BD35F

Direct Current Compressor


R134a
12 - 24V

Compressors

Data Sheet (Replaces CD.46.A7.02)


Code numbers
101Z0200

BD35F

single: 101N0210, 30 pcs: 101N0211

Electronic unit 12-24V DC - w. metal shielding single: 101N0220, 30 pcs: 101N0221


Electronic unit 12-24V DC - with AEO

101Z

Application

R134a

Blue stripe

single: 101N0300, 30 pcs: 101N0301

N 1297

Barcode on
white background

Application
Application

LBP/MBP/(HBP)

Evaporating temperature range

0200

MADE IN GERMANY

Grey background

-30 to 0 (10)
12 - 24V DC / 31.5V DC

Comp. cooling at ambient temp.

0277 00

* depending on application

Design
Displacement

cm

2.00

Oil quantity

cm 3

150

300

870

Maximum refrigerant charge


Free gas vol. in compressor

cm

Weight: Compressor/Electronic unit

kg

EC approval mark
(electronic unit)
S
O
F1

4.3/0.25
F2

Motor
Motor type

Approvals

THERMALLY
PROTECTED
SYSTEM

Approval mark

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Variable speed

Resistance, all 3 windings (25 C)

BD35F
12/24V DC

e4

55
S or F1*

43 C

8369-7

Max. machine compartment temperature

8415

Voltage range / max. voltage

8369

BD35F without electronic unit


Electronic unit 12-24V DC - standard

204
170

2.3
E4 72/245 95/54 0277 00, UL984, CSA-C22.2

Dimensions

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

12V cut-in [V]


11.7

24V cut-out [V]


22.8

24V cut - in [V]


24.2

April 2004

[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6

[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9

70
100

B1 B A
20

12V max. 24V cut-out 24V cut-in 24V max.


Voltage
[V]
[V]
Voltage
17.0
21.3
22.7
31.5
17.0
21.5
22.9
31.5
17.0
21.8
23.2
31.5
17.0
22.0
23.4
31.5
17.0
22.3
23.7
31.5
17.0
22.5
23.9
31.5
17.0
22.8
24.2
31.5
17.0
23.0
24.5
31.5
17.0
23.3
24.7
31.5
17.0
23.6
25.0
31.5
17.0
23.8
25.2
31.5
17.0
24.1
25.5
31.5
17.0
24.3
25.7
31.5
17.0
24.6
26.0
31.5
31.5
CD.46.A8.02

201
8269

16

105

[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220

127

B2

Optional battery protection settings


Resistor (R2) 12V cut-out 12V cut-in

150

Standard battery protection settings (no connection C - P)


12V cut-out [V]
10.4

4.2

28

130

Compressors on a pallet

16

46

location/I.D. mm

137
135
128

59

Suction connector

A
B
B1

78.5

mm

120

Height

123

Capacity (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
3,500

-30
15.8
20.2
22.5
26.2

-25
23.9
29.9
32.4
35.9

watt

-23.3
26.9
33.5
36.5
40.4

-20
33.1
41.2
45.4
50.5

-15
43.8
54.6
61.8
69.8

-10
56.6
70.7
81.7
93.6

-5
71.7
89.7
105
122

0
89.9
112
133

5
111
139

-23.3
33.1
41.3
44.9
49.7

-20
40.7
50.7
55.9
62.2

-15
54.0
67.3
76.1
86.0

-10
69.8
87.1
101
115

-5
88.6
111
130
150

0
111
139
164

5
137
172

10
136
Terminal plug

Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500

-30
19.5
24.9
27.7
32.2

watt

-25
29.4
36.8
39.9
44.2

10
169

8236-2

Power consumption
rpm \ C
2,000
2,500
3,000
3,500

-30
17.6
23.3
29.9
36.0

watt

-25
23.4
30.9
36.0
42.8

-23.3
25.3
33.3
38.3
45.4

-20
28.7
37.8
43.0
50.8

-15
33.6
44.1
50.7
59.5

-10
38.3
50.2
58.7
68.9

-5
43.0
56.2
66.8
78.5

0
48.0
62.3
74.8

5
53.4
68.7

10
59.5

Current consumption (for 24V applications the following must be halved)


rpm \ C
2,000
2,500
3,000
3,500

-30
1.5
1.9
2.5
3.0

-25
2.0
2.6
3.0
3.6

-23.3
2.1
2.8
3.2
3.8

-20
2.4
3.2
3.6
4.3

-15
2.8
3.7
4.2
5.0

-10
3.2
4.2
4.9
5.7

-5
3.6
4.7
5.6
6.5

0
4.0
5.2
6.2

5
4.5
5.8

-30
0.90
0.87
0.75
0.73
-30
1.10
1.07
0.93
0.89

LED -

Fan

R1
Thermostat

R2

+
F
D
C
P
T

W/W

-25
1.02
0.97
0.90
0.84

-23.3
1.06
1.01
0.95
0.89

-20
1.15
1.09
1.06
1.00

-15
1.31
1.24
1.22
1.17

-10
1.48
1.41
1.39
1.36

-5
1.67
1.60
1.58
1.55

0
1.87
1.80
1.78

5
2.08
2.02

-25
1.25
1.19
1.11
1.03

-23.3
1.31
1.24
1.17
1.09

-20
1.42
1.34
1.30
1.23

-15
1.61
1.53
1.50
1.44

-10
1.82
1.74
1.72
1.68

-5
2.06
1.97
1.95
1.91

0
2.31
2.23
2.20

5
2.57
2.50

10
2.29

COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500

Power supply

10
5.0

COP (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
3,500

Main switch

Fuse

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 12V DC
1 Watt = 0.86 kcal/h

EN 12900/CECOMAF
55 C
32 C
55 C

ASHRAE
55 C
32 C
32 C

Operational errors shown by LED (optional)

Accessories
Devices

Compressor speed
Electronic Resistor
unit
(R1)

0
0
1
277
02 220
1N 0
692
10 01N
1523
1
0
173
00
3
0 EO
450
1N h A
0
865
i
1 wt
1696

Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500

10
2.84

Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2

In AEO (Adaptive Energy Optimizing) speed


mode the BD compressor will always adapt
its speed to the actual cooling demand.

Number
of
flashes

Error type

Thermal cut-out of electronic unit

Minimum motor speed error

Motor start error

Fan over-current cut-out

BD35F

Standard automobile fuse


Not
DIN 7258
12V: 15A
deliverable
24V: 7.5A
from Danfoss
Mounting accessories
Bolt joint for one compressor 118-1917
Bolt joint in quantities
118-1918
Snap on in quantities
118-1919

Wire dimensions
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
section

Gauge

mm2

ft.

ft.

12
12
10
8

2.5
4
6
10

8
13
19.5
32.8

2.5
4
6
10

16
26
39
65.6

5
8
12
20

(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).

(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).

Battery protection cut-out


(The voltage is outside the cut-out setting).

*Length between battery and electronic unit