Вы находитесь на странице: 1из 21

WORKING PROCEDURE FOR CADWORX

TABLE OF CONTENTS
1. PURPOSE............................................................................................................................3 2. FIELD OF APPLICATION....................................................................................................3 3. ABBREVIATIONS................................................................................................................3 4. REFERENCE DOCUMENTS..............................................................................................3 5. RESPONSABILITIES...........................................................................................................3 5.1 PROJECT MANAGER ..................................................................................................3 5.2 Headpiping......................................................................................................................3 5.3 Piping coordinator...........................................................................................................3 5.4 Cadadmin........................................................................................................................3 5.5 Network administrator.....................................................................................................3 5.6 User.................................................................................................................................4 6. PROCEDURE......................................................................................................................4 6.1 IMPLEMENTING A NEW PROJECT .............................................................................4 6.2 Piping 3D Model..............................................................................................................4 6.2.1 Work environment configuration .............................................................................4 6.2.2 Pipes, elbows, tees, reducers...................................................................................5 6.2.3 Flanges, gaskets, bolts.............................................................................................6 6.2.4 Valves.......................................................................................................................6 6.2.5 Weldolet....................................................................................................................6 6.2.6 Offset connection (OTAP).........................................................................................7 6.2.7 TAP connection.........................................................................................................7 6.2.8 Pipe support..............................................................................................................7 6.2.9 Miscellaneous components....................................................................................10 6.2.10 Isogen supplemental.............................................................................................11 6.2.11 Insulation...............................................................................................................11 6.3 Equipment.....................................................................................................................11 6.4 Civil...............................................................................................................................11 6.5 EMSR............................................................................................................................13 6.6 Working with external references.................................................................................14 6.7 Review..........................................................................................................................14 6.8. Isometrics.....................................................................................................................14 6.9. Layouts.........................................................................................................................15 6.9.1 Usual format............................................................................................................16 6.9.2 Customer format (Petrom Symbolica)..................................................................17 6.10 Bill of materials...........................................................................................................17 6.11 Archiving, saving, ploting............................................................................................17 6.12 Observations...............................................................................................................19

2 / 21

1. PURPOSE
This procedure explains how to work with Cadworx software inside the our Company. Is not a user manual for Cadworx

2. FIELD OF APPLICATION
The procedure is applicable in 3d modeling, layout and isometrics production. The procedure will be applied by the piping department, project managers and network administrator

3. ABBREVIATIONS
PM project manager Headpiping- chief of piping department PC piping coordinator Cadadmin- Cadworx administrator Netadmin- Network administrator User- piping engineer designate to work in a project with Cadworx

4. REFERENCE DOCUMENTS
CADWorx Plant User Guide.pdf SmartPlant Isometrics User Guide.pdf CADWORX-EQUI-CURS.pdf

5. RESPONSABILITIES
5.1 PROJECT MANAGER
Communicate to Network administrator the list with the engineers involved in the project - Notify users if the isometrics must be delivered in Cadworx format or SmartPlant format - Notify users if the drawings should be delivered in the usual format or in Symbolica format - Communicate customer requirement. - Provide an available topo study

5.2 HEADPIPING
Decide the name of the engineer involved in the project Approve the list with special componets

5.3 PIPING COORDINATOR


Handle to cadadmin the list with needed pipeclasses and the list with special components Assign to each user a number of lines. Ensure the proper location on the server of the topo study Communicate to users PM notifications Crete back-up copies of the project

5.4 CADADMIN
Generate the structure of the project Introduce in the project the needed pipeclasses and the specific components Generate the nwd files

5.5 NETWORK ADMINISTRATOR


Assign rights for the users on the project Assign the location on the server for backup

3 / 21

5.6 USER
Generate the list with specific components Create the 3d model Generate isometrics Generate layouts Generate cross sections

6. PROCEDURE
6.1 IMPLEMENTING A NEW PROJECT
Cadadmin will create the structure of the new project in the location H:\CadworxIso\ Newproject PM/ Headpiping will communicate to Netadmin the user list with full access on location H:\CadworxIso\Newproject. All users must have mapped the dive H Following PC request, Cadadmin will introduce the needed pipe classes in the location H:\CadworxIso\Support\Spec. In location H:\CadworxIso\Support just Headpiping and Cadadmin will have full access. PC will handle (if necessary) to cadadmin a list containing specific components (which are not present in the pipe classes). Form F1-H-E (h:\CADWorx Iso\Support\) must be used. After completion the form will be placed in location H:\CadworxIso\ Newproject \Data\Models\Various Observation: a. The information introduced in this list will be used in the pipeclass. b. one list per project will be used The available specification (in Excel format) can be found in the location: H:\CadworxIso\Support\Spec_xls

6.2 PIPING 3D MODEL


6.2.1 Work environment configuration Cadworx Plant software will be used. Each user will create at least one file in location: H:\CadworxIso\Newproject\Data\Models\Piping. Is recommended to use a single pipe class in one file. PC/ Headpiping will assign each user a number of lines. A line should not be present in 2 files. Users can find template files in location: H:\CadworxIso\Support\Templ The first thing to do in the new file is to choose the configuration file. Configuration file name will be identical with the pipe class name. The steps to be done are: Plant menu Setup Edit Config File Restore ConfigFile.cfg ConfigFile.cfg will be placed in location H:\CadworxIso\Support\System The next step will be the pipe class selection. The spec view dialog box must be activated Plant Palettes Spec View

4 / 21

From the same dialog box the main size and the reduction size must be selected. Also the line number must be introduced. The line number from the model matches with the line number from the P&ID but cannot contain special character . Is recommended to use (``). The line number must be identical with the line number from csv/xls file. Is mandatory to turn on Specification Option toggle (toolbar Settings) when the user want to insert components with rating different than the pipe class rating If the user want to introduce a line with a different pipe class is mandatory to follow the same steps: first choose the configuration file than the spec file and so on. Usage of a spec file which is not matching the config. file will produce wrong list of materials. Measurements units must be: mm The pipes will be modeled in real coordinates from the beginning (if possible). The topo study must be used like referenced file. Location for topo study: H:\CadworxIso\Newproject\Data\Models\Various. This file must be identical with the file located in a P:\year\Newproject\ . If a new revision of the topo study is released PC must place the file in the both location. 6.2.2 Pipes, elbows, tees, reducers Auxiliary lines can be used for pipes center lines (select layer Linii) 2D Tracing The center lines will be placed on the XY plan of the current UCS. If necessary, new ucs will be created. Command entry: UCS N 3p select coordinate for the new UCS The new UCS must be saved with a new name Command entry: UCS S Type name for new UCS Activate toolbar Buttweld Plant menu Toolbars Buttweld Elbows and tees must be inserted first and after that, the pipes For elbow Select T Pick corner point Pick first direction: Pick second direction:

For trimmed elbow Command entry: Bent C (corner) Pick first direction: Pick second direction Enter For tee Select For reducer Select

Pick start point Pick main direction: Pick branch direction

Pick large end point: Pick small end direction:

For ecc reducer Select

Pick large end point: Pick small end direction:

For pipe Select

Pick start point: Pick end point:

3d Tracing A 3D polyline will be created

5 / 21

Command entry: 3dpoly Pick start point: Pick next point Pick next point... The pipe will be generated with the following steps: Plant menu Accessory Auto route Buttweld LR select 3D polyline 6.2.3 Flanges, gaskets, bolts If Specification Option toggle is turned off, will be inserted flanges, gaskets and bolts according to the pipe class rating Activate toolbar Flanges and Gasket Plant menu Toolbars Flanges Plant menu Toolbars Gasket Select Pick start point: Pick direction

The gaskets will be inserted automatically with the flanges The bolts will be inserted from the toolbar Gasket Select Select piping components (gasket)

If flanges with different rating are required (for instrument service) Specification Option toggle must be turned on. A dialog box will appear and the proper component must be inserted

Also for bolts for different rating Specification Option toggle must be turned on. 6.2.4 Valves Activate toolbar: Flanged valves Plant menu Toolbars Flanged valves Select Pick start point: Pick direction

Specification Option toggle must be turned on for rating different than the pipe class rating 6.2.5 Weldolet Activate toolbar Fittings Plant menu Toolbars Fittings Select Pick start point: Enter direction [Up/Down] <Up>:

Check the branch table for the available dimensions

6 / 21

6.2.6 Offset connection (OTAP) Offset connection are needed for pipe-to-pipe branches, long welding neck flange, DIN flanged nozzle, DIN temp nozzle Command entry: otap Pick branch end point: Pick second point Second point must be on the main pipe center line With cedit command otap attribute can be changed. Alpha size must be identical with branch size. Otap line number must be identical with main pipe line number On cedit dialog box press ISOGENbutton. Change SKEY value to TESO The length of the OTAP for pipe to pipe connection is shown bellow
Main size 0.5
3/4 3/4

1 1/2

Branch size 6 8

10

12

14

16

18

20

8 12 21 28 43 56 83 109 136 161 177 202 228 253 304 10 20 27 42 55 83 108 135 161 177 202 228 253 304 17 25 41 54 82 108 135 161 176 202 227 253 304 18 37 51 80 106 134 160 176 201 227 252 304 32 48 78 105 133 159 175 200 226 252 303 35 71 100 129 155 172 198 224 250 301 61 93 123 151 168 194 221 247 299 70 107 138 156 184 212 239 293 81 119 140 171 200 229 284 87 113 150 183 214 272 73 122 161 195 258 98 143 181 247 104 152 227 110 202 168

1
1 1/2

2 3 4 6 8 10 12 14 16 18 20 24

6.2.7 TAP connection Tap is used to connect 2 pipe components or to avoid discontinuities Command entry: TAP Pick point (endpoint of the tapping component Select entity (center line of the component that is being tapped) enter 6.2.8 Pipe support Activate palette Pipe Suport Modeler Plant menu Palettes Pipe Support Modeler Select file: _Company UM.psa For DIN pipe class UM=MM For ANSI pipe class UM=M Select the proper pipe support (slide, guide or fixed) and place it in the drawing by pressing the INSERT button For guide supports the direction of the support must be specified Command entry: Cedit Select objects: ISOGEN select direction (from Spindle/flat/Support Direction) For elbow pipe support Select bend support from Support palette press insert select object select enter press OK (in Select Optional value dialog box) press C (at specify support end point or change support start point) select direction (place the mouse arrow on the desired direction but do not click the mouse button) introduce the value for the support height H Obs: to successfully select direction the polar tracking must be on

7 / 21

The height of the support must be in accordance with the table 1 from OMV norm H544-04 (shown bellow).

8 / 21

After inserting the pipe support the height of the support must be added to the support description. By default the type of the support is 1. If the the type of the support is different (see the table above) the value for type support in long description must be changed Sample elbow support description : BGLW-1-50 H544-04/11 H=136 Type of support Height of support

When the isometric will be generated a detailed sketch will be placed in the drawing.

9 / 21

If axial stop with guides are needed first insert the axial stop and then insert the guides (in the same point). If auxiliary lines are needed, use layer Linii_suportifor pipe support. The layer Linii(for auxiliary lines for pipes) must be frozen 6.2.9 Miscellaneous components Activate toolbar Miscellaneous Plant menu Toolbars Misc For flanged strainer: Command entry: LARE Flanged end point or <last point> [Center/Flanged end]: Flanged end main direction: Flanged end branch direction: The reduction size must be in accordance with the drain nozzle For spectacle blind Select Pick start point Pick direction Enter an option (Open/closed) Enter degree direction For restricted orifice Select Pick start point Pick direction

There are some pipes components which are present in the pipe class but dont have proper buttons in cadworx. In this case we will use components defined with user shape command. For sight glass: Select 1 (user shape 1) Pick location: Pick rotation For protective strainer: Select 2 (user shape 2) Pick location: Pick rotation For BW Strainer: Select 3 (user shape 3) Pick location: Pick rotation For DIN Flanged nozzle: Select 4 (user shape 4) Pick location: Pick rotation For DIN Temperature nozzle: First turn on Specification Option toggle Select 4(user shape 4) Choose the optional component Pick location Pick rotation

10 / 21

For Steam trap: Select 5 (user shape 5) Pick location: Pick rotation 6.2.10 Isogen supplemental Isogen supplemental dialog box is necessary to insert flow arrow symbol, wall penetration, local instrument and break in location (for tie-in). Plant menu Accessory Isogen Isogen Supplemental Insertion point for break in location must be between different lines. 6.2.11 Insulation Is recommended to insert the insulation when the model (line) is completed Activate the palette Insulation view From settings tab the proper insulation must be chosen. (If necessary new value can be added with add button). After the insulation is selected, press the add to drawingbutton, and go to Apply tab. Select insulation from the Available configurationgrid and insert in the drawing using the Addbutton from the Insulation grid. Select mode must be select on screen. Insulation mode must be Data graphics

6.3 EQUIPMENT
Cadworx Equipment software will be used. Instructions for Cadworx equipment can be found in : h:\ CADWORX ISO\CADWORX-CURS\CADWORX-EQUI-CURS.pdf Equipment model will be based on the data sheet produced by the Equipment department. Depending on the number and complexity of equipment, the user will create one or more files. The files will be placed on: H:\CadworxIso\ Newproject\Data\Models\Equipmnet The nozzle which will be used must have dimensions and rating according to the pipe class

6.4 CIVIL
Cadworx Plant/AutoCAD software will be used. The model for civil works is not the base for detail design. In a first phase, this model can be considered like a construction theme for civil department. When the civil department completes the constructive solution, the model will be updated by the users The users will work just with 3D solid entities. Is recommended to use the Steel toolbar.

For inserting an HEA profile select

and the following dialog box will appear

11 / 21

For example we insert 2 profile

For coping the profiles we use the cope command from the Steel Toolbar Select Select objects to cope Enter Select coping boundaries: Enter

12 / 21

Depending on the number and complexity of the structures, the user will create one or more files The files will be located on: H:\CadworxIso\ Newproject \Data\Models\Civil

6.5 EMSR
Cadworx/AutoCAD software will be used The model for electrical installation (cable tray, cable ladder will be based on the drawings produced by the EMSR department. To insert Cable tray follow the steps: Plant HVAC SHAPES

Depending on the number and complexity of the electrical equipment, the user will create one or more files The files will be located on: H:\CadworxIso\ Newproject \Data\Models\EMSR

13 / 21

6.6 WORKING WITH EXTERNAL REFERENCES


First of all the user must check units of measurement (piping model must have mm units, but the topo study usually have m units) The ucs must be set on world. References must be overlay type and the insertion point must be 0, 0, 0

6.7 REVIEW
Cadadmin will create nwd files (containing all the drawings of the model) on the location H:\CadworxIso\Newproject\Data\Models\Review These file can be viewed with NaviWorksFreedom. These file are useful for clash detection and for a good overview of the entire project The files must be updated 1-2 times per week (or whenever is necessary)

6.8. ISOMETRICS
PM/PC will notify the users if the isometrics must be delivered in Cadworx format or SmartPlant format. At least the as built isometrics must be in SmartPlant format -Isometrics in Cadworx format The user must fill the file TitleBlock.xls located in H:\CadworxIso\ Newproject Microsoft Excel 2007 is recommended. Excel 2010 is not recommended. The user cannot write special characters in the xls/csv file :() The cells must not be in Number Format. The cells can not be on two rows In the top of the column is specified -in brackets the maximum number of characters that can be introduced. After each modification, the xls file must be converted to csv file in the same location (Cadworx can work just with csv files) The config file will be selected (see 6.2.1) The specification must be selected Plant menu Setup specification select specification If connection points are placed in other files, insert those files using xref command. Select isogen style. Isogen style must be in accordance with the cfg file (if cfg is for Ansi pipe class the isogen style must be Ansi) If the line contain both ansi and din components ansi cfg file and ansi style will be choosen. Plant menu Accessory Isogen Isogenout select directory, select style Generate isometrics Plant menu Accessory Isogen Batch select lines One or more lines can be selected Isometrics will be located on: H:\CadworxIso\ Newproject \Stil\Drawings When the isometrics are ready to be sent to the checker, the files will be placed on: H:\CadworxIso\Newproject\Data\Models\ISO -Isometrics in Smartplant format To obtain the isometrics in Smartplant we need the pcf files generated in Cadworx. These files will be automatically generated together with the isometrics (with isogen batch command) in the location H:\CadworxIso\ Newproject \ Inputs The pcf files will be copied to I:\SPIsometrics\ Newproject\Imports TitleBlock.xls file will be copied in location I:\SPIsometrics\ Newproject Open Smart plant Isometrics and import pcf files. File import select line Observation: By default SmartPlant is set on Metric/Inch Bores. If the user want to import lines with Metric/ MM bores (or with both type of units), he must inform the cadadmin. We generate the isometrics File Generate drawings A dialog box will appear: We select the iso style:
14 / 21

We select the option Style Setting for North arrow

The isometrics will be found in location I:\SPIsometrics\ Newproject \ Stil\Drawings The native files (*.pod) will be saved in the location I:\SPIsometrics\ Newproject\Pipes

6.9. LAYOUTS
PM/PC will notify users if the layout should be delivered in the usual format or the format desired by the customer (Petrom_Symbolica). These formats do not exclude each other completely. Is possible that the first edition to be in the usual format and the last one to be in the customer format.

15 / 21

6.9.1 Usual format Cadworx Plant/AutoCAD software will be used. In location H:\CadworxIso\ Newproject\Data\Models\Layout one single file will be created. Is not mandatory that this file must be created when the model is finished In the model tab will be inserted (with xref command) all the files needed for the layout. For each drawing a layout will be created. In layout tab will be inserted title block and borders delivered by the customer (paper space mode will be selected) Views will be inserted with viewports (one by one) in Layout tab View Viewport New Viewport Active Model configuration. Visual style in Viewport dialog box must be set on Wireframe Paper size will be selected in page setup (oversize type). The scale of the drawing must be specified in Scope of work. If not a standard scale will be used (the drawing must be readable). The scale will be applied to the frame and the title block. The geometry will be made in absolute sizes (OMV norm 351). The scale of the viewport will be set to 1:1. After the scale selection the viewport must be locked For section and partial views the viewbox command is recommended (in this way we cut o slice form the mdel). Before introducing this command, auxiliary lines (defining the opposite corner of the box) can be drawn. Plant menu Utility View Viewbox dialog box

Select the views to be generate

After we define the box and the types of view, we choose the desired view from the viewport dialog box

16 / 21

Dimensioning Dimension styles of the customer will be used Dimensions will be placed in layout tab in viewports. All dimensions must be attached to the entities from the model. In this way updates in the model will lead to the dimension update Before the plotting the visual style must be changed from Wireframe In Hidden After the layout is complete they will be extracted in pdf format in location: H:\CadworxIso\Newproject\Data\Models\Layout\pdf 6.9.2 Customer format (Petrom Symbolica) Cadworx Plant software will be used. The usual format can be considered the base for the Customer Format The main difference between the usual format and the customer format is the use of the 2drep command (2d representation) 2drep will be applied to all the viewports Command entry: 2drep select object Enter All the entities (obtained with 2drep) will be placed in Symbolica Layers The layouts will be exported to new drawings with wblock command.

6.10 BILL OF MATERIALS


The list of material will be generated for each pipe class. The configuration file must be selected according to the pipe class (see 6.2.1) The user must configure the style for the list of the material Plant menu Bill of material Setup select : Mark, Alpha size, Long_desc, DB_code, Length, Quantity, Spec_file Generate list of materials in an Excel file Plant Bill of material Export T (total length) L (line number) L (list) select lines. List of materials will be saved in location H:\CadworxIso\ Newproject\Data\Models\ MTO. Afterwards these lists will be converted using Customer template Is recommended to run a list of materials before isometrics (just for checking)

6.11 ARCHIVING, SAVING, PLOTING


17 / 21

PC/Cadadmin will make periodically backups for all active projects. Before saving, the users must perform the Purge command When many drawings must be plotted is recommended to use the publish command. In this case Autocad will be used and not Cadworx. File Publish A dialog box will appear:

Add files

In Include box Model must be selected

18 / 21

Page setup must be imported

File SetupF7 will be placed in location: I:\SPIsometrics\ Newproject\Style\ Drawings

In the end press Publish and the drawings will be ploted

6.12 OBSERVATIONS

19 / 21

To obtain readable isometric drawings use stop sign (or additional flow arrow). Is not allowable to leave connection point in the air (near other connection point or pipe center line).

Is not allowable to use Symbolica layers in the piping model. Is not recommended to use the stretch command. If, however is used, is recommended to use the convertsolid for the stretched component. Using cadworx 2010 is possible to insert pipe components which are not in accordance with the pipe classes. The user must have always on his desk the pipe class and the part descriptions. Is not recommended to insert components from the spec view palette. Two weldolets can not have the same insertion point. A gap of few mm must exist If you want to delete an attribute in xls/csv file (for a line wich has been already generated) dont leave blanks (place for example -).

20 / 21

21 / 21