Installation manual
07/2008 eng
35004729.04
www.schneider-electric.com
Document Set
Document Set
Document set Further details on installing the different tools (converters, communication drivers, etc.) are given on the documentation CD-ROM supplied with the software.
35004729.04 07/2008
Document Set
35004729.04 07/2008
Table of Contents
Chapter 2
Hardware implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
35004729.04 07/2008
35004729.04 07/2008
At a Glance
Document Scope Validity Note User Comments This manual is used to install the basic PL7 software. This document takes into account the changes implemented in PL7 V4.5. We welcome your comments about this document. You can reach us by e-mail at techpub@schneider-electric.com
35004729.04 07/2008
35004729.04 07/2008
Software implementation
1
Introduction
Aim of this chapter. What is in this Chapter? This chapter introduces implementation of PL7 operations.
35004729.04 07/2008
Software implementation
Terminal configuration
Definition The configuration type determines the level of expected performance. Performance of PL7 software can be affected by simultaneously opening several windows, accessing large quantities of animated data, or using a large application. PL7 V4.5 software requires one of the following operating systems to be present on the terminal:
z z
Note: Certain functions are unavailable using the Windows VISTA Professional Edition 32 system. For more details, refer to the relevant chapters.
Minimum configuration
The following table provides the minimum terminal characteristics necessary to implement PL7 software, once Windows is installed on the terminal:
Elements System RAM Drives Characteristics Windows XP: Pentium 266 MHz processor Windows VISTA: 1 GHz 32-bit processor Windows XP: 128 Mb Windows VISTA: 512 Mb Hard disk CD-ROM Ports Peripheral Monitor
z COM serial port available for connection to the PLC (COM 1 to COM 4) z Parallel port for printer (LPT1 to LPT4) z 80 Mb for the software z 25 Mb for temporary directories
10
35004729.04 07/2008
Software implementation
Typical configuration
The following table shows a configuration for attaining optimal PL7 software performance, once Windows is installed on the terminal:
Elements Systems RAM Drives Characteristics Windows XP: Pentium 500 MHz processor Windows VISTA: 1 GHz 32-bit processor Windows XP: 128 Mb Windows VISTA: 1GB Hard disk
z 80 Mb for the software z 25 Mb for temporary directories
A mouse or pointer compatible with Windows technology 800*600 or SVGA with 24 bit color management recommended)
Please note:
A more important configuration may be required if other software is used simultaneously with PL7.
35004729.04 07/2008
11
Software implementation
12
35004729.04 07/2008
Software implementation
This procedure describes the different steps for installing PL7 software.
Insert CD-ROM
Enter the product installation code (*) then confirm with Ok (a maximum of 3 entry attempts are allowed)
common to all installations
Customized
Standard
Select the components that you wish to install then confirm with Next
(*) The installation code is located on the adhesive label on the back of the PL7 programming software CD-ROM.
35004729.04 07/2008
13
Software implementation
14
35004729.04 07/2008
Software implementation
Procedure
Yes
Select a registration method: By telephone, by fax, by e-mail or via the Web then confirm with Next Telephone, Fax, E-mail Enter the required fields, the serial number and the commercial reference (*) and confirm with Next Telephone Telephone Schneider Electric to obtain the activation code, then click OK Fax Web Enter the required fields, the serial number and the commercial reference marked on the installation CD-ROM box, and confirm with Register E-mail
Enter the fax number to Enter the e-mail address which the response is to to which the response is be sent and confirm with to be sent, and confirm Next. with Next. A fax containing your An e-mail containing your data is generated in text data is sent automatically format: Send this fax to the specified address.
Wait for the response from Schneider Electric and restart PL7 or the Registration tool
(*) These numbers are marked on the label inside the box containing the software CD-ROMs.
35004729.04 07/2008
15
Software implementation
16
35004729.04 07/2008
Software implementation
This procedure describes the different steps for installing PL7 software.
Insert CD-ROM
Open the Setup.exe file Confirm at the welcome screen with Next Choose the software language then confirm with Next Enter the product installation code (1) then confirm with Ok (a maximum of 3 entry attempts are allowed) Yes Insert CD ROM or the first disk of the previous version (2) then confirm with Next
No
Yes
(1) The installation code is located on the adhesive label on the back of the PL7 programming software CD-ROM.
(2): First installation software package
35004729.04 07/2008
17
Software implementation
How to configure the Uni-telway driver with a modem in Windows XP and Windows VISTA
Introduction This procedure can configure the Uni-telway connection driver as a function of the characteristics of the final PLC takeover. Note: For more information on the configuration dialog boxes of the Uni-telway driver, consult the Drivers manual available on the CD-ROM documentation provided with the PL7 software.
18
35004729.04 07/2008
Software implementation
The following table describes the procedure to configure the Uni-telway driver.
Step 1 2 3 4 5 Action Carry out the command Start up Program. Select the Modicon Telemecanique group. Select XWAY Driver Manager. Click on the Uni-telway tab. Click on the Configuration button. Results: The dialog box below appears:
UNITELWAY Configuration Station List Target Station: Station ID [Default] Port COM 1 [Default] Password Ph
Add
Modify
Suppress
OK
Cancel
Apply
35004729.04 07/2008
19
Software implementation
Step 6
Station ID [Default] COM Port COM 1 UNI-TELWAY Slave Address Base 1 Numbers 3
OK
Cancel
7 8
From the Uni-telway tab, configure the communication port (COM Port) field. Click on Ok
20
35004729.04 07/2008
Software implementation
OS_LOADER PL7 Pro V4.5 PL7 Pro V4.5 Readme PL7 Pro V4.5 XWAY Driver Manager
SET
35004729.04 07/2008
21
Software implementation
application files, Elements shared by other software (PL7 sys.ini, Config.sys, PL7user, PL7temp,).
Uninstallation only deletes selected software. Carry out the following operations for each package to be deleted.
Step 1 2 3 4 5 6 7 Action Execute the command Start Parameters Configuration panel Add/ Delete Programs.ConCCcc Select the Install/uninstall tab. Select PL7V4.. Select Add/Delete. Select the elements to be uninstalled (kernel and/or common components), Select OK and confirm with Yes, Confirm the information screen with OK.
22
35004729.04 07/2008
Software implementation
Note: Once the access rights have been transferred, the source terminal can no longer use PL7 unless you save again or make a reverse transfer. Following transfer of the rights to floppy or removable disk, if these rights are altered before being transferred to the destination terminal, contact Schneider Electric for a new registration.
35004729.04 07/2008
23
Software implementation
This procedure describes the different steps for transferring user rights.
Start the Registration Tool
Select the transfer method: Network, disk, (3 1/2" or removable disk with USB port) and confirm with Next (for a disk transfer, insert a blank disk) Using a removable disk Insert the removable disk into the USB port Choose drive (A: or the letter associated with the removable disk) Using a disk Using a network Enter the name of the target terminal and share the PL7 directory on this terminal (with read rights), then confirm with OK
On the target terminal, note the PC identifier On the current terminal, enter the same identifier and confirm with OK Using a disk On the target terminal, insert the disk containing the rights, and select Transfer authorization to the terminal from disk Using a network
On the target and current terminals, quit the procedures by clicking Finish
24
35004729.04 07/2008
Hardware implementation
2
Connections
Introduction This module deals with the connection of the terminal to the PLC via a cable. A description of how to make other specific connections to the terminal (monitor, keyboard, mouse, printer, mains) is provided in the manufacturer documentation. Other modes of connections are possible, such as connections via UNITELWAY bus or Modem (via the telephone network). PC - PLC connection To connect a PC, you will require the 2.5 m TSX PCX 1031 or TSX CUSB 485 and TSX CRJ MD25 cables, supplied with new software packages (not supplied with update or upgrade variants).
Mains
Mains
Mains TSX PCX 1031 / TSX C USB 485 / TSX CRJ MD25
Note: The TSX PCX 1031 cable requires the use of the UNITELWAY driver of at least version: z V1.5 (for Windows XP Professionnel) z V2.0 (for Windows VISTA Professionnel Edition 32).
35004729.04 07/2008
25
Hardware implementation
26
35004729.04 07/2008