Command to get and adjust Priamry CPICH Power (Default is 320)
================================================================================
=================================
RNRST08> get U08-BKK1536-1A pri.*
RNRST08> set U08-BKK1536-1A primaryCpichPower 300
================================================================================
=================================
Command to get and adjust Individualoffset (reccommeded is 0)
================================================================================
=================================
RNRST08> get U08-BKK2874-1A individualoffset.*
RNRST08> set U08-BKK2874-1A individualOffset 30
RNRST08> set U08-BKK2874-1A individualOffset -30
================================================================================
=================================
Command to get and set e-tilt
================================================================================
=================================
BKK1132-U08> get ret elect
Result will be shown as below
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
SectorAntenna=3,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele
ctricalAntennaTilt 60
SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele
ctricalAntennaTilt 40
SectorAntenna=2,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele
ctricalAntennaTilt 40
================================================================================
=================================
BKK1132-U08> set SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=
1,RetDevice=1 electricalAntennaTilt 60
================================================================================
=================================
Command to get alarm
================================================================================
=================================
mobatch t 500 p 50 RBS.txt lt all;alt;lga
--when u run mobatch
it will read from your txt file
if you put -p 50
it mean it will open every 50 sites in your list
until finish
it means it will run every 50 sites at same time
-t is the expired time

after this amount of time (count by second) if there's no response it will close
anyway, not so important
I always put -t quite high
but -p will effect, for node B & simple command you put p high is ok
but if run mobatch for RNC
& the data u wanna get is huge
better reduce -p
so the server wont be overload
To learn the command you can start with type "h"
----================================================================================
=================================
Command to get & Set Primary CPICH power
================================================================================
=================================
RNRST08> get u08-bkk2874.* primarycpich.*
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK2874-2A
primaryCpichPower 320
UtranCell=U08-BKK2874-2B
primaryCpichPower 320
UtranCell=U08-BKK2874-2C
primaryCpichPower 320
UtranCell=U08-BKK2874-1A
primaryCpichPower 320
UtranCell=U08-BKK2874-1B
primaryCpichPower 320
UtranCell=U08-BKK2874-1C
primaryCpichPower 320
================================================================================
=================================
RNRST08> set u08-bkk2874-2B primarycpichpower 300
================================================================================
=================================
Command to check whether cell is carring traffic.
================================================================================
=================================
BKK1352-U08> get radio
Result
================================================================================
=================================
1422
NodeBFunction=1,Sector=4,Carrier=1,RadioLin
ks=1
================================================================================
=================================
RadioLinksId
1
noOfRadioLinks
20
================================================================================
=================================
++++++ Command to check status of cell and channel ++++++++
================================================================================
=================================
RNRST06> lst u08-bkk1664.* ( this will show adm and op state includding channel
status including EUL channel.)

RNRST06> st u08-bkk1664.* ( this will show only adm and op state )


================================================================================
=================================
++++++ Command to check & Set admission control ++++++++
================================================================================
=================================
RNSNK11> get BKK1132 sf8adm
130222-10:39:44 10.229.70.14 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/16576
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK1132-1A
sf8Adm
8
UtranCell=U08-BKK1132-1A
sf8AdmUl
8
UtranCell=U08-BKK1132-1B
sf8Adm
0
UtranCell=U08-BKK1132-1B
sf8AdmUl
8
UtranCell=U08-BKK1132-2B
sf8Adm
0
UtranCell=U08-BKK1132-2B
sf8AdmUl
8
UtranCell=U08-BKK1132-2C
sf8Adm
0
UtranCell=U08-BKK1132-2C
sf8AdmUl
4
UtranCell=U08-BKK1132-1C
sf8Adm
0
UtranCell=U08-BKK1132-1C
sf8AdmUl
4
UtranCell=U08-BKK1132-2A
sf8Adm
8
UtranCell=U08-BKK1132-2A
sf8AdmUl
8
================================================================================
=================================
RNSNK11> set UtranCell=U08-BKK1132-1B sf8Adm 8
130222-10:40:24 10.229.70.14 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/16576
Set sf8Adm on following 1 MOs ?
================================================================================
===
17297 RncFunction=1,UtranCell=U08-BKK1132-1B
================================================================================
===
Set sf8Adm on 1 MOs. Are you Sure [y/n] ? y
================================================================================
============================
Id MO
sf8Adm
Result
================================================================================
============================
17297 UtranCell=U08-BKK1132-1B
8
>>> Set.
================================================================================
=================================
++++++ Command to adjut out sync parameter ++++++++
================================================================================
=================================
RNRST01> get u08-BKK2942.* noutsyncind

130226-18:12:59 10.229.66.4 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/18678


================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK2942-1B
nOutSyncInd
20
UtranCell=U08-BKK2942-1C
nOutSyncInd
10
UtranCell=U08-BKK2942-2A
nOutSyncInd
20
UtranCell=U08-BKK2942-2B
nOutSyncInd
20
UtranCell=U08-BKK2942-2C
nOutSyncInd
10
UtranCell=U08-BKK2942-1A
nOutSyncInd
20
================================================================================
=================================
minPwrMax 0->10 minPwrRl -150 to -120
RNRST08
RNRST08> get u08-bkk2874.* minpwrmax
130313-11:15:57 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/9950
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK2874-2A
minPwrMax
0
UtranCell=U08-BKK2874-2B
minPwrMax
20
UtranCell=U08-BKK2874-2C
minPwrMax
20
UtranCell=U08-BKK2874-1A
minPwrMax
0
UtranCell=U08-BKK2874-1B
minPwrMax
20
UtranCell=U08-BKK2874-1C
minPwrMax
20
================================================================================
=================================
Total: 6 MOs
RNRST08> get u08-bkk2874.* minpwrrl
130313-11:16:10 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/9950
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK2874-2A
minPwrRl
-150
UtranCell=U08-BKK2874-2A
minPwrRlTdd
-24
UtranCell=U08-BKK2874-2B
minPwrRl
-150
UtranCell=U08-BKK2874-2B
minPwrRlTdd
-24
UtranCell=U08-BKK2874-2C
minPwrRl
-150
UtranCell=U08-BKK2874-2C
minPwrRlTdd
-24
UtranCell=U08-BKK2874-1A
minPwrRl
-150
UtranCell=U08-BKK2874-1A
minPwrRlTdd
-24
UtranCell=U08-BKK2874-1B
minPwrRl
-150
UtranCell=U08-BKK2874-1B
minPwrRlTdd
-24
UtranCell=U08-BKK2874-1C
minPwrRl
-150
UtranCell=U08-BKK2874-1C
minPwrRlTdd
-24
================================================================================
=================================
Total: 6 MOs

RNRST08> pmx u08-bkk2874-1B -m 23 -h rabreleasespeech


================================================================================
=================================
++++++ Command to check VSWR ++++++++
================================================================================
=================================
BKK2874-U08> lh ru fui get vswr
130325-14:11:04 10.232.12.8 8.0v RBS_NODE_MODEL_N_1_50 stopfile=/tmp/82
================================================================================
=============
$ lhsh 000100/port_0_dev_6 fui get vswr
0001p0d6: vswr: 25.3[dB]
================================================================================
=============
$ lhsh 000100/port_1_dev_7 fui get vswr
0001p1d7: vswr: 20.4[dB]
================================================================================
=============
$ lhsh 000100/port_2_dev_8 fui get vswr
0001p2d8: vswr: 23.8[dB]

RNRST08> h cedr
********************************************************************************
*******
ced[h][r][p] [-m <module(s)>|-c <utrancell>|-r <iublink>] [ | <unix cmds>]
********************************************************************************
*******
Print consumption of cell resources and rbs hw (RNC only).
The following COLI commands are run on the module MPs in RNC:
- celldata (ced/cedr) --> shows dynamic utrancell data, consumption of air inte
rface resources
- hwm (cedh/cedhp/cedhr) --> shows rbs Channel Elements consumption and number
of RadioLinks/UEs
Switches:
- "r": re-read the data, otherwise,
- "p": prints the CE consumption in
nd).
- "h": when the "h" switch is used,
on Iub level, when the "h" switch is
.

cached data is re-parsed.


percentage (only applicable to "cedh" comma
the resources consumption values are shown
not used, they are shown on UtranCell level

Options:
-m <module(s)>: only fetch/parse the data for certain RncModules, e.g. "-m 8" o
r "-m 1,2,3"
-c <utrancell>: only fetch/parse the data for specific UtranCells, e.g. "-c cel
l304A" (not case sensitive)
-r <iublink> : only fetch/parse the data for specific IubLinks, eg. "-r iub_30
4" (not case sensitive)
The output can be filtered by piping through some unix commands, eg. grep or sor

t.
Examples:
>> ced | grep 0019sp0
>> ced | sort -k 5
>> cedh -m 8,9,10
>> ced -r iub_304
ub_304
>> cedh -c cell304a
ell304A

-->
-->
-->
-->

print
print
print
print

all cells configured on CC device 001900/sp0


cell data sorted on the fifth field
CE usage for all sites in modules 8, 9, 10.
cell data for all cells belonging to IubLink=I

--> print CE usage for the site connected to UtranCell=c

Printout format:
> ced
--------------------------------------------------------------------------------------------------------------------------------------------MOD
CELL cid fro ro PwrDl/Adm dlCode ulInt sf8d sf8u sf16d sf16u sf32d
sf4u dlASE ulASE HScnt EULs EULns CPMcnt CC_SP
--------------------------------------------------------------------------------------------------------------------------------------------1 Iub-1-1 1031
0 0 7.0% 75% 6.2% -111.8 0/8 0/8 0/16 0/16 0/32
0/4 0/500 0/500 0/10 1/32 0/100 0/15 1:0019sp1
1 Iub-1-2 1032
1 2 7.0% 75% 6.2% -111.8 0/8 0/8 0/16 0/16 0/32
0/4 0/500 0/500 0/10 4/32 0/100 0/15 1:0021sp1
1 Iub-1-3 1033
2 3 7.0% 75% 22.9% -111.8 1/8 0/8 0/16 1/16 0/32
0/4 39/500 8/500 0/10 3/32 0/100 0/15 1:0019sp1
1 Iub-2-1 1037
6 1 7.0% 75% 24.6% -111.8 1/8 0/8 0/16 2/16 1/32
0/4 53/500 20/500 0/10 0/32 0/100 0/15 1:0019sp1
1 Iub-2-2 1038
7 4 7.0% 75% 10.8% -111.8 0/8 0/8 0/16 2/16 1/32
0/4 12/500 19/500 1/10 0/32 0/100 0/15 8:0023sp1(!)
> cedh
-----------------------------------------------------------------------------------------------------------------------------------------MOD GRP IUBLINK fro ro nCell usedCEdl usedCEul
gHoCEdl
gHoCEul OtherCEd
l OtherCEul dlRL ulRL nrUE leakingCellFroIds
-----------------------------------------------------------------------------------------------------------------------------------------1 0 b0157MDN
0 0
3
34/64 98/256
30/64
158/256
29/6
3
155/253 46 46 46
1 4 b0423MDN
5 2
2
2/64
6/128
62/64
122/128
61/6
3
120/126
3
3
3
1 8 b0407MDN
8 4
1
8/64 42/256
56/64
214/256
55/6
3
211/253 15 15 15
1 10 b0106MDN
9 5
3
40/96 125/256
56/96
131/256
55/9
5
128/253 48 48 49 147
> cedhp
-----------------------------------------------------------------------------------------------------------------------------------------MOD GRP IUBLINK fro ro nCell usedCEdl usedCEul
gHoCEdl
gHoCEul OtherCEd
l OtherCEul dlRL ulRL nrUE leakingCellFroIds
-----------------------------------------------------------------------------------------------------------------------------------------1 0 b0157MDN
0 0
3
53.1%
38.3%
46.9%
61.7%
46.0
%
61.3% 46 46 46
1 4 b0423MDN
5 2
2
3.1%
4.7%
96.9%
95.3%
96.8
%
95.2%
3
3
3
1 8 b0407MDN
8 4
1
12.5%
16.4%
87.5%
83.6%
87.3
%
83.4% 15 15 15
1 10 b0106MDN
9 5
3
41.7%
48.8%
58.3%
51.2%
57.9

50.6%

48

48

49 147

The fields in the "ced" printout correspond to the following variables in the "c
elldata" printout on Module MP:
- MOD: RNC Module
- cid: cId
- fro: cellFroId (facade resource object, a unique id in the node)
- ro: cell RO (resource object, a unique id in the module. Same as capsule inde
x.)
- PwrDl/PwrAdm: Filtered DL Power / pwrAdm
- dlCode: DL Code Allocation Level
- ulInt: UL Interference
- sf8dl: SF8 RL DL Count / sf8Adm
- sf8ul: SF8 RL UL Count / sf8AdmUl
- sf16dl: SF16 RL DL Count / sf16Adm
- sf16ul: SF16 RL UL Count / sf16AdmUl
- sf32dl: SF32 RL DL Count / sf32Adm
- sf4ul: SF4 RL UL Count / sf4AdmUl
- dlASE: Total ASE DL / aseDlAdm
- ulASE: Total ASE UL / aseUlAdm
- HScnt: HSDPA UE Count / hsdpaUsersAdm
- EULs: EUL UE Count serving / eulServingCellUsersAdm
- EULns: EUL UE Count non-serving / eulNonServingCellUsersAdm
- EUL2ms: EUL2ms UE Count serving / eulServingCellUsersAdmTti2
- Spch: Speech Only UE Count
- CPMcnt: CPM RL Count / compModeAdm
- Crn:
Crnti allocation count
- Hrn:
Hrnti allocation count
- CC_SP: The RncModule and SPM of the CC device handling the Cell. If the RncM
odule controlling the CC device is different from the one controlling the cell,
an exclamation mark (!) is printed, since this indicates that some performance p
roblems may occur.
The fields in the "cedh" printout correspond to the following variables in the "
hwm print grp" printout on Module MP:
- MOD: RNC Module
- GRP: Cell Group (one or two per IubLink)
- IUBLINK: the MO id of the IubLink
- fro: the froId of the IubLink (facade resource object id, a unique id in the
node)
- ro: the RO Id of the IubLink (resource object id, unique in the module. Same
as capsule index).
- nCell: the number of UtranCells in the Cell Group
- usedCEdl/usedCEul: Consumed Credit / Capacity Credit . The number of used CE
out of the total amount of available CE. The total amount of available CE is cal
culated in each RBS, based on the HW capability and the licensed capacity.
- gHoCEdl/gHoCEul: Guaranteed, HO (Channel Elements availability for Guaranteed
, Handover traffic)
- OthrCEdl/OthrCEul: Other (Channel Elements availability for Other traffic)
- dlRL, ulRL: number of Radio Links used in the RBS. The two values (downlink a
nd uplink) should always be equal.
- nrUE: number of UEs in the RBS. This should be equal to the number of Radio L
inks.
- leakingCellFroIds: the froId of Cells where dlRL, ulRL, nrUE are not equal. T
his indicates that some resource has not been released properly in the cell. To
release the resources in a leaking Cell, the corresponding IubLink MO must be lo
cked and unlocked.

RNRST08> get bkk2874 ^remotecp


130325-14:50:33 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
IubLink=Iub_BKK2874-U08
remoteCpIpAddress1 10.23
3.12.8
IubLink=Iub_BKK2874-U08
remoteCpIpAddress2
================================================================================
=================================
Total: 1 MOs
RNRST08> get bkk2874 iub
130325-14:50:41 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980
================================================================================
=================================
MO
Attribute
Value
================================================================================
=================================
UtranCell=U08-BKK2874-2A
iubLinkRef
IubLin
k=Iub_BKK2874-U08
UtranCell=U08-BKK2874-2B
iubLinkRef
IubLin
k=Iub_BKK2874-U08
UtranCell=U08-BKK2874-2C
iubLinkRef
IubLin
k=Iub_BKK2874-U08
UtranCell=U08-BKK2874-1A
iubLinkRef
IubLin
k=Iub_BKK2874-U08
UtranCell=U08-BKK2874-1B
iubLinkRef
IubLin
k=Iub_BKK2874-U08
UtranCell=U08-BKK2874-1C
iubLinkRef
IubLin
k=Iub_BKK2874-U08
IubLink=Iub_BKK2874-U08
IubLinkId
Iub_BK
K2874-U08
IubLink=Iub_BKK2874-U08
iubLoadDlThresholdSpeech
Struct{5}
>>> 1.amr5900 = 100
>>> 2.amr7950 = 100
>>> 3.amr12200 = 100
>>> 4.amrWb8850 = 100
>>> 5.amrWb12650 = 100
IubLink=Iub_BKK2874-U08
iubLoadUlThresholdSpeech
Struct{5}
>>> 1.amr5900 = 100
>>> 2.amr7950 = 100
>>> 3.amr12200 = 100
>>> 4.amrWb8850 = 100
>>> 5.amrWb12650 = 100
================================================================================
=================================
Total: 7 MOs
RNRST08> cedr -r Iub_BKK2874-U08
130325-14:51:02 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980

Trying password from ipdatabase file: /opt/ericsson/amos/moshell/sitefiles/ipdat


abase...
Checking available boards on node...
................
.........................
Created following board-groups: all, allp, mp, bp, tu, coremp, ommp, scb, sxb, s
cx, sccpmp, et, etmfg, etmfx, aal2ap, aal2ncc, aal2cpsrc, aal2rh, xp, ranapmp, r
nsapmp, mod, modact, modsb, modpdr, mod<sr>, mod<mod>,
cc, cc<sr>, cc<mod>, dc, dc<sr>, dc<mod>, pdr, p
dr<sr>, pdr<mod>, alld, spb, spb<sr>, spb<mob>.
>>> Type "bp" to view available board-groups and "bp <group>" to view group cont
ents.
Created following MO-groups: cc[0-9]dev, dc[0-9]dev, pdr[0-9]dev.
>>> Type "mp" to view available MO-groups and "pr <group>" to view group content
s.
................................................................................
................................................................................
......................................................................
..put /var/opt/ericsson/amos/moshell_logfiles/OS2133/logs_moshell/tempfiles/2013
0325-144908_15931/lhCmd15980 /d/usr/lhCmd15980 ... OK
....
-----------------------------------------------------------------------------------------------------------------------------------------MOD
CELL cid fro ro PwrDl/Adm dlCode ulInt sf8d sf8u sf16d sf16u
sf32d sf4u dlASE ulASE CPMcn HScnt EULs EULns Eul2 Spch CC_SP
-----------------------------------------------------------------------------------------------------------------------------------------1081 U08-BKK2874-1A 6493 465 24 54.6% 75% 38.1% -96.3 0/8 0/8 0/16 2/50
0/32
1/4 19/500 70/500 4/15 22/64 19/32 5/100 4/4
1 13 22 1081:00
20sp0
1081 U08-BKK2874-1B 6501 466 25 31.2% 75% 21.0% -98.2 0/8 0/4 0/16 0/50
0/32
0/0 5.0/500 3.6/500 1/15 6/64 6/32 0/100 3/4
0 1 6 1081:00
20sp0
1081 U08-BKK2874-1C 6502 467 26 33.9% 85% 20.4% -96.2 0/8 0/8 0/16 0/50
0/32
0/4 5.2/500 3.0/500 2/15 3/64 3/32 0/100 1/4
1 5 3 1081:00
20sp0
1081 U08-BKK2874-2A 6503 468 27 45.8% 75% 29.5% -94.7 0/8 0/0 0/16 3/50
0/32
0/0 14/500 21/500 1/15 15/64 12/32 2/100 0/0
3 13 15 1081:00
20sp0
1081 U08-BKK2874-2B 6511 469 28 27.4% 75% 15.3% -101.2 0/8 0/8 0/16 0/50
0/32
0/4 1.2/500 1.8/500 0/15 3/64 3/32 1/100 1/4
0 1 3 1081:00
20sp0
1081 U08-BKK2874-2C 6512 470 29 31.4% 85% 17.0% -94.5 0/8 0/8 0/16 2/50
0/32
0/4 2.6/500 17/500 1/15 4/64 2/32 1/100 0/4
0 2 4 1081:00
20sp0
-----------------------------------------------------------------------------------------------------------------------------------------Total (6 cells):
0
0
0
7
0
1
47 116.4
9
53
45
9
9
5 35 53
------------------------------------------------------------------------------------------------------------------------------------------

Вам также может понравиться