Instant CT
Quick:
:40
Instant CT
Fits Your Workflow
MiniCAT adult scans take 40 seconds, pediatric scans take only 20 seconds
Optimized:
MiniCAT is the right tool for the right task
MiniCAT is specifically designed to scan the sinuses and temporal bones, unlike multi-purpose full-body CT scanners
High Definition (HighDef) spatial resolution with 300 scan slices as thin as 0.2mm Customized Field of View optimized for scanning of the sinuses, temporal bones, and skull base
Safe:
Offer your patients peace of mind with low radiation
MiniCAT adult scans have about one tenth the radiation dose than sinus scans on a full-body CT scanner
MiniCAT pediatric scans have half the radiation dose than MiniCAT adult scans.
Xoran designed MiniCAT according to the ALARA principle (As Low As Reasonably Achievable)
Xorans innovative technology optimizes x-ray efficiency, minimizing the radiation dose to the patient while providing unprecedented, high resolution images of the sinuses, and temporal bones.
Convenient:
Everything you need for a diagnosis in one place at one time For the patient:
No need for several appointments between your doctors office and a hospital or imaging center Get your diagnosis during your office exam so you can begin your treatment and start feeling better faster Same day diagnosis minimizes your insurance co-pays With MiniCAT , you sit comfortably upright in an open, patient-friendly design, unlike full-body scanners at hospitals that can be claustrophobic
An intuitive system allows you to conveniently mark your studies and easily export them to multiple formats, including portable media (like a CD or a USB flash drive) or print them on the supplied ink jet printer On site CT eliminates wasted time and resources tracking down hospital CT films and ensures patient compliance MiniCAT is compatible with major navigation devices: You can easily load your pre-operative scans onto your navigation device with a CD
Ensure the security of your patient data with XoranVault, secure off-site digital storage of MiniCAT images and free data recovery as needed
Adult scans take 40 seconds, and childrens scans take only 20 seconds Lower radiation dose gives you peace of mind
Access your MiniCAT studies at any time with XoranView, online viewing capability for 3 concurrent users
Xorans dedication to extraordinary customer service means quick remote software fixes, expert telephone support, and same or next day service calls when needed
Instant CT
In Your Office
Simple:
All good things should be this easy
With dogged attention to customers needs and service, Xoran delivers a turn-key solution for your MiniCAT point-of-care CT scanning service:
With its small (3.5) footprint, MiniCAT fits in an 8 x 10 room and plugs into a standard 110V wall outlet
Xoran installs the MiniCAT in one day and provides you with on-site training the next day
Technical Specifications:
General Information System Dimensions Minimum Room Size Weight Internet Connectivity IGS Compatibility 49 x 49 x 72 (117 x 119 x 183 cm) 6 x 9 450 lbs. High speed connection required for maintenance Compatible with IGS platforms GE, Medtronic, BrainLAB, Stryker Electrical Power Requirements Line Voltage* Line Frequency Line Current Main Circuit Breaker JAPAN ~100 V 5060 Hz 5 A Standby 10 A Max EUROPA ~220240 V 5060 Hz 2.5 A Standby 5 A Max USA ~115 V 5060 Hz 5 A Standby 10 A Max
Standard Imaging Protocols Adult Sinus Pediatric Sinus Follow-up Sinus Temporal Bone
mA 5 5 5 7
Effective Dose to Patient 0.13 mSv 0.07 mSv 0.04 mSv 0.14 mSv
Imaging Properties Scan Time Detector Data Channels Detector Element Size Slice Thickness 40 seconds 758 254 m x 254 m 0.2 mm minimum ~60 sec for 200 slices 12 cm max 16.5 cm max MPR / Axial / Coronal / Sagittal / Panoramic cross-section / Raw data cine 256 levels Adjustable level and width 360 Intel-based PC DICOM 3.0
44 39 72 46
*Voltage must be held within 10% of the specified Line Voltage Environmental Conditions Operating Requirements 50 to 95 Fahrenheit (10 to 40 Celsius) 45% to 75% humidity 32 to 104 Fahrenheit (10 to 40 Celsius) 45% to 75% humidity Approx. 500W / 1700 BTU/hr
Patient Support Chair Overall Dimensions Weight Seat Height Adjustment Maximum Patient Weight 30.5d x 29w x 50.5h (77.5 x 73.7 x 128.3 cm) 115 lbs. (52 kg) 12.5 to 21.5 (31.8 to 54.6cm) 350 lbs. (159 kg)
It is recommended that MiniCAT is operated in a climate-controlled clinical or hospital environment. Changes in temperature may cause the system to require additional calibration.
Gray Scale Display Display Window Gantry Rotation Angle Workstation Compatibility
309 N. First Street Ann Arbor, MI 48103 (800) 70-XORAN email: info@xorantech.com web: www.xorantech.com