilo-Drain TS: "A" versions without explosion protection.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Submersible pumps

Wastewater / drainage
Submersible pumps

Pump curves, dimensions, weights Wilo-Drain TS 40


Wilo-Drain TS 40/10, TS 40/14
2-pole, 50 Hz
16

Wilo-Drain TS 40
14 12 10
H [m]

1 = TS 40/10 2 = TS 40/14

8 6 4 2 0 0 2 4 6 8 10 Q 12 14 16 18

[m/h]

Dimension drawing

Dimensions Wilo-Drain a TS 40/10 TS 40/10 A TS 40/14 TS 40/14 A b [mm] 407 424 273 290 245 245 145 145 DN 40/R 1 DN 40/R 1 Dimensions c d e

34

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Pump curves, terminal diagram Wilo-Drain TS 50, TS 65


Wilo-Drain TS 50, TS 65
2-pole, 50 Hz
[m]

Wilo-Drain TS 50-65

24

20

16
H

All pump curves displayed apply to a density of U = 1 kg/dm3

12

0 0 4 8 12 16 20 24 28 Q 32 36 40 44 48 52

[m3/h]

Terminal diagram
1 ~ 230 V, 50 Hz

L1

Float PE SchwimmerL1 swit ch schalter WA WA

PE

< 1,1 kW 3 ~ 400 V, 50 Hz L1 L2 PE L 3 green/yellow

> 1,1 kW 3 ~ 400 V , 50 Hz L1 L2 PE L 3 green/yellow WSK

WSK

To change the direction of rot . ation, swap any 2 phases

To change the direction of rotation, swap any 2 phases

Wilo Catalogue C1 - 50 Hz - Drainage pumps

35

Electrical accessories

Hot water

Self-priming pumps

Submersible pumps

1= TS 50 H 111/11 2= TS 50 H 122/15 3= TS 50 H 133/22 4= TS 65 H 117/22

Wastewater / drainage
Submersible pumps

Dimensions, weights Wilo-Drain TS 50, TS 65


Dimension drawing
Version witmit h ba re cable end Ausfhrung freiem Kabelende Singl e-phase current Wechselstrom Version witSchwimmerschalter h float switch and plug (-A) Ausfhrung mit und Stecker (-A) ThrDrehstrom ee-phase current Singl e-phase current Wechselstrom

150

80

110

80

10 m

150

120

10 m

225

120

80 PG 13 PG 11 PG 13 PG 16-21 PG 11 1m

L6

D 2
D1

Dimensions, weights Wilo Drain Pressure port Rp 2 2 2 2 2 Dimensions L1 360 360 360 387 398 L2 440 440 440 472 483 L6 170 170 170 170 170 D [mm] 128 128 128 138 138 H 132 132 132 132 149 D1 375 375 375 375 375 D2 294 294 294 294 294 Weight [kg] 21 21 22 23 24

TS 50 H 111/11 1~ (A) TS 50 H 111/11 3~ (A) TS 50 H 122/15 3~ (A) TS 50 H 133/22 3~ (A) TS 65 H 117/22 3~ (A)

36

L1

L2

Rp

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Mechanical accessories Wilo-Drain TS ...


Stationary wet well installation
Non-return valve (item 2) TS 40 standard-equipped with integrated non-return valve. TS 40 TS 50 TS 65 R p 1 Rp 2 Rp 2 All female threads GG (EN-GJL) Gate valve (ball valve; item 3) TS 40 TS 50 TS 65 R p 1 Rp 2 Rp 2 Female thread brass, nickel-plated

Portable wet well installation

a b

Hose connection, incl. hose clip (item 12) With TS 40 included in the scope of delivery TS 40 TS 50 TS 65 R1 R2 Rp 2 Plastic Plastic Stainless steel a 40 mm 60 mm 70 mm b 80 mm 90 mm 100 mm All male threads Geka solid coupling (item 19) made of brass TS 40: R 1 male thread

14 oder 20

14 or 20

12,13 13 or 19 12, oder 19

Storz pipe coupling (item 13) made of aluminium, 52-C TS 50 TS 65 G2 G 2 2 Male thread, tappet clearance 66 mm

Storz hose coupling (item 14) Made of aluminium, 52-C, incl. hose clip Tappet clearance 66 mm, for inner hose diameter 52 mm

Wilo Catalogue C1 - 50 Hz - Drainage pumps

37

Electrical accessories

Geka hose coupling (item 20) made of brass, fits Geka solid coupling, incl. hose clip TS 40: for inner hose diameter 40 mm

Hot water

Self-priming pumps

Submersible pumps

Wastewater / drainage
Submersible pumps

38

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Series description Wilo-EMU KS


Design
Submersible pump with double mechanical seal. The design is outstanding due its high wear resistance and general robustness. The electrical drive is sealed off from the pumped fluid by two mechanical seals and one internal oil barrier chamber. The motor compartment is oil-filled.

Scope of delivery
Pump ready for connection with 10 m connecting cable (from KS 24, 20 m) and single-phase current or three-phase current plug, Storz or Geka solid coupling, if necessary 90 pipe bend for implementation of vertical pressure drop, installation and operating instructions.

Accessories
Flange, pressure hose set Storz A, B, C, level switching ZSE or ZSD.

Wilo-EMU KS
Self-priming pumps
39

Single-stage pump for excavation pits

Type key
Example: Wilo-EMU KS 15 E KS Drainage pump 15 Code number for distinguishing between pumps E E = single-phase connection ES = single-phase connection + float switch D = three-phase current DS = three-phase current connection + float switch DMS = three-phase current connection + motor protection + float switch E0 = single-phase connection without plug (bare cable end) D0 = three-phase current connection without plug (bare cable end) Z = centre pressure port H = high-pressure impeller M = medium-pressure impeller N = low-pressure impeller

Application
Pumping of wastewater with foreign matter with max. 45 mm, for - Excavation pits, basins and sumps - Flooded basement areas - Use in fountains

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Submersible pumps

Wastewater / drainage
Submersible pumps

Technical data Wilo-EMU KS


Wilo-EMU KS 5 (Ex) Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Heating water Condensate Cooling water Clean water Drainage water Partially desalinated water Rainwater Swimming-pool water Sea water Wastewater, floodwater and river water Highly diluted alkaline solutions Mildly aggressive fluids Power Power consumption P1 1~230 V [kW] Power consumption P1 3~400 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Speed [1/min] Motor Protection class with max. submersion depth Insulation class Switching frequency [1/h] Pump Submersion depth, maximum [m] Fluid temperature, maximum [C] 10 40 10 40 10 40 10 40 10 35 10 40 10 40 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 1.1 0.75 1.76 2900 1 .1 0.75 1.76 2900 1 .1 1 .1 0.75 5.7 1 .9 2900 1.1 1.1 0.75 5.7 1.9 2900 1.9 1.9 1.3 9.4 3.15 2900 1.1 1.1 0.75 5.7 1.9 2900 1.9 1.9 1.3 9.4 3.2 2900 KS 6 (Ex) KS 8 KS 8 (GG) KS 9 KS 9 (GG) KS 12 KS 14 KS 14 (GG) KS 15 KS 15 (GG)

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

= available or approved, = not available or not approved

40

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Technical data Wilo-EMU KS


Wilo-EMU KS 5 (Ex) Pump (continued) Cable type Cable length [m] Cable cross-section 1~230 V Cable cross-section 3~400 V Type of connection cable Activation type Explosion protection Free ball passage [mm] Dimensions Pressure port [G/Storz] Weight [kg] Materials Pump housing Impeller Shaft Mechanical seal on motor side Mechanical seal on pump side Static seals Motor housing - standard Motor housing - version (GG) SiC/SiC SiC/SiC NBR/Viton SiC/SiC SiC/SiC NBR/Viton Steatite/ carbon SiC/SiC NBR/Viton Aluminium EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 EN-GJL-250 1.4021 (AISI 420) Steatite/ carbon SiC/SiC NBR/Viton Aluminium Steatite/ carbon SiC/SiC NBR EN-GJL-250 Steatite/ carbon SiC/SiC NBR/Viton Aluminium EN-GJL-250 Steatite/ carbon
Hot water
41

KS 6 (Ex)

KS 8 KS 8 (GG)

KS 9 KS 9 (GG)

KS 12

KS 14 KS 14 (GG)

KS 15 KS 15 (GG)

H07 RN-F 10 [mm2] [mm2] 7G1.5 Direct

H07 RN-F 10 7G1.5 Direct

H07 RN-F 10 4G1.5 4G1.5 Detachable/ plug Direct 9

H07 RN-F 10 4G1.5 4G1.5 Detachable/ plug Direct 5

H07 RN-F 10 4G1.5 4G1.5 Detachable/ plug Direct 40

H07 RN-F 10 4G1.5 4G1.5 Detachable/ plug Direct 10

H07 RN-F 10 4G1.5 4G1.5 Detachable/ plug Direct

II 2 G EEx d IIB T4 10 10

1/C 24

1/C 24

1/C 21 (25)

1/C 21 (25)

2/C 28

2/C 21 (25)

2/C 26 (30)

EN-GJL-250 EN-GJL-250

SiC/SiC NBR/Viton Aluminium EN-GJL-250

EN-GJL-250 EN-GJL-250

EN-GJL-250 EN-GJL-250

= available or approved, = not available or not approved

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Self-priming pumps

10

Submersible pumps

Wastewater / drainage
Submersible pumps

Technical data Wilo-EMU KS


Wilo-EMU KS 16 (Ex) KS 20 KS 24 KS 37ZN KS 37ZM KS 37ZH KS 70ZN KS 70ZM KS 70ZH * KS 220

Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Heating water Condensate Cooling water Clean water Drainage water Partially desalinated water Rainwater Swimming-pool water Sea water Wastewater, floodwater and river water Highly diluted alkaline solutions Mildly aggressive fluids Power Power consumption P1 1~230 V [kW] Power consumption P1 3~400 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Speed [1/min] Motor Protection class with max. submersion depth Insulation class Switching frequency [1/h] Pump Submersion depth, maximum [m] Fluid temperature, maximum [C] 10 40 10 35 12 40 12 40 12 40 12 40 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 IP 68 F 15 2.6 2.0 4.5 2900 2 .2 2.8 4.65 2900 2.8 2.4 4.7 2900 4.9 3.7 8.0 2900 8.9 / 9.5 * 7.0 /7.5 * 14.7/ 15.6* 2900 24.4 22 40.5 2900

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions

with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions


with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

with restrictions with restrictions

= available or approved, = not available or not approved

42

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Technical data Wilo-EMU KS


Wilo-EMU KS 16 (Ex) KS 20 KS 24 KS 37ZN KS 37ZM KS 37ZH KS 70ZN KS 70ZM KS 70ZH * KS 220

Cable type Cable length [m] Cable cross-section 1~230 V [mm2] Cable cross-section 3~400 V [mm2] Type of connection cable Activation type Explosion protection Free ball passage [mm] Dimensions Pressure port [G/Storz] Weight [kg] Materials Pump housing Impeller Shaft Mechanical seal on motor side Mechanical seal on pump side Static seals Motor housing - standard Motor housing - version (GG)

H07 RN-F 10 7G1.5 Direct II 2 G EEx d IIB T4 12

H07 RN-F 10 4G1.5 Detachable/ plug Direct 45

H07 RN-F 20 4G1.5 Detachable/ plug Direct 5

NISSHu 20 4G1.5 Detachable Direct 6

NISSHu 20 4G2.5 Detachable Direct 6

H07 RN-F 20 4G6 + 2x 1.0 Detachable Soft starter

10

2/C 30

2 /B 45

3/B 34

4/A 66

4/A 83

6/F 254

EN-GJL-250 EN-GJL-250

EN-GJL-250 EN-GJL-250

EN-GJL-250 EN-GJL-250

EN-GJL-250 EN-GJS500-7

EN-GJL-250 EN-GJS500-7

Aluminium Abrasite

1.4021 (AISI 420) SiC/SiC Carbon/Cr steel SiC/SiC NBR/Viton EN-GJL-250 Carbon/SiC Carbon/SiC SiC/SiC
Hot water
43

Carbon/ aluminium oxide SiC/SiC NBR/Viton Aluminium

SiC/SiC NBR/Viton EN-GJL-250

SiC/SiC NBR/Viton Aluminium

SiC/SiC NBR/Viton Aluminium

SiC/SiC NBR Aluminium

= available or approved, = not available or not approved

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Self-priming pumps

Submersible pumps

Pump (continued)

Wastewater / drainage
Submersible pumps

Pump curves Wilo-EMU KS


Wilo-EMU KS
2-pole, 50 Hz

20 18 16 14 H 12 10 8 6 4 2 2

Wilo-EMU KS 5, 6, 8, 9

1 2 3 4

= KS 5 = KS 6 = KS 8 = KS 9

[m]

1 4 3 16 20 [m/h]

12 Q

20 18 16 14 12 H 10 8 6 4 2

Wilo-EMU KS 12, 14, 15, 16, 20, 24

5 6 7 8 9 10

= KS 12 = KS 1 4 = KS 15 = KS 1 6 = KS 20 = KS 2 4

[m]

9 5 6 7

10

8 40 50
[m/h]

10

20

30 Q

32 28 24 20 H 16 12 8 4 0 0 20 40

Wilo-EMU KS 37 ZN, ZM, ZH

11 = KS 37 ZN 12 = KS 37 ZM 13 = KS 37 ZH

[m]

13 12 60 Q 80 100 11 [m/h]

44

Subject to change without prior notice 09/2008 WILO SE

Wastewater / drainage
Submersible pumps

Pump curves, dimensions Wilo-EMU KS


Wilo-EMU KS
2-pole, 50 Hz

40 35 30 25 H 20 15 10 5 0 0 20 40 60 80 Q 16

15 100 120 140 160

14 [m/h]

Wilo-EMU KS 220 N, MN, MH, H

70 60 50 H 40 30 20 10 19 0 0 50 100 150 20 200 Q 18 250 300 17 350 [m/h]

17 18 19 20

= KS 220 N = KS 220 MN = KS 220 MH = KS 220 H

Dimension drawings
Wilo-EMU KS 5, 6
351 171

Wilo-EMU KS 8, 9

Wilo-EMU KS 12
297 285 163

324

387

G11/4

143

125

G2

265
94 111 66

132

473

40

230

170

Wilo Catalogue C1 - 50 Hz - Drainage pumps

94

152

171

45

Electrical accessories

Hot water

Self-priming pumps

[m]

Submersible pumps

Wilo-EMU KS 70 ZN, ZM, ZH

14 = KS 70 ZN 15 = KS 70 ZM 16 = KS 70 ZH

[m]

Wastewater / drainage
Submersible pumps

Dimensions Wilo-EMU KS

Wilo-EMU KS 14, 15
140

Wilo-EMU KS 16
210

Wilo-EMU KS 20
329

G2
G2 135

58

116

118

138

157

293

195

Wilo-EMU KS 24

Wilo-EMU KS 37

Wilo-EMU KS 70

758

438

455

477

833

145

80

max 408

415

379

644

236

573

295

648

295

Wilo-EMU KS 220

815

780

554

46

843

Subject to change without prior notice 09/2008 WILO SE

719

Wastewater / drainage
Submersible pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

47

Electrical accessories

Hot water

Self-priming pumps

Submersible pumps

Wastewater/drainage
Self-priming pumps

Series overview Wilo-Drain LP, LPC


Series: Wilo-Drain LP 40
Wilo-Drain LP 40

10 8 6 4 2 0 Q[m3/h]

> Self-priming drainage pump > Application: Pumping of wastewater for - Ponds - Sprinkling/spraying of gardens and green areas - Mobile drainage

H[m]
0

10

12

Series: Wilo-Drain LPC


Wilo-Drain LPC

30 25 20 15 10 5 1 0 6 7 8 9 10 15 20 30 40 50 60 80 Q[m/h]

> Self-priming drainage pump > Application: Pumping of wastewater with small amounts of solid matter for - Excavation pits and ponds - Sprinkling/spraying of gardens and green areas - Drainage of seepage water - Mobile drainage

48

H[m]

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Series overview Wilo-Drain LP, LPC


Series: Wilo-Drain LP 40
> Product advantages: High operational reliability Easy handling Easy operation > Additional information: Equipment/function . . . . . . . . . . . . . . Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions, terminal diagram . . . . . . . . . . . . . . . . . Page 50 52 53 54

Series: Wilo-Drain LPC


> Product advantages: Long service life Heavy-duty design Easy handling Easy operation Ease of maintenance Mobile and flexible use > Additional information: Equipment/function . . . . . . . . . . . . . . Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimenson drawings, dimensions . . . . . . . . . . . . . . . . . . . . . . Page 50 55 56 57

Wilo Catalogue C1 - 50 Hz - Drainage pumps

49

Electrical accessories

Hot water

Self-priming pumps

Wastewater/drainage

Wastewater/drainage
Self-priming pumps

Equipment/function Wilo-Drain LP, LPC


Wilo-Drain LP 40 Operating mode S1 (permanent operation) Motor immersed Motor non-immersed Motor air-cooled Operating mode S3 (intermittent operation) Operating time [%] Switching frequency/h max. Switching frequency/h recommended Sealing of pumps/motor On pump side: On motor side: Mechanical seal Mechanical seal Rotary shaft seal Oil barrier chamber Design Wet well installation Stationary Portable Dry well installation Stationary Portable Submersible Closed multi-channel impeller Open multi-channel impeller Open single-channel impeller Vortex impeller Materials Motor Aluminium casting Cast iron Stainless steel Pump Plastic Aluminium casting Cast iron PP-GF30
Brass
= available or approved, = not available or not approved

LPC

only LPC 40

50

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Equipment/function Wilo-Drain LP, LPC


Wilo-Drain LP 40 Equipment Motor monitoring (temperature) Explosion protection Sheath current cooling Ready-to-plug Connection cable [m] Connection cable detachable Oval counter flanges
= available or approved, = not available or not approved Self-priming pumps
Wilo Catalogue C1 - 50 Hz - Drainage pumps 51

LPC

Electrical accessories

Hot water

Wastewater/drainage

Wastewater/drainage
Self-priming pumps

Series description Wilo-Drain LP


Design
Portable self-priming centrifugal pump with vortex impeller, firmly mounted on a low-vibration baseplate made of polypropylene. Maximum suction head 6 m.

Scope of delivery
Pump incl. 2 oval counter flanges with female thread, Rp 1 , carrying handle and installation and operating instructions.

Accessories
Connection cable, 5 m, incl. plug and switch, hose connection set, R 1 , level switch ZSE.

Wilo-Drain LP
Self-priming drainage pump

Type key
Example: Wilo-Drain LP 40/10 LP 40 /10 Self-priming pump (lifting pump) Nominal diameter (DN 40) Maximum delivery head [m]

Application
Pumping of wastewater for - Ponds - Sprinkling/spraying of gardens and green areas - Mobile drainage

52

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Technical data Wilo-Drain LP


Wilo Drain LP 40/10 Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Salty water Heating water Cooling water Clean water Drainage water Rainwater Wastewater, floodwater and river water Highly diluted alkaline solutions Power Power consumption P1 1~230 V [kW] Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Speed [1/min] Motor Protection class Insulation class Pump Fluid temperature [C] Plug (shock-proof) Free ball passage [mm] Dimensions
Electrical accessories
53

Wastewater/drainage Hot water Self-priming pumps

0.55 0.4 2.3 2900

IP 44 B

3 - 35

Pressure port [DN/G] Hose connection [mm] Weight [kg] Materials Pump housing Impeller Shaft Mechanical seal Static seals Motor housing
= available or approved, = not available or not approved

40/1 40 12

Polypropylene Brass 1.4006 (AISI 410)/1.0402 Carbon/ceramic NBR Aluminium

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Wastewater/drainage
Self-priming pumps

Pump curve, dimensions, terminal diagram Wilo-Drain LP


Wilo Drain LP 40/10
2-pole, 50 Hz
[m]

10

Wilo-Drain LP 40/10

H
6 4 2 0 0 2 4 6 Q 8 10 [m3/h]

Dimension drawing

Terminal diagram
1~230 V, 50 Hz
L N PE

54

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Series description Wilo-Drain LPC


Design
This self-priming centrifugal pump is equipped with an open multichannel impeller and integrated non-return valve (only LPC 40). Robust design due to the high-quality cast iron of the impeller and of the pump housing (LPC 40 made of aluminium casting). The stability is ensured by a firm, low-vibration baseplate. The impeller and the pump housing can be cleaned through a small inspection opening (not LPC 40). The long service life of this pump is enabled by the easy replacement of the wearing plate (except for LPC 40). Maximum suction head 7.5 m.

Scope of delivery
Pump with installation and operating instructions.

Wilo-Drain LPC
Self-priming drainage pump

Accessories
Self-priming pumps
55

Type key
Example: LPC 40/19 3-400-50-2 LP C 40 /19 3-400 -50 -2 Self-priming pump (lifting pump) Cast iron Nominal diameter (DN 40) Maximum delivery head [m] Electric motor: 3~400 V Frequency 50 Hz 2-pole

Motor protection switch, stop valves, suction kit consisting of: Hose nozzle, hose, hose clip, hose coupling and foot valve (strainer), trolley for mobile use.

Application
Pumping of wastewater with small amounts of solid matter for - Excavation pits and ponds - Sprinkling/spraying of gardens and green areas - Drainage of seepage water - Mobile drainage

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Hot water

Wastewater/drainage

Wastewater/drainage
Self-priming pumps

Technical data Wilo-Drain LPC


Wilo Drain... LPC 40/19 Approved fluids Washing machine soap and water mixture (without long-fibre constituents) Water from car-washing plants Bath water, unchlorinated Salty water Heating water Cooling water Clean water Drainage water Rainwater Wastewater, floodwater and river water Highly diluted alkaline solutions Power Nominal motor power P2 3~400 V [kW] Nominal current with 3~400 V [A] Speed [1/min] Motor Protection class Insulation class Pump Fluid temperature [C] Plug Free ball passage [mm] Dimensions Pressure port [G] Hose connection [mm] Weight [kg] Materials Pump housing Impeller Shaft Mechanical seal Static seals Motor housing
= available or approved, = not available or not approved

LPC 50/25

LPC 80/29

1.1 4.5 2900

2.2 7.7 2900

4.2 14.2 2900

IP 55 F

IP 55 F

IP 55 F

5 - 80 6

5 - 80 6

5 - 80 12

1A 19 (26)

2 43 (52)

3 75

Aluminium EN-GJL 250

EN-GJL 250 EN-GJL 250 1.4028 (AISI 420F)

EN-GJL 250 EN-GJL 250

Carbon/ aluminium oxide NBR Aluminium

Carbon/ aluminium oxide NBR Aluminium

SiC/SiC NBR Aluminium

56

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Pump curves, dimension drawings, dimensions Wilo-Drain LPC...


Wilo-Drain LPC
2-pole, 50 Hz

Wilo-Drain LPC

30

25

20 H

15

10

2
Self-priming pumps

1 3
1 0 6 7 8 9 10 15 20 Q 30 40 50 60 80 100 [m/h]

Dimension drawing
Wilo-Drain LPC
L1

Dimensions Wilo-Drain Connections DN G1A G2 G3 H 274 311 363 L 397 493 583 L1 73 118 175 P 195 236 283 Dimensions [mm] h X 238 122 249 129 288 190

LPC 40/19 LPC 50/25 LPC 80/29

X1 140 180 210

Y 14 64 95

?d 10 12 14

e 10 14 19

Wilo Catalogue C1 - 50 Hz - Drainage pumps

57

Electrical accessories

4d

X1

Hot water

Wastewater/drainage

[m]

1 = LPC 40/19 2 = LPC 50/25 3 = LPC 80/29

Wastewater/drainage
Self-priming pumps

Mechanical accessories Wilo-Drain LPC


Dimension drawing
Trolley LPC

980

410 620

520 575

58

110

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage
Self-priming pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

59

Electrical accessories

Hot water

Self-priming pumps

Wastewater/drainage

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Series overview Wilo-Drain TMT/TMC, VC


Series: Wilo-Drain TMT/TMC
Wilo-Drain TMT/TMC
> Drainage pumps > Application: For industrial applications, e.g. for condensate, hot water and aggressive fluids.
H[m]

10 8 6 4 2 0 0 4 8 12 16 Q[m3/h]

Series: Wilo-Drain VC
Wilo-Drain VC 32-40
VC 40/20

18 16 14 12 10 8 6 4 2 0 0 2 4 6

VC 32/10 Q[m3/h]

10

12

14

> Vertical drainage pump > Application: Pumping of wastewater: - With solid matter of max. 5 mm or 7 mm (VC 40) - Fluids up to 95C - From pump sumps - With condensate - From basements at risk of flooding

60

H[m]

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Series overview Wilo-Drain TMT/TMC, VC


Series: Wilo-Drain TMT/TMC
> Product advantages: High temperature resistance (up to 95C) Also suitable for aggressive fluids > Additional information: Equipment/function . . . . . . . . . . . . . . Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions, weights . . . . . . . . . . . . . . . . . . . . . . . . . Page 62 63 64 66

Series: Wilo-Drain VC
> Product advantages: Long service life Easy commissioning Connection outside the fluid Long downtimes possible Built-in motor protection via thermal relay and control electrode > Additional information: Equipment/function . . . . . . . . . . . . . . Series description . . . . . . . . . . . . . . . . Technical data . . . . . . . . . . . . . . . . . . . Pump curves, dimensions . . . . . . . . . Page 62 67 68 70

Wilo Catalogue C1 - 50 Hz - Drainage pumps

61

Electrical accessories

Submersible/pedestal pumps (hot water)

Self-priming pumps

Wastewater/drainage

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Equipment/function Wilo-Drain TMT/TMC, VC


Wilo-Drain TMT/TMC Operating mode, intermittent operation S3 Operating time [%] Switching frequency/h max. Switching frequency/h recommended Operating mode, permanent operation S1 Motor submerged Motor air-cooled 25 50 20 25 20 20 VC 32, 40

(2 h/day)

Sealing for pumps/motor On pump side: On motor side: Oil barrier chamber Design Wet well installation Stationary Portable Dry well installation Stationary Submersible Open multi-channel impeller Materials Motor Aluminium casting Stainless steel Bronze Cast iron Pump Cast iron Bronze Equipment Connection cable [m] Attached float switch Capacitor box
= available or approved, = not available or not approved

Mechanical seal Rotary shaft seal

(only pump housing)

(only pump housing)

VC 32, 1~

62

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Series description Wilo-Drain TMT/TMC


Design
Oil-filled, leak-proof encapsulated, noiseless and interference-free three-phase squirrel-cage motor. A residual-current-operated protection switch for a trigger current of 30 mA which is to be provided onsite (regulation concerning outdoor installation) must be used in accordance with EN 60335-2, 41

Scope of delivery
Pump with rigidly connected supply line with bare cable end and installation and operating instructions. Motor protection required onsite.

Wilo-Drain TMT/TMC
Self-priming pumps
63

Drainage pumps

Type key
Example: Wilo-Drain TMC 30-0.5 TM T C 30 -0.5 Submersible pump For hot wastewater up to 95C For industrial wastewater up to 95C Nominal diameter of the pressure port (DN 32) Nominal motor power [kW]

Application
For industrial applications, e.g. for condensate, hot water and aggressive fluids.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Submersible/pedestal pumps (hot water)

Wastewater/drainage

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Technical data Wilo-Drain TMT/TMC


Wilo-Drain TMT 30-0.5 GG Approved fluids Heating water Hot water Boiler water Pump sumps from boiler systems Condensate Drainage water Rainwater Sea water/salty water Wastewater, floodwater and river water Highly diluted alkaline solutions Strong alkaline solutions Mildly aggressive fluids Acidic water Aggressive fluids Power Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Nominal current with 3~230 V [A] Speed [1/min] Motor Protection class Insulation class Pump Submersion depth, maximum [m] Fluid temperature, maximum [C] Cable type Cable length [m] Cable cross-section 3~400 V Plug Type of connection cable Activation type Explosion protection Free ball passage [mm]
= available or approved, = not available or not approved 1) non-immersed

TMC 30-0.5 Bronze

TMC 30-0.7 Niro

0.55 1.9 2870

0.55 1 .9 2870

0.75 1 .9 2870

IP 68 H

IP 68 H

IP 68 H

5 95/65 1) SiAF 5

5 95/65 1) SiAF 5 4 x 1.5 Encapsulated Direct 10

5 95/65 1) SiAF 5 4 x 1 .5 Encapsulated Direct 10

[mm2]

4 x 1.5 Encapsulated Direct 10

64

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Technical data Wilo-Drain TMT/TMC


Wilo-Drain TMT 30-0.5 GG Dimensions Pressure port [DN/Rp] Weight [kg] Materials Pump housing Impeller Shaft Baseplate Lower friction bearing Suction strainer Floater Mechanical seal Static seals Motor housing
= available or approved, = not available or not approved 1) non-immersed

TMC 30-0.5 Bronze

TMC 30-0.7 Niro


Wastewater/drainage
65

1 30

1 33

1 32

EN-GJL-250 EN-GJL-250 1.4122 2-fold, carbon/ceramic F PM EN-GJL-250

G-CuSn 10 G-CuSn 10 1.4122 2-fold, carbon/ceramic FPM G-Cu SN 10

1.4408 1.4408 1.4571 (AISI 316Ti) 1-fold, carbon/ceramic PTFE/Teflon 1.4408

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Submersible/pedestal pumps (hot water)

Self-priming pumps

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Pump curves, dimensions, weights Wilo-Drain TMT/TMC


Wilo-Drain TMT/TMC
2-pole, 50 Hz
[m] 12

Wilo-Drain TMT/TMC

1 = TMT/TMC 30-0.5 2 = TMC 30-0.7

10

8
H

6 2 4 1 2

0 0 0 4 1,0 2,0 8 3,0 Q 12 4,0 16 5,0

[m3/h] [l/s]

Dimension drawing

Dimensions, weights Wilo-Drain Pressure port Rp 1 1 1 Overall height L1 455 455 466 L2 [mm] 388 388 392 Pump ? D 183 183 200 Weight [kg] 30 33 32

TMT 30-0.5 GG TMC 30-0.5 Bronze TMC 30-0.7 Niro

66

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Series description Wilo-Drain VC


Design
Vertical pedestal-type drainage pump and float attached for installation - Completely on flat floors - Shaft always vertical - VC 40 suspended from flange Float switch VC 32: Built into motor VC 40: Disconnected from motor Electrical data VC 32: 1~230 V with capacitor 40 xF VC 40: 3~230/400 V motor protection switch required onsite.

Scope of delivery Wilo-Drain VC


Vertical drainage pump (pedestal pump)
Self-priming pumps
67

Pump with attached float switch and installation and operating instructions.

Type key
Example: Wilo-Drain VC 32/10 VC 32 /10 Vertical drainage pump Nominal diameter of pressure port [mm] Max. delivery head [m]

Application
Pumping of wastewater - With solid matter of max. 5 mm or 7 mm (VC 40) - Fluids up to 95C - From pump sumps - With condensate - From basements at risk of flooding

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Submersible/pedestal pumps (hot water)

Wastewater/drainage

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Technical data Wilo-Drain VC


Wilo Drain VC 32/10 Approved fluids Heating water Hot water Boiler water Pump sumps from boiler systems Condensate Drainage water Rainwater Sea water/salty water Wastewater, floodwater and river water Highly diluted alkaline solutions Washing machine soap and water mixture (without long-fibre constituents) Strong alkaline solutions Mildly aggressive fluids Acidic water Aggressive fluids Power Nominal motor power P2 [kW] Nominal current with 1~230 V [A] Nominal current with 3~400 V [A] Nominal current with 3~230 V [A] Speed [1/min] Motor Protection class Insulation class Pump Submersion depth, maximum [m] Fluid temperature, maximum [C] Cable type Cable length [m] Cable cross-section 3~400 V Plug Type of connection cable Activation type Explosion protection Free ball passage [mm]
= available or approved, = not available or not approved

VC 40/20

0.37 3.65 0.88 1.59 2900

2.20 4.40 7.60 2900

IP 54 F

IP 5 4 F

5 to 95

5 to 95 Direct 7

[mm2]

Direct 5

68

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Technical data Wilo-Drain VC


Wilo Drain VC 32/10 Dimensions Pressure port [R] Weight [kg] Materials Pump housing Impeller Shaft Baseplate Lower friction bearing Suction strainer Floater Mechanical seal Static seals Motor housing
= available or approved, = not available or not approved Submersible/pedestal pumps (hot water)
Wilo Catalogue C1 - 50 Hz - Drainage pumps 69

VC 40/20

1 36

1 75

EN-GJL-250 1.4028 (AISI 420F) Stainless steel EN-GJL-250 G-CuSn 10 Noryl (GFN 3) Polypropylene Aluminium

EN-GJL-250 EN-GJL-250 Stainless steel EN-GJL-250 G-CuSn 10

Polypropylene Aluminium

Electrical accessories

Self-priming pumps

Noryl (GFN 3)

Wastewater/drainage

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Pump curves, dimensions Wilo-Drain VC


Wilo-Drain VC
2-pole, 50 Hz
[m] 20 18 16 14

Wilo-Drain VC

1 = VC 32/10 2 = VC 40/20

12 10 2 8 6 4 2 1 0 0 2 4 6 8 Q 10 12 14 16 [m3/h]

Dimension drawing

Built-in switch

Separate switch

Connecting flange

Dimensions Wilo-Drain Pressure port R 1 1 Dimensions H 1240 1400 P 300 458 H1 1020 1034 ?D [mm] 230 325 160 130 610 740 250 130 141 190 h1 h2 h3 P1

VC 32/10 VC 40/20

70

Subject to change without prior notice 09/2008 WILO SE

Wastewater/drainage (hot water)


Submersible/pedestal pumps

Wilo Catalogue C1 - 50 Hz - Drainage pumps

71

Electrical accessories

Submersible/pedestal pumps (hot water)

Self-priming pumps

Wastewater/drainage

Electrical accessories Wilo-Drain


Drainage pumps

Recommended accessories
Wilo-EC-Drain 1x4.0 1) Wilo-EC-Drain 2x4.0 2) Wilo-DrainControl PL1 1) Wilo-DrainControl PL2 2) Wilo-DrainControl PL1 WS 1) Wilo-DrainControl PL2 WS 2) Wilo-DrainControl 1 1) Wilo-DrainControl 2 2)
o o o o o o o o o

Submersible pumps Wilo-Drain TM/TMW 32 Wilo-Drain TS/TSW 32 Wilo-Drain TS 40 Wilo-Drain TS 50 Wilo-Drain TS 65 Wilo-EMU KS 5, 6 , 16(Ex) Wilo-EMU KS 8 , 9, 12, 14 , 15, 20, 24 Wilo-EMU KS 37 , 70, 220 Wilo-Drain TMT/TMC
= recommended, o = optional, = not required
1)

o o o o o o o o o

o o o o o o o o o

o o o o o o o o o

o o o o o o o o o

o o o o o o o o o

Switchgear for 1 pump, 2 ) Switchgear for 2 pumps

72

Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-Drain


Drainage pumps

Recommended accessories
Motor protection plug CEE Float switch MS1 Wilo-AlarmControl 1 Wilo-Alarm Control 2 Wilo-DrainAlarm 2 Level sensor Float switch WA

Wilo KAS

Submersible pumps Wilo-Drain TM/TMW 32 Wilo-Drain TS /TSW 32 Wilo-Drain TS 40 Wilo-Drain TS 50 Wilo-Drain TS 65 Wilo-EMU KS 5, 6, 16(Ex) Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 Wilo-EMU KS 37 , 70, 220 Wilo-Drain TMT/TMC
= recommended, o = optional, = not required
o o o o o o o o o o o o o o o o o o


o o o o o o o

o o o o o o o o o


o o o o o o o

o o o o o o o o o


o o o o o o o

Wilo Catalogue C1 - 50 Hz - Drainage pumps

73

Electrical accessories

Hot water

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Recommended accessories
Bubbling-through system Dynamic pressure system Ex-rated cut-off relay Breakdown barrier Switch cabinet

Submersible pumps Wilo-Drain TM/TMW 32 Wilo-Drain TS /TSW 32 Wilo-Drain TS 40 Wilo-Drain TS 50 Wilo-Drain TS 65 Wilo-EMU KS 5, 6, 16(Ex) Wilo-EMU KS 8 , 9, 12, 14, 15, 20, 24 Wilo-EMU KS 37 , 70, 220 Wilo-Drain TMT/TMC
= recommended, o = optional, = not required
o o o o o o o o o o o o o o o o o o


o o


o o o

o o o o o o o o o

o o o o o o o o o

74

Subject to change without prior notice 09/2008 WILO SE

Signal horn
o o o o o o o o o

Flash light

Electrical accessories Wilo-Drain


Drainage pumps

Service notice

Wilo Catalogue C1 - 50 Hz - Drainage pumps

75

Electrical accessories

Hot water

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Equipment/function
Wilo-DrainControl 1 Wilo-DrainControl 2 Wilo-DrainControl PL 1/PL 1 WS Wilo-DrainControl PL 2/PL 2 WS Wilo-EC-Drain 1x4.0 Wilo-EC-Drain 2x4.0

Application Switchgear for controlling pumps Alarm switchgear Number of pumps to be controlled Electrical connection Direct activation [A] Star/delta switching Design Microprocessor-controlled Electronic Housing material Plastic Metal Equipment Test run Pump starts counter/impulse counter LC display LED/control lamp Main switch Ampere indicator Voltmeter Adjustable follow-up time Operating hours counter Level measurement Float switch Pneumatic pressure sensor Level sensor (4-20 mA) Electrodes Alarm Mains-dependent Integrated (buzzer) Pump cycling
1) 2) Only for direct activation devices (up to 3) In

Max. 12

Max. 2 x 12

Max. 12

Max. 2 x 12

Max. 10 > 10 A

Max. 2 x 10 > 10 A


(only with PL 1 WS)


(only with PL 2 WS)

2)

2)


3)


3)


3)


3)

3)

3)

4)

4)

4)

4)

For other motor power ratings on request = available, = not available 4 kW) potentially explosive areas only with ex-rated cut-off relay 4) In potentially explosive areas only with breakdown barrier

76

Subject to change without prior notice 09/2008 WILO SE

Wilo KAS

Electrical accessories Wilo-Drain


Drainage pumps

Equipment/function
Wilo-DrainControl 1 Wilo-DrainControl 2 Wilo-DrainControl PL 1/PL 1 WS Wilo-DrainControl PL 2/PL 2 WS Wilo-EC-Drain 1x4.0 Wilo-EC-Drain 2x4.0

Wilo KAS

Message/display function Collective run signal (SBM) Collective fault signal (SSM) Individual run signal (EBM) Individual fault signal (ESM) Control functions (motor monitoring)

PTC Impermeability (DI) Electronic

Optional

Optional

(up to 10 A) (up to 10 A) (from 10 A (from 10 A and higher) and higher)

Motor protection switch

Scope of delivery Float switch Horn


1) For other motor 2) Only for direct


Hot water
77

= available, = not available power ratings on request activation devices (up to 4 kW) 3) In potentially explosive areas only with ex-rated cut-off relay 4) In potentially explosive areas only with breakdown barrier

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Electrical accessories

Self-priming pumps

WSK

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Equipment/function
Wilo-AlarmControl 1 Wilo-AlarmControl 2 Wilo Drain-Alarm 2 Motor protection plug CEE Ex-rated cut-off relay Breakdown barrier

Application Switchgear for controlling pumps Alarm switchgear Number of pumps to be controlled Electrical connection Direct activation [A]

External power section External power section

Star/delta switching

Design Electronic Electromechanical Housing material Plastic Equipment LED/control lamp Level measurement Float switch Pneumatic pressure sensor Level sensor (4-20 mA) Electrodes Alarm Mains-independent Mains-dependent Integrated (buzzer) Socket 1~230 V Message/display function Individual fault signal (ESM) Control functions (motor monitoring) WSK Impermeability (DI) Motor protection switch
= available, = not available

78

Subject to change without prior notice 09/2008 WILO SE

Wilo SK 545 2

Signal horn

Flash light

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Switchgear Wilo-EC-Drain 1x4.0
Electronically controlled switchgear for the automatic, sensor-dependent control of 1 submersible wastewater/sewage pump of the Wilo-Drain series. Full motor protection by integrated motor current monitoring and thermal winding contact evaluation. Lockable main switch Transmitter connection for float switch, type WA 65, WA 95 Button for manual operation of the pump High water alarm Forced activation with high water Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact) Integrated mains-dependent alarm buzzer Operation, high water and malfunction display via LEDs in the front panel Technical data: Operating voltage: 1~230 V, 3~400 V, 3~230 V Connected load P2: 4.0 kW Maximum current: 12 A Frequency: 50/60 Hz Protection class: IP 65 (within buildings/switch cabinets) Dimensions (W x H x D): 215 x 220 x 125 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.

Switchgear Wilo-EC-Drain 2x4.0


Microprocessor-controlled switchgear for the automatic, sensor-dependent control of 2 submersible wastewater/sewage pumps of the Wilo-Drain series. Motor protection by integrated WSK evaluation. Lockable main switch Transmitter connection for float switch, types WA 65, WA 95 and MS1 2 buttons for manual operation of the pumps Adjustable pump kick function for a pump start of 3 sec. after a downtime of 7 days. High water alarm Forced activation with high water Potential-free fault signal (changeover contact) and potential-free run signal (changeover contact) Integrated mains-dependent alarm buzzer Operation, high water and malfunction display via LEDs in the front panel Optionally for controlling explosion-protected pumps Technical data: Operating voltage: 1~230 V, 3~400 V, 3~230 V Connected load P2: 2 x 4.0 kW Maximum current: 2 x 12 A Frequency: 50/60 Hz Protection class: IP 54 Dimensions (W x H x D): 300 x 230 x 113 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling the pump in potentially explosive areas.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

79

Electrical accessories

Hot water

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Switchgear Wilo-DrainControl PL 1
Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors. LC display LED for alarm, operation/follow-up time, manual/automatic mode Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu. Potential-free contacts for collective fault signal and high water alarm Forced activation of the pump Pump deactivation with follow-up time Integrated buzzer Operating hours counter, pump starts Technical data: Operating voltage: 1~230 V, 3~400 V Frequency: 50/60 Hz Protection class: IP 65 (within buildings/switch cabinets) Dimensions (W x H x D): 180 x 255 x 180 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Switchgear Wilo-DrainControl PL 1 WS
Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors. LC display LED for alarm, operation/follow-up time, manual/automatic mode Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu. Potential-free contacts for collective fault signal and high water alarm Forced activation of the pump Pump deactivation with follow-up time Integrated buzzer Operating hours counter, pump starts Lockable main switch 3~mains, no neutral conductor required Technical data: Operating voltage: 1~230 V, 3~400 V Frequency: 50/60 Hz Protection class: IP 65 (within buildings/switch cabinets) Dimensions (W x H x D): 180 x 255 x 180 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

80

Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Switchgear Wilo-DrainControl PL 2
Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors. LCD display, multi-language switching LED for alarm, operation/follow-up time, manual/automatic mode Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-2.5 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu. Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2 Forced activation of the pump Pump deactivation with follow-up time Automatic fault-actuated switchover Integrated buzzer Operating hours counter, pump starts Technical data: Operating voltage: 1~230 V, 3~400 V Frequency: 50/60 Hz Protection class: IP 65 (within buildings/switch cabinets) Dimensions (W x H x D): 320 x 300 x 120 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Switchgear Wilo-DrainControl PL 2 WS
Switchgear for controlling the level of 2 submersible pumps. Level measurement can be carried out using either the bubbling-through or the dynamic pressure system, with float switches or electronic level sensors. LC display, multi-language switching LED for alarm, operation/follow-up time, manual/automatic mode Input terminals for connecting float switches (WA 65, WA 95 or MS1) or for connecting a level sensor (factory setting: level sensor 0-1 mWS (4-20 mA)). Level sensors from 0-1 mWS to 0-5 mWS can be connected as an option. They are set using the switchgear menu. Potential-free contact for collective fault signal and high water alarm, pump malfunction 1, pump malfunction 2 Forced activation of the pump Pump deactivation with follow-up time Automatic fault-actuated switchover Integrated buzzer Operating hours counter, pump starts Lockable main switch 3~mains, no neutral conductor required Technical data: Operating voltage: 1~230 V, 3~400 V Frequency: 50/60 Hz Protection class: IP 65 (within buildings/switch cabinets) Dimensions (W x H x D): 320 x 300 x 120 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for controlling the pump.

Wilo Catalogue C1 - 50 Hz - Drainage pumps

81

Electrical accessories

Hot water

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Switchgear Wilo-DrainControl 1/2
Microprocessor-controlled switchgear for fully automatic control of 1 or 2 submersible wastewater/sewage pumps of the Wilo-Drain series. Manual-0-Automatic switch via keyboard Two-line LCD-display with 2 x 16 characters, multilingual, switchable, menu-driven operating option via keypad Input terminals for connecting a level sensor - Standard: 0 - 2.5 mWs (4-20 mA) - Optional: 0 - 1 mWs (4-20 mA) or 0 - 5 mWs (4-20 mA) Input terminals for connecting the float switches WA 65, WA 95 or MS1 Automatic phase failure and rotating field control Operating hours counter Pump cycling (control 2) after each pumping operation Potential-free contacts for: - Collective fault signal - Horn (NO contact) - Operation of pump 1 (NO contact) - Operation of pump 2 (NO contact) only control 2 Main switch Integrated electronic motor current monitoring Maximum ambient temperature 40C Housing: Plastic for wall-mounted installation Starting mode: Direct or star-delta Technical data: Operating voltage: 1~230 V, 3~400 V, 3~230 V Frequency: 50 Hz Protection class: IP 54 Dimensions (W x H x D): depending on model Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas. A level sensor in the potentially explosive area (with breakdown barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be provided for pump control.

Small alarm switchgear Wilo KAS


Small alarm switchgear with signalling tone 70 dBA, signal transmitter (electrode) with 3 m cable, self-charging power supply unit (battery backup approx. 5 hours) in ISO plug housing (shock-proof), protection class IP 30, 230 V~/9V=; 1.5 VA.

Wilo Drain-Alarm 2
Alarm switchgear for wall-mounted installation with optical and acoustic alarm signals (buzzer) 85 dBA self-charging power supply, potential-free contact, ISO housing, protection class IP 54, 1~230 V. A type WA float switch is required as transmitter.

82

Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Alarm switchgears Wilo-AlarmControl 1/2
Wilo-AlarmControl 1: Mains-independent alarm system with shock-proof plug. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With potentialfree contact and insulated housing IP 20. Wilo-AlarmControl 2: Mains-independent alarm system with shock-proof plug and integrated socket for connecting an appliance, e.g. a washing machine. Rechargeable battery, acoustic alarm signal (buzzer), mini-float switch with 3 m cable mounted on the device. With insulated housing IP 20. Technical data: - Operating voltage: 1~230 V, 50 Hz - Control voltage: 12 VDC (non-stabilised) - Alarm contact with AlarmControl 1: potential-free NO contact, contact load max. 1 A (230 VAC) - Contact socket: Contact load max. 16 A (250 VAC) - Protection class: IP 20 - Housing: ABS - Cable length, mini-float switch: 3 m (2 x 0.75 mm2) - Maximum ambient temperature: + 60C - Dimensions (W x H x D): 68 x 112 x 53 mm Attention: Switchgears are not protected against explosions and may only be used outside of potentially explosive areas.

Motor switchgear/motor protection plug CEE


Motor protection plug (only up to a nominal motor power of P2 < 4 kW) with phase inverter and rotation direction indicator, thermal motor protection of the motor. Power ranges: 1.2 - 1.8 A 1.8 - 2.6 A 2.6 3.7 A 3.7 5.5 A 5 .5 8 A 8 11.5 A Optional with TP 80, TP 100, evaluation of thermal motor protection and leakage detection possible.

Level sensor
For level measurement.

Protection class 68 Measurement range 0 - 1 mWS; 0 - 2.5 mWS Cable lengths 10, 30 or 50 m Output signal 4 - 20 mA ATEX-certified

Wilo Catalogue C1 - 50 Hz - Drainage pumps

83

Electrical accessories

Hot water

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Float switch MS1
Cable length 10 m, for sewage containing faeces, for connection to a Wilo-DrainControl 1 or 2.

Float switch WA
Cable length 5 m, 10 m, 20 m, 30 m, switching: up ON/down OFF.

WA 65 for fluids up to 60C WA 95 for fluids up to 90C

Ex-rated cut-off relay


For the installation of float switches in potentially explosive areas. Suitable for the connection of 2 to 5 float switches. Installed in an ISO housing, protection class IP 54, with transparent cover, for wall-mounted installation. Dimensions (W x H x D): 182 x 180 x 165 mm 2-circuit (connection of 2 float switches possible) 3-circuit (connection of 3 float switches possible) 4-circuit (connection of 4 float switches possible) 5-circuit (connection of 5 float switches possible)
7 8

Breakdown barrier
For the installation of a level sensor in potentially explosive areas. Suitable for the connection of one level sensor. Protection class IP40, housing for installation in non-explosive areas. Dimensions (W x H x D): 75 x 150 x 106 mm 1 m cable premounted.

84

Subject to change without prior notice 09/2008 WILO SE

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Switch cabinet, outdoor installation for Wilo-DrainControl
Empty housing for outdoor installation, made of fibreglass-reinforced polyester, with lock, provided with ventilation and exhaust. For pedestal installation. Additional options such as ammeter, voltmeter, heating, etc. are available on request and can be immediately installed in the switch cabinet in conjunction with a Wilo-DrainControl if desired (additional charge). Dimensions (W x H x D): 590 x 875 x 320 mm

Flash light
For installation on switch cabinets, outdoor installation, 230 VAC

Signal horn
Hot water
85

For connection to Wilo-DrainControl, 230 VAC, 92 dBA

Dynamic pressure system


The pressure sensor (bell) detects changes in the fluid level in the sump. The changes of the pressure value in the bell are transmitted via a leak-proof hose to the Wilo-DrainControl switchgear and evaluated by measuring elements in the switchbox. Scope of delivery: Immersion bell with 10 m hose
Electrical accessories

Wilo Catalogue C1 - 50 Hz - Drainage pumps

Self-priming pumps

Self-priming pumps

Electrical accessories Wilo-Drain


Drainage pumps

Product descriptions
Bubbling-through system
Dynamic pressure system with compressed air permanently introduced by small compressor. The immersion bell (dynamic pressure system) is to be ordered separately. Scope of delivery: Small compressor, 3 m hose, with T-piece and non-return valve

Tripping unit Wilo-SK 545


Tripping unit for monitoring a maximum of 2 Wilo submersible pumpsTP 80 or 100

Installation in existing switchgears or as a module for switchgears of conventional design,


installation on a 35 mm DIN top-hat rail

Monitoring of the rotating field Leakage detection Thermal monitoring (WSK) Operating voltage 3~400 V max. 6 A fuse protection Potential-free output contacts, max. load 250 V, 1 A Dimensions (W x H x D):100 x 72 x 113 mm

86

Subject to change without prior notice 09/2008 WILO SE

Wilo Catalogue Edition 2009


Heating, air-conditioning, cooling Circulation pumps Glandless pumps and accessories, package heat exchanger assembly Catalogue A1 Heating, air-conditioning, cooling Drainage and sewage Water supply

Heating, air-conditioning, cooling Glanded pumps Pumps with in-line design and accessories

Catalogue A2

Heating, air-conditioning, cooling, water supply Monobloc and norm pumps, axial split case pumps Pumps and accessories

Catalogue A3

Water supply Domestic water supply, rainwater utilisation Pumps, systems and accessories

Catalogue B1

Water supply Borehole pumps, 3" to 24" Pumps and systems for building services, domestic, municipal and industrial water supply Water supply High-pressure multistage centrifugal pumps Pumps and accessories

Technologie

EMU

Catalogue B2

Catalogue B3

Water supply Pressure boosting systems Single-pump and multi-pump systems in dry well installations

Catalogue B4

Water supply Sprinkler pumps with VdS approval Borehole pumps and accessories

Technologie

EMU
EMU EMU

Catalogue B5

Drainage and sewage Drainage pumps Submersible pumps, self-priming pumps and accessories

Catalogue C1

Technologie

Drainage and sewage Sewage pumps, DN 32 to DN 600 Submersible pumps and accessories for building services, municipal and industrial applications Drainage and sewage Wastewater and sewage lifting units, pumps stations Pump systems and accessories

Catalogue C2

Technologie

Catalogue C3

Drainage and sewage Submersible mixers Mixers, re-circulation pumps, jet cleaners, grit collector pumps and accessories for municipal application in water treatment systems
3

Technologie

EMU

Catalogue C4

nderungen vorbehalten. WILO AG 09/2007

WILO SE Nortkirchenstrae 100 44263 Dortmund Germany T +49 231 4102-0 F +49 231 4102-7363 wilo@wilo.com www.wilo.com

Wilo International (Subsidiaries)


Argentina WILO SALMSON Argentina S.A. C1295ABI Ciudad Autnoma de Buenos Aires T+ 54 11 4361 5929 info@salmson.com.ar Austria WILO Pumpen sterreich GmbH 1230 Wien T +43 507 507-0 office@wilo.at Azerbaijan WILO Caspian LLC 1065 Baku T +994 12 5962372 info@wilo.az Belarus WILO Bel OOO 220035 Minsk T +375 17 2503393 wilobel@wilo.by Belgium WILO SA/NV 1083 Ganshoren T +32 2 4823333 info@wilo.be Bulgaria WILO Bulgaria Ltd. 1125 Sofia T +359 2 9701970 info@wilo.bg Canada WILO Canada Inc. Calgary, Alberta T2A 5L4 T +1 403 2769456 bill.lowe@wilo-na.com China WILO China Ltd. 101300 Beijing T +86 10 80493900 wilobj@wilo.com.cn Croatia WILO Hrvatska d.o.o. 10090 Zagreb T +38 51 3430914 wilo-hrvatska@wilo.hr Czech Republic WILO Praha s.r.o. 25101 Cestlice T +420 234 098711 info@wilo.cz Denmark WILO Danmark A/S 2690 Karlslunde T +45 70 253312 wilo@wilo.dk Estonia WILO Eesti O 12618 Tallinn T +372 6509780 info@wilo.ee Finland WILO Finland OY 02330 Espoo T +358 207401540 wilo@wilo.fi France WILO S.A.S. 78390 Bois d'Arcy T +33 1 30050930 info@wilo.fr Great Britain WILO (U.K.) Ltd. DE14 2WJ BurtonUpon-Trent T +44 1283 523000 sales@wilo.co.uk Greece WILO Hellas AG 14569 Anixi (Attika) T +302 10 6248300 wilo.info@wilo.gr Hungary WILO Magyarorszg Kft 2045 Trkblint (Budapest) T +36 23 889500 wilo@wilo.hu Ireland WILO Engineering Ltd. Limerick T +353 61 227566 sales@wilo.ie Italy WILO Italia s.r.l. 20068 Peschiera Borromeo (Milano) T +39 25538351 wilo.italia@wilo.it Kazakhstan WILO Central Asia 050002 Almaty T +7 727 2785961 in.pak@wilo.kz Korea WILO Pumps Ltd. 621-807 Gimhae Gyeongnam T +82 55 3405800 wilo@wilo.co.kr Latvia WILO Baltic SIA 1019 Riga T +371 67 145229 mail@wilo.lv Lebanon WILO SALMSON Lebanon 12022030 El Metn T +961 4 722280 wsl@cyberia.net.lb Lithuania WILO Lietuva UAB 03202 Vilnius T +370 5 2136495 mail@wilo.lt The Netherlands WILO Nederland b.v. 1551 NA Westzaan T +31 88 9456 000 info@wilo.nl Norway WILO Norge AS 0975 Oslo T +47 22 804570 wilo@wilo.no Poland WILO Polska Sp. z.o.o. 05-090 Raszyn T +48 22 7026161 wilo@wilo.pl Portugal Bombas Wilo-Salmson Portugal Lda. 4050-040 Porto T +351 22 2080350 bombas@wilo.pt Romania WILO Romania s.r.l. 077040 Com. Chiajna Jud. Ilfov T +40 21 3170164 wilo@wilo.ro Russia WILO Rus ooo 123592 Moscow T +7 495 7810690 wilo@orc.ru Saudi Arabia WILO ME - Riyadh Riyadh 11465 T +966 1 4624430 wshoula@wataniaind.com Serbia and Montenegro WILO Beograd d.o.o. 11000 Beograd T +381 11 2851278 office@wilo.co.yu Slovakia WILO Slovakia s.r.o. 82008 Bratislava 28 T +421 2 45520122 wilo@wilo.sk Slovenia WILO Adriatic d.o.o. 1000 Ljubljana T +386 1 5838130 wilo.adriatic@wilo.si South Africa Salmson South Africa 1610 Edenvale T +27 11 6082780 errol.cornelius@ salmson.co.za Spain WILO Ibrica S.A. 28806 Alcal de Henares (Madrid) T +34 91 8797100 wilo.iberica@wilo.es Sweden WILO Sverige AB 35246 Vxj T +46 470 727600 wilo@wilo.se Switzerland EMB Pumpen AG 4310 Rheinfelden T +41 61 83680-20 info@emb-pumpen.ch Taiwan WILO-EMU Taiwan Co. Ltd. 110 Taipeh T +886 227 391655 nelson.wu@ wiloemutaiwan.com.tw Turkey WILO Pompa Sistemleri San. ve Tic. A.S . 34530 Istanbul T +90 216 6610211 wilo@wilo.com.tr Ukraina WILO Ukraina t.o.w. 01033 Kiew T +38 044 2011870 wilo@wilo.ua Vietnam Pompes Salmson Vietnam Ho Chi Minh-Ville Vietnam T +84 8 8109975 nkm@salmson.com.vn United Arab Emirates WILO ME - Dubai Dubai T +971 4 3453633 info@wilo.com.sa USA WILO-EMU USA LLC Thomasville, Georgia 31792 T +1 229 5840097 info@wilo-emu.com USA WILO USA LLC Melrose Park, Illinois 60160 T +1 708 3389456 mike.easterley@ wilo-na.com

Wilo International (Representation offices)


Algeria Bad Ezzouar, Dar El Beida T +213 21 247979 chabane.hamdad@salmson.fr Armenia 375001 Yerevan T +374 10 544336 info@wilo.am Bosnia and Herzegovina 71000 Sarajevo T +387 33 714510 zeljko.cvjetkovic@wilo.ba Georgia 0179 Tbilisi T +995 32 306375 info@wilo.ge Macedonia 1000 Skopje T +389 2 3122058 valerij.vojneski@wilo.com.mk Mexico 07300 Mexico T +52 55 55863209 roberto.valenzuela@wilo.com.mx Moldova 2012 Chisinau T +373 2 223501 sergiu.zagurean@wilo.md Rep. Mongolia Ulaanbaatar T +976 11 314843 wilo@magicnet.mn Tajikistan 734025 Dushanbe T +992 37 2232908 farhod.rahimov@wilo.tj Turkmenistan 744000 Ashgabad T +993 12 345838 wilo@wilo-tm.info Uzbekistan 100015 Tashkent T +998 71 1206774 info@wilo.uz

March 2009

Subject to change without prior notice. In appliance of our General Terms of Delivery and Service (see www.wilo.com) 2101002

Вам также может понравиться