Contents
Installation Tools
BBU Hardware a
Appearance of the BBU
WMPT
Preferentially configured in slot 7 in the case of a single WMPT Only configured in slot 2 and slot 3 in the case that the WBBP transmits CPRI signals Preferentially configured in the PWR2 slot Only configured in the FAN slot Configured in slots 0 to 5 Preferentially configured in slot 4 in the case of a single UELP Preferentially configured in slot 4 in the case of a single UFLP Only configured in the PWR1 slot
WBBP
Mandatory
Slots 0 to 5
UPEU
Mandatory
UBFA
Mandatory
UTRP UELP
Optional Optional
5 2
UFLP
Optional
UEIU
Optional
PWR1
BBU Hardware c
Typical Configurations of the BBU
Slots on the BBU panel
Installation Scenarios
On the wall
In the TMC/TMC11H
Installation Procedure
PDU
PWR
Install the CPRI optical cable. a. Insert the optical module into the CPRI0, CPRI1, or CPRI2 port, and then turn outwards the puller on the optical module. b. Insert one end of the CPRI optical cable into the optical module, and then lead the CPRI optical cable out of the cabinet along the right side of the cabinet. c. Wrap the fiber tail with the winding pipe. d. Connect the other end of the CPRI optical cable to the CPRI_W port on the RRU.
Puller Optical module
Winding pipe
d. Thread the E1 cable through the grounding clip. Then, tighten the screw on the grounding clip to make the shielding layer of the E1 cable in full contact with the grounding clip. Finally, connect the PGND cable on the grounding clip to the grounding bolt of the APM30.
Shielding layer of the E1 cable
Grounding clip
10
11
Install the EMUA monitoring signal cable. a. When the MON0 port on the BBU is available, fix the RJ45 connector of the EMUA monitoring signal cable to the MON0 port on the UPEU, and the DB9 connector to the corresponding port on the EMUA.
12
Install the alarm cable. Connect one end of the alarm cable to the EXT-ALM port on the UPEU, and the other end to the associated alarm device.
13
14
CPRI optical cable E1 transfer cable Monitoring signal cable between the HEUA and the BBU BBU power cable E1 cable 15
Connect the orange and white twisted pair to the OUT- and OUT+ on the APMI. Connect the brown and white twisted pair to the alarm wiring terminal of the PSU. Connect the blue and white twisted pair to the door status sensor. Connect the green and white twisted pair to the surge protection alarm wiring terminal on the DCDU-03C. Fix the RJ45 connector to the EXT_ALM port on the BBU. E1 cable BBU power cable E1 transfer cable CPRI optical cable 16
1. 25 mm on the left of the BBU for ventilation 2. 25 mm on the right of the BBU for ventilation 3. 70 mm in front of the BBU for cabling
17
1. The procedure for installing the BBU cables in the 19-inch cabinet is the same as that in the APM30. For details, see pages 814 Installing the BBU cables. 2. For details on the cable connections of the BBU, see page 8 Cable Connections of the BBU.
For details, see page 14 Checking the Power-On Status of the BBU.
18
BBU
DCDU-03C
19
BBU
20
21
RRU power cable CPRI optical cable BBU power cable DCDU-03C PGND cable
1. The procedure for installing the BBU cables is the same as that in the APM30. For details, see pages 814 Installing the BBU cables. 2. For details on the cable connections of the BBU, see page 8 Cable Connections of the BBU.
Slide the BBU case into the PS4890 cabinet. Then, tighten the four M6 screws.
23
CPRI optical cable BBU power cable E1 cable Monitoring signal cable between the PMU and the BBU BBU alarm cable
Connect the BBU power cable to the DC output terminal LOAD6 on the DCDU-03C.
1. The procedure for installing the BBU cables in the PS4890 cabinet is the same as that in the APM30. For details, see pages 814 Installing the BBU cables. 2. For details on the cable connections of the BBU, see page 8 Cable Connections of the BBU.
24
25
26
The procedure for installing the BBU cables in the 48 V DC input scenario is similar to that in the 220 V AC input scenario. The only difference is that the DC input power cable instead of the AC input power cable needs to be installed on site. Routing of the BBU cables:
PGND cable BBU power cable E1 cable E1 transfer cable CPRI optical cable DC input power cable
27
Slide the BBU into the TMC. Then, tighten the four M6 screws. CPRI optical cable E1 cable E1 transfer cable TMC monitoring signal cable BBU power cable
1. The procedure for installing the BBU cables in the TMC is the same as that in the APM30. For details, see pages 814 Installing the BBU cables. 2. For details on the cable connections of the BBU, see page 8 Cable Connections of the BBU. 28
29
CPRI optical cable E1 cable E1 transfer cable BBU power cable Monitoring signal cable between the HEUA and the BBU
1. The procedure for installing the BBU cables in the TMC is the same as that in the APM30. For details, see pages 814 Installing the BBU cables. 2. For details on the cable connections of the BBU, see page 8 Cable Connections of the BBU.
30
Reference
a
Cable PGND cable
Cable List
Connector OT terminal OT terminal Connects to Grounding bolt of the BBU3900 Protection grounding bar
3V3 connector Bare wire. The connector needs to be made on site according to the field requirements. (The following figure shows the BBU power cable by taking OT terminals as an example.)
DLC connector
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI3 ports on the WBBP
DLC connector
E1 cable
E1/T1 port on the GTMU or WMPT, or OUTSIDE port on the UELP Peer device
31
Reference
c a
Cable List
Connector DB26 male connector DB25 male connector Connects to PWR port on the UPEU E1/T1 port on the GTMU or WMPT Cable E1 transfer cable
FE cable
FE transfer cable
FE0 port on the WMPT FE0 port near the INSIDE label on the UFLP
32
Reference
a
Cable List
Connector Connected before delivery RJ45 connector MON1 port on the UPEU Connects to APMI
Cable Monitoring signal cable between the APMI and the BBU
RJ45 connector
Alarm cable
RJ45 connector
RJ45 connector
33
Reference b
Engineering Specifications of the BBU
Item Dimensions Weight Input voltage Specification 86 mm (height) x 442 mm (width) x 310 mm (length) Typical configuration: 7 kg; full configuration: 11 kg 48 V DC or +24 V DC
Check the DIP switch settings of the WMPT, GTMU, UTRP, and UELP.
Wear an ESD wrist strap or a pair of ESD gloves when performing operations related to the boards, as shown in the figure below.
ESD strap
ESD gloves
34
Reference
c
Setting the DIP Switches
Set the DIP switches of the BBU. Settings of the DIP switches on the UELP
35
Reference c
Setting the DIP Switches
Reinstall the boards.
ed
Reference d
Pin Assignment of the BBU Signal Cables
120-ohm E1 cable Pin on the DB26 Male Connector X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.19 X1.20 X1.21 X1.22 X1.23 X1.24 X1.25 X1.26 Blue Twisted pair White Orange White Green Twisted pair White Brown Twisted pair White Grey Twisted pair White Blue Twisted pair Red Orange Twisted pair Red Green Twisted pair Red TX4TX3TX4+ TX2TX3+ TX1TX2+ RX4TX1+ RX3RX4+ Twisted pair RX1RX2+ RX2RX3+ RX1+ Wire Color Wire Type Label
37
Reference
FE cable Pin on the RJ45 Connector X1.2 X1.1 X1.6 X1.3 X1.4 X1.5 X1.8 X1.7 Wire Color Wire Type Pin on the RJ45 Connector X2.2 X2.1 Twisted pair X2.6 X2.3 Twisted pair X2.4 X2.5 Twisted pair X2.8 X2.7
Twisted pair
Monitoring signal cable between the APMI and the BBU Pin on the RJ45 Connector Wire Color Pins on the X2, X3, X4, and X5 X2 Twisted pair X1.2 Orange X3 Twisted pair X1.4 Blue X4 Twisted pair X1.5 White X5 Twisted pair 38 RXRX+ TXWire Type Port on the APMI
X1.1
White
TX+
Reference d
Pin Assignment of the BBU Signal Cables
EMUA monitoring signal cable Pin on the RJ45 Connector Pin on the DB9 Male Connector X2.3 Wire Color Wire Type Port on the APMI
X1.1
White
Twisted pair
TX+
X1.2
X2.7
Orange
Twisted pair
TX-
X1.4
X2.2
Blue
Twisted pair
RX+
X1.5 Alarm cable Pin on the RJ45 Connector X1.1 X1.2 X1.3 X1.6 X1.5 X1.4 X1.7 X1.8
X2.6
White
Twisted pair
RX-
Pin on the RJ45 Connector X2.1 X2.2 X2.3 X2.6 X2.5 X2.4 X2.7 X2.8
Wire Color
Wire Type
Twisted pair
Twisted pair
Twisted pair
Twisted pair
39