Вы находитесь на странице: 1из 13

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client

Number: Contact: P2 [kW] 75 Pump outlet DN 125

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski Q actual [m/h] 686 H actual [m] 62.2 Energy [kWh/a] 323050

Product name 4 x NK 125-400

Phase 3

U [V] 380-415 D / 660-690 Y

p max [bar] 16

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

NK 125-400 -A BAQE Non-self priming, single-stage centrifugal pump according to EN 1092-2. The pump is for the pumping of thin, clean or slightly contaminated liquids without abrasive or long-fibred solids. Pump and 3-phase AC motor are mounted as separate units on a common baseplate and connected via a Spacer-coupling. The impeller is hydraulically as well as dynamically balanced. The pump has the following characteristics: - flange dimensions according to EN 1092-2, - Cast iron volute pump housing, - stainless steel shaft and Cast iron impeller and bronze wear rings, - unbalanced mechanical shaft seal according to EN 12756. Liquid: Pumped liquid: Liquid temperature range: Technical: Speed for pump data: Actual calculated flow: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Curve tolerance: Materials: Pump housing:

Price on request

Heating water 0 .. 120 C

1480 rpm 229 m/h 62.2 m 422 mm 422 mm BAQE ISO 9906 Annex A

Impeller:

Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM

Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard: Pump inlet: Pump outlet:

40 C 16 bar 16 bar 0.11 bar EN 1092-2 DN 150 DN 125

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

Pressure stage: Coupling type: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight:

PN16 Spacer

MMG280S 2 4 75 kW 50 Hz 3 x 380-415 D / 660-690 Y V 128 / 74 A 740 % 0,89 1480 rpm 93,5 % 94,5 % 94,0 % IP55 F

1150 kg

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

NK 125-400 -A BAQE

Price on request

Note! Product picture may differ from actual product

Non-self priming, single-stage centrifugal pump according to EN 1092-2. The pump is for the pumping of thin, clean or slightly contaminated liquids without abrasive or long-fibred solids. Pump and 3-phase AC motor are mounted as separate units on a common baseplate and connected via a Spacer-coupling. The impeller is hydraulically as well as dynamically balanced. The pump has the following characteristics: - flange dimensions according to EN 1092-2, - Cast iron volute pump housing, - stainless steel shaft and Cast iron impeller and bronze wear rings, - unbalanced mechanical shaft seal according to EN 12756. Liquid: Pumped liquid: Liquid temperature range: Technical: Speed for pump data: Actual calculated flow: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Curve tolerance: Materials: Pump housing:

Heating water 0 .. 120 C

1480 rpm 229 m/h 62.2 m 422 mm 422 mm BAQE ISO 9906 Annex A

Impeller:

Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard: Pump inlet: Pump outlet: Pressure stage: Coupling type: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight:

40 C 16 bar 16 bar 0.11 bar EN 1092-2 DN 150 DN 125 PN16 Spacer

MMG280S 2 4 75 kW 50 Hz 3 x 380-415 D / 660-690 Y V 128 / 74 A 740 % 0,89 1480 rpm 93,5 % 94,5 % 94,0 % IP55 F

1150 kg

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:
H (m) 100 % 60 Technical: Speed for pump data: Actual calculated flow: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Curve tolerance: Materials: Pump housing: 1480 rpm 229 m/h 62.2 m 422 mm 422 mm BAQE ISO 9906 Annex A

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
NK 125-400/422 Losses in fittings and valves not included Q = 686 m/h 1 H = 62.2 m n = 3 x 100 % switch-on at 2 Pumped liquid = Heating water 3

Description Product name: Product No: EAN number:

Value NK 125-400 -A BAQE < > < >

50 4 40

30 Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Cast iron EN-JL1030 DIN W.-Nr. A48-30 B ASTM A

20

Impeller:

10 Eta pump = 74.5 % 1000 1200 Q(m/h)

Material code: Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard: Pump inlet: Pump outlet: Pressure stage: Coupling type: Neck ring(s): Liquid: Pumped liquid: Liquid temperature range: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: Motor range: Others: Net weight:

40 C 16 bar 16 bar 0.11 bar EN 1092-2 DN 150 DN 125 PN16 Spacer neckring(s)

0 0 P2 (kW) 250 200 150 100 50 0

200

400

600

800

Heating water 0 .. 120 C

MMG280S 2 4 75 kW 50 Hz 3 x 380-415 D / 660-690 Y V 128 / 74 A 740 % 0,89 1480 rpm 93,5 % 94,5 % 94,0 % IP55 F PTC 83415140 Standard

1150 kg

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

H (m) 100 % 60 2 50 4 40 3 1

NK 125-400/422 Losses in fittings and valves not included Q = 686 m/h H = 62.2 m n = 3 x 100 % switch-on at Pumped liquid = Heating water

30

20

10

0 0 P2 (kW) 250

200

400

600

800

1000

1200

Eta pump = 74.5 % Q(m/h)

200

150

100

50 P2 = 156 kW

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

125

8x19

830 8x23 = 1340 28 110 150 = 831

1753

Note! All units are in [mm] unless others are stated.

140

2000

890

130

445

400

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Note! All units are in [mm] unless others are stated.

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:
Sizing result Type Main Circulator flow or return Your Requirements Allowed flow undersize Flow (Q) Head (H) Max. inlet pressure Max. liquid temperature Max. operation pressure Min. inlet pressure Control Mode Decrease at low flow Frequency Converter Edit Load Profile Consumption Q1 Consumption Q2 Consumption Q3 Consumption Q4 Heating season Load profile Time T1 Time T2 Time T3 Time T4 Configuration Of these: number of standby pumps Preferred number of poles Total number of pumps Pump design End Suction, Close Coupled End Suction, Long Coupled Impeller trim allowed Inline Inline Canned Rotor P2 according to ISO 5199 With spacer coupling Operational Conditions Ambient temperature Frequency Min. power limit for SD start Phase Voltage Hit list settings Allow uncontrolled Calculation period Energy price Evaluation criterion Max. hits per product group Max. hits total Load Profile Flow Head 1 98 97 2 75 87 3 50 78 4 25 72 % % Parallel 1 4 4 Yes Yes Yes Yes Yes No No 20 C 50 Hz 5.5 kW 1 or 3 1 x 230 or 3 x 400 V No 15 years 0.1 EUR/kWh Price + energy costs 2 8 Prop. pressure, Ext. 30 % External for all pumps 700 m/h 525 m/h 350 m/h 175 m/h 185 days Standard profile 266 h/a 666 h/a 1554 h/a 1954 h/a 2% 700 m/h 64 m 2 bar 70 C 10 bar 1.5 bar

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Input Select Type of Installation

NK 125-400/422 Impeller: 422 mm Quantity 4 Supply 380-415 D/660-690 Y V Motor 75 kW speed controlled Flow 686 m/h Head 62.2 m Max. velocity 3.88 m/s Min.inlet pressure 0.11 bar ( 70 C, against atmosphere) Power P1 167 kW Power P2 156 kW Eta pump 74.5 % Eta motor 93.5 % Eta pump+motor 69.7 % =Eta pump * Eta motor Eta total 61.5 % =Eta relative to the duty point Energy consumption 323050 kWh/Year CO2 emission 184000 kg/Year Price On request EUR Energy cost 32305 EUR /Year Price + energy costs On request EUR /Years All pumps with variable speed; the required control (modified Control 2000 ME) is available on request Be aware that the flow is more than 2 % below the requested duty point.

H (m) 100 % 60

NK 125-400/422 Losses in fittings and valves not included 1 2

50 4 40 30 20

Q = 686 m/h H = 62.2 m 10 n = 3 x 100 % switch-on at Pumped liquid = Heating water 0 0 200 400 600 800 P2 (kW) 200 150 100 50 0

Eta pump = 74.5 % 1000 1200 Q(m/h)

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Load profile Q 700.0 [m/h] 525.0

350.0

175.0

266

932 1 98 97 189 266 50282 3 2 75 87 124 666 82721 2 3 50 78 75.7 1554 117608 1

2486 4 25 72 37.1 1954 72436 1 % % kW h/Year kWh/Year

t 4440 [h]

Flow Head P1 Time Energy consumption Quantity Total head Dimensioning flow

64 m 700 m/h

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 700 64 25 Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Order Data:
NK 125-400 -A BAQE Amount: Product No: Actual calculated flow: Resulting head of the pump: Shaft seal: Coupling type: Actual impeller diameter: Impeller material: Pump housing material: Motor No: Motor range: Mains frequency: Rated voltage: Rated power - P2: Price: Total: Price on request ;

4 < > 229 m/h 62.2 m BAQE Spacer 422 mm Cast iron Cast iron 83415140 Standard 50 Hz 3 x 380-415 D / 660-690 Y V 75 kW On request