OWNER KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT

CONTRACTOR

Document Title:
Date:17/08/2007

DATA SHEET FOR MOTOR PM-5504 A/B


Rev: 0 Class: II Sheet 1 of 2

Document No: DS-55-E-PM5504

DATA SHEET FOR MOTOR PM-5504 A/B

0 A Rev

Issued for Construction Issued for Approval Description

8/17/2007 6/26/2007 Date

ARS ARS Prepared

SN SN Checked

ShS ShS Approved

LiuXG LiuXG CPECC Owner

OWNER KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT

CONTRACTOR

Document Title:
Date:17/08/2007

DATA SHEET FOR MOTOR PM-5504 A/B


Rev: 0 Class: II Sheet 2 of 2

Document No: DS-55-E-PM5504

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49

MOTOR APPLICATION PAK005 Project Kandhkot Field Gas Compression Station Project Project Number CPECC PM-5504 A/B Client Tag Number Location Kandhkot, Sindh Number Required 2 Service Jockey Fire Water Pump MOTOR DETAILS Company Requirements Vendor Details Rated output kW Manufacturer 3* Supply Volts Frame number 415 3 Ph 50 Hz System neutral earthing: Solid x Resistive Full load speed rpm Synchronous speed rpm Full load torque N.m Enclosure rating (IEC60529) Motor:IP Locked rotor torque N.m 55 Terminal Box/Cable Entry Size:IP Pull-out torque N.m 56 N/L 1/2 3/4 F/L Duty rating Current Amps S1 N/L 1/2 3/4 F/L Insulation class Efficiency % F 1/2 3/4 F/L Temperature rise limit Power factor N/L Class B (7.6 x IFLC) Starting torque designation Locked rotor current Amps IC Winding protection Yes No x Cooling method Anticondensation Heater Yes No x Motor cool down time mins Max. stalled time hot cold secs Starting power factor IM Const. type & mounting arrgt ENVIRONMENTAL DETAILS Design ambient temperature (Min/Max) C Motor explosion protection 6/53 Area classification: Hazardous Non-hazardous x Certifying body Hazardous protection type Certificate No. Gas Group: Temperature Class: MECHANICAL DETAILS Bearing type: DE: NDE: Drive system: Direct x V-belt Geared Bearing manufacturer Load moment of inertia Lubrication system kg.m Slide rails required Yes No x Shaft end float mm Required to have reversing duty:Yes No x Rotor moment of inertia kg.m Maximum noise level at one metre dB(A) Motor weight kg Shipping dimensions Lx Wx H Run direction from DE CW CCW CABLE DETAILS Main power cable TBA Cable entry direction Terminal box location (viewed from drive end) Vertical Anti-condensation heater cable # Size of screwed entry X M NA Thermistor/RTD cable NA NOTES Vendor to provide detail. * Vendor Shall Confirm Motor Rating. TBA To Be Advised 1 Vendor to provide details on the right hand side of Data Sheet. 2 Vendor shall provide a routine test certificate for each motor.

Вам также может понравиться