UNITRONIC® RD-Y(ST)Y / RD-Y(ST)Yv

Type Yv with rein- Process control cable according to DIN/VDE 0815


forced outer sheath

Application MAXI-TERMI-POINT® Cable Make-up


UNITRONIC® RD-Y(St)Y is used Technology RD-Y(St)Y RD-Y(St)Yv
for data transmission in the fields MAXI-TERMI-POINT® wiring is Multi-wired cable of plain Cable make-up like RD-Y(St)Y,
of control centres, controlling also a connecting technology copper, adapted to MAXI- but with reinforced Yv PVC
systems and units. It is without soldering, in which TERMI-POINT®. Core insulation outer sheath.
intended for static wiring or cabels are pressed on a pin by of PVC; cores twisted to pairs,
laying in closed interiors. For a pressing sleeve without prior approx. 20 loops/m, 4 pairs
reasons of cost reduction the insulation. We exclusively use twisted to a unit, units in layers,
multiwired copper cable has impeccably twisted strand of units marked by numbered foil;
been provided for MAXI- seven wires and a PVC- static screen of aluminum
TERMI-POINT® connecting compound (semi-rigid-PVC) laminated plastic foil with
technology. This procedure of especially developed for multi-wired and tinned drain-
wiring (semi-automatic) TERMI-POINT® technology. wire; outer sheath of
considerably reduces the time PVC grey or blue for intrinsi-
and costs required for cally safe systems (similar to
installation. RAL 5015).

Technical Data

Conductor resistance: Coupling: Attenuation:


Minimum bending radius for (loop): <= 73,6 Ohm/km at 800 Hz: <= 200 pF/100m at 1 kHz approx. 1,2 dB/km
static: 20 % of the values, but one value at 10 kHz approx. 3,0 dB/km
7,5 x cable diameter Mutual capacitance: at least, may be up to 400 pF
at 800 Hz : <= 100 nF/km Insulation resistance:
Temperature range: with cables up to 4 double cores Near-end crosstalk attenuation: core/core >= 100 MOhm/km
static: -40°C up to +70°C the values may be exceeded up to up to 10 kHz and 500 m Cable core/screen >= 100 MOhm/km
flexing: -5°C up to +50°C 20 %. length min. 60 dB
Core ident code: Inductance: Peak working voltage:
coloured with RD-Code max. 0,65 mH/km (not for purposes of power/
pair-no.1: a-core: blue high-voltage current): 225 V
b-core: red Characteristic Impedance:
pair-no.2: a-core: grey at 1 kHz approx. 370 Ohm Test voltage:
b-core: yellow at 10 kHz approx. 130 Ohm 50 Hz, 2 min. C/C: 2000 V
pair-no.3: a-core: green 50 Hz, 2 min. C/S: 2000 V
b-core: brown
pair-no.4: a-core: white
b-core: black

Part number No. of pairs No. of Copper weight Outside Approx. weight Part number No. of pairs No. of Copper weight Outside Approx. weight
x diameter units kg/km diameter mm kg/km x diameter units kg/km diameter mm kg/km

UNITRONIC® RD-Y(ST)Y grey 0032 482 12 x 2 x 0,5 3 125 13,5 250


0032 470 2 x 2 x 0,5 - 25 6,5 65 0032 483 16 x 2 x 0,5 4 165 15,5 310
0032 471 4 x 2 x 0,5 1 45 9,0 110 0032 484 24 x 2 x 0,5 6 245 19,0 450
0032 472 8 x 2 x 0,5 2 85 11,5 180 0032 485 32 x 2 x 0,5 8 325 21,0 560
0032 473 12 x 2 x 0,5 3 125 13,5 250 0032 486 48 x 2 x 0,5 12 485 25,5 810
0032 474 16 x 2 x 0,5 4 165 15,5 310 0032 487 96 x 2 x 0,5 24 965 34,0 1570
0032 475 24 x 2 x 0,5 6 245 19,0 450 UNITRONIC® RD-Y(ST)Yv grey
0032 476 32 x 2 x 0,5 8 325 21,0 560 0032 488 2 x 2 x 0,5 - 25 9,0 95
0032 477 48 x 2 x 0,5 12 485 25,5 810 0032 489 4 x 2 x 0,5 1 45 10,5 145
0032 478 96 x 2 x 0,5 24 965 34,0 1570 0032 490 8 x 2 x 0,5 2 85 12,5 240
UNITRONIC® RD-Y(ST)Y blue 0032 491 12 x 2 x 0,5 3 125 15,0 330
0032 479 2 x 2 x 0,5 - 25 6,5 65 0032 492 16 x 2 x 0,5 4 165 17,0 400
0032 480 4 x 2 x 0,5 1 45 9,0 110 0032 493 24 x 2 x 0,5 6 245 20,0 520
0032 481 8 x 2 x 0,5 2 85 11,5 180

No cutting charge for standard stock units (50, 100, 250, 500, 1000 m).
Please state your desired design (e.g. 1 x 500 m drum or 5 x 100 rings). Coils < 30 kg, beyond automatically drums.
Copper base: 150.– Euro/100 kg