Silicon PIN Diode


• Current-controlled RF resistor
for switching and attenuating applications
• Frequency range 1 MHz ... 2 GHz
• Especially useful as antenna switch
in TV-sat tuners
• Very low harmonics

BA595 BA885
BA895
!

Type Package Configuration LS(nH) Marking


BA595 SOD323 single 1.8 white R
BA885 SOT23 single 1.8 PA
BA895 SCD80 single 0.8 RA
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter Symbol Value Unit
Diode reverse voltage VR 50 V
Forward current IF 50 mA
Junction temperature Tj 150 °C
Operating temperature range Top -55 ... 125
Storage temperature Tstg -55 ... 150

Thermal Resistance
Parameter Symbol Value Unit
Junction - soldering point1) RthJS K/W
BA595, BA885 ≤ 370
BA895 ≤ 95
1For calculation of RthJA please refer to Application Note Thermal Resistance

1 2005-10-19
BA595/BA885/BA895...

Electrical Characteristics at TA = 25°C, unless otherwise specified


Parameter Symbol Values Unit
min. typ. max.
DC Characteristics
Reverse current IR - - 20 nA
VR = 30 V
Forward voltage VF - - 1.1 V
I F = 50 mA
AC Characteristics
Diode capacitance CT pF
VR = 0 V, f = 100 MHz - 0.26 0.4
VR = 10 V, f = 1 MHz - 0.22 0.6
Reverse parallel resistance RP kΩ
VR = 1 V, f = 100 MHz - 50 -
VR = 0 V, f = 1 GHz - 10 -
Forward resistance rf Ω
IF = 1.5 mA, f = 100 MHz - 22 40
IF = 10 mA, f = 100 MHz - 4.5 7
Charge carrier life time τ rr - 1600 - ns
IF = 10 mA, IR = 6 mA, measured at IR = 3 mA ,
RL = 100 Ω
I-region width WI - 130 - µm

2 2005-10-19
BA595/BA885/BA895...

Diode capacitance CT = ƒ (VR) Forward resistance rf = ƒ (I F)


f = Parameter f = Parameter

BA 885 EHD07016
0.5 10 3
pF
rf Ω

0.4
1 MHz
0.35 100 MHz
1 GHz 10 2
CT

0.3

0.25

0.2
10 1
0.15

0.1

0.05

0 10 0
V
0 5 10 15 20 30 10 -1 10 0 10 1 mA 10 2
VR ΙF

Forward current IF = ƒ (VF) Forward current IF = ƒ (T S)


TA = Parameter BA595

10 0 60
mA
mA

10 -1 50

45
-2
10 40
IF
IF

35
-3
10 30

25
-40°C
10 -4 +25°C 20
+85°C
+125°C 15
-5
10 10

5
-6
10 0
0 0.2 0.4 0.6 0.8 1 °C 1.3 0 15 30 45 60 75 90 105 120 °C 150
TS TS

3 2005-10-19
BA595/BA885/BA895...

Forward current IF = ƒ (T S) Permissible Puls Load R thJS = ƒ (tp)


BA895 BA595

60 10 3
mA
K/W
50

45

R thJS
40 10 2
IF

35

30

25 0.5
1
0.2
20 10 0.1
0.05
15 0.02
0.01
10 0.005
D=0
5

0 10 0 -6 -5 -4 -3 -2 0
0 15 30 45 60 75 90 105 120 °C 150 10 10 10 10 10 s 10
TS tp

Permissible Pulse Load Permissible Puls Load R thJS = ƒ (tp)


IFmax / I FDC = ƒ (t p) BA595
BA595
10 1 10 3

K/W
IFmax/IFDC

D=0
RthJS

10 2
0.005
0.01
0.02
- 0.05
0.1
0.2
0.5 0.5
10 1 0.2
0.1
0.05
0.02
0.01
0.005
D=0

10 0 -6 -5 -4 -3 -2 0
10 0 -6 -5 -4 -3 -2 0
10 10 10 10 10 s 10 10 10 10 10 10 s 10
tp tp

4 2005-10-19
BA595/BA885/BA895...

Permissible Pulse Load


IFmax / I FDC = ƒ (t p)
BA895
10 1
I Fmax/IFDC

D=0
0.005
0.01
0.02
- 0.05
0.1
0.2
0.5

10 0 -6 -5 -4 -3 -2 0
10 10 10 10 10 s 10

tp

5 2005-10-19
Package SCD80 BA595/BA885/BA895...

Package Outline

0.2 M A
+0.05
0.8 ±0.1 0.13 -0.03
A
2

7˚ ±1.5˚
10˚MAX.
1.7 ±0.1

1.3 ±0.1
Cathode 1

0.2 ±0.05
marking 0.3 ±0.05 0.7 ±0.1

Foot Print 0.35


1.45

0.35

Marking Layout

Date code 2003, July

Type code BAR63-02W


Laser marking Cathode marking

Example

Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel

4 0.2
1.45

8
2.5

Cathode 0.4 0.7


marking 0.9

6 2005-10-19
BA595/BA885/BA895...

Data Code marking for discrete packages with


one digit (SCD80, SC79) CES-Code
Month 2 0 03 2 0 04 2005 2006 2 0 07 2008 2009 2010 2011 2012 2 0 13 2014
01 a p A P a p A P a p A P
02 b q B Q b q B Q b q B Q
03 c r C R c r C R c r C R
04 d s D S d s D S d s D S
05 e t E T e t E T e t E T
06 f u F U f u F U f u F U
07 g v G V g v G V g v G V
08 h x H X h x H X h x H X
09 j y J Y j y J Y j y J Y
10 k z K Z k z K Z k z K Z
11 l 2 L 4 l 2 L 4 l 2 L 4
12 n 3 N 5 n 3 N 5 n 3 N 5

62

7 2005-10-19
Package SOD323 BA595/BA885/BA895...

Package Outline
0.9 +0.2
-0.1
+0.2
1.25 -0.1 0 ±0.05
A
2

0.45 ±0.15
2.5 ±0.2
Cathode

1.7 +0.2
-0.1
marking

1
0.3 +0.1
-0.05
+0.05
0.3 -0.2

0.15 +0.1
-0.06
0.25 M A

Foot Print
0.8
1.7
0.8

0.6

Marking Layout

Type code BAR63-03W


Laser marking Cathode marking
Example

Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel

4 0.2
8
2.9
2

Cathode 0.65 1
marking 1.35

8 2005-10-19
Package SOT23 BA595/BA885/BA895...

Package Outline

0.15 MIN.
1 ±0.1
2.9 ±0.1 0.1 MAX.
B
3

2.4 ±0.15

1.3 ±0.1
10˚ MAX.

10˚ MAX.
1 2
1)
0.4 +0.1
-0.05 0.08...0.1 A
C 5
0.95
0...8˚
1.9

0.25 M B C 0.2 M A

1) Lead width can be 0.6 max. in dambar area


Foot Print

0.8
0.9
1.3
0.9

0.8 1.2

Marking Layout

Manufacturer

12 s EH s
37

Date code (Year/Month) 2003, July

Pin 1 Type code BCW66


Example

Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel

4
0.9 0.2
2.13
2.65
8

Pin 1 3.15 1.15

9 2005-10-19
BA595/BA885/BA895...

Published by Infineon Technologies AG,


St.-Martin-Strasse 53,
81669 München
© Infineon Technologies AG 2005.
All Rights Reserved.

Attention please!

The information herein is given to describe certain components and shall not be
considered as a guarantee of characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of
non-infringement, regarding circuits, descriptions and charts stated herein.

Information

For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office (www.Infineon.com).

Warnings

Due to technical requirements components may contain dangerous substances.


For information on the types in question please contact your nearest Infineon
Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that life-support
device or system, or to affect the safety or effectiveness of that device or system.
Life support devices or systems are intended to be implanted in the human body, or
to support and/or maintain and sustain and/or protect human life. If they fail, it is
reasonable to assume that the health of the user or other persons may be endangered.

10 2005-10-19

Вам также может понравиться