This limiter avoids overloads in cranes and elevators. It has two relay outputs and one analog output. The RELAY 1 is inmediatly action to load limiter the RELAY 2 has an asociated timer and is used as an advice or pre-alarm. The 4/20mA analog output weight proportional allows a remote indicator or PLC conexion.
TECHNICAL DATA
- LOAD CELL. - Easy installation wire rope sensor. - Internal SPAN and ZERO adjustements. 48 VAC, 120 VAC, 230 VAC / 3,5 VA (with "Power on" light) - N.O. and N.C. relay contacts. - 2 adjustable alarm set points. - 2 light indicator of "on" state. * Relay 1. Trigger, for Max level.. * Rel 2. Trigger, for Max or Min level by strap selecction. Timer of rele 2 (,5...5seg) adjustable. - 4/20mA output with 500 W max load resistor.
OUTPUT SELECTION: o o o 4/20mA output is the trigger level 1. o o o 4/20mA output is the trigger level 2. o o o 4/20mA is the weight output.
- ANALOG OUTPUT
DIMENSIONES
105 75 38
19 20 21 22
POWER
230V 120V 48V 0V
Alimentacin
30 31 32 33 34 35 1
NC CC NA ALARMA NC CC NA ALARMA
90
Ziur-2
CELULA
AJUSTES de NIVEL
T emporizador
-I
ABRIR
+I
11
12
SALIDA 4/20mA
Material Colour Dimensions (in mil.) Weight Rail Mounted Conexions Calibration acces
ABS.Autoextinguible UL-94 Grey RAL 7.035 105 x 90 x 75 400 gr DIN EN 50022 screw terminals folding cover case
06.e-Pag1
SECURITY
- Power supply fail safe. - If "Broke sensor" or "No-sensor" is detected. - The calibration parameters are inside.
REL1 turns on
CONEXIONS
REFERENCES: ZIUR - 2
POWER SUPPLY
ACTIV. ALARMA 1
Poweron
120VAC 48VAC
ACTIV. ALARMA 2
230VAC MX
MXIMA
RELAY 1
RELAY 2
MNIMA
1
19 20 21 22
230 V 120 V power 48 V 0V Supply
2T
led1
30 31 32
NC alarma1 CC NA
33 34 35
NC CC NA alarma2
led2
ZIUR - 2
LEVEL ADJUSTEMENTS
Timer
-IN
+IN
-OUT
+OUT
-I
Loal Cell Open
+I
seleccin de salida
Out 4/20 mA
11 12
+Exc
-Exc
-mV
+mV
LOAD CELL
mA
4/20 mA OUTPUT
06.e-Pag2