RECEIVE PATH SPECIFICATIONS Frequency Range Rx gain Gain variation 1850-1910 MHz 12/33 dB +/- 0.8 dB max. at room temperature +/- 1.0 dB max. over entire operating temperature range
Noise Figure
1.9 dB max. at room temperature 2.2 dB max.over entire operating temperature range
TRANSMIT PATH SPECIFICATIONS Frequency Range Tx insertion loss Return loss Intermodulation 1930-1990 MHz 0.8 dB max. 18.0 dB -115 dBm ( Rx band 3rd order; 2 x 43dBm )
DATASHEET
2 (3)
28.10.2008
MHA POWER HANDLING Input power on ANT port: RX band Interferers in GSM850 Interferers in WCDMA2100 Interferers in 2.62-2.69GHz +5 dBm min. +20 dBm min. +16 dBm min. +16 dBm min.
MECHANICAL SPECIFICATIONS Dimensions (H x W x D) 295 x 210 x 65 Volume Weight RF connector type RET connector Grounding Stud 4 litre approx 5 kg approx. 7-16 female IEC 60130-9 as in AISG M8
ENVIRONMENTAL SPECIFICATIONS Operating temperature Enclosure protection Lightning protection MTBF -40 - +55C IP67 In accordance with IEC 801-5 and IEC 61312 450 000 hours
DATASHEET
3 (3)
28.10.2008
INSTALLATION Wall Mounting Pole Mounting Using 4 x M8 bolts or screws Pole diameter 40 110mm, using hose band clamps
Orientation Powering
Can be installed in multiple orientations in current window mode via BTS1 and BTS2 in AISG mode via BTS1 (WCDMA Flexi and Siemens BTS) AISG and DC pass-trough BTS1 -> ANT1
OTHERS Compatibility Nokia UltraSite GSM/EDGE BTS, Nokia Flexi GSM/EDGE and WCDMA, Siemens BTS with MFDUAMCO
ORDERING CODES