Вы находитесь на странице: 1из 64

INDURE

101
101

R04

R05

R01

4RLA

REL670

R02

125
137
149
101 107 101 107 101

301 307 301 307 301

143
113 119 101 107 113

155
101

101
119
101 107 113 101

301

143
101

313 319 301 307 313

119 125
101 101

301 307 313

101
101

R06

301

7SA522

R01

101
RAICA

R03

R04
101
101

4RLB

113 119

R02

101
119
101 107 113 101

313 319

R05

301 307 313

143
155
101 107 101

301 307 301

REL670

R02

149
137
125
101 107 101 107 101

301 307 301 307 301

R01

R04
101
101

119
101
101 113 107 101

R05
143
113 107 101 119 113

313 307 301

143
101

301

125 119
101 101

301

101
101

R06

313 307 301 319 313

155
101

301

LK13

MCB 04
FS09,10,11,12,13

MCB01,02
MCB 03

HT
F1
F2

A01.04
TH

A01.02
A01.03

A01
A01.01

15A DC LINK

10A DC MCB
2A DC FUSE

16A DC MCB
6A DC MCB

SPACE HEATER
DOOR SWITCH
CFL LAMP

TOGGLE SWICTH
THERMOSTAT

15A AC LINK
POWER SOCKET

AC MOUNTING PLATE
16A AC FUSE

NOTE:-

- DISCONNECTING TYPE TBs

- NON-DISCONNECTING TYPE TBs

ABB WIRE WAY

CUSTOMER WIRE WAY

R02

R01
7SA522

R03
101
RAICA

R04
101
101

119
101
101 113 107 101

307 301

155
143
101 107 101

119 113

313 307 301

R05

319 313

LK07

MCB05
MCB06
FS03,04,05,06,07

F2

TH
HT
F1

A01.04

A01.02
A01.03

A01
A01.01

15A DC LINK

6A DC MCB
10A DC MCB
2A DC FUSE

CFL LAMP

THERMOSTAT
SPACE HEATER
DOOR SWITCH

TOGGLE SWICTH

15A AC LINK
POWER SOCKET

AC MOUNTING PLATE
16A AC FUSE

NOTE:-

- DISCONNECTING TYPE TBs

- NON-DISCONNECTING TYPE TBs

ABB WIRE WAY

CUSTOMER WIRE WAY

BILL OF MATERIALS

Document Name

GA Drawing
Schematic Diagram
Wiring Table
Label list

Identity
YN1M301134-AAB
YN1M301134-CAB
YN1M301134-DAB
YN1M301134-LAB

REVISION TABLE
Rev.No.
01
02

Des ign Checked by


NAGENDRA

Drawing Checked by
B.MANJUNATHA
Drawn By
QCS

Revision Note
Revised as per customer comments
Revised as per customer comments

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLA
Issued by
SASE

Year
07

Week
25

Approved
NGR
NGR

Week
07 43
07 43

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AB
Sheet
BILL OF MATERIALS

1/4

Item
Designation
4RLA + 01

Designation/
Make
Relay Panel

4RLA+02

Base Frame

4RLA+A01

4RLA+HS

AC MOUNTING
PLATE
Fuse Base, Fuse
Link
Fuse Base, Neutral
Link
UNIVERSAL
SOCKET
TOGGLE SWITCH

4RLA+TH

THERMOSTAT

4RLA+HT
4RLA+DS

SPACE HEATER
DOOR SWITCH

4RLA+FL

CFL LAMP

4RLA+MCB01,02

MCB FOR DC
SOURCE-1/2

4RLA+MCB03

MCB for MAIN-I


PROTN & GR-A
TRIP RELAY
CIRCUIT
MCB for BREAKER
TC-1
Fuse Base, Fuse
Link

4RLA+A01.01
4RLA+A01.02
4RLA+PS

4RLA+MCB04
4RLA+FS09,10,11,
12,13
4RLA+LK13

Fuse Base, Neutral


Link

4RLA+R01

MAIN-I
PROTECTION
RELAY REL670

Des ign Checked by


NAGENDRA

Drawing Checked by
B.MANJUNATHA
Drawn By
QCS

Type,
Technical Data
SIMPLEX VTG700 RELAY PANEL
2147mm (H)+700mm(W)+ 930mm(D)
ANTIVIBRATION PAD=15mm
Paint shade: LIGHT GREY IS:631(External)
Internal: White(Glossy)
100mm Height Base frame: Black glossy
finish
Mounting plate for 1 Fuse,1 Link,1 Power
socket and 1 Toggle switch.
Fuse Base with HRC Fuse Link
Rating: 16A
Fuse Base with Neutral Link
Rating: 15A
Universal Socket (Box type) With switch
Rating:5A/15A 230V AC
ON/OFF, 1 Pole
Rating 5A, 230V AC
Thermostat, 30D to 90D
Rating: 15A, 230V AC
Space heater, Rating: 50W, 230V AC
Single pole, Rating:5A,230 V AC

Qty
1

Order
Information
YN1M301134-UA

INCLD. ABOVE

1MYN588005-003

1MYN567003-E

1MYN567004-A

1MYN538103-001

IN5399-3002-1

IN7635-3001

1
1

IN6677-3001-2
IN5374-3001-1

COMPACT FILAMENT LAMP


Rating: 12W 230V AC
Make:ABB Type:DC Series, 2pole
Rating:16A 220V DC,Aux contacts:1C/O+1N/C

3BYN591500-001

S282UC16

Make:ABB Type:DC Series, 2pole


Rating:6A 220V DC,Aux contacts:1C/O+1N/C

S282UC6

Make:ABB Type:DC Series, 2pole


Rating:10A 220V DC,Aux contacts:1C/O+1N/C
Make: BUSSMAN/EQUI
Fuse Base with HRC Fuse Link
Rating: 2A
Make: BUSSMAN/EQUI
Fuse Bas e with Neutral Link
Rating: 15A
Make: ABB, Type:REL670 with SPA / IEC-103
Communication protocol,
Size:6U,3/4 x 19",
Current rating:1A,
Voltage rating:110V AC,
Aux DC Voltage : 220V DC
Analog Input : 6I+6U
No. of IO Module : 3 (8-I/P, 12-o/p on each

S282UC10

1MYN567002-A

1MYN567004-A

1MYN743301-BB

1MRK00173-CC

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLA
Issued by
SASE

Year
07

Week
25

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AB
Sheet
BILL OF MATERIALS

2/4

Item
Designation

4RLA+R02

4RLA+R04,R05,R06
4RLA+R04.101.101

Designation/
Make

CARRIER
SELECTOR
SWITCH
RELAY CASE
TEST SWITCH for
REL670

Type,
Technical Data

Qty

IOM)
Provided with :1. Distance Protection (5Zone)
2. Auto-Recloser
3. Over Voltage 2stage
4. Under Voltage 2stage
5. Dir. O/C & E/F
6. Under Frequency 2stage
7. Over Frequency 2stage
8. Fault locator
9. Tripping Logic
10. Disturbance Recorder
11. Event Recorder
12. Time Synch with PPS pulse
Make: Switron, Size:75x88mm 32A,
2 Way 6 Pos, IN-3 Pos, OUT-3 Pos
Wing Type Knob
Make: ABB, Type:RHGX20 Case, Size:4S 60C
Make: ABB, Type: RXTP18, Size: 4S 6C

Order
Information

1MYN533018-001

3
1

IN5609-1200-D
1MYN565010-A

4RLA+R04.125.101,
107

ANNUN.
MULTIPLICATION
RELAY

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:3N/O SR per element,
Aux voltage: 220V DC

INRK271-018-AS

4RLA+R04.125.301,
307

ANNUN.
MULTIPLICATION
RELAY
AUX. RELAY for CB
Trouble

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:3N/O SR per element,
Aux voltage: 220V DC
Make: ABB, Type:RXSF1 2Element,Size:2S,6C
Contacts:3N/O SR per element,
With HR Flag, Aux voltage: 220V DC
Make: ABB, Type:RXSF1 2Element,Size:2S,6C
Contacts:3N/O SR per element,
With HR Flag, Aux voltage: 220V DC
Make: ABB, Type: RXEG21, Size: 4S, 12C
Aux voltage: 220V DC
Voltage SettIng-20-60V
Make: ABB, Type: RXMS1,Size:2S,6C
Contacts:6N/O SR, Aux voltage: 220V DC
Make: ABB, Type: RXME1, Size: 2S, 6C,
Contacts: 2N/O SR Heavy Duty,
Aux voltage: 220V DC
Make: ABB, Type: RXMVB4, Type:RXMVB4,
Size:4S,12C, Contacts: 11N/O +3N/C,
Electrically Reset, Aux. Voltage:48V DC
Make: ABB, Type: RXTMA, Size: 2S, 6C
With 4x390 ohms, 5W resistors
Aux voltage: 220 V DC
Make: ABB, Type: TSR, Size: 2S 6C

INRK271-018-AS

INRK271-018-AS

INRK271-018-AS

INRK411-102-DC

INRK216-263-AS

INRK221-825-AS

INRK251-403-AH

INRK711-004-AM

IN352-001-AS

4RLA+R04.137.101,
107,301
4RLA+R04.137.307

4RLA+R04.149.101,
301
4RLA+R05.101.101,
107,113
4RLA+R05.101.301,
307,313

AUX. RELAY for


CARRIER
RECEIVED
UNDER VOLTAGE
RELAY for Line
E/sw interlock
GR-A 1-PH TRIP
RELAY
GR-A 1-PH TRIP
RELAY

4RLA+R05.119.101

LATCH RELAY
GR-A

4RLA+R05.119.113

Resistor Unit for


RXMVB4 Trip Relay

4RLA+R05.119.313

GR-A RELAY

Des ign Checked by


NAGENDRA

Drawing Checked by
B.MANJUNATHA
Drawn By
QCS

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLA
Issued by
SASE

Year
07

Week
25

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AB
Sheet
BILL OF MATERIALS

3/4

Item
Designation

4RLA+R05.119.119

4RLA+R05.119.319
4RLA+R05.143.101,
107,113
4RLA+R05.143.301,
307,313
4RLA+R06.143.101,
301

Designation/
Make
SUPERVISION
RELAY
PUSH BUTTON
MODULE for
LATCH RELAY
AUX. RELAY for
DTR
BREAKER TC-1
SUPERVISION
RELAY
BREAKER TC-2
SUPERVISION
RELAY
DC Change over
Relay

Type,
Technical Data
Contacts: 2C/O, Aux. voltage: 110/220V DC,
Circuit diagram: IN 7405-3001-A
Push Button unit, Size :2S 6C
Contacts: 2N/O +2N/C

Qty

Order
Information

IN5396-3001-AC

Make: ABB, Type: RXMS1,Size:2S,6C


Contacts:6N/O SR, Aux voltage: 220V DC
Make: ABB, Type: TSR, Size: 2S 6C
Contacts: 2C/O, Aux. voltage: 110/220V DC,
Circuit diagram: IN 7405-3001-A
Make: ABB, Type: TSR, Size: 2S 6C
Contacts: 2C/O, Aux. voltage: 110/220V DC,
Circuit diagram: IN 7405-3001-A
Make :ABB, Type:RXPQ8, Size: 2s,12c
Contacts : 4NO+3NC
Auxiliary Voltage:220V DC
Make: ABB, Type:RXSF1 2Element,Size:2S,6C
Contacts:2N/O+1N/C SR per element,
With SR Reverse Flag, Aux voltage: 220V DC

INRK216-263-AS

IN352-001-AS

IN352-001-AS

1MYN563644-EAD

INRK271-019-AS

4RLA+R06.155.101

AUX. RELAY for DC


Supervision

4RLA+R06.101.101

AUX. RELAY for


TSR

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:3N/O SR per element,
With HR Flag, Aux voltage: 220V DC

INRK271-018-AS

4RLA+R06.101.301

AUX. RELAY for


TSR

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:1N/O+2N/C SR per element,
With HR Flag, Aux voltage: 220V DC

INRK271-009-AS

4RLA+R06.119.101

AUX. RELAY for CB


TROUBLES

INRK271-018-AS

4RLA+R06.125.101

AC. SUPPLY
SUPERVISION
RELAY
TERMINAL BLOCK
TERMINAL BLOCK

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:3N/O SR per element,
With HR Flag, Aux voltage: 220V DC
Type:RXMH2,Size:2S,12C,
Contacts:4N/O+4N/C SR Heavy Duty, With
Operation indicator
Disconnecting, Stud type
Non-Disconnecting, Stud type

4RLA+TB
4RLA+TB

Des ign Checked by


NAGENDRA

Drawing Checked by
B.MANJUNATHA
Drawn By
QCS

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLA
Issued by
SASE

Year
07

Week
25

INRK223-069-ES

set
set

SALE ORDER NO.


4200007483

1MYN266003-002
1MYN266017-001

Rev
02

YN1M301134-AB
Sheet
BILL OF MATERIALS

4/4

BILL OF MATERIALS

Document Name

GA Drawing
Schematic Diagram
Wiring Table
Label list

Identity
YN1M301134-AAB
YN1M301134-CAB
YN1M301134-DAC
YN1M301134-LAC

REVISION TABLE
Rev.No.
01
02

Design Checked by
NAGENDRA

Drawing Checked by
B.M.MANJUNATHA
Drawn By
QCS

Revision Note
Revised as per customer comments
Revised as per customer comments

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLB
Issued by
SASE

Year
07

Week
25

Approved
NGR
NGR

Week
07 43
07 43

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AC
Sheet
BILL OF MATERIALS

1/4

Item
Designation
4RLB + 01

Designation/
Make
Relay Panel

4RLB+02

Base Frame

4RLB+A01

4RLB+HS

AC MOUNTING
PLATE
Fuse Base, Fuse
Link
Fuse Base, Neutral
Link
UNIVERSAL
SOCKET
TOGGLE SWITCH

4RLB+TH

THERMOSTAT

4RLB+HT
4RLB+DS
4RLB+FL

SPACE HEATER
DOOR SWITCH
CFL LAMP

4RLB+MCB05

MCB for MAIN-II


PROTN
MCB for MAIN-II
PROTN
Fuse Base, Fuse
Link

4RLB+A01.01
4RLB+A01.02
4RLB+PS

4RLB+MCB06
4RLB+FS03,04,05,
06,07
4RLB+LK07

Fuse Base, Neutral


Link

4RLB+R03.101

LBB PROTECTION
RELAY

4RLB+R01

MAIN-II
PROTECTION
RELAY 7SA522

Design Checked by
NAGENDRA

Drawing Checked by
B.M.MANJUNATHA
Drawn By
QCS

Type,
Technical Data
SIMPLEX VTG700 RELAY PANEL
2147mm(H)+700mm(W)+ 930mm(D)
ANTIVIBRATION PAD=15mm
Paint shade:LIGHT GREY SHADE IS:631
(External), Internal: White(Glossy)
100mm Height Base frame: Black glossy
finish
Mounting plate for 1 Fuse,1 Link,1 Power
socket and 1 Toggle switch.
Fuse Base with HRC Fuse Link
Rating: 16A
Fuse Base with Neutral Link
Rating: 15A
Universal Socket (Box type) With switch
Rating:5A/15A 230V AC
ON/OFF, 1 Pole
Rating 5A, 230V AC
Thermostat, 30D to 90D
Rating: 15A, 230V AC
Space heater, Rating: 50W, 230V AC
Single pole, Rating:5A,230 V AC
COMPACT FILAMENT LAMP
Rating: 12W 230V AC
Make:ABB Type:DC Series, 2pole
Rating:6A 220V DC, Aux contacts:1C/O+1N/C
Make:ABB Type:DC Series, 2pole
Rating:6A 220V DC, Aux contacts:1C/O+1N/C
Make: BUSSMAN/EQUI
Fuse Base with HRC Fuse Link
Rating: 2A
Make: BUSSMAN/EQUI
Fuse Base with Neutral Link
Rating: 15A
Make: ABB, Type:RAICA,Size:4S,36C,
Current setting:0.2-3A,
Time setting:20ms-99Sec,
Aux voltage:220V DC, Circuit
diagram:IN7429-3002-BA
Make: SIEMENS, Type: 7SA522 with SPA/
IEC-103 station Communication protocol,
Optical interface suitable for ST Connectors,
Size: 6U,1/1 x 19",
Current rating: 1A,
Voltage rating: 230V AC 50Hz,
Aux DC Voltage : 220V DC
Provided with :Provided with :-

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLB
Issued by
SASE

Year
07

Week
25

Qty
1

Order
Information
YN1M301134-UA

INCLD. ABOVE

1MYN588005-003

1MYN567003-E

1MYN567004-A

1MYN538103-001

IN5399-3002-1

IN7635-3001

1
1
1

IN6677-3001-2
IN5374-3001-1
3BYN591500-001

S282UC6

S282UC10

1MYN567002-A

1MYN567004-A

IN330-283-BA

YN1M301134-SC

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AC
Sheet
BILL OF MATERIALS

2/4

Item
Designation

Designation/
Make

4RLB+R02

CARRIER
SELECTOR
SWITCH

4RLB+R03,R04,R0
5
4RLB+R04.101.101

RELAY CASE

4RLB+R04.143.101.
107
4RLB+R04.143.301,
307
4RLB+R04.155.101

4RLB+R04.155.301

TEST SWITCH for


7SA522
ANNUN.
MULTIPLICATION
RELAY
ANNUN.
MULTIPLICATION
RELAY
AUX. RELAY for
CARRIER
RECEIVED
AUX. RELAY for
LBB

4RLB+R05.101.101,
107,113
4RLB+R05.101.301,
307,313

GR-B 1-PH TRIP


RELAY
GR-B 1-PH TRIP
RELAY

4RLB+R05.119.101

LATCH RELAY
GR-B

4RLB+R05.119.113

Resistor Unit for


RXMVB4 Trip Relay

4RLB+R05.119.313

GR-B RELAY
SUPERVISION
RELAY

Design Checked by
NAGENDRA

Drawing Checked by
B.M.MANJUNATHA
Drawn By
QCS

Type,
Technical Data
1. Distance Protection (5Zone)
2. Auto-Recloser
3. Over Voltage 2stage
4. Under Voltage 2stage
5. Dir. O/C & E/F
6. Under Frequency 2stage
7. Over Frequency 2stage
8. Fault locator
9. Tripping Logic
10. Disturbance Recorder
11. Event Recorder
12. Time Synch with PPS pulse
Make: Switron
Size:75x88mm 32A,
2 Way 6 Pos, IN-3 Pos, OUT-3 Pos
Wing Type Knob
Make: ABB, Type:RHGX20 Case, Size:4S 60C

Order
Information

1MYN533018-001

IN5609-1200-D

Make: ABB, Type: RXTP18, Size: 4S 6C

1MYN565010-A

Make: ABB, Type:RXSF1 2Element,Size:2S,6C


Contacts:3N/O SR per element,
Aux voltage: 220V DC
Make: ABB, Type:RXSF1 2Element,Size:2S,6C
Contacts:3N/O SR per element,
Aux voltage: 220V DC
Make: ABB, Type:RXSF1 2Element,Size:2S,6C
Contacts:3N/O SR per element,
With HR Flag, Aux voltage: 220V DC
Make: ABB, Type:RXMS1 ,Size:2S,6C
Contacts:6N/O SR
Aux voltage: 220V DC
Make: ABB, Type: RXMS1,Size:2S,6C
Contacts:6N/O SR, Aux voltage: 220V DC
Make: ABB, Type: RXME1, Size: 2S, 6C,
Contacts: 2N/O SR Heavy Duty,
Aux voltage: 220V DC
Make: ABB, Type: RXMVB4, Type:RXMVB4,
Size:4S,12C, Contacts: 11N/O +3N/C,
Electrically Reset, Aux. Voltage: 48V DC
Make: ABB, Type: RXTMA, Size: 2S, 6C
With 4x390 ohms, 5W resistors
Aux voltage: 220 V DC

INRK271-018-AS

INRK271-018-AS

INRK271-018-AS

INRK216-063-AS

INRK216-263-AS

INRK221-825-AS

INRK251-403-AH

INRK711-004-AM

Make: ABB, Type: TSR, Size: 2S 6C


Contacts: 2C/O, Aux. voltage: 110/220V DC,
Circuit diagram: IN 7405-3001-A

IN352-001-AS

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLB
Issued by
SASE

Qty

Year
07

Week
25

SALE ORDER NO.


4200007483

Rev
02

YN1M301134-AC
Sheet
BILL OF MATERIALS

3/4

Item
Designation
4RLB+R05.119.119

4RLB+R05.119.319
4RLB+TB
4RLB+TB

Design Checked by
NAGENDRA

Drawing Checked by
B.M.MANJUNATHA
Drawn By
QCS

Designation/
Make
PUSH BUTTON
MODULE for
LATCH RELAY
AUX. RELAY for
DTR
TERMINAL BLOCK
TERMINAL BLOCK

Type,
Technical Data
Push Button unit, Size :2S 6C
Contacts: 2N/O +2N/C
Make: ABB, Type: RXMS1,Size:2S,6C
Contacts:6N/O SR, Aux voltage: 220V DC
Disconnecting, Stud type
Non-Disconnecting, Stud type

400kV PROTECTION PANEL


NEW LINE FEEDER
SURATGARH SUPER THERMAL POWER
STATION STG-IV: 1*250MW (UNIT#6)
FOR PANEL: 4RLB
Issued by
SASE

Qty
1

Year
07

Week
25

1
set
set

SALE ORDER NO.


4200007483

Order
Information
IN5396-3001-AC

INRK216-263-AS
1MYN266003-002
1MYN266017-001

Rev
02

YN1M301134-AC
Sheet
BILL OF MATERIALS

4/4

X11-89AAE

X11-89ABE

X11-89ACE

LINE TRAP

360KV, 10KA

X11-89AA

400kV MAIN BUS-I


400kV MAIN BUS-II

X11X12-89BT

X12-89AAE

X12-89AA

X12-89AB

X12-89ABE

X12-52

X11X12-52
P1
P2
X11X12-CT-B

X12-89AC

X12-89ACE

LINE TRAP

360KV, 10KA

FUTURE LINE

X12-CVT

X11-52

P2
P1
X11X12-CT-A

X11X12-89BTE

P1
X12-CT-A
P2

X11X12-89AT

X11X12-89ATE

P1
X11-CT-A
P2

X11-89AB

X11-89AC

X11-CVT

NEW LINE FEEDER

4CP1

TO
SH.010

09

X03

FM SH.007

03
10

X03

04

J5
J6

13

X03

FM SH.007

13

14

X03

14

J15
J16

TO MAIN PROTN
CIRCUIT
SH.010

CB TC-I &
CLOSING CIRCUIT
SH.035

TO BACKUP PROTN
CIRCUIT
SH.032

CB TC-2 &
CLOSING CIRCUIT
SH.036

DIRECT TRIP RECEIVED CH-1

LBB PROTN.

OVER VOLTAGE PROTECTION

DISTANCE PROTECTION(MAIN-2)

DISTANCE PROTECTION(MAIN-1)

RXMS

RXMS

RAICA

REL670

7SA522

REL670

A/B

DIRECT TRIP RECEIVED CH-2

RXMS+RXME

1 TRIP RELAY OPTD

RXMVB4
A/B

3 TRIP RELAY OPTD

INITIATE GR-A 1 TRIPPING (RXMS+RXME)


INITIATE GR-B 1 TRIPPING (RXMS+RXME)
INITIATE GR-A 3 TRIPPING (RXMVB4)
INITIATE GR-B 3 TRIPPING (RXMVB4)
INITIATE BREAKER X-1 TC-1
INITIATE BREAKER X-1 TC-2
INITIATE GR-A 1 TRIPPING (RXMS+RXME) TIE
INITIATE GR-B 1 TRIPPING (RXMS+RXME) TIE
INITIATE GR-A MASTER TRIP RELAY(TIE)
INITIATE GR-B MASTER TRIP RELAY(TIE)
LBB INITIATION
BUSBAR INITIATION
START AUTORECLOSER
BLOCK AUTORECLOSER
ALARM
DISTURBANCE RECORDER

FROM CT
CORE-1
SH.003

IR1
IY1
IB1
IN1

FROM BUS-1
CVT SUPPLY

FROM LINE
CVT SUPPLY
SH.004

4RLA

X01

X02
05
06
X02
01
02
03
04

01
02
03
04
05
06
07
08

A10
A30
A50
A70

E11
E71

E111
E131
E151
E171

TO SH.022

TO SH.043

FS09

2A

2A
FS10

FS11
2A
FS12
2A
FS13
2A
LK13

E12
E72

E112
E132
E152
E172

R04.101.101

1B

RTXP18 1MYN565010-A

1A

2B

4B

3B

2A
3A
4A
5A

5B

] TO SH.010

A11
A31
A51
A71

13A

12A

11A

10A

9A

8A

7A

14B

13B

12B

11B

10B

9B

8B

7B

6B

14A

15B

6A

15A

16B
] TO SH.011

E113
E133
E153
E173

TO SH.010

16A

17B

] TO SH.010

E13

17A

18B

E73

18A

4RLA

A11

A31

A51

A71

R01
REL670

X401
1

2
3

4
5

6
8

7
9

10
11

TRM

ADM

+
INTERNAL FAIL

PSM

NUMERICAL LINE TERMINAL

A101(I)

A012(I)

A103(I)

A104(I)

A105(I)

A106(I)

A107(U)

21

X11
4
5

X11
2
3

X301
(A)TX
(B)RX

K101A
K102A

L103B
L121

R04.101.101

1A

18B

1B

RTXP18 1MYN565010-A

18A

TO ANNUN.
SH.039

19" x 3/4

K101
K102

FM SH.008

REAR VIEW

TO SH.011

X301
A
B

X401

12
13

A108(U)

P30:1
IEC61850
ST CONNECTOR
(REAR)

X61

14

A109(U)

P30
HMI
(FRONT)
RJ45 CONNECTOR
A110(U)

X62

X401 - TRANSFORMER MODULE - TRM


X11 - POWER SUPPLY - PSM
X31,X32 - BINARY I/O MODULE - IOM
X41,X42 - BINARY I/O MODULE - IOM
X51,X52 - BINARY I/O MODULE - IOM
(THE ABOVE TO BE MODIFIED AS PER ORDERING)

X31
X41
X51

15

16
17

18
19

A111(U)

A112(U)

X11

E113

E133

E153

E173
E13

E73

20
21

22
23

24

X32
X42
X52

FROM SH:009
FROM SH:009

PLCC
(+Ve)
CODE-A
CARRIER SEND (CH-1)

(+Ve)
CODE-A
CARRIER SEND (CH-2)

CODE-A

CODE-A

4CP1
YN1M301134-CAA
T N C

SH.016

4RLA

X04

K141
K143

K16A
K143A

FM SH:010

K103A
1P3

1P1

R02
IN

OUT
1P4

10

X04

13

X04

1P2

R04.101.101

12

17B

K103

K104

K105

K106

K107

K108

K109

K110

R04.137.307
RXSF

RTXP18 1MYN565010-A
17A

11

62

X04

SH.009

61

64

X04

63

K111

24
26

22

28

21

25

23

27

R01
REL670

NUMERICAL LINE TERMINAL

BINARY I/O MODULE - 1

21

OPTO COUPLER INPUTS


CARRIER RECEIVED
BI.01

X31
1

CARRIER OUT/
BI.02 CARRIER FAIL

X31

15

13

11

18

16

14

12

K102AC

K102AD

K102AF

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

16

14

12

10

BI.05
SPARE
BI.06
SPARE
BI.07
SPARE
BI.08

17

R04.137.307
RXSF

TEST MODE

SOTF INITIATION
BI.04

SPARE
BI.03
5

11

13

15

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

FM SH:010

01

XX1

02

04

TO SH:015

K102

X04

X04
06

TO SH:015

K101

01
02

15
14

X04
03
04

09

X04

22
07

05

23

FM SH.018 FM SH.012

4RLA

K141
2P3

IN

R02

17

X04

91

X04

OUT
2P4

K145

K611

K142

REL670

R01

X32
1

10

15

17

NUMERICAL LINE TERMINAL


BINARY OUTPUTS
SPARE

BO.01
SPARE

BO.02
SPARE

BO.03
SPARE

BO.04
SPARE

BO.05

CB CLOSE COMMAND (MAIN)

BO.06

SPARE

BO.07
SPARE

SPARE

BO.08
BO.09

SPARE

SPARE

BO.10

BO.11

BO.12

X32
2

8
9

11

12

13

14

16

18

K146

K147

K148

K149

K150
K8B

K18B

K151

K152

K612

K143

16

X04

25

18

19

20

23

X04

24

92

TO MAIN CB
CLOSING
SH.037

K723
K725

X04

TO SH.011

21

X04

22

BBP

4RLB

7SA522

R01

115

P15 SH.027

R05.119.319

14
15
SH.033

X11-AAC

X11-52-CB (MAIN)
63AR

116

P16

ABB DRG. 1HYB901577-2

131

4RLA
FM SH.011

K101

REL670

R01

BI.01
DIRECT TRIP CH-1 REC.

BI.02
DIRECT TRIP CH-2 REC.

BI.03
MAIN-II
PROTECTION OPTD

BI.04
CB READY STATUS/
CB POLE DISC.

BI.05
LINE ISOLATOR OPEN
(INITIATE STUB PROTN.)

BI.06

BI.07

BI.08

15

13

11

18

16

14

12

] TO MAIN-2 A/R SH.026

] TO MAIN-1 A/R SH.015

R06.119.101
RXSF

17

16

14

12

10

X41

NUMERICAL LINE TERMINAL

OPTO COUPLER INPUTS

BINARY I/O MODULE - 2

11

13

15

BUSBAR TRIP OPTD

01

K124

X41

X09

K119

K122

K121

K120

01

R05.119.319

14
15
SH.020

R06.119.101

23
24
SH.038

K125

K123

26
K126

X04

28

X04

31

27

K326

X04

X04

13
14
SH.015
R04.137.301

X19

02

X14

02

X14
03

88

87

X04

30

29

X04

05

04

03

04

05

132

TO SH.017

K102BC

K102BD

K102BE

K102BF

K102

FM SH.011

09

XX1

10

11

12

TO SH.017

4RLA

101

X04

L103

REL670

R01

X42
1

10

15

17

NUMERICAL LINE TERMINAL


BINARY OUTPUTS
R-PH TRIP OPTD (MAIN)

BO.01
Y-PH TRIP OPTD (MAIN)

BO.02
B-PH TRIP OPTD (MAIN)

BO.03
SPARE

BO.04
SPARE

BO.05

BO.06

R-PH TRIP OPTD (TIE)

BO.07
Y-PH TRIP OPTD (TIE)

B-PH TRIP OPTD (TIE)

BO.08
BO.09
SPARE

BO.10
PSB DE BLOCKING(TRIP)

BO.11
SPARE

BO.12

X42

8
9

11

12

13

14

16

18

K101

K151

K152

K153

K153A

K153B
K101

K165
K101
RK151

RK152

RK153

37

K153C X04

L128

TO INITIATE
MAIN 1 TRIP
SH.019

31

X04

32

TO INITIATE
MAIN 3 TRIP
SH.020

TO ANN.
SH.039

SH.12.1

TO INITIATE
TIE 1 TRIP-A

X11X12-TIE PROTN PANEL

46

47

X04

34

48

33

35

49

X04

36

102

X04

X11-52CB (MAIN)

B-Ph

Y-Ph

R-Ph

1HYB901577-3

337

385

439

338

386

440

4RLA

K101

FM SH.015

37

X04

38

39

40

TO SH.018.1

41

X04

42

X04

44

X04
43

46

X04

X04

45

48

X04

X04

47

X04

K128

K129

K130

K131

K132

K133

K134

R01
REL670

X51
1

11

13

15

16

14

12

10

X51

NUMERICAL LINE TERMINAL

OPTO COUPLER INPUTS

BINARY I/O MODULE - 3


SPARE
BI.01
X11-52-CB R-Ph
(MAIN CB)

BI.02
X11-52-CB Y-Ph
(MAIN CB)

BI.03
X11-52-CB B-Ph
(MAIN CB)

BI.04
SPARE
(TIE CB)

BI.05
SPARE
(TIE CB)

BI.06
SPARE
(TIE CB)

BI.07
SPARE
BI.08

K102BH

K102BJ

K102BK

K102

FM SH.015

XX1
13

14

15

16

TO SH.018.1

4RLA

K16A
3P3

R02
IN

18

XX1

OUT
3P4

K15A

R01

X52
1

10

15

17

BINARY OUTPUTS
DISTANCE PROTN. OPTD.

BO.01
STUB PROTN, OPTD.

O/V OPTD

BO.02

BO.03
O/C & E/F OPTD

BO.04
PSB OPTD.

BO.05

BO.06
VT FUSE FAIL OPTD.

BO.07
A/R OPTD.

SPARE

BO.08
BO.09
SPARE

BO.10
MAIN-I PROTECTION OPTD

BO.11

BO.12

X52
2

8
9
11

12

13

14

16

18

K101

K142

K143

K144

K145

K146
K101

K165
K147

K148

51

K149A X04

K201
K218
K143A

TO SH.018.1

TO SH.018.1

TO SH.011

TO SH.018.2

X04
49

50

X14
08
09

X04

TO INITIATE
TIE 3 TRIP-A
SH.014

X11X12-TIE PROTN PANEL

93

94

TO MAIN-II PROTN.
FOR DR SH.026

4RLA

FM SH.018

16

14

DISTANCE PROTN. OPTD.

21

] TO DAS SH.040

] TO ANNUN. SH.039

R04.125.101
RXSF
12

11
13
15

13
16

14

23

28

26

24

23
25
27

24
26
28

PSB OPTD.

K102

FM SH.017

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

K101

FM SH.018.1

K102

FM SH.018.1

26 SH.035 27

13

18

16

14

R05.143.101
R05.143.107

R05.143.113

15

16

26

TB4

13

1X04

4CP1

K150

TB4

19

14

01

K152

20

YN1M301134-CAA,SH.017

03

TO SH.018.2

KU3

02

KU1

] TO SOE SH.041

] TO DAS SH.040

R06.101.101
TC-1 FAULTY
K151A
RXSF
11
12
] TO ANNUN. SH.039

26 SH.035 27

17

11

15

18

13

17

14

R06.101.301
RXSF
12

26 SH.035 27

R05.143.301

28

04

] TO SOE SH.041

] TO DAS SH.040

R06.101.101
K152A
TC-2 FAULTY
RXSF
22
] TO ANNUN. SH.039
21

24

26 SH.036 27

26

R05.143.307

23

28

] TO ANNUN. SH.039

25

R05.143.313

27

21

25

23

27

24

R06.101.301
RXSF
22

26 SH.036
SH.035 27

26 SH.036 27

] TO SOE SH.041

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

R04.125.307
RXSF
12

11

16

14

15

18

13

17

A/R OPTD.

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

TO SH.018.1

TO SH.018.2

] TO DAS SH.040

R04.125.301
RXSF
12

15
18

25

R04.125.307
RXSF
22

27

21

VT FUSE FAIL OPTD.

17

11

] TO SOE SH.041
17
18
R04.125.101
RXSF
STUB PROTN, OPTD.
22

K101

FM SH.017

K142

K143

K146

K147

K148

TO SH.018.1

4RLA

FM SH.018

24

O/C & E/F OPTD

O/V OPTD

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

FM SH.018.1

14

FM SH.018.1

16

K102

13

18

R04.125.107
RXSF
12

15

11

17

23
26
] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

R04.125.107
RXSF
22

25
28

21

27

TO SH.019

K101
K145

K144

TO SH.019

4RLA

MAIN-I 1
PROTN TRIP
SH.016

FM SH.018.2
K101

TO SH.020
K151

K152

K153

27

17

21

R05.101.101
11

16

26

15

13

21

R05.101.301
11

12

14

22

27

25

23

17

24

16

26

26

16

11

27

17

21

R05.101.107

] TO DAS SH.040
] TO SOE SH.041

13

21

R05.101.307
11

12

22

16

27

25

23

17

15

24

14

26

27

17

21

R05.101.113
11

16

26

] TO DAS SH.040
] TO SOE SH.041

13

21

R05.101.313
11

12

22

16

27

25

23

17

15

24

14

26

K3

K5

K7

K9

K53

K55

K57

K59

K201

K284

K285

K286

] TO DAS SH.040

] TO SOE SH.041

FM SH.018.2

K102

TO SH.020

TO TRIP COIL-1

SH.035

TO TRIP COIL-2

SH.036

TO LBB INITIATION

SH.021_3

4RLB

RAICA

R03.101
101
:17A

SH.021_2
331
:16

X11X12-TIE PANEL
LBB OPTD.
FM SH 12.3

PLCC
DIRECT TRIP CODE-C
RECEIVE CH-1

4RT
TO INITIATE GR-A
3 TRIP SH.014

4RLA

01

X14

K101

FM SH.019

01

02

X14

02

PB UNIT

R05.119.119

16

26

K161
R01
REL670

SH.016

X42
8
R05.119.319

X42
7

12

13

58

X04

K166

K165

] TO DAS SH.040

K168

24

22

16

14

12

27

25

23

17

15

13

] TO SOE SH.041

] TO DAS SH.040

X04 U152
55

] TO ANNUN. SH.039

] TO SH.015

] TO SH.020

R05.119.319
RXMS
21

26

11

] TO ANNUN. SH.039

SH.020

31

59

X04

32

X04
60
61

53

X04

93

54

X04

94

TO SH.038

] TO ANNUN. SH.039

56

U153 X04

] TO CLOSE COIL INTERLOCK SH.037

] TO DAS SH.040

] TO SOE SH.041

] TO DIRECT TRIP SEND SH.021

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-2 SH.036

] TO MAIN CB TC-2 SH.036

] TO MAIN CB TC-2 SH.036

] TO LBB INITIATION SH.021_3

FM SH.019

K102

TO SH.038

PLCC

DIRECT TRIP SEND CH-1


CODE-C

4RLA
X04
93

94

1X04
24

1X04
32
1X04
21

K611

K612

BBP

R05.119.101
225
226
SH.020

33

X04

25

X04

329

330 317

330 317

ABB DWG 1HYB901577-3


R
Y

X11-52 MAIN CB

329

ABB DWG 1HYB901577-3


R
Y

4CP1 X11X12-52 TIE CB

X11X12-TIE PANEL

N C

N C

MAIN CB
SH 16
T

7P4

7P4

X04 R05.101.307 X04


27 12
13 28
SH.012.3

7P3

7P3
TIE CB
SH 23

YN1M301134-CAA

318

318

431

431

432

432

22

X14

22

21
X14

X14

23

X14

21
X14

23

24

X14

X14

24

25

X14

X14

25

X14

4RLB

FM SH.021.2 [

K292

27

25

23

17

15

13

21

R04.155.301
11

12

14

16

22

24

26

K620

K619

K618

K617

K616

K615

K614

K613

K612

K611

P41H

P31

K202

FM SH.021.2
K201

TO SH.023

X09
09
10

85

94

93

YN1M301134-CAG

TO GR-B TRIP
RELAY
SH 014.1

TO GR-A TRIP
RELAY
SH 014

TO INITIATE
BUSBAR
TRIP

BUSBAR PANEL-BB1

86

83

X04

4RT

87

84

X04

88

89
90
91
92
93
94

FROM TIE CT
CORE-2
SH.005

4RLA

FROM SH.009
BUS-1 CVT
SUPPLY

FROM LINE
CVT SUPPLY
SH.004

TIR2
TIY2
TIB2
TIN2

X12
01
02
VR1
VY1
VB1
VN1

4RLB

X01

X12
01
02
X02
01
02
03
04

11
12
13
14
15
16
17
18

E11

FROM CT
CORE-2
SH.021_1

E71

E211
E231
E251
E271

FS03

2A

2A
FS04

FS05
2A
FS06
2A
FS07
2A
LK07

A13
A33
A53
A73

E12
E72

E212
E232
E252
E272

1B

RTXP181MYN565010-A

R04.101.101

1A

7B

6B

5B

4B

3B

2B

E16

2A

3A
4A
5A
6A

7A

] TO SH.023

A14
A34
A54
A74

E13
E73

13A

12A

11A

10A

9A

14B

13B

12B

11B

10B

9B

8B

14A

15B

E76

15A

16B
] TO SH.024

8A

16A

17B

] TO SH.023

E213

17A

18B

E273

E253

E233

18A

TO SH.023

4RLB

FROM SH:022
FROM SH:022

A14

A34

A54

A74

E213

E233

E253

E273

E13

E73

R01
7SA522

Q1

Q2
Q3

Q4
Q5

Q6

R15

R17

R18

R16

R13

R14

K2

K1

21

K4

K3

INTERNAL FAIL

PSM

NUMERICAL LINE TERMINAL

(I)

(I)

(I)

(U)

(U)

(U)

(U)

K201A
K202A

L103
L121

R04.101.101

1A

18B

1B

RTXP18 1MYN565010-A

18A

TO ANNUN.
SH.039

K201

K202

FM SH.021_8

TO SH.024

PLCC

4CP1
N C

09

4RLB
X04

10

11
12

X04
03
04

X04
08

28

X04

07

06

X04

05

29

K241
K243

K245
K247

FM SH:023

K103A
1P3

1P1

R02
IN

OUT
1P4

1P2

SH.022

17B

R04.101.101
RTXP18 1MYN565010-A
17A

61

X04

63

X04

60

62

K209

25

23

28

26

24

K203

K204

K205

K206

K207

R01
7SA522

K17

J1

J3

J4

J6

J7

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

K208

R04.155.101
RXSF
22

X04

X04

21

27

NUMERICAL LINE TERMINAL

OPTO COUPLER INPUTS


CARRIER RECEIVED
BI.01
CARRIER OUT/
BI.02 CARRIER FAIL
TEST MODE
BI.03

13

11

18

16

14

12

21

K18

J2

J5

J8

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

SOTF INITIATION
BI.04
SPARE
BI.05
SPARE
BI.06

15

R04.155.101
RXSF

17

FM SH:023

TO SH:026

K202

(+Ve)
CODE-B
CARRIER SEND(CH-2)

T
7P2

(+Ve)
CODE-B
CARRIER SEND(CH-1)

CODE-B

CODE-B

7P1

SH.016

TO SH:026

K201

FM SH.025
FM SH.025

4RLB

K245
3P3

K241
2P3

R02
IN

R02
IN

OUT

15

K246

L103

K242

X04 K345

3P4

OUT
2P4

7SA522

R01

K5

K9

P5

K11

K13

NUMERICAL LINE TERMINAL


BINARY OUTPUTS
BO.01
SPARE

BO.02
SPARE

BO.03

CB CLOSE COMMAND (MAIN)

BO.04
PSB DE BLOCKING (TRIP)

BO.17
SPARE

BO.18
SPARE

BO.19

SPARE

BO.05

BO.06

K6

K7

K8

K10

P6

P7

P8

K12

K14

K247

14

TO SH.024

09
10

TO MAIN CB
CLOSING
SH.037

TO ANN. SH.039

X14

K343 X04
13
K344

K1
K18B

L128

16

TO SH.024

K346 X04

K243

4RLA

R04.137.301

R06.119.101

16

X52

15
16
SH.015

25
26
SH.038

X11-89AC

4RLA
R01

SH.018

REL670
X52
15

11

X14

K201

FM SH.025

4RLB

10

12

X14

11

17

19

X04

20

X04

X04

18
21
22
23
24
25
26
27

06

X14

28

06

07

X14

07

TO SH.028

K211

K212

K213

K214

K215

K216

K217

K218

7SA522

R01.01

J9

J11

P17

N1

N3

N4

N6

N7

N8

N5

N2

P18

J12

J10

NUMERICAL LINE TERMINAL

OPTO COUPLER INPUTS


CB READY STATUS/
CB POLE DISC.

BI.07
LINE ISOLATOR OPEN
(INITIATE STUB PROTN.)

BI.08
SPARE

BI.09
SPARE

BI.10

BI.11

SPARE

BI.12

BI.13
MAIN-I
PROTECTION OPTD

BI.14

FM SH.025

K202

TO SH.028

4RLB

X04K241A
37

RK58

RK56

K723

X04 K723A
39

X04
31

33

35

7SA522

R01

P9

P11

R7

K15

R9

R11

P15

NUMERICAL LINE TERMINAL

SPARE

BINARY OUTPUTS
SPARE

BO.20

SPARE

BO.21

BO.13

BO.07

SPARE

BO.14
SPARE

BO.15

MAIN-II PROTECTION OPTD

BO.23

P10

P12

R8

K16

R10

R12

P16

K249A X04
38

36

34

32

X04

40

K725A X04

K201

K265

K725

RK57

RK59

K101

K118

X04

TIE 3 TRIP-B
SH.014

TO INITIATE

X11X12-TIE PROTN PANEL


X04

81

82

TO MAIN-I PROTN.
FOR DR SH.015

29

30

X14
31

32

B-Ph

Y-Ph

1HYB901577-3
R-Ph

X11-52CB (MAIN)

103
233
283

104
234
284

4RLB

38

X04

39

40
37

FM SH.026

K201

TO SH.031.1

R04.113.101

43

X04

41

X04

46

X04

44

X04

42

X04

423
424
SH.044

45

48

X04

X04

47

50

X04

X04

49

52

X04

X04

51

X04

K219

K220

K221

K222

K223

K224

K225

K226

K227

K228

7SA522

R01

N9

N11

H17

G1

G3

G4

G6

G7

G9

G11

G12

G10

G8

G5

G2

H18

N12

N10

NUMERICAL LINE TERMINAL

OPTO COUPLER INPUTS


BUSBAR TRIP OPTD

BI.15
CB X11-52B-RPh
(MAIN CB)

BI.16
CB X11-52B-YPh
(MAIN CB)

BI.17
CB X11-52B-BPh
(MAIN CB)

BI.18
SPARE

SPARE

BI.19

SPARE

BI.20

BI.21
SPARE

BI.22
SPARE

BI.23
SPARE

BI.24

FM SH.026

K202

TO SH.031.1

4RLB

7SA522

R01

H5

H3

H9

H11

H13

NUMERICAL LINE TERMINAL


BINARY OUTPUTS
R-PH TRIP OPTD (MAIN)

BO.25
Y-PH TRIP OPTD (MAIN)

BO.26
B-PH TRIP OPTD (MAIN)

BO.27
INITIATE MAIN 3 TRIP

BO.24

R-PH TRIP OPTD (TIE)

BO.28
Y-PH TRIP OPTD (TIE)

BO.29
B-PH TRIP OPTD (TIE)

BO.30

H6

H7

H8

H4

H10

H12

H14

K201

K251

K252

K253
K201
K265
K201
RK251

RK252

RK253

TO INITIATE
MAIN 1 TRIP
SH.032

sh 12.2

TO INITIATE
TIE 1 TRIP-B

X11X12-TIE PROTN PANEL

50

X04

TO INITIATE
MAIN 3 TRIP
SH.033

53

X04

52

51

56

53

54

57

4RLB

R01

R5

H15

P3

BINARY OUTPUTS
DISTANCE PROTN. OPTD.

BO.08
STUB PROTN, OPTD.

BO.09
O/C & E/F OPTD

BO.10
O/V OPTD

BO.11
PSB OPTD.

BO.12
VT FUSE FAIL OPTD.

BO.31
A/R OPTD.

BO.24

R1

R2

R3

R4

R6

H16

P4

K201

K242

K243

K249

K245

K246

K247

K265A

TO ANNUN.
SH.031.1

4RLB

FM SH.031

FM SH.021_2

FM SH.031

12

23

21

28

26

24

22

16

14

26

24

13

18

16

14

DISTANCE PROTN. OPTD.

13

11

18

16

14

12

24

22

VT FUSE FAIL OPTD.

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

O/C & E/F OPTD.

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

A/R OPTD.

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

R04.143.307
RXSF

15

21

26

22

K201

FM SH.031.1

K247

17

23

28

R04.143.307
RXSF

25

21

24

FM SH.031

K265A

27

23

26

R04.143.301
RXSF

] TO ANNUN. SH.039

25

K249

] TO DAS SH.040

28
TOSH.032

27

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

PSB OPTD.

] TO DAS SH.040
] TO SOE SH.041

TO SH.031.1

OVER VLOTAGE PROTN. OPTD.

] TO SOE SH.041

LBB PROTN. OPTD.

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

STUB PROTN, OPTD.

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

FM SH.028

14

FM SH.028

11

16

K202

13

18

R04.143.101
RXSF

15

25

13

18

R04.143.107
RXSF
12

15

23

28

R04.143.107
RXSF
22

25

15

11

17

] TO ANNUN. SH.039

R04.143.301
RXSF
12

27

21

17

11

27

R04.143.101
RXSF

17

K201
K242

K243

K244

K245

K246

TO SH.031.1

FM SH.031.1

K202

TOSH.032

4RLB

MAIN-II 1
PROTN TRIP
SH.029

K201

FM SH.031.1

K251

TO SH.033

K252

K253

27

17

21

R05.101.101
11

16

26

15

13

21

R05.101.301
11

12

14

22

27

25

23

17

24

16

26

] TO DAS SH.040
] TO SOE SH.041

11

27

17

21

R05.101.107

16

26

13

21

R05.101.307
11

12

22

16

27

25

23

17

15

24

14

26

27

17

21

R05.101.113
11

16

26

] TO DAS SH.040
] TO SOE SH.041

13

21

R05.101.313

11

12

22

16

27

25

23

17

15

24

14

26

K3

K5

K7

K9

K53

K55

K57

K59

K201

K284

K285

K286

] TO DAS SH.040

] TO SOE SH.041

FM SH.031.1

K202

TO SH.033

TO TRIP COIL-1

SH.035

TO TRIP COIL-2

SH.036

TO LBB INITIATION

SH.021_3

4RT
TO INITIATE GR-B
3 TRIP SH.014.1

4RLB

R01
7SA522
P3
SH.029

LBB OPTD.
SH.012.3

X11X12-TIE PANEL

PLCC
DIRECT TRIP CODE-D
RECEIVE CH-2

71

X04
83

72

X04

84

P4

K201

K265

FM SH.032

K201

R05.119.119
PB UNIT

16

RAICA

R03.101
101
:16A

26

K261

SH.021_2
331
:26
R05.119.319
13

12

26

24

22

16

14

12

11

27

25

23

17

15

13

21

K265

] TO SOE SH.041

] TO DAS SH.040

] TO ANNUN. SH.039

] TO SH.015

] TO SH.033

R05.119.319
RXMS

] TO DAS SH.040

] TO ANNUN. SH.039

SH.033

X04

67

66

X04

65

64

34

X04

K266

33

K168

X04 U158
58

] TO ANNUN. SH.039

59

U159 X04

K202

FM SH.032

] TO CLOSE COIL INTERLOCK SH.037

] TO DAS SH.040

] TO SOE SH.041

] TO DIRECT TRIP SEND SH.034

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-1 SH.035

] TO MAIN CB TC-2 SH.036

] TO MAIN CB TC-2 SH.036

] TO MAIN CB TC-2 SH.036

] TO LBB INITIATION SH.021_3

PLCC

DIRECT TRIP SEND CH-2


CODE-D

4RLA

4RLB

64

X04

65
X14

X14

31

31

N C

N C

MAIN CB
SH.016
T

TIE CB
SH.023

35

X04

27

X04

179

X14

X14

32

32

180 229

180 229

ABB DWG 1HYB901577-3


R
Y

X11-52 MAIN CB

179

ABB DWG 1HYB901577-3


R
Y

4CP1 X11X12-52 TIE CB

X11X12-TIE PANEL

226

8P4

8P4

SH.033

R05.119.101
225

R05.101.307
X04
X04

8P3

8P3

29 SH.012.3 30

K614

K613

BBP

X04
26

X04
34
X04

YN1M301134-CAA

230

230

279

279

280

280

BBP

4CP1

313
315
317

B/B TRIP

314
316

1P4

318

1P3
2P4

N C

2P3
3P4

3P3
YN1M301134-CAB, SH 016

4RLB

GR-B
1 TRIPPING
SH.032

313
316

314

R05.119.101
315
318
SH:033

317

4RLA
04

X09

05

04
05
06

X19

06

07

06

CBX04

03

02

01

KX04

07

08
04

07

09

14

X14

15

X14

14

16

13

15

13

16

(220V)
(110V)

(POST CL)
(PRE CL)

27

17
25

21
13
15

R05.143.101
195R
TSR IN7405-3001-A
11
12
16
26

(220V)
(110V)

(POST CL)
(PRE CL)

GR-A
1 TRIPPING
SH.019

SH:020

26

16

11
12

(220V)
(110V)

(POST CL)
(PRE CL)

27

15
17
25

] TO SH.018.1

] TO SH.037

21
13

R05.143.107
195Y
TSR IN7405-3001-A

314
316
318

R05.119.101
313
315
317

] TO SH.037

] TO SH.037

] TO SH.018.1

15

] TO SH.018.1

21
13

R05.143.113
195B
TSR IN7405-3001-A
11
12
16
26

17
25
27

FROM
SH:008

K3

K5

K7

K9

K1A

K2A

03

139

138

142

POST CLOSE
PRE CLOSE
SUPERVISION
CIRCUIT

220V DC
SUPPLY-1

TO TC-1 CIRCUIT

X11-52 BREAKER

04

140

CBX04

05

251
271

201
221

151
171

102

101

06

12

11

10

09

08

07

02

01

TO SH.037

K11
K11A

K13

K13A

K15
K15A

CGL DRG. EH3-2259-22

BBP

4CP1

311
425
427

428

426

312

B/B TRIP

SH:044

6P4

N C

7P4

T
6P3

8P4

7P3
8P3
YN1M301134-CAB, SH 016

4RLB

GR-B
1 TRIPPING
SH.032

311
426

312

R05.119.101

425
428
SH:033

427

08

X09

4RLA
08
09

X19

09
10
11

10
11

05

KX04

06

10

07

CBX04

11

08

12
13

18

17

19

X14

18

20

17

19

X14

20

(110V)

(220V)

(PRE CL)

(POST CL)

(220V)

(PRE CL)

(POST CL)

GR-A
1 TRIPPING
SH.019

312
426

R05.119.101
311
425

428

] TO SH.037

SH:020

21
13
15

] TO SH.018.1

15

] TO SH.018.1

] TO SH.037

21
13
17
25
27

26

16

11
12

(110V)

(220V)

(PRE CL)

(POST CL)

27

15
17
25

] TO SH.018.1

] TO SH.037

21
13

R05.143.307
295Y
TSR
IN7405-3001-A

427

17
25
27

R05.143.301
295R
TSR IN7405-3001-A
11
12
16
26

(110V)

R05.143.313
295B
TSR IN7405-3001-A
11
12
16
26

FROM
SH:008

K53

K55

K57

K59

K51

K52

K51
K51A

K53
K53A

K55
K55A

13

CBX04

14

15

155
175

POST CLOSE &


PRE CLOSE
SUPERVISION

220V DC
SUPPLY-2

TO TC-2 CIRCUIT

BREAKER 52

143

144

145

146

104

21
22

205
225

105

23
24

255
275

16

17

18

25
26

118

MANUAL
CLOSE

YN1M301134-CAA, SH 016

BBP

117

4RLA

09

CBX04 KX04
04
10

X19
12

X09

05

12
13

K21

13

K23

SH.035

16

R05.143.101
15

27

16

R05.143.301
15
SH.036

X14

4RLB
X14
27

R05.143.113
16

R05.143.107

15
SH.036

16

R05.143.313

SH.035

15

16

15
16
SH.035
R05.143.307
15
SH.036

R01
REL670
X32
07
SH.012

SH.025

R01
7SA522
K9

X32
09

K23A

K10

118

28

SH:020

R05.119.101
117

X14

X14
28

K25

X14

X14

29

K8B

K18B

SH:033

118

29 R05.119.101
117

30

30

X11-52 BREAKER

AUTO RECLOSING

MANUAL
CLOSING

CLOSING
INTERLOCK

ABB DRG: 1HYB901577-3

115

137

117

27

136

136

137

28

24

23

KX04

K27

CBXO4

FM SH.035

K1A

X14

X14

BREAKER MB

SF6 GAS REPLENISHMENT ALARM

128

14

12

24

22

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

] TO ANNUN. SH.039
] TO DAS SH.040
] TO SOE SH.041

] TO DAS SH.040
] TO SOE SH.041

] TO DAS SH.040

TO SH.043

] TO A/R L/O MAIN-2, SH.026

] TO A/R L/O MAIN-1, SH.015

R04.137.301
RXSF
22

24

21

23

26

FM SH.020

11

16

21

26

14

24

] TO SOE SH.041

] TO DAS SH.040

28

FM SH.020

13

18

R04.137.101
RXSF

15

23

28

16

26

14

] TO SOE SH.041

25

K102

K171

17

25

R04.137.101
RXSF

27

13

18

R04.137.107
RXSF
12
] TO ANNUN. SH.039
15

11

17

23

28

] TO ANNUN. SH.039

R04.137.107
RXSF
22

25

21

27

13

16

] TO ANNUN. SH.039

R04.137.301
RXSF
12

15

18

11

17

27

K101

4RLA

66

X04
423
67

K172

K173

K174

K175

TO SH.043

75

74

X04

73

72

X04

71

70

X04

69

68

X04

426

CB LOW AIR PRESSURE ALARM


126

CB POLE DISC.

CB OPERATION LOCKOUT

CB LOW OIL LEVEL ALARM

ABB DWG : 1HYB901577-3

4RLA

SH.018.1

24

R04.125.101
23

24

XX1 L103B

18

14

14

R04.125.101
13
SH.018.1

SH.020

SH.018.1

23

14

24

R04.137.101

13

R06.101.101

22

R05.119.319

L103
L105
L107

L158

L155

L153

L151

L149

L147

L160

L159

L135

L133

L129

R04.125.107
L111
23
24
R04.125.301
SH.018.2
L113
13
14
R04.125.307
SH.018.1
L115
13
14
R04.125.307
SH.018.1
L117
23
24
R04.137.307
SH.018.1
L119
13
14
R01
SH:010
SH.011
REL670
XX1 L103B
X11
X11
L121
02
03
17
R06.155.101
L123
17
18
R06.155.101
SH.007
L125
27 SH.007 28
R06.125.101
L125A
115
116
R04.125.107
SH.006
L127
R0113 SH.018.2 14
REL670
SH:016
X42 B0.11 X42
L128
15
16
24

R04.137.307

23
SH.011

R05.119.101
113
114
SH.020

SH.018.1

R06.101.101
23

SH.038

R04.137.101
13

23

SH.038

24

R04.137.107

23

R04.137.107

14

SH.038

13 SH.038 14
R05.119.313
16 SH.020 17

SH.038

R04.137.301
13

02

1X05
01

4CP1
X05
01

03

02
03
04
05

07

06

08

06

07

06

08
09

10

09

10
11

15

14

13

11
12
32
06

14
15

18

17

16

17

16

18

23

24

23

19

24

25

29

27

26

25
26
27

29

+VE
MAIN-I/II DISTANCE PROTN. OPTD.

LBB PROTN. OPTD.

MAIN-I/II STUB PROTN. OPTD.

OVER VOLTAGE PROTN. OPTD.


MAIN-I/II PSB OPTD.
MAIN-I/II VT FUSE FAIL
MAIN-I/II A/R OPTD.
CARRIER RECEIVED MAIN-1/2

MAIN-I/II PROTN. RELAY IN OPERATIVE


DC SOURCE-1/2 FAIL/AC SUPPLY FAIL

O/C & E/F OPTD.

MAIN-I/II POWER SWING DE BLOCKING OPTD.


MAIN-I/II CARRIER FAIL
DIRECT TRIP RECEIVED CH-1/2

CB TC-1/2 FAULTY

A/R LOCKOUT OPTD.

CB LOW AIR PRESSURE ALARM

CB SF6 GAS REPLENISHMENT ALARM

CB POLE DISC. TRIP


CB OPERATION LOCKOUT
TRIP RELAY GR-A/B FAULTY

CB LOW OIL LEVEL ALARM

4RLB

L157

L129

L128

L127

L121

L119

L117

L115

L113

L111

L109

L107

X05
L103
01
L105
02
03
04
05
06
07
08
09

10

13

14
15
16

17

18

14

R04.143.101
13

SH.031.1

14

R04.143.107
13

SH.031.1

14

R04.143.301
13

SH.031.1

23

P5

R01
7SA522

R03

K3

R01
7SA522

24

R04.143.307
23

SH.031.1

SH:023

K4

SH:025

P6

SH.033

R05.119.319
22

L103

L103

SH.031.1

24

R04.143.101

23

SH.031.1

24

R04.143.107

23

SH.031.1

14

R04.143.307

13

SH.024

13

R04.155.101

14

R04.143.301

14
13
SH.031.1

SH.024

23

R04.155.101

24

R05.119.101

113
114
SH.033

R05.119.313

16 SH.033 17

4RLA

S147

S143

S147

S143

S141

15

24

24

26

25

25

SH.011

SH.019

SH.020

SH.018.1

SH.038

SH.038

16

25

25

25

26

26

R06.125.101
117
118
SH.006

25
SH.018.1

SH.018.1

15

26

26

16

27

SH.018.2

16

R04.125.107

SH.020

R05.119.313

15

S139 R04.125.307

S137

S131 R04.125.101

S129

S127

S125

S123 R04.137.107

S121

S119 R04.137.101

S117

S115 R06.101.101

S113

S111

S109 R05.119.319

S107

S105 R05.101.307

S103

X06 S101 R04.137.307


01
03
05
07
09
11

13
15
17
19
21
23
25
27
29
31
37
39
41
43
47
49
51

SH.019

25

R05.101.301
24

SH.019

25

R05.101.313
24
R05.119.101

SH.018.1

15

221
222
SH.020
R06.101.101
16

16

R04.137.101
15
SH.038

SH.038

16

R04.137.107
15

SH.038

16

R04.137.301
15

16

R04.125.101
15
SH.018.1

SH.018.1

16

R04.125.301
15

SH.018.1

26

R04.125.307
25

SH.011

16

R04.137.307
15

SH.018.2

26

R04.125.107
25

S102
S104
S106
S108
S110
S112

S114
S116
S118
S120
S122
S124
S126
S128
S130
S132
S138
S140
S142
S144
S148
S150
S152

X06
02
04
06
08
10
12

14
16
18
20
22
24
26
28
X06
30
32
38
40
42
44
48
50
52

DAS PANEL

CARRIER RECEIVED CH-1


GR-A R-PH TRIP OPTD.
GR-A Y-PH TRIP OPTD.
GR-A B-PH TRIP OPTD.
DIRECT TRIP RECEIVED CH-1
GR-A 3 TRIP RELAY OPTD.

TC-1 FAULTY
TC-2 FAULTY
CB SF6 GAS REPLENISHMENT ALARM
CB LOW AIR PRESSURE ALARM
CB POLE DISC.
CB OPERATION LOCKOUT
CB LOW OIL LEVEL ALARM
AC SUPPLY FAIL
DISTANCE PROTN. OPTD.
STUB PROTN, OPTD.
PSB OPTD.
VT FUSE FAIL OPTD.
A/R OPTD.
GR-A 3 TRIP RELAY FAULTY
CARRIER FAIL
O/C & E/F OPTD
O/V OPTD

4RLB

S131

S129

S127

S125

S123

S121

S119

S117

S115

S113

S111

S109

S107

S105

S103

X06 S101
01
03
05
07
09
11
13
15
17
19

21
23
25
27
29
31

SH.024

26

16

R04.155.101
15

SH.031.1

R04.143.101
25

SH.031.1

26

R04.143.107
25

SH.031.1

16

R04.143.307
15

16

R04.143.301
15

SH.031.1

SH.032

25

R05.101.301
24

R05.101.313
24 SH.032 25

SH.033

25

R05.119.319
24

SH.031.1

16

R04.143.101
15

SH.031.1

16

R04.143.107
15

SH.031.1

16

R04.143.301
15

SH.031.1

26

R04.143.307
25

26

R04.155.101
25
SH.024

SH.032

25

R05.101.307
24

SH.033

27

R05.119.313
26

R05.119.101
221
222
SH.033

S102
S104
S106
S108
S110
S112
S114
S116
S118
S120

S122
S124
S126
S128
S130
S132

X06

02

04

06

08

10

12

14

16

18

20

22

24

26

28

30

32

DAS PANEL

CARRIER RECEIVED CH-2

DISTANCE PROTN. OPTD.

STUB PROTN, OPTD.

LBB PROTN. OPTD.

OVER VLOTAGE PROTN. OPTD.

PSB OPTD.

VT FUSE FAIL OPTD.

A/R OPTD.

O/C & E/F OPTD.

CARRIER FAIL

GR-B R-PH TRIP OPTD.

GR-B Y-PH TRIP OPTD.

GR-B B-PH TRIP OPTD.

GR-B 3 TRIP RELAY FAULTY

DIRECT TRIP RECEIVED CH-1I

GR-B 3 TRIP RELAY OPTD.

4RLA
X07
01
03
05
07
09
11
13

15
17
19
21
23
25
27
29
31
37
39
41

S301
S303
S305
S307
S309
S311
S313

S315
S317
S319
S321
S323
S325
S327
S329
S331
S337
S339
S341

S351

17

SH.011

18

R04.137.307
17

SH.019

27

R05.101.307
26

SH.020

27

R05.119.319
26

R06.125.101

28

28

28

18

18

27

SH.019

27

R05.101.301
26

SH.019

27

R05.101.313
26

R05.119.101
223
224
SH.020

SH.018.1

18

R06.101.101
17

SH.038

18

R04.137.101
17

SH.038

18

R04.137.107
17

SH.038

18

R04.119.319
17

SH.018.1

28

R04.125.101
27

SH.018.1

18

R04.125.307
17

SH.011

28

28

R04.137.307
27

SH.018.2

R04.125.107

225
226
SH.006

SH.018.1

R06.101.101
27

SH.038

R04.137.101
27

SH.038

R04.137.107
27

SH.018.1

R04.125.101
17

SH.018.1

R04.125.301
17

18

28

R04.125.307
27

SH.018.2

SH.018.1
S345
45
R04.125.107
S347
47
49

S302
S304
S306
S308
S310
S312
S314

S316
S318
S320
S322
S324
S326
S328
S330
S332
S338
S340
S342
S346
S349
S353

X07
02
04
06
08
10
12
14

16
18
20
22
24
26
28
30
32
38
40
42
46
48
50

SOE PANEL
CARRIER RECEIVED CH-1
GR-A R-PH TRIP OPTD.
GR-A Y-PH TRIP OPTD.
GR-A B-PH TRIP OPTD.
DIRECT TRIP RECEIVED CH-1
GR-A 3 TRIP RELAY OPTD.
AC SUPPLY FAIL

4RLB
X07
01
03
05
07
09
11

15

13
TC-1 FAULTY

17

29

27

25

23

21

19

TC-2 FAULTY
CB SF6 GAS REPLENISHMENT ALARM
CB LOW AIR PRESSURE ALARM
CB POLE DISC.
CB OPERATION LOCKOUT
CB LOW OIL LEVEL ALARM
DISTANCE PROTN. OPTD.
STUB PROTN, OPTD.
PSB OPTD.
VT FUSE FAIL OPTD.
A/R OPTD.
CARRIER FAIL
O/C & E/F OPTD
O/V OPTD

S301
S303
S305
S307
S309
S311
S313
S315
S317
S319

S321
S323
S325
S327
S329

SH.024

28

18

R04.155.101
17

SH.031.1

R04.143.101
27

SH.031.1

28

R04.143.107
27

SH.031.1

18

R04.143.307
17

18

R04.143.301
17

SH.031.1

SH.032

27

R05.101.301
26

SH.032

27

R05.101.313
26

SH.033

27

R05.119.319
26

SH.031.1

18

R04.143.101
17

SH.031.1

18

R04.143.107
17

SH.031.1

18

R04.143.301
17

SH.031.1

28

R04.143.307
27

28

R04.155.101
27
SH.024

SH.032

27

R05.101.307
26

SH.033

224

R05.119.101
223

S302

S034

S306

S308

S310

S312

S314

S316

S318

S320

S322

S324

S326

S328

S330

X07

02

04

06

08

10

12

14

16

18

20

22

24

26

28

30

DAS PANEL

CARRIER RECEIVED CH-2

DISTANCE PROTN. OPTD.

STUB PROTN, OPTD.

LBB PROTN. OPTD.

OVER VLOTAGE PROTN. OPTD.

PSB OPTD.

VT FUSE FAIL OPTD.

A/R OPTD.

O/C & E/F OPTD.

CARRIER FAIL

GR-B R-PH TRIP OPTD.

GR-B Y-PH TRIP OPTD.

GR-B B-PH TRIP OPTD.

GR-B 3 TRIP RELAY OPTD.

DIRECT TRIP RECEIVED CH-1

4RLA

FROM
SH.009

X04
76

77

FROM
SH.009

E111
E131

K191

K193

E131
E151

R04.149.101

222

27-1

+VE
225

RXEG21
111
-VE
223

221

118

227
226

117
116

1K193

1K191

224

228

27-2

-VE

+VE

225

222

RXEG21
111

117
116

K197

K195

R04.149.301

221

223

118

227

224

228

226

X04
78

79

K102

FM SH.038

TO EARTH SWITCH
INTERLOCK

K101

Вам также может понравиться