Вы находитесь на странице: 1из 2

OIL-FREE

AIR COMPRESSORS

Motor HP

ROTARY SCREW

H-SERIES WATER-COOLED* TWO-STAGE


Max. Pressure PSIG Free Air** Delivery CFM

60 HZ
Height In. Net Weight Lbs.

Dimensions and Specifications


Model

Typical, do not use for construction. (Drawings are provided with order acknowledgement.)
Length In. Width In.

KNW00-A/H KNW00-B/H KNW00-C/H KNW00-D/H KNW0-A/H KNW0-B/H KNW0-C/H KNW0-D/H KNW0-E/H KNW1-A/H KNW1-B/H KNW1-C/H KNW1-D/H KNW1-E/H KNW1-F/H KNW1-G/H KNW2-A/H KNW2-B/H KNW2-C/H KNW2-D/H KNW3-A/H KNW3-B/H KNW3-C/H

25 30 40 50 50 60 75 100 100 100 125 125 150 150 200 200 200 250 300 350 400 450 500

125 125 125 125 150 150 150 135 135 150 150 150 150 150 135 135 150 150 150 150 135 135 135

72 91 122 162 172 223 292 331 400 413 504 534 618 653 728 812 908 1096 1310 1552 1765 1936 2155

85 85 85 85 70 70 70 70 70 100 100 100 100 100 100 100 124 124 124 124 139 139 139

36 36 36 36 49 49 49 49 49 63 63 63 63 63 63 63 75 75 75 75 82 82 82

61 61 61 61 54 54 54 54 54 60 60 60 60 60 60 60 72 72 72 72 92 92 92

2190 2320 2410 2540 3050 3200 3250 3330 3330 5180 5370 5390 5720 5740 5960 6040 9420 9670 10350 10930 12970 13260 13640

*For air-cooled requirements, refer to Bulletin KNWA/L & KNWA/H

Compressor Air In

Compressor Air Out

Automatic Drains

KNW/H (0412)
Printed in U.S.A.

Standard Equipment and Safety Devices


Controls and Instrumentation
Service Indicators n Air inlet filter condition indicator n Oil filter condition indicator n Oil level gauge n Routine maintenance Pressure Indicators n First stage air discharge pressure n Second stage air discharge pressure n Oil pressure Temperature Indicators n First stage air discharge n Second stage air inlet n Second stage air discharge n Lube oil n Compressor discharge temperature Additional Indicators n Stand-by mode light n Oil pump run light n Fan run light n Compressor run light n Compressor laod light n Alarm light n Hour meter running time n Hour meter loaded time n Manual unload light and switch n Pre alarms

Safety Devices
All safety shutdowns, indicated by message on display and alarm light
n

n n

Compressor motor overload shutdown light Oil pump motor overload shutdown light Fan motor overload shutdown light High first stage air discharge temperature shutdown and light High second stage suction temperature shutdown and light High second stage air discharge temperature shutdown and light High oil temperature shutdown and light Low oil pressure shutdown and light High cabinet temperature shutdown and light

Starter failure light Temperature pre-shutdown alarms Compressor discharge temperature shutdown and alarm

Additional Devices Start/stop push buttons n Lamp test n Audible alarm n Acknowledge switch n Reset switch n Common alarm contacts for remote indication n Event alarm log n Internet options n Color monitor options
n

Additional Features
Packaged Assembly
n n

Advanced Design
n

n n n n n

Air-cooled or water cooled Integral air-cooled or watercooled aftercooler with moisture separator and automatic drain Cabinet ventilating fan Easy access for maintenance Removable doors Low installation cost Few connections required for installation compressed air, condensate drains, electrical and water (when required) Wye Delta motor starter (460 volt standard) CSA certified panel

Super Rotor delivers more cfm per horsepower Patent numbers 4583927 & 4671749

Standard and optional equipment subject to change without notice.

Efficient Control
n n

Load/unload electro-pneumatic Low unload horsepower

Vibration Free
n

n n n

No vibration generated in rotary design No special foundation required Variable frequency drive available Energy saving heat of compression dryer available

DISTRIBUTED BY:
14650 SW 72nd Avenue Portland, Oregon 97224-7943 P.O. Box 230429 Portland, Oregon 97281-0429 Phone (503) 639-0808 Fax (503) 639-0111 E-mail: kobelco@rogers-machinery.com www.knw-series.com