Вы находитесь на странице: 1из 15

D EUTSCHE NORM

Non-destructive testing of welds

September 2002

Ultrasonic testing of welded joints


Acceptance levels (includes Amendment A1 : 2002) English version of DIN EN 1712 : 1997 + A1 : 2002
ICS 25.160.40 Zerstrungsfreie Prfung von Schweiverbindungen Ultraschallprfung von Schweiverbindungen Zulssigkeitsgrenzen (enthlt nderung A1 : 2002)

EN 1712
Supersedes September 1997 edition.

European Standard EN 1712 : 1997 + Amendment A1 : 2002 has the status of a DIN Standard.
A comma is used as the decimal marker.

National foreword
This standard has been prepared by CEN/TC 121 Welding (Secretariat: Denmark), SC 5 Non-destructive tests of welds. The responsible German body involved in its preparation was the Normenausschuss Materialprfung (Materials Testing Standards Committee), Technical Committee Ultraschallprfung. Amendments This standard differs from the September 1997 edition in that it has been editorially revised and Annex ZA has been included. Previous edition DIN EN 1712: 1997-09.

Continued overleaf. EN comprises 13 pages.

No part of this standard may be reproduced without the prior permission of DIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany, has the exclusive right of sale for German Standards (DIN-Normen).

Ref. No. DIN EN 1712 : 2002-09


English price group 08 Sales No. 1108 01.03

EN 1712
September 1997

+ A1
May 2002 ICS 25.160.40 Descriptors: Supersedes EN 1712 : 1997.

English version
Non-destructive testing of welds

Ultrasonic testing of welded joints


Acceptance levels (includes Amendment A1 : 2002)
Contrle non destructif des assemblages souds Contrle par ultrasons des assemblages souds Niveaux dacceptation (amendement A1 : 2002 inclus) Zerstrungsfreie Prfung von Schweiverbindungen Ultraschallprfung von Schweiverbindungen Zulssigkeitsgrenzen (enthlt nderung A1 : 2002)

This European Standard was approved by CEN on 1997-07-24 and Amendment A1 on 2002-05-01. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. The European Standards exist in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom.

|
European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Management Centre: rue de Stassart 36, B-1050 Brussels

2002. CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national members.

Ref. No. EN 1712 : 1997 + A1 : 2002 E

Page 2 EN 1712 : 1997 + A1 : 2002

Contents
Page

Foreword to EN 1712 : 1997 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Foreword to EN 1712 : 1997/A1 : 2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Normative references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 Evaluations of indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.2 Sensitivity setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.3 Reference level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.4 Evaluation level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.5 Recording level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.6 Measurement of indication length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4 Acceptance levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.2 Longitudinal indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.3 Transverse indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.4 Indications detected by the tandem technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.5 Linearly aligned and grouped indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4.6 Cumulative length of acceptable indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5 Examination report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Annex A (informative) Acceptance levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Annex B (normative) Fixed amplitude level technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Annex ZA (informative) Clauses of this European Standard addressing essential requirements or other provisions of EU directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Foreword to EN 1712 : 1997


This European Standard has been prepared by Technical Committee CEN/TC 121 Welding, the Secretariat of which is held by DS. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the relevant EU Directives. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, and conflicting national standards withdrawn, by February 1998 at the latest. In accordance with the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom.

Foreword to EN 1712 : 1997/A1 : 2002


This amendment to EN 1712 : 1997 has been prepared by Technical Committee CEN/TC 121 Welding, the Secretariat of which is held by DS. This amendment has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the relevant EU Directives. For relationship with these directives, see Annex ZA. This amendment shall be given the status of a national standard, either by publication of an identical text or by endorsement, and conflicting national standards withdrawn, by November 2002 at the latest. In accordance with the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom.

Page 3 EN 1712 : 1997 + A1 : 2002

This European Standard specifies ultrasonic acceptance levels, 2 and 3, for full penetration welded joints in ferritic steels, which correspond to quality levels B and C of EN 25817. Other acceptance levels can be used by specification. An acceptance level corresponding to level D of EN 25817 has not been included in this standard as ultrasonic testing is not recommended for this weld quality. These acceptance levels are applicable to testing carried out in accordance with the standards referred to in EN 12062. They can, however, be applied in conjunction with other rules, where the same types of reference reflectors for sensitivity setting are used, provided it is agreed between the contracting parties. The standard is applicable to the testing of full penetration ferritic steel welds, with thicknesses from 8 mm up to 100 mm. It can also be used for other types of welds, materials and thicknesses above 100 mm, provided the testings have been performed with necessary consideration of the geometry and acoustical properties of the component and an adequate sensitivity can be employed to enable the acceptance levels of this standard to be applied. The nominal frequency of probes used in this European Standard is between 2 MHz and 5 MHz unless attenuation or requirements for higher resolution call for another frequency. The use of these acceptance levels in conjunction with frequencies outside this range needs to be considered carefully.

The evaluation of indications shall be performed on indications detected by testing performed in accordance with EN 1714.

Page 4 EN 1712 : 1997 + A1 : 2002

Page 5 EN 1712 : 1997 + A1 : 2002

The acceptance levels shall be related to the testing techniques (testing levels) as defined in EN 1714. Acceptance level 2 will normally require at least testing level B, and for acceptance level 3 at least testing level A. Any other relationship between acceptance levels and testing levels shall be defined by specification.

Page 6 EN 1712 : 1997 + A1 : 2002

Evaluation of indications may include discrimination between different types of discontinuity if defined in a specification. In such case, the characterisation as a planar indication may be used as the primary discrimination of an acceptable or rejectable indication. In this case all indications with echo amplitude above the evaluation level shall be characterised, and all that are characterised as planar shall be rejected. For welds subject to fatigue loading, near surface acceptance levels may be defined in a specification.

The acceptability of indications detected by the tandem technique is to be defined by specification.

Page 7 EN 1712 : 1997 + A1 : 2002

Page 8 EN 1712 : 1997 + A1 : 2002

Page 9 EN 1712 : 1997 + A1 : 2002

Page 10 EN 1712 : 1997 + A1 : 2002

Page 11 EN 1712 : 1997 + A1 : 2002

Page 12 EN 1712 : 1997 + A1 : 2002

Page 13 EN 1712 : 1997 + A1 : 2002

Вам также может понравиться