Вы находитесь на странице: 1из 5

SPECIFICATIONS Electrocadiograph 12 Channel Merk Country of Origin Type

: Mediana : Korea : YM412i

Features: 12 lead interpretative ECG Grapich LCD monitor ECG storage (typical : 100 ECGs, option : 5000 ECGs) Built-in high resolution printer Rechargeable battery Firmware upgrade using USB memory stick Measurement and average complexes; The ECG'S measuing program determines precisely the beginning and end points of P waves, QRS complexes and T waves based on noise reduced average complexes, Electrical axis as well as exact time and amplitude measurement are provider ECG'S Interpretation; the ECG's has the clinically proven interpretation program of diagnostic information with regard to rhythm, electrical axis, QRS morthopology changes, conduction defects, hyfertrophy characteristic, ST-T change, myocardial infarction with an interpretation time of less than 6 seconds. Communication with PC; via the serial interface, the electrocardiograph can be directly connected to PC, saving and transmitting of measured data, efficient patient information management. Technical Data : Display Type Resilution Computerized Electrocardiograph ECG storage Pre-Acquisition Dynamic Range Sampling rate Frequency Response Common Mode Injection Input Impedance Patient Leakage Current Communication Firmware Upgrade Filter

: 103 mm (W) x 77.22 mm (H), STN mono LCD : 320 x 240 dots : Basic - 100 ECG's (typical) Option - 5000 ECG's in SD Card ( 1GB) : Provides 10s of instantaneous ECG acquistion : AC diferential : 5mV DC offset : 300mV : 500 Hz : 0.05 to 150 Hz : 100 dB : >50 M : <10 A : PC communication with RS232 interface and LAN : Use the USB memory stick : AC : 50/60 Hz Low Pass Filter : 40, 100, 150 Hz

SPECIFICATIONS Base line Filter : 0.5 Hz, Muscle Filter Writer Type Speeds Number Of Traces Sensitivity/Gain Speed Accuracy & Amplitude Accuracy Paper Type/Size Electrical Power Supply AC Input Fuses Battery Type Battery Capacity Battery Charge Time Physical Dimension Weight Environmental Operating Conditions

: : : : : : : : : :

Thermal dot array 5, 10, 25, 50 mm/sec 3, 6 or 12 user-selectable 5, 10, 20 mm/mV 5% Thermal Roll, 110 mm (W) x 30 mm (L)

AC or Battery Operation 100 - 240 VAC, 50/60 Hz, 70 VA qty. 2, 250 Vac T6.3AL, IEC (5 X 20 mm) 12V 3.8Ah, Rechargeable Nickel Metal Hydride Cylindical Cell : 150 basic report (Auto Mode) or 5 Hours continuous operation (without Printing) : Approximatelly 6 hours from total discharge : 351 x 268.5 x 63 (W x L x H) mm : 2.7 Kg (including battery) without paper : Temperature range 10 - 45C Humidity range 20%-95% (not condensing) Atmosphere Pressure : 700 to 1060 hPa : Temperature range -20~60C Humidity Range 10%~95% (non condensing) Atmosphere Pressure : 500 to 1060 hPa : Certified for IEC60601-1 CE marking for Council Directive 93/42/EEC concerning Medical Devices Meets applicable IEC60601-2-25 requirements : Class 1, Internally Powered : IPX 0 : Continuous : <10A : Type CF with defibrillation protection : Daily visual inspection and routine cleaning (if needed) performed by user. Use a commercially availabe, industrial strength disinfection cleaner on any part of the equipment (other than electrodes) which comes into direct contact with the patient.

Storage/Transportation Conditions

Safety Certification

Type of Protection Againts Electrical Shock Dust and Water Resistance Patient Mode of Operation Patient Leakage Current Degree of Protection Againts Electical Shock Maintenance

SPECIFICATIONS Standar Accessories 1. Electrode clamp 2. Cup Electrode 3. ECG cable 4. Ground Cable 5. Power Cord 6. Paper ECG 7. RS232 cable

SPECIFICATIONS Electrocadiograph 12 Channel Merk Country of Origin Type

: Mediana : Korea : YM412i

Features: 12 lead interpretative ECG Grapich LCD monitor ECG storage (typical : 100 ECGs, option : 5000 ECGs) Built-in high resolution printer Rechargeable battery Software management (PC interface : RS232, LAN (reservel)) Firmware upgrade using USB memory stick Specifications : Display Type Resilution Computerized Electrocardiograph ECG storage Pre-Acquisition Dynamic Range Sampling rate Frequency Response Common Mode Injection Input Impedance Patient Leakage Current Communication Firmware Upgrade Filter

: 103 mm (W) x 77.22 mm (H), STN mono LCD : 320 x 240 dots : Basic - 100 ECG's (typical) Option - 5000 ECG's in SD Card ( 1GB) : Provides 10s of instantaneous ECG acquistion : AC diferential : 5mV DC offset : 300mV : 500 Hz : 0.05 to 150 Hz : 100 dB : >50 M : <10 A : PC communication with RS232 interface and LAN : Use the USB memory stick : AC : 50/60 Hz Low Pass Filter : 40, 100, 150 Hz Base line Filter : 0.5 Hz Muscle Filter : : : : : : : Thermal dot array 5, 10, 25, 50 mm/sec 3, 6 or 12 user-selectable 5, 10, 20 mm/mV 5% 5% Thermal Roll, 110 mm (W) x 30 mm (L)

Writer Type Speeds Number Of Traces Sensitivity/Gain Speed Accuracy Amplitude Accuracy Paper Type/Size Electrical Power Supply

: AC or Battery Operation

SPECIFICATIONS AC Input Fuses Battery Type Battery Capacity Battery Charge Time Physical Dimension Weight Environmental Operating Conditions : 100 - 240 VAC, 50/60 Hz, 70 VA : qty. 2, 250 Vac T6.3AL, IEC (5 X 20 mm) : 12V 3.8Ah, Rechargeable Nickel Metal Hydride Cylindical Cell : 150 basic report (Auto Mode) or 5 Hours continuous operation (without Printing) : Approximatelly 6 hours from total discharge : 351 x 268.5 x 63 (W x L x H) mm : 2.7 Kg (including battery) without paper : Temperature range 10 - 45C Humidity range 20%-95% (not condensing) Atmosphere Pressure : 700 to 1060 hPa : Temperature range -20~60C Humidity Range 10%~95% (non condensing) Atmosphere Pressure : 500 to 1060 hPa : Certified for IEC60601-1 CE marking for Council Directive 93/42/EEC concerning Medical Devices Meets applicable IEC60601-2-25 requirements : Class 1, Internally Powered : IPX 0 : Continuous : <10A : Type CF with defibrillation protection : Daily visual inspection and routine cleaning (if needed) performed by user. Use a commercially availabe, industrial strength disinfection cleaner on any part of the equipment (other than electrodes) which comes into direct contact with the patient. Every six months routine maintenance checks and test performances are recommended

Storage/Transportation Conditions

Safety Certification

Type of Protection Againts Electrical Shock Dust and Water Resistance Patient Mode of Operation Patient Leakage Current Degree of Protection Againts Electical Shock Maintenance

Accessories 1. Electrode clamp 2. Cup Electrode 3. ECG cable 4. Ground Cable 5. Power Cord 6. Paper ECG 7. RS232 cable