Tips on Wiring system of motor room Edited by FiberCasa The Wiring system of motor room directly affects the

function of the future room, general wiring system requires protection distance as short and neat, orderly arrangement, "Tian" and "well" two specific ways. Among them: "Tian" font is suitable for circular room layout, "well" shape is more suitable for vertical and horizontal type room layout. Its location can be arranged in the floor and ceiling of two places, each have a characteristic, are discussed below: 1, floor wiring: This is one of the most common wiring way, it makes full use of the space below the floor, but should pay attention to water leakage, rodents and radiating floor, shall also ensure that in each cabinet cut under the threading hole corresponding (including the floor and slot). 2, the ceiling wiring: the wiring method is particularly suitable for often need wiring room, is also very popular, this way the ceiling contains various wiring power, cabling, in each cabinet above the cut line through hole corresponding (including the floor and trough), of course, also want to pay attention to water leakage, rodents and heat dissipation. Specific content: the power supply wiring wiring, cabling and ground wire, wherein the power supply wiring and cabling are placed in metal wiring groove, the metal wiring groove size according to how much weight and consider the development of space (generally 100 * 50 or 50 * 50). Between the power line channel and the weak line grooves must keep a distance of at least 5 centimeters of above, between each other can't get through, in order to prevent the mutual electromagnetic interference. The following one one elaborate: A, power supply wiring: power supply wiring in room decoration, should be based on the whole room layout and the capacity of UPS to arrange, in the planning of each cabinet and equipment near the power socket, arrange corresponding, socket capacity should be based on the power to set the access equipment, and some redundancy, generally 10A or 15A. Power supply wire diameter should be based on the power supply socket capacity and have a capacity to purchase. B, weak electricity wiring: cabling consists of coaxial thinnet, category five cable and telephone cables, wiring should pay attention to have the corresponding cable behind each cabinet, equipment, and should consider the future development needs, all kinds of cable should be arranged using nylon woven strapping. C, the ground wiring: due to the new room are of high performance computer and network communication equipment, so the earth has strict requirements, grounding and the elimination of common impedance, preventing capacitive coupling interference, equipment and personnel to protect the security of computer system, an important measure to ensure the stable and reliable operation. In the engine room floor with ground signal layout of copper, for room within the various grounding, weak signal bar to access the line grounding system. On 6 types of cable wiring

1, if there is excess cable in 2 terminal, which will have to be cut to length, and should not be rolled up and tied up. Joint of 2, cable - winding open line distance should not exceed 2cm, too long will cause the near end crosstalk larger. 3, at the joint, the outer protective layer of cable required pressure within the joint and not in the joint. Although online cable by external force when the whole will force, but if the outer protective lamination in joint force, it will be mainly metal connecting cable and connector part. 4, the construction of cable wiring, cable tension is limited, generally about 9kg. Excessive tension will damage the cable twisted pair symmetry. 5, because six kind of cable outer diameter than five line usually thick, in order to avoid cable winding (especially in the elbow) in pipeline design, attention must be paid to the filling degree diameter, inner diameter 20mm line pipe in order to put 2 six lines is appropriate. On the pre buried pipeline 1, even in various cable pipe pre buried in the future may not be able to guarantee does not need to be changed, can be handled in this way. In the corner part (mounted skirting tile position), cut a groove, skirting bonding brick wall mounted with 2/3. Each cell of some distance, skirting tiles installed an activity, method of installation skirting tiles is pre buried wood in the wall. Activity skirting tiles may according to need to drill hole fixed, with wood screws fixed copper or stainless steel. So make a pipe in the wall (the lowest part of pipeline over the final plane 2-5cm). Future if the need to replace the ELV cable only need to remove activities skirting tiles. Across the ground buried pipe are the best plane 2-4cm final and beyond. Stay extra floor consideration on flood control, drainage. 2, through the center of the room embedded pipe. Two treatment than plane 2-5cm final. The real main draw good line, after the completion of construction to retain good (for several years after the maintenance basis). 3, through the pipe construction cause layer damage to replace insulated cable, not on. General renovation contract should specify threading requirements, cable insulation layer damage responsibility to distinguish. Fiber Cable beforehand, and concentrated to a suitable location (usually outdoor cable home office), according to the actual demand, flexible combination, use, support phone / fax, Internet, cable TV, home theater, music, video on demand, fire alarm, security alarm, automatic control, lighting control, gas leakage alarm, water / electricity / gas automatic meter copy and other applications.

Вам также может понравиться