(NOTE: These instructions are not intended for Hondas i models. Call GenTran for wiring instructions on Hondas i models.)
GREEN
BLACK
YELLOW
To connect the Honda Remote Start cable to the GenTran PowerStay ATS Low Voltage Cable, cut the Honda-furnished cable to a convenient length, and strip off approx. 3 of outer jacket, and strip the four conductors inside. Then connect with wire connectors to the GenTran PowerStay ATS cable per the diagram below.
} {
ON/OFF CRANK BATT BATT + Green Terminal Block on GenTran PowerStay ATS PC board
Ignition Switch on Generator: Leave OFF for EM 3500, EM5000, EX4500 and EX5500 Turn to ON for EM6000GPA propane unit
NOTE: Jumpers on GenTran PowerStay ATS system PC board should already be set to "Pull-Up" position (see page 16 of Installation Manual). No need to change jumper position.
NOTE: Jumpers on GenTran PowerStay ATS system PC board should already be set to "Pull-Up" position (see page 16 of Installation Manual). No need to change jumper position.
*External Relay REQUIRED. Kohlers remote start/stop circuit is a dry circuit that has blocking diodes. Normally, the GenTran PowerStay Automatic Transfer System (ATS) uses one of the two wires in this circuit to read the condition of the battery as well as to charge the battery. However, the blocking diodes prevent this system from working. Therefore, an external relay (Type SPNO w/ 12VDC coil) must be installed in the controller box to close and open this dry circuit. A suggested external relay and socket is available through Grainger Part numbers # 5Z486 (relay) and # 6JG21 (socket) at an approximate cost of $17. Onboard Battery Charger on Generator is NOT USED. Kohler provides a battery charger on the generator, and a separate 120 volt wire is supplied in the package. However, the GenTran PowerStay Automatic Transfer System has a built-in battery monitor and charger, this onboard charger included with the Kohler kit is not used.
NOTE: Winco engineers suggest that the 3/4 amp fuse in the Battery + line in the generator be changed to a 3 or 4 or 5 amp type AGC fuse so that the integrated charger in our ATS system will not blow the fuse. The 120-volt wire intended to be run from the house to the generator for the Winco charger does NOT need to be used since our integrated charger will charge the generator battery.