Вы находитесь на странице: 1из 4

TECHNICAL SPECIFICATIONS

DS3BA Series High Efficiency Air Conditioner


10 SEER 1-1/2 5 Ton Capacity
The DS3BA Series of air conditioners offers exceptional performance from a small, compact package. The unit, when combined with our engineered coils or air handlers, offers a full line of quality, split system cooling equipment. Units are ideally sized for slab or rooftop mounting in single, multifamily, and light commercial applications.

FEATURES and BENEFITS


Designed using galvanized steel with a polyester urethane finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units. Copper Tube / Aluminum Fin Coils Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. Permanently Lubricated Motor A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow. Full Service Valves These brass valves are easily accessible and simplify servicing of the refrigeration system. Steel GuardTM Protects the unit coil from being damaged by balls, lawnmowers, hail, etc. Removable Top Grille Assembly Allows ease of service from the top without disconnecting fan motor leads.

One Piece Top/Orifice Designed for maximum airflow and quiet operation. 2-1/2" Pedestal Base The sturdy base keeps the bottom of the coil out of harms way. Secondly, the base has weep holes along the edge to allow the water from rain to flow away from the unit. Easy Compressor and Control Access Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. 6 Year Limited Parts Warranty The best in the industry and has proven to be a major benefit to the consumer.

MODEL IDENTIFICATION CODES


EX: DS3BA-036K

D
D - Deluxe S - Air Conditioner T - Heat Pump Generation 1, 2, 3. etc.

036
Nominal Capacity (000) BTU

A
Style A, B, etc.

Product Identifier

BA = Braze 10 SEER BC = Braze 12 SEER BD = Braze 13 SEER

Electrical Code C = 208/230-60-3 K = 208/230-60-1

DIMENSIONS OUTDOOR SECTION


DS3BAH W D 18KA 22-1/2 22-1/2 22-1/2 024KA 22-1/2 22-1/2 22-1/2 030KA 22-1/2 22-1/2 22-1/2 036KA 22-1/2 22-1/2 22-1/2 042KA 30-1/2 22-1/2 22-1/2 048KA 34-1/2 22-1/2 22-1/2 060KB 30-1/2 30-1/2 30-1/2

Air Discharge Allow Adequate Clearance for Airflow

D W

PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS


10 SEER High Efficiency Single Phase
Model No. DS3BAElectrical Data Volts-Cycles-Phase (1) Total Amps Max. Overcurrent (2) Min. Circuit Ampacity Component Data Fan Motor Fan Blade Compressor Data* Refrigerant Suction Line-Length/O.D. (Liq. Line All Lengths - 3/8"O.D.) Refrigerant Charge R-22 Ounces Weight Approximate (lbs.) Coil Area Rows-FPI Tube Dia. Type Amps HP Dia.-#Blades SCFM RLA LRA 15-24 ft. 25-39 ft. 40-75 ft. (Outdoor unit, Indoor Unit 15' Line Set) Net Ship

018KA
208/230-60-1

024KA
208/230-60-1

030KA
208/230-60-1

036KA
208/230-60-1

042KA
208/230-60-1

048KA
208/230-60-1

060KB
208/230-60-1

9.2 15 11.4 8.3 1-14 3/8 O.D. PSC 0.67 1/10 18 in. - 3 2100 8.6 49 5/8" (3) 5/8" (3) 3/4" 63 116 122

10.5 20 12.9 8.3 1-14 3/8 O.D. PSC 0.67 1/10 18 in. - 3 2100 9.8 56 5/8" (3) 3/4" 3/4" 64 118 124

14.8 30 18.2 8.3 1-18 3/8 O.D. PSC 1.13 1/8 18 in. - 3 2500 13.7 75 3/4" 3/4" 3/4" 68 124 130

15.9 30 19.7 8.3 1-22 3/8 O.D. PSC 1.13 1/8 18 in. - 3 2500 14.8 96 3/4" 3/4" 7/8" (4) 69 128 134

18.1 35 22.4 11.5 1-20 3/8 O.D. PSC 1.13 1/8 18 in. - 3 2500 17.0 105 3/4" 7/8" (4) 7/8" (4) 87 133 140

23.2 50 28.6 13.2 1-18 3/8 O.D. PSC 1.4 1/4 18 in. - 4 3000 21.8 131 7/8" 7/8" 7/8" 102 162 174

28.5 60 35.3 17.7 1-22 3/8 O.D. PSC 1.5 1/4 24 in. - 3 4000 27.0 144 7/8" 1-1/8" (5) 1-1/8" (5) 114 190 202

10 SEER High Efficiency Three Phase


Model No. DS3BAElectrical Data Volts-Cycles-Phase (1) Total Amps Max. Overcurrent (2) Min. Circuit Ampacity Component Data Fan Motor Fan Blade Compressor Data* Refrigerant Suction Line-Length/O.D. (Liq. Line All Lengths - 3/8"O.D.) Refrigerant Charge R-22 Ounces Weight Approximate (lbs.) Coil Area Rows-FPI Tube Dia. Type Amps HP Dia.-#Blades SCFM RLA LRA 15-24 ft. 25-39 ft. 40-75 ft. (Outdoor unit, Indoor Unit 15' Line Set) Net Ship

036CA
208/230-60-3

048CA
208/230-60-3

060CB
208/230-60-3

11.3 20 13.9 8.3 1-22 3/8 O.D. PSC 1.13 1/8 18 in. - 3 2500 10.2 75 3/4" 3/4" 7/8" (4) 69 128 134

14.2 30 17.4 13.2 1-18 3/8 O.D. PSC 1.4 1/4 18 in. -4 3000 12.8 91 7/8" 7/8" 7/8" 115 162 174

20.1 40 24.7 17.7 1-22 3/8 O.D. PSC 1.5 1/4 24 in. - 3 4000 18.6 128 7/8" 1-1/8" (5) 1-1/8" (5) 114 190 202

COPPER WIRE SIZE AWG (1% Voltage Drop) Supply Wire Length-Feet Supply Circuit 200 150 100 50 Ampacity

6 4 4 4 3 3 2 2

8 6 6 4 4 4 3 3

10 8 8 6 6 6 4 4

14 12 10 10 8 8 6 6

15 20 25 30 35 40 45 50

Wire Size based on N.E.C. for 60 type copper conductors.

* Values shown are most severe and may vary slightly depending on the make of the compressor supplied. (1) Operating Voltage Range: 198v min. 253v max. (2) HACR Type Circuit Breakers or Time Delay Fuse (3) Requires 3/4" to 5/8" reducer from unit to line. (4) Requires 7/8" to 3/4" reducer from line to unit. (5) Requires 7/8" to 1-1/8" reducer from line to unit.

SYSTEM HEATING & COOLING CAPACITIES


10 SEER High Efficiency Single Phase
Outdoor Unit Model Number DS3BA018KA 024KA 030KA 030KA 036(C,K)A 036(C,K)A 042KA 048(C,K)A 048(C,K)A 060(C,K)B Coil C3BA024C/U-A (2) 024C/U-A (2) 030C/U-B 036C/U-A (2) 036C/U-B (2) 036C/U-A (2) 042C/U-B 048C/U-B (2) 048C/U-C 060C/U-C (2) With This Coil Cooling Btuh 18,000 22,800 28,600 29,000 34,600 34,000 40,000 46,000 46,000 58,000 SEER 10 10 10 10 10 10 10 10 10 10 Nominal CFM 675 900 1125 1125 1350 1150 1500 1500 1500 1800 Required Orifice Size .051 (1) .060 .063 .063 (1) .067 .067 .075 .080 .080 .093

Outdoor Unit Model Number DS3BA018KA 024KA 030KA 030KA 036(C,K)A 042KA 048(C,K)A 060(C,K)B Air Handler B3B(M,V)024K-A 024K-A 030K-A 030K-B 036K-B 042K-B 048K-B 060K-C

With This Air Handler Cooling Btuh 18,000 23,000 28,600 28,600 34,600 40,000 46,000 57,000 SEER 10 10 10 10 10 10 10 10 Nominal CFM 675 900 1125 1125 1350 1500 1600 1700 Required Orifice Size .051 (1) .060 .063 .063 .067 .075 .080 .093

(1) Supplied with indoor section. (2) Also available as C3BH Horizontal Case Coil. See current ARI Directory for certified combinations and ratings.

ACCESSORIES - Condensing Unit


Start Assist Kit - 912933 Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures. Thermostat Two thermostats are available. 917004 - Single-Stage 917005 - Two-Stage Heat / One-Stage Cool

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI

325A-0803 (Replaces 325A-0203)


Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (08/03)

O'Fallon, MO

Вам также может понравиться