Designed To Meet Individual Needs

PCF SERIES...
COOLING TOWERS
Induced Draft Counter Flow Multiple Cells Configuration Small To Large Capacities Compact Square Shape Small Installation Plot Area Light Weight Construction High Thermal Efficiency Low Power Consumption Drift Eliminator Inside Low Water Consumption Internal Distribution System Economical Piping Connections Robust Constructions Long Life Span

CONTENTS
Introduction ............................................................ 2 Multiple Cells System............................................... 3 Heavy Duty Contruction / Water Distribution System 4 Fill Media / Cold Water Basin .................................. 5 Mechanical Equipment / Air Inlet Louvers / Drift Eliminators................................................... 6 Access Ladder / Access Door / Civil Foundation ........ 7 4 Cells Cooling Tower With FRP Basin ....................... 8 4 Cells Cooling Tower With Concrete Basin ................ 9 Design Concepts & Features ................................... 10 PCF 50 - 100 Series Standard Tower ...................... 11 PCF 125 - 225 Series Standard Tower ............. 12 - 15 PCF 250 - 500 Series Standard Tower ............. 16 - 19 PCF 600 - 1000 Series Standard Tower ........... 19 - 23 PCF 1200 - 2000 Series Standard Tower ......... 24 - 27
2

Introduction
Cooling towers designed and manufactured in the past had been concentrated in making the cooling tower economical in production cost to meet the competitive market environment. The cooling towers were either the prototype with a few smaller models combined together to make up for the larger capacities; or single large unit of simple construction just merely serving the purpose of cooling water without considering other basic requirement of the end users. As a result, many problems were left to the end user to solve on their own. And the objective of making cooling tower economical has never been achieved in actual operation if other factors such as initial overall civil and electrical construction cost, subsequent operational cost, maintenance cost, spare parts replacement cost, down time cost and tower life span were to put together as overall consideration. As capital equipment, inefficient cooling towers cannot be simply discarded away in most cases but to tolerate with whatsoever shortcomings. With more users nowadays progressively gaining awareness on the importance of the cooling tower, PANWATER has developed the modern PCF Series cooling towers based on the users needs couple with the vast experience from more than a decade of making cooling tower using computerized thermal designing program. As a result, a completely new breed of cooling towers had been developed, tested and proven to meet every individuals most demanding needs.

Multiple Cells System


Each model of the PCF Series cooling tower has been intentionally designed with multiple cells installation flexibility to meet many cooling tower system overall design nowadays, so that the cooling tower can be synchronized with the operation of the multiple units of chillers, heat exchangers and water pumps for ease of operation control and energy conservation. For this very important reason, it has been designed into multiple cells system to provide flexibility to handle partial load for operation with varying capacities at different stages, and for different changing ambient condition within a day and different season within a year to achieve highest efficiency. As a result, PCF Series multiple cells design also simplified the overall system piping works, civil foundation works and complicated control system. All these associated cost in the overall cooling water system that provide efficient operation are normally not reflected from the cooling tower cost alone. Whereas in many conventional cooling towers, a single unit of cooling tower were being used to handle the overall thermal capacity but lacks the flexibility to take advantage of lower ambient wet bulb temperature when it is lower than the design to operate at partial load for energy conservation. And in most cases, maintenance of the larger and crucial components becomes very difficult. Any minor failure usually leads to complete shut down of the entire cooling system. Although multiple cells cooling towers have emerged in the market recently, but such cooling towers were made for the purpose of reducing the production cost with very few model. When larger unit is required, the tower size normally become unnecessarily impractical due to too many small cells. Such solution usually involved larger overall plot area, complicated piping system, high initial civil cost, complicated control system and still lacks the flexibility in operation.

Heavy Duty Construction


The external cooling tower casing, which provide the enclosure and supporting all the various components are made from the high strength, very durable and light weight FRP materials. FRP materials offer flexibility to fabricate aerodynamic profile such as the fan housing and panels with high precision and yet offer very lightweight for ease of handling and ease of assembly. FRP construction is highly desirable also due to its superior resistance to weathering and corrosion since cooling towers are to be located out door and are directly subject to severe weathering and in constant contact with water. In order to provide mechanical rigidity to the tower body, fabricated heavy gauge steel sections with hot-dip galvanized to BS 729 is used In the PCF Series cooling towers to provide the mechanical necessary for the framework to support the mechanical equipment and the entire tower body for rigidity and durability as well as to ensure long lasting life span. system and valves to achieve efficient water distribution and control is not required. This feature is particularly necessary to avoid constant monitoring of water distribution to the cooling tower by external piping system in order to achieve the intended performance efficiency. Hot circulation water return to the cooling tower via the main inlet header to each cell is redistributed through a series of smaller diameter lateral pipes and discharge onto the high efficiency PVC fill media below through the Polypropylene downwards spray nozzles. Since there is no rotating component in the distribution system, mechanical failure is eliminated. The spray nozzles are screwed-connected onto the lateral pipes with threaded connections and provided with sufficiently large openings to allow foreign solids to discharge through the nozzles without plugging. Should it become necessary, the nozzles can be easily removed from the lateral pipes to discharge larger debris trapped in the piping system. The overall distribution system operates from the residual system pressure and do not requires excessive flow rate or pressure to operate. Significant amount of power saving is expected from the circulation water pump.

Water Distribution System


Since the performance of the cooling tower is very much dependent on the effectiveness of the hot water distribution system, complete internal piping system is provided within the cooling tower. A single inlet connection flange is provided for each cell of the cooling tower is located at the sidewall casing panel for direct connection with the overall cooling water system piping. Therefore, complicated and costly external piping

Fill Media
Hot water discharge onto the fill media directly below and redistribute into very thin water film over the very large surface area provided by the corrugated fill media. While ambient air induced by the fan need to pass through the fill media before discharge into the atmosphere, the passage taken by the air allows the two mediums to contact with each other. Since water flowing downward with the induced air moving upwards forming counter current flow with each other, this type of cooling tower is commonly termed as counter flow cooling tower. With the ambient air at lower wet bulb temperature and lower enthalpy being induced into the cooling tower directly in contact with the hot water film at the fill media, heat energy is honeycomb-like packing for maximum uniform water and air distribution with air resistance to air flow is kept to minimum, thus giving very high thermal efficiency. However, excessive total surface area of the fill media is detrimental because it increase the air resistance to air flow, while insufficient total surface area requires very much higher air flow rate to achieve the desired outlet temperature. In either case, it consumes higher energy to operate the fan. Therefore, the design of the fill media to achieve an optimum air to water relationship is the key to the efficiency of the cooling tower. And both the manufacturing process and materials used for the fill media determine hoe long the efficiency can be maintained.

Cold Water Basin


Cold water after passing through the fill media is being collected at the FRP cold-water basin below. The cold water basin is assembled from molded FRP panels and provided with a hot-dip galvanized steel outlet trough at the bottom complete with all the terminating piping connections required for the outlet pipe, makeup water pipe, overflow and drain pipes. The outlet connection for the pump suction is especially provided with anti-vortex feature to prevent pump cavitations. For multiple cell arrangement, each cell is provided with its individual hot dip-galvanized steel outlet trough and piping connections therefore provides multiple outlet connections for multiple pumps operation, eliminating the need of a header pipe to interconnect all the pumps. This feature is advantageous when a larger cooling system requires a number of circulation pumps to serve a number of different applications or to make up the total flow rate required. The elimination of the large suction header pipes for the pumps provide a spacious pump area for operation and maintenance and reduce the unnecessary initial piping cost. Since the PCF Series cooling tower allow unlimited multiple cell installation configuration, the single common cold water basin serving all the cells allows any one cell or any one pump to operate individually and independently without complicated control or isolation. Since only a single common cold water basin is being used for the entire system, cumbersome balancing pipes and valves, which is very common in many larger system using multiple towers installation, is unnecessary.

being transferred from water to air by evaporation process. The heat transfer process resulted a loss of enthalpy and a very small volume of water from the water to the air as evaporation loss. Water is constantly being cooled as it passes downward the entire fill media with the water finally achieved its designed outlet temperature and collected by the cold waterbasin below. The effectiveness of the cooling process is very much dependent upon the total surface area of the water being exposed to air, the duration of air and water contact and the effectiveness of the air moving through the fill media; the configuration and the total surface area of the fill media is the utmost important factor of a cooling tower. The fill media used in the PCF Series cooling tower is manufactured from prime PVC materials and capable of withstanding as high as continuous operating temperature of 50 C and intermittent operating temperature of 55 C, exceeding most common operating temperatures in most applications. The most unique and excellent feature of the fill media being its uniform configuration when assembled into module to form a consistent

Mechanical Equipment
The reliability of a cooling tower always depending on the type of prime mover is being used for the fan either to maintain the thermal efficiency or for reliable continuous operation. Since cooling tower fans, especially with the larger diameter fans, the operational speed has to be reduced to below the maximum tip speed allowed, a speed reducer is always necessary to reduce the speed of the prime mover, i.e. electric motor. The PCF Series cooling tower employs the most durable and reliable planetary type gear speed reducer developed by PANWATER as the fan driver. Since it is the utmost important component of a cooling tower, numerous efforts had been put into the overall design of the gear speed reducer to transmit torque from the electric motor to the axial flow fan for efficient air inducement. And priority had been given to the construction of the mechanical equipment to ensure continuous and trouble free operation with minimum maintenance as well as long life span compatible to the cooling tower.

Air Inlet Louvers


Due to the increasing concern on environment cleanliness and aesthetic requirement, cooling towers had been forced to hide behind buildings or concealed behind walls. In most cases, it is due to its ugliness especially with the air inlet louvers used for the cooling tower had been very flimsy and damaged over a short period due to weathering, or in most cases, water is still splashing over the tower surroundings causing eyesore to everyone.

For larger models using the planetary gear speed reducer, electric motor is directly close coupled to the gear unit forming a single coaxial driver to operate the axial flow fan. The oil lubricated gear speed reducer is designed with a bearing life of 10,000 hours for continuous and heavy-duty operation. It is capable of withstanding high torque developed by the electric motor during starting and has very uniform torque transmission from high speed input shaft to the low speed output shaft so that wear and tear to the components is minimum. Replacement of parts only limit to the bearing and seals annually, which is predictable. Therefore eliminate the risk of unpredictable tower break down. The axial flow fans used in the PCF Series cooling tower are adjustable pitch type of cast aluminium alloy with the most efficient aerodynamic profile for best efficiency. All attachment hardware is made of stainless steel material for heavy-duty operation and long life span. The entire mechanical equipment are supported on a heavy gauge hot dip galvanized frame rigidly installed onto the FRP fan housing and complete with safety guards.

In view of this conventional problem, the overall outlook and finishing of the PCF Series cooling towers have been given a cosmetic finishing and the air inlet louvers, which is part of the tower exterior, has been designed compatible to the tower body. Air inlet louvers are provided at the lower section of the tower side walls to guide air flow into the cooling tower as well as preventing water droplets splashing out from the cooling tower causing corrosion to the surrounding area. Again, louvers made of FRP materials is being used as it is directly subject to weathering to provide smooth air flow into the tower with minimum air resistance and with an inclination to shed water back into the cold water basin. The air inlet louvers are easily removable from its attachment for access into the coldwater basin section for maintenance purpose.

Drift Eliminators
Air after passing through the fill media is moving upwards with air velocity sufficiently large to provide an upward thrust for small water droplets in the cooling tower. Careful observation will notice that a large quantity of small water droplets is floating below the operating fan and coalesce into larger water droplets and finally being drawn out of the cooling tower along with the discharge air if the cooling tower is not installed with an effective drift eliminator system. If efficient drift eliminator system is not provided, this water drift loss from the system can be as higher than 2% - 3% of the total circulation flow rate. Although the drift loss value seems to be small in percentage, but this amount of drift loss is more than sufficient

to keep the cooling tower surroundings wet, causing corrosion problems and health hazards as long as the cooling tower is in operation. And the cost for the total amount of make-up water necessary to top up the system at all time over a long duration can become very significant. The PCF Series cooling towers has the very unique and efficient drift eliminator system installed over the distribution system and below the fan assembly as standard component. The drift eliminator system is capable minimize drift loss to as low as 0.005% of the total circulation flow rate. This ver y small amount of drift loss is vir tually negligible and shall not cause the surrounding area wet or consume excessive water when compare to the amount of water lost due to evaporation.

Access Door
FRP access door is provided for each cell located either at one of the side panel, or on the fan deck as standard feature. Provision of this door allows the maintenance personal to enter into the cooling tower easily without troublesome dismantling of any tower components. This direct access into the distribution and fill media sections encourage regular inspection and cleaning of the fill media and distribution system to maintain efficient tower operation at all time.

Civil Foundation
With the cooling tower being designed with multiple cells flexibility, and made of light weight materials of construction, tower supporting structures are systematically simple, level, symmetrical, easy and economical to construct. And it is always a lot more easily to directly incorporate into the building structure without complicated construction. Since all the loading points are equal distance to each other in both direction, all loading points will eventually aligned into parallel rows of beams. With this characteristic, it is always possible to adjust the seating position of the cooling tower with all its loading points coincide with structural beams. And the supporting beams can be either concrete of steel construction.

Access Ladder
Hot-dip galvanized access ladder is provided for access onto the mechanical equipment for routine inspection and maintenance purpose as standard. For multiple cells model, a common inspection platform in between tower cells complete with safety rails of hot-dip galvanized steel construction is provided as optional item with added cost. This safety platform makes minor maintenance work on top of tower such as checking and replacement of gear oils and tightening of loosened bolts and nuts a lot easier and safer. It also encourages routine inspection and maintenance work on more regular basis since the mechanical equipment requires more attention in order to ensure smooth operation.

Alternatively, the PCF Series towers can be easily installed onto larger concrete cold-water basin with simple supporting columns where much longer retention time of the water storage is necessary. Concrete basin with larger retention volume is recommended for applications whereby make-up water supply is expected to be irregular. And for very critical applications, cooling tower water supply to the plant or equipment cannot be immediately shut off, larger basin to provide emergency water supply is recommended in case make-up water is abruptly being cut off.

PCF SERIES...
4 CELLS COOLING TOWER WITH FRP BASIN

UNIQUE ADVANTAGES
This example illustrate a 4 cells cooling tower of an IN-LINE tower arrangement with each individual cell capacity exactly sized for actual heat rejection load of serving each intremediate cooling equipment such as heat exchanger or chiller. An additional cell is included serving as the standby unit and provision for unexpectedly high heat load, should there be any. Circulation water pumps is similarly sized in accordance to the exact flow rate required by the equipment to be cooled and with an additional pump serving as the standby unit. Return hot water is pump back to the cooling tower via a single header pipe which redistribute the total flow into any individual cell to perform the cooling required. Since the cooling tower is of the single common basin design, discharge piping is directly connected to the circulation pumps from the cold-water basin without the need of a common suction header pipe. Return hot water enter cooling tower by a single header pipe and branched into each cell each with an isolating valve. This method of piping arrangement provides flexibility and simplify the entire cooling system operation by allowing each cooling tower cell, circulation water pumps and cooling equipment to operate independently. It also reduces the unnecessary initial construction cost required to provide balancing pipes and suction header pipes as compared to conventianal design. Since the cooling tower is designed into square shape for each cell, and suitable for multiple cells operation with tower and the cold water basin specifically made from light weight FRP materials, the final overall operating weight is markedly reduced. Therefore, plinths required for the cooling tower does not require elaborate supporting foundation. As such, the cooling tower is suitable for installation on any building floors or elevated structures supported by either simple concrete plinths or structural steel members when space available is limited. It is due to the increasingly challenging needs of every individuals that leads to the development of the PCF Series cooling tower which provide such high degree of flexibility. The advantages of the PCF Series cooling tower such as energy conservation, minimum plot area, low piping and civil construction cost can only be effectively realised if all these associated works are being evaluated initially with different cooling tower of number of cells. It is also for every individual to determine the necessity of any spare or stand-by unit depending on their application. In any case, an additional cell of fractional capacity to the cooling tower is always more economical and easier to operate than an additional full size cooling tower. And similarly, stand-by circulation pump of fractional capacity similar to the circulation flow rate of each cell is only required instead of a full sized stand-by pump.

NOTES:
1. SIMILAR MULTIPLE CELLS ARRANGEMENT IS APPLICABLE TO ANY NUMBER OF CELLS. 2. WATER PUMPS AND PIPING ARRANGEMENT ARE PROVIDED FOR REFERENCE ONLY. CONSULT PANWATER FOR OTHER DIFFERENT ARRANGEMENT. 3. MOTORISED ACTUATED CONTROL VALVES CAN BE USED TO INCORPORATE INTO THE OVERALL CONTROL SYSTEM IN LIEU OF THE MANUAL VALVES. 4. PANWATER RESERVES THE RIGHT TO ALTER ORMODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT

PCF SERIES...
4 CELLS COOLING TOWER WITH CONCRETE BASIN

UNIQUE ADVANTAGES
This example illustrate a 4 cells cooling tower of an IN-LINE tower arrangement seated on a concrete cold water basin which is typical in many industrial cooling system design. The tower is designed to allow the cooling system to operate on partial loads at different stages depending on the requirement to conserve electrical power consumption. The total number of cells required is very much dependent on the mode of operation. In any case, due to the fact that cooling towers are normally designed to cater for the maximum wet bulb temperature foresee in certain period only,it is common that the cooling tower may not be operating at full load at all time. Although providing lower temperature than required to the equipment to be cooled is generally beneficial, but the power consumed by the cooling tower has to be justified. Similarly, any number of water circulation pumps can be incorporate into the cooling system to service various cooling needs without complicated piping works and operation, making the overall system into a flexible central cooling reservoir for all applications within a process plant. Therefore, just a matter of initial careful planning and design of the entire cooling system, tremendous amount of long term energy saving from the cooling tower and the circulation pumps can be realised by employing this unique advantage. Energy saving is usually during period of lower ambient wet bulb temperature at night and/or during colder seasons in the temperate coutries. Although construction of concrete cold water basin is usually at higher cost than the integral FRP basin supplied together with the cooling tower, however, concrete cold water basin offer the advantage of providing a huge amount of water storage for the cooling system. This particularly important for critical applications such as in certain process plant and in cases where make-up water supply is envisaged to be interrupted at any time. Since each cooling tower cell is square, the multiple cells arrangement only requires equally spaced foundation in both ways. This provide the advantage of having all loading positions can be easily designed and constructed onto the basin floors using independent column for each loading point, or using rows of parallel beams as tower supports. In most cases, loadings of the cooling tower is quite minimum due to the lightweight construction, making civil foundation construction quite economical. Alternatively, should cold water basin of larger retention volume is necessary, either for installation above ground level or on elevated structures, cold water basin of any desired volume can be easily constructed from any materials of construction to suit the application ranging from using FRP materials to mild steel construction with corrossion resistant linings or coatings, or using stainless steel materials for long life span.

NOTES:
1. 2. 3. 4. SIMILAR MULTIPLE CELLS ARRANGEMENT IS APPLICABLE TO ANY NUMBER OF CELLS. WATER PUMPS AND PIPING ARRANGEMENT ARE PROVIDED FOR REFERENCE ONLY. CONSULT PANWATER FOR OTHER DIFFERENT ARRANGEMENT. MOTORISED ACTUATED CONTROL VALVES CAN BE USED TO INCORPORATE INTO THE OVERALL CONTROL SYSTEM IN LIEU OF THE MANUAL VALVES. PANWATER RESERVES THE RIGHT TO ALTER ORMODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT

PCF SERIES...
DESIGN CONCEPTS & FEATURES

STANDARD MATERIAL OF CONSTRUCTION


PCF1000 PCF1200 PCF1400 PCF1600 PCF1800 PCF2000 MODELS PCF125 PCF150 PCF175 PCF225 PCF250 PCF350 PCF500 PCF100 PCF200 PCF300 PCF400 PCF600 PCF700 PCF800 PCF900 PCF60 PCF70 PCF80 PCF90 PCF50

Tower Assembly Electric Motor Speed Reducer Drive Shaft Fan Assembly Mechanical Supports Fan Stack Inlet Header Connection Distribution Pipes Spray Nozzles Drift Eliminator Fill Packing Tower Casing Cold Water Basin Tower Structure Tower Hardware Access Ladder
NOTES:
1. 2. 3. 4.

Factory Assembled Direct Motor Drive Not Applicable V-Belt Speed Reducer

Site Assembly 380V/415V, 3 PHASE, 50Hz/60Hz, IP 55 Protection Spiral Bevel Gear Speed Reducer Tubular Floating Shaft

Aluminium Alloy Fan Blades & Hubs Hot Dip Galvanized Steel To B. S. 729:1971 Fiber-Glass Reinforced Polyester PVC JIS 10K Inlet Flange PVC / FRP Polypropylene Cellular PVC Extruded Profiles Modular PVC Fill Media Fiber-Glass Reinforced Polyester Fiber-Glass Reinforced Polyester Fiber-Glass Reinforced Polyester or Concrete Cold Water Basin By Owner Hot Dip Galvanized Steel To B. S. 729:1971 Hot Dip Galvanized Steel To B. S. 729:1971 Not Fitted Hot Dip Galvanized Steel To B. S. 729:1971

UNLESS OTHERWISE SPECIFIED, ELECTRIC MOTOR SUPPLIED SHALL BE 415V, 3 PHASE, 50 HZ AS STANDARDS. MATERIALS OF CONSTRUCTION OTHER THAN SPECIFIED HEREIN CAN BE SUPPLIED WITH ADDED COST ON REQUEST. CONSULT PANWATER FOR TOWER SELECTION, DETAIL SPECIFICATION AND DIMENSIONAL DRAWINGS BY GIVING YOUR REQUIREMENT. PANWATER RESERVES THE RIGHT TO THE SPECIFICATION AND DIMENSIONS WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

10

PCF SERIES...
GENERAL ARRANGEMENT & LAYOUT
MODEL PCF 50 TO PCF 100

ENGINEERING DATA
Tower Model PCF 50-C1 PCF 60-C1 PCF 70-C1 PCF 80-C1 PCF 90-C1 PCF 100-C1 Tower Model PCF 50-C1 PCF 60-C1 PCF 70-C1 PCF 80-C1 PCF 90-C1 PCF 100-C1 Tower Model PCF 50-C1 PCF 60-C1 PCF 70-C1 PCF 80-C1 PCF 90-C1 PCF 100-C1
NOTES:
THERMAL DESIGN CONDITIONS AS PER JIS STANDARDS : CIRCULATING FLOW RATE = 780 LITRES/HOUR PER RT INLET TEMPERATURE = 370 COUTLET TEMPERATURE = 320C WET BULB TEMPERATURE = 270C

Capacity RT 50 60 70 80 90 100 Inlet 80 80 100 100 100 100 L1 1,450 1,450 1,650 1,650 1,850 1,850

Heat Load Kcal / hour 195,000 234,000 273,000 312,000 351,000 390,000 Outlet 80 80 100 100 100 100 L2 1,450 1,450 1,650 1,650 1,850 1,850

Flow Rate m / hour 39 47 55 62 70 78 Auto Make-up 20 20 20 20 20 20 L3 N/A N/A N/A N/A N/A N/A Length, L 1,540 1,540 1,740 1,740 1,940 1,940 Quick Fill 20 20 20 20 20 20 Quantity 4 4 4 4 4 4

Tower Dimension (mm) Width, W 1,540 1,540 1,740 1,740 1,940 1,940 Over Flow 25 25 25 25 25 25 Loading Point 200 205 238 250 300 325 Height, H 2,720 3,020 2,740 3,040 2,920 3,220 Drain 25 25 25 25 25 25

Motor Size Kw 0.75 1.10 1.10 1.50 1.50 2.20 H1 @ Inlet 1,780 2,080 1,780 2,080 1,780 2,080

Fan Diameter mm 915 915 1,068 1,068 1,220 1,220 H2 @ Outlet 115 115 120 120 125 125 Quantity 4 4 4 4 4 4

Air Volume Inlet / Outlet Pump Head M/Min. 288 306 404 409 519 511 D1 N/A N/A N/A N/A N/A N/A Size M12 M12 M12 M12 M12 M12 Pipe Size 3 3 4 4 4 4 D2 N/A N/A N/A N/A N/A N/A Shipping 480 500 540 590 670 780 M 2.8 3.0 2.8 3.0 3.2 3.5 D3 N/A N/A N/A N/A N/A N/A Operating 800 820 950 1,000 1,200 1,300

Piping Connection Size (mm) NB

Vertical Height (mm)

Horizontal Distance (mm)

Center Distance Between Supports (mm)

Loading Data (KGS) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Anchor Bolts

Tower Weight (KGS)

Loading @ A Loading @ B Loading @ C

11

PCF SERIES...
GENERAL ARRANGEMENT & LAYOUT
MODEL PCF 125 TO PCF 225

ENGINEERING DATA
Tower Model PCF 125-C1 PCF 125-C2 PCF 125-C3 PCF 125-C4 PCF 150-C1 PCF 150-C2 PCF 150-C3 PCF 150-C4 PCF 175-C1 PCF 175-C2 PCF 175-C3 PCF 175-C4 PCF 200-C1 PCF 200-C2 PCF 200-C3 PCF 200-C4 PCF 225-C1 PCF 225-C2 PCF 225-C3 PCF 225-C4
NOTES:
1. 2. 3. 4. THE LAST DIGIT OF THE MODEL NUMBER DENOTES NUMBER OF CELLS. CONSULT PANWATER FOR TOWER CONFIGURATION EXCEEDING 4 CELLS. PROVIDE SPACE SURROUNDING THE COOLING TOWER FOR INSTALLATION AND MAINTENANCE ACCESS. AVOID LOCATION TOO NEAR ANY VERTICAL OBSTRUCTIONS. FOR COOLING TOWERS EXCEEDING CONFIGURATIONS NOT SHOWN, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSION DRAWINGS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Capacity RT 125 250 375 500 150 300 450 600 175 350 525 700 200 400 600 800 225 450 675 900

Heat Load Kcal / hour 487,500 975,000 1,462,500 1,950,000 585,000 1,170,000 1,755,000 2,340,000 682,500 1,365,000 2,047,500 2,730,000 780,000 1,560,000 2,340,000 3,120,000 877,500 1,755,000 2,632,500 3,510,000

Flow Rate m3 / hour 98 195 293 390 117 234 351 468 137 273 410 546 156 312 468 624 176 351 527 702 Length, L 2,380 4,720 7,060 9,400 2,380 4,720 7,060 9,400 2,640 5,240 7,840 10,440 2,640 5,240 7,840 10,440 2,840 5,640 8,440 11,240

Tower Dimension (mm) Width, W 2,380 2,380 2,380 2,380 2,380 2,380 2,380 2,380 2,640 2,640 2,640 2,640 2,640 2,640 2,640 2,640 2,840 2,840 2,840 2,840 Height, H1 3,610 3,730 3,990 3,990 3,910 4,030 4,290 4,290 3,750 3,880 4,170 4,170 4,050 4,180 4,470 4,470 3,780 3,920 4,240 4,240 Height, H2 2,960 3,080 3,340 3,340 3,260 3,380 3,640 3,640 3,100 3,230 3,520 3,520 3,400 3,530 3,820 3,820 3,130 3,270 3,590 3,590

Motor Size Fan Diameter Air Volume Inlet / Outlet Pump Head Kw 2.20 2.2 X 2 2.2 X 3 2.2 X 4 3.00 3.0 X 2 3.0 X 3 3.0 X 4 4.00 4.0 X 2 4.0 X 3 4.0 X 4 5.50 5.5 X 2 5.5 X 3 5.5 X 4 5.50 5.5 X 2 5.5 X 3 5.5 X 4 mm 1,373 1,373 1,373 1,373 1,373 1,373 1,373 1,373 1,525 1,525 1,525 1,525 1,525 1,525 1,525 1,525 1,830 1,830 1,830 1,830 M3/Min. 721 721 721 721 766 766 766 766 1,009 1,009 1,009 1,009 1,021 1,021 1,021 1,021 1,298 1,298 1,298 1,298 Pipe Size 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 M 3.7 3.9 4.1 4.1 4.0 4.2 4.4 4.4 3.8 3.9 4.2 4.2 4.1 4.2 4.5 4.5 3.8 3.9 4.2 4.2

12

PCF SERIES...
EXTERNAL PIPING LAYOUT
MODEL PCF 125 TO PCF 225

EXTERNAL PIPING DATA


Tower Model PCF 125-C1 PCF 125-C2 PCF 125-C3 PCF 125-C4 PCF 150-C1 PCF 150-C2 PCF 150-C3 PCF 150-C4 PCF 175-C1 PCF 175-C2 PCF 175-C3 PCF 175-C4 PCF 200-C1 PCF 200-C2 PCF 200-C3 PCF 200-C4 PCF 225-C1 PCF 225-C2 PCF 225-C3 PCF 225-C4
NOTES:
1. 2. 3. 4. ALL INLET AND OUTLET CONNECTIONS SHALL BE FLANGED TO JIS 10K AS STANDARD. CUSTOMER TO PROVIDE ALL NECESSARY EXTERNAL PIPE SUPPORTS FOR ALL INTER-CONNECTING WATER PIPES. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Piping Connection Size (mm) NB @ Cold Water Basin Inlet 125 125 125 125 125 125 125 125 150 150 150 150 150 150 150 150 150 150 150 150 Outlet 125 125 125 125 125 125 125 125 150 150 150 150 150 150 150 150 150 150 150 150 Auto Make-up 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 Quick Fill 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 Over Flow 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 65 65 Drain 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 65 65 R1 @ Inlet 2,230 2,350 2,580 2,580 2,530 2,650 2,880 2,880 2,270 2,400 2,660 2,660 2,570 2,700 3,000 3,000 2,300 2,440 2,720 2,720

Vertical Height (mm) R2 @ Inlet 1,580 1,700 1,930 1,930 1,880 2,000 2,230 2,230 1,620 1,750 2,010 2,010 1,920 2,050 2,350 2,350 1,650 1,790 2,070 2,070 D @ Outlet 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 L1 1,755 1,755 1,755 1,755 1,755 1,755 1,755 1,755 1,950 1,950 1,950 1,950 1,950 1,950 1,950 1,950 2,100 2,100 2,100 2,100

Horizontal Distance (mm) L2 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,800 2,800 2,800 2,800 L3 585 585 585 585 585 585 585 585 650 650 650 650 650 650 650 650 700 700 700 700

13

PCF SERIES...
TOWER FOUNDATION LAYOUT
MODEL PCF 125 TO PCF 225

TOWER FOUNDATION DIMENSION


Tower Model PCF 125-C1 PCF 125-C2 PCF 125-C3 PCF 125-C4 PCF 150-C1 PCF 150-C2 PCF 150-C3 PCF 150-C4 PCF 175-C1 PCF 175-C2 PCF 175-C3 PCF 175-C4 PCF 200-C1 PCF 200-C2 PCF 200-C3 PCF 200-C4 PCF 225-C1 PCF 225-C2 PCF 225-C3 PCF 225-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOUNDATION HEIGHT INDICATED IS MINIMUM REQUIREMENT. INCREASE THE HIGHT IF NECESSARY TO SUIT PIPING INSTALLATION. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 2,340 4,680 7,020 9,360 2,340 4,680 7,020 9,360 2,600 5,200 7,800 10,400 2,600 5,200 7,800 10,400 2,800 5,600 8,400 11,200 L2 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,800 2,800 2,800 2,800 L3 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,300 1,300 1,300 1,300 1,300 1,300 1,300 1,300 1,400 1,400 1,400 1,400 Quantity 4 6 8 10 4 6 8 10 9 15 21 27 9 15 21 27 9 15 21 27 223 220 219 219 233 229 228 228 268 264 263 263 278 274 273 272 300 296 295 294

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 372 367 366 365 388 382 380 379 447 441 439 438 463 456 454 453 500 494 492 491 595 588 585 584 620 611 608 607 715 705 702 700 740 730 727 725 800 790 787 785

Anchor Bolts Quantity 4 6 8 10 4 6 8 10 12 20 28 36 12 20 28 36 12 20 28 36 Size M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12

Tower Weight (KGS) Shipping 1,290 2,520 3,750 4,980 1,380 2,690 4,000 5,310 1,510 2,940 4,370 5,800 1,610 3,140 4,670 6,200 1,620 3,160 4,700 6,240 Operating 2,380 4,700 7,020 9,340 2,480 4,890 7,300 9,710 2,860 5,640 8,420 11,200 2,960 5,840 8,720 11,600 3,200 6,320 9,440 12,560

14

PCF SERIES...
CONCRETE BASIN LAYOUT
MODEL PCF 125 TO PCF 225

CONCRETE BASIN DIMENSION


Tower Model PCF 125-C1 PCF 125-C2 PCF 125-C3 PCF 125-C4 PCF 150-C1 PCF 150-C2 PCF 150-C3 PCF 150-C4 PCF 175-C1 PCF 175-C2 PCF 175-C3 PCF 175-C4 PCF 200-C1 PCF 200-C2 PCF 200-C3 PCF 200-C4 PCF 225-C1 PCF 225-C2 PCF 225-C3 PCF 225-C4
NOTES:
1. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. 2. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. 3. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. 4. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 2,340 4,680 7,020 9,360 2,340 4,680 7,020 9,360 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,800 2,800 2,800 2,800 L2 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,340 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,600 2,800 2,800 2,800 2,800 L3 N/A N/A N/A N/A N/A N/A N/A N/A 1,300 1,300 1,300 1,300 1,300 1,300 1,300 1,300 1,400 1,400 1,400 1,400 Quantity 4 6 8 10 4 6 8 10 9 15 21 27 9 15 21 27 9 15 21 27 Loading @ A 150 141 144 143 159 155 150 150 178 216 231 239 188 230 241 248 206 244 259 267

Loading Data (KGS) Loading @ B 250 234 240 238 266 258 250 250 297 359 385 398 313 383 401 414 344 406 432 445 Loading @ C 400 375 383 381 425 413 400 400 475 575 617 638 500 613 642 663 550 650 692 713

Anchor Bolts Quantity 4 6 8 10 4 6 8 10 12 20 28 36 12 20 28 36 12 20 28 36 Size M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12

Tower Weight (KGS) Shipping 1,300 2,600 3,900 5,200 1,400 2,800 4,200 5,600 1,500 3,000 4,500 6,000 1,600 3,200 4,800 6,400 1,650 3,300 4,950 6,600 Operating 1,600 3,000 4,600 6,100 1,700 3,300 4,800 6,400 1,900 4,600 7,400 10,200 2,000 4,900 7,700 10,600 2,200 5,200 8,300 11,400

15

PCF SERIES...
GENERAL ARRANGEMENT & LAYOUT
MODEL PCF 250 TO PCF 500

ENGINEERING DATA
Tower Model PCF 250-C1 PCF 250-C2 PCF 250-C3 PCF 250-C4 PCF 300-C1 PCF 300-C2 PCF 300-C3 PCF 300-C4 PCF 350-C1 PCF 350-C2 PCF 350-C3 PCF 350-C4 PCF 400-C1 PCF 400-C2 PCF 400-C3 PCF 400-C4 PCF 500-C1 PCF 500-C2 PCF 500-C3 PCF 500-C4 Capacity RT 250 500 750 1,000 300 600 900 1,200 350 700 1,050 1,400 400 800 1,200 1,600 500 1,000 1,500 2,000 Heat Load Kcal / hour 975,000 1,950,000 2,925,000 3,900,000 1,170,000 2,340,000 3,510,000 4,680,000 1,365,000 2,730,000 4,095,000 5,460,000 1,560,000 3,120,000 4,680,000 6,240,000 1,950,000 3,900,000 5,850,000 7,800,000 Flow Rate m3 / hour 195 390 585 780 234 468 702 936 273 546 819 1,092 312 624 936 1,248 390 780 1,170 1,560 Length, L 2,840 5,640 8,440 11,240 3,240 6,440 9,640 12,840 3,440 6,840 10,240 13,640 3,640 7,240 10,840 14,440 4,040 8,040 12,040 16,040 Tower Dimension (mm) Width, W 2,840 2,840 2,840 2,840 3,240 3,240 3,240 3,240 3,440 3,440 3,440 3,440 3,640 3,640 3,640 3,640 4,040 4,040 4,040 4,040 Height, H1 4,130 4,270 4,540 4,540 4,190 4,350 4,710 4,710 4,310 4,480 4,860 4,860 4,700 4,880 5,290 5,290 4,960 5,160 5,610 5,610 Height, H2 3,430 3,570 3,840 3,840 3,490 3,650 4,010 4,010 3,560 3,730 4,110 4,110 3,950 4,130 4,540 4,540 4,160 4,360 4,810 4,810 Motor Size Fan Diameter Air Volum Inlet/Outlet Pump Head Kw 5.50 5.5 X 2 5.5 X 3 5.5 X 4 7.50 7.5 X 2 7.5 X 3 7.5 X 4 7.50 7.5 X 2 7.5 X 3 7.5 X 4 11.00 11.0 X 2 11.0 X 3 11.0 X 4 11.00 11.0 X 2 11.0 X 3 11.0 X 4 mm 1,830 1,830 1,830 1,830 2,135 2,135 2,135 2,135 2,135 2,135 2,135 2,135 2,440 2,440 2,440 2,440 2,440 2,440 2,440 2,440 M3/Min. 1,277 1,277 1,277 1,277 1,532 1,532 1,532 1,532 1,787 1,787 1,787 1,787 2,043 2,043 2,043 2,043 2,553 2,553 2,553 2,553 Pipe Size 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 M 4.2 4.3 4.6 4.6 4.2 4.4 4.7 4.7 4.3 4.5 4.8 4.8 4.3 4.5 4.9 4.9 4.4 4.6 5.0 5.0

NOTES: THERMAL DESIGN CONDITIONS AS PER JIS STANDARDS :


1. THE LAST DIGIT OF THE MODEL NUMBER DENOTES NUMBER OF CELLS. CONSULT PANWATER FOR TOWER CONFIGURATION EXCEEDING 4 CELLS.CIRCULATING FLOW RATE = 780 LITRES/HOUR PER RT 2. PROVIDE SPACE SURROUNDING THE COOLING TOWER FOR INSTALLATION AND MAINTENANCE ACCESS. AVOID LOCATION TOO NEAR ANY VERTICAL OBSTRUCTIONS. INLET TEMPERATURE = 37 C 3. FOR COOLING TOWERS EXCEEDING CONFIGURATIONS NOT SHOWN, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSION DRAWINGS.OUTLET TEMPERATURE = 32 C 4. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.WET BULB TEMPERATURE = 27C

16

PCF SERIES...
EXTERNAL PIPING LAYOUT
MODEL PCF 250 TO PCF 500

EXTERNAL PIPING DATA


Tower Model PCF 250-C1 PCF 250-C2 PCF 250-C3 PCF 250-C4 PCF 300-C1 PCF 300-C2 PCF 300-C3 PCF 300-C4 PCF 350-C1 PCF 350-C2 PCF 350-C3 PCF 350-C4 PCF 400-C1 PCF 400-C2 PCF 400-C3 PCF 400-C4 PCF 500-C1 PCF 500-C2 PCF 500-C3 PCF 500-C4
NOTES:
1. 2. 3. 4. ALL INLET AND OUTLET CONNECTIONS SHALL BE FLANGED TO JIS 10K AS STANDARD. CUSTOMER TO PROVIDE ALL NECESSARY EXTERNAL PIPE SUPPORTS FOR ALL INTER-CONNECTING WATER PIPES. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Piping Connection Size (mm) NB @ Cold Water Basin Inlet 150 150 150 150 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 Outlet 150 150 150 150 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 Auto Make-up 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 Quick Fill 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 Over Flow 65 65 65 65 80 80 80 80 80 80 80 80 80 80 80 80 100 100 100 100 Drain 65 65 65 65 80 80 80 80 80 80 80 80 80 80 80 80 100 100 100 100 R1 @ Inlet 2,650 2,790 3,070 3,070 2,710 2,870 3,190 3,190 2,790 2,960 3,300 3,300 2,820 3,000 3,360 3,360 2,930 3,130 3,530 3,530

Vertical Height (mm) R2 @ Inlet 1,950 2,090 2,370 2,370 2,010 2,170 2,490 2,490 2,040 2,210 2,550 2,550 2,070 2,250 2,610 2,610 2,130 2,330 2,730 2,730 D @ Outlet 215 215 215 215 215 215 215 215 265 265 265 265 265 265 265 265 250 250 250 250 L1

Horizontal Distance (mm) L2 2,800 2,800 2,800 2,800 3,200 3,200 3,200 3,200 3,400 3,400 3,400 3,400 3,600 3,600 3,600 3,600 4,000 4,000 4,000 4,000 L3 700 700 700 700 800 800 800 800 850 850 850 850 900 900 900 900 1,000 1,000 1,000 1,000 2,100 2,100 2,100 2,100 2,400 2,400 2,400 2,400 2,550 2,550 2,550 2,550 2,700 2,700 2,700 2,700 3,000 3,000 3,000 3,000

17

PCF SERIES...
TOWER FOUNDATION LAYOUT
MODEL PCF 250 TO PCF 500

TOWER FOUNDATION DIMENSION


Tower Model PCF 250-C1 PCF 250-C2 PCF 250-C3 PCF 250-C4 PCF 300-C1 PCF 300-C2 PCF 300-C3 PCF 300-C4 PCF 350-C1 PCF 350-C2 PCF 350-C3 PCF 350-C4 PCF 400-C1 PCF 400-C2 PCF 400-C3 PCF 400-C4 PCF 500-C1 PCF 500-C2 PCF 500-C3 PCF 500-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOUNDATION HEIGHT INDICATED IS MINIMUM REQUIREMENT. INCREASE THE HIGHT IF NECESSARY TO SUIT PIPING INSTALLATION. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 2,800 5,600 8,400 11,200 3,200 6,400 9,600 12,800 3,400 6,800 10,200 13,600 3,600 7,200 10,800 14,400 4,000 8,000 12,000 16,000 L2 2,800 2,800 2,800 2,800 3,200 3,200 3,200 3,200 3,400 3,400 3,400 3,400 3,600 3,600 3,600 3,600 4,000 4,000 4,000 4,000 L3 1,400 1,400 1,400 1,400 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 2,000 2,000 2,000 2,000 Quantity 9 15 21 27 9 15 21 27 9 15 21 27 9 15 21 27 9 15 21 27 309 309 306 305 384 380 381 380 441 436 434 436 478 473 472 471 572 567 566 565

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 516 516 510 508 641 633 635 633 734 727 724 727 797 789 786 785 953 945 943 941 825 825 817 813 1,025 1,013 1,017 1,013 1,175 1,164 1,158 1,163 1,275 1,263 1,258 1,256 1,525 1,513 1,508 1,506

Anchor Bolts Quantity 12 20 28 36 12 20 28 36 12 20 28 36 12 20 28 36 12 20 28 36 Size M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12

Tower Weight (KGS) Shipping 1,800 3,600 5,300 7,000 2,100 4,100 6,200 8,200 2,400 4,710 7,000 9,400 2,600 5,100 7,600 10,100 2,900 5,700 8,500 11,300 Operating 3,300 6,600 9,800 13,000 4,100 8,100 12,200 16,200 4,700 9,310 13,900 18,600 5,100 10,100 15,100 20,100 6,100 12,100 18,100 24,100

18

PCF SERIES...
CONCRETE BASIN LAYOUT
MODEL PCF 250 TO PCF 500

CONCRETE BASIN DIMENSION


Tower Model PCF 250-C1 PCF 250-C2 PCF 250-C3 PCF 250-C4 PCF 300-C1 PCF 300-C2 PCF 300-C3 PCF 300-C4 PCF 350-C1 PCF 350-C2 PCF 350-C3 PCF 350-C4 PCF 400-C1 PCF 400-C2 PCF 400-C3 PCF 400-C4 PCF 500-C1 PCF 500-C2 PCF 500-C3 PCF 500-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 2,800 5,600 8,400 11,200 3,200 6,400 9,600 12,800 3,400 6,800 10,200 13,600 3,600 7,200 10,800 14,400 4,000 8,000 12,000 16,000 L2 2,800 2,800 2,800 2,800 3,200 3,200 3,200 3,200 3,400 3,400 3,400 3,400 3,600 3,600 3,600 3,600 4,000 4,000 4,000 4,000 L3 1,400 1,400 1,400 1,400 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 2,000 2,000 2,000 2,000 Quantity 9 15 21 27 9 15 21 27 9 15 21 27 9 15 21 27 9 15 21 27 197 197 194 192 244 239 241 239 272 267 269 267 300 295 294 295 347 342 341 340

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 328 328 323 320 406 398 401 398 453 445 448 445 500 492 490 492 578 570 568 566 525 525 517 513 650 638 642 638 725 713 717 713 800 788 783 788 925 913 908 906

Anchor Bolts Quantity 12 20 28 36 12 20 28 36 12 20 28 36 12 20 28 36 12 20 28 36 Size M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12

Tower Weight (KGS) Shipping 1,700 3,400 5,000 6,600 2,000 3,900 5,900 7,800 2,200 4,300 6,500 8,600 2,400 4,700 7,000 9,400 2,700 5,300 7,900 10,500 Operating 2,100 4,200 6,200 8,200 2,600 5,100 7,700 10,200 2,900 5,700 8,600 11,400 3,200 6,300 9,400 12,600 3,700 7,300 10,900 14,500

19

PCF SERIES...
GENERAL ARRANGEMENT & LAYOUT
MODEL PCF 600 TO PCF 1000

ENGINEERING DATA
Tower Model PCF 600-C1 PCF 600-C2 PCF 600-C3 PCF 600-C4 PCF 700-C1 PCF 700-C2 PCF 700-C3 PCF 700-C4 PCF 800-C1 PCF 800-C2 PCF 800-C3 PCF 800-C4 PCF 900-C1 PCF 900-C2 PCF 900-C3 PCF 900-C4 PCF 1000-C1 PCF 1000-C2 PCF 1000-C3 PCF 1000-C4
NOTES:
1. 2. 3. 4. THE LAST DIGIT OF THE MODEL NUMBER DENOTES NUMBER OF CELLS. CONSULT PANWATER FOR TOWER CONFIGURATION EXCEEDING 4 CELLS. PROVIDE SPACE SURROUNDING THE COOLING TOWER FOR INSTALLATION AND MAINTENANCE ACCESS. AVOID LOCATION TOO NEAR ANY VERTICAL OBSTRUCTIONS. FOR COOLING TOWERS EXCEEDING CONFIGURATIONS NOT SHOWN, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSION DRAWINGS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Capacity RT 600 1,200 1,800 2,400 700 1,400 2,100 2,800 800 1,600 2,400 3,200 900 1,800 2,700 3,600 1,000 2,000 3,000 4,000

Heat Load Kcal / hour 2,340,000 4,680,000 7,020,000 9,360,000 2,730,000 5,460,000 8,190,000 10,920,000 3,120,000 6,240,000 9,360,000 12,480,000 3,510,000 7,020,000 10,530,000 14,040,000 3,900,000 7,800,000 11,700,000 15,600,000

Flow Rate m3 / hour 468 936 1,404 1,872 546 1,092 1,638 2,184 624 1,248 1,872 2,496 702 1,404 2,106 2,808 780 1,560 2,340 3,120 Length, L 4,540 9,040 13,540 18,040 4,840 9,640 14,440 19,240 5,140 10,240 15,340 20,440 5,440 10,840 16,240 21,640 5,740 11,440 17,140 22,840

Tower Dimension (mm) Width, W 4,540 4,540 4,540 4,540 4,840 4,840 4,840 4,840 5,140 5,140 5,140 5,140 5,440 5,440 5,440 5,440 5,740 5,740 5,740 5,740 Height, H1 5,860 6,080 6,530 6,530 5,860 6,080 6,530 6,530 5,870 6,120 6,670 6,670 5,940 6,120 6,750 6,750 5,980 6,270 6,840 6,840 Height, H2 5,060 5,280 5,730 5,730 5,060 5,280 5,730 5,730 5,070 5,320 5,870 5,870 5,140 5,410 5,950 5,950 5,180 5,470 6,040 6,040

Motor Size Kw 15.00 15.0 X 2 15.0 X 3 15.0 X 4 18.50 18.5 X 2 18.5 X 3 18.5 X 4 18.50 18.5 X 2 18.5 X 3 18.5 X 4 22.50 22.5 X 2 22.5 X 3 22.5 X 4 22.50 22.5 X 2 22.5 X 3 22.5 X 4

Fan Size mm 2,745 2,745 2,745 2,745 2,745 2,745 2,745 2,745 3,050 3,050 3,050 3,050 3,350 3,350 3,350 3,350 3,350 3,350 3,350 3,350

Air Volume Inlet/Outlet Pump Head M3/Min. 3,064 3,064 3,064 3,064 3,574 3,574 3,574 3,574 4,085 4,085 4,085 4,085 4,596 4,596 4,596 4,596 5,106 5,106 5,106 5,106 Pipe Size 10 10 10 10 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 M 4.7 4.9 5.3 5.3 4.7 4.9 5.2 5.2 4.7 5.0 5.5 5.5 4.8 5.1 5.6 5.6 4.8 5.1 5.7 5.7

20

PCF SERIES...
EXTERNAL PIPING LAYOUT
MODEL PCF 600 TO PCF 1000

EXTERNAL PIPING DATA


Tower Model PCF 600-C1 PCF 600-C2 PCF 600-C3 PCF 600-C4 PCF 700-C1 PCF 700-C2 PCF 700-C3 PCF 700-C4 PCF 800-C1 PCF 800-C2 PCF 800-C3 PCF 800-C4 PCF 900-C1 PCF 900-C2 PCF 900-C3 PCF 900-C4 PCF 1000-C1 PCF 1000-C2 PCF 1000-C3 PCF 1000-C4
NOTES:
1. 2. 3. 4. ALL INLET AND OUTLET CONNECTIONS SHALL BE FLANGED TO JIS 10K AS STANDARD. CUSTOMER TO PROVIDE ALL NECESSARY EXTERNAL PIPE SUPPORTS FOR ALL INTER-CONNECTING WATER PIPES. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Piping Connection Size (mm) NB @ Cold Water Basin Inlet 250 250 250 250 250 250 250 250 250 250 250 250 300 300 300 300 300 300 300 300 Outlet 250 250 250 250 250 250 250 250 250 250 250 250 300 300 300 300 300 300 300 300 Auto Make-up 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Quick Fill 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Over Flow 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Drain 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 R1 @ Inlet 3,150 3,370 3,820 3,820 3,200 3,430 3,680 3,680 3,240 3,490 4,000 4,000 3,280 3,550 4,090 4,090 3,330 3,610 4,180 4,180

Vertical Height (mm) R2 @ Inlet 2,350 2,570 3,020 3,020 2,400 2,630 2,880 2,880 2,440 2,690 3,200 3,200 2,480 2,750 3,290 3,290 2,530 2,810 3,380 3,380 D @ Outlet 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250

Horizontal Distance (mm) L1 2,250 2,250 2,250 2,250 2,400 2,400 2,400 2,400 2,550 2,550 2,550 2,550 2,700 2,700 2,700 2,700 2,850 2,850 2,850 2,850 L2 4,500 4,500 4,500 4,500 4,800 4,800 4,800 4,800 5,100 5,100 5,100 5,100 5,400 5,400 5,400 5,400 5,700 5,700 5,700 5,700 L3 2,250 2,250 2,250 2,250 2,400 2,400 2,400 2,400 2,550 2,550 2,550 2,550 2,700 2,700 2,700 2,700 2,850 2,850 2,850 2,850

21

PCF SERIES...
TOWER FOUNDATION & LAYOUT
MODEL PCF 600 TO PCF 1000

TOWER FOUNDATION DIMENSION


Tower Model PCF 600-C1 PCF 600-C2 PCF 600-C3 PCF 600-C4 PCF 700-C1 PCF 700-C2 PCF 700-C3 PCF 700-C4 PCF 800-C1 PCF 800-C2 PCF 800-C3 PCF 800-C4 PCF 900-C1 PCF 900-C2 PCF 900-C3 PCF 900-C4 PCF 1000-C1 PCF 1000-C2 PCF 1000-C3 PCF 1000-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOUNDATION HEIGHT INDICATED IS MINIMUM REQUIREMENT. INCREASE THE HIGHT IF NECESSARY TO SUIT PIPING INSTALLATION. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 4,500 9,000 13,500 18,000 4,800 9,600 14,400 19,200 5,100 10,200 15,300 20,400 5,400 10,800 16,200 21,600 5,700 11,400 17,100 22,800 L2 4,500 4,500 4,500 4,500 4,800 4,800 4,800 4,800 5,100 5,100 5,100 5,100 5,400 5,400 5,400 5,400 5,700 5,700 5,700 5,700 L3 1,500 1,500 1,500 1,500 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 1,900 1,900 1,900 1,900 Quantity 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 308 306 306 304 350 348 346 346 388 385 383 383 421 419 417 416 454 450 450 449

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 514 510 509 507 583 580 576 576 646 642 639 639 701 698 694 693 757 750 750 748 822 817 815 811 933 928 922 922 1,033 1,028 1,022 1,022 1,122 1,117 1,111 1,108 1,211 1,200 1,200 1,197

Anchor Bolts Quantity 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 Size M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

Tower Weight (KGS) Shipping 3,800 7,500 11,200 14,800 4,300 8,500 12,600 16,800 4,600 9,100 13,500 18,000 5,000 9,900 14,700 19,500 5,200 10,200 15,300 20,300 Operating 7,400 14,700 22,000 29,200 8,400 16,700 24,900 33,200 9,300 18,500 27,600 36,800 10,100 20,100 30,000 39,900 10,900 21,600 32,400 43,100

22

PCF SERIES...
CONCRETE BASIN LAYOUT
MODEL PCF 600 TO PCF 1000

CONCRETE BASIN DIMENSION


Tower Model PCF 600-C1 PCF 600-C2 PCF 600-C3 PCF 600-C4 PCF 700-C1 PCF 700-C2 PCF 700-C3 PCF 700-C4 PCF 800-C1 PCF 800-C2 PCF 800-C3 PCF 800-C4 PCF 900-C1 PCF 900-C2 PCF 900-C3 PCF 900-C4 PCF 1000-C1 PCF 1000-C2 PCF 1000-C3 PCF 1000-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 4,500 9,000 13,500 18,000 4,800 9,600 14,400 19,200 5,100 10,200 15,300 20,400 5,400 10,800 16,200 21,600 5,700 11,400 17,100 22,800 L2 4,500 4,500 4,500 4,500 4,800 4,800 4,800 4,800 5,100 5,100 5,100 5,100 5,400 5,400 5,400 5,400 5,700 5,700 5,700 5,700 L3 1,500 1,500 1,500 1,500 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 1,900 1,900 1,900 1,900 Quantity 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 183 181 181 180 204 202 200 200 225 223 221 221 242 235 235 235 250 248 244 245

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 306 302 301 300 340 337 333 333 375 372 368 368 403 392 392 392 417 413 407 408 489 483 481 481 544 539 533 533 600 594 589 589 644 628 628 628 667 661 652 653

Anchor Bolts Quantity 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 16 28 40 52 Size M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

Tower Weight (KGS) Shipping 3,500 6,900 10,300 13,700 4,000 7,900 11,700 15,600 4,300 8,500 12,600 16,800 4,650 9,000 13,500 18,000 4,800 9,500 14,000 18,700 Operating 4,400 8,700 13,000 17,300 4,900 9,700 14,400 19,200 5,400 10,700 15,900 21,200 5,800 11,300 16,950 22,600 6,000 11,900 17,600 23,500

23

PCF SERIES...
GENERAL ARRANGEMENT & LAYOUT
MODEL PCF 1200 TO PCF 2000

ENGINEERING DATA
Tower Model PCF 1200-C1 PCF 1200-C2 PCF 1200-C3 PCF 1200-C4 PCF 1400-C1 PCF 1400-C2 PCF 1400-C3 PCF 1400-C4 PCF 1600-C1 PCF 1600-C2 PCF 1600-C3 PCF 1600-C4 PCF 1800-C1 PCF 1800-C2 PCF 1800-C3 PCF 1800-C4 PCF 2000-C1 PCF 2000-C2 PCF 2000-C3 PCF 2000-C4
NOTES:
1. 2. 3. 4. THE LAST DIGIT OF THE MODEL NUMBER DENOTES NUMBER OF CELLS. CONSULT PANWATER FOR TOWER CONFIGURATION EXCEEDING 4 CELLS. PROVIDE SPACE SURROUNDING THE COOLING TOWER FOR INSTALLATION AND MAINTENANCE ACCESS. AVOID LOCATION TOO NEAR ANY VERTICAL OBSTRUCTIONS. FOR COOLING TOWERS EXCEEDING CONFIGURATIONS NOT SHOWN, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSION DRAWINGS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Capacity RT 1,200 2,400 3,600 4,800 1,400 2,800 4,200 5,600 1,600 3,200 4,800 6,400 1,800 3,600 5,400 7,200 2,000 4,000 6,000 8,000

Heat Load Kcal / hour 4,680,000 9,360,000 14,040,000 18,720,000 5,460,000 10,920,000 16,380,000 21,840,000 6,240,000 12,480,000 18,720,000 24,960,000 7,020,000 14,040,000 21,060,000 28,080,000 7,800,000 15,600,000 23,400,000 31,200,000

Flow Rate m3 / hour 936 1,872 2,808 3,744 1,092 2,184 3,276 4,368 1,248 2,496 3,744 4,992 1,404 2,808 4,212 5,616 1,560 3,120 4,680 6,240 Length, L 6,440 12,840 19,240 25,640 6,840 13,640 20,440 27,240 7,240 14,440 21,640 28,840 7,640 15,240 22,840 30,440 8,040 16,040 24,040 32,040

Tower Dimension (mm) Width, W 6,440 6,440 6,440 6,440 6,840 6,840 6,840 6,840 7,240 7,240 7,240 7,240 7,640 7,640 7,640 7,640 8,040 8,040 8,040 8,040 Height, H1 Height, H2 6,230 6,580 7,280 7,280 6,780 7,180 7,880 7,880 6,850 7,240 8,020 8,020 6,930 7,330 8,150 8,150 6,980 7,430 8,280 8,280 5,930 6,280 6,980 6,980 6,480 6,880 7,580 7,580 6,550 6,940 7,720 7,720 6,630 7,030 7,850 7,850 6,680 7,130 7,980 7,980

Motor Size Fan Diameter Air Volume Inlet / Outlet Pump Head Kw 30.00 30.0 X 2 30.0 X 3 30.0 X 4 30.00 30.0 X 2 30.0 X 3 30.0 X 4 37.00 37.0 X 2 37.0 X 3 37.0 X 4 37.00 37.0 X 2 37.0 X 3 37.0 X 4 45.00 45.0 X 2 45.0 X 3 45.0 X 4 mm 3,660 3,660 3,660 3,660 3,960 3,960 3,960 3,960 4,270 4,270 4,270 4,270 4,570 4,570 4,570 4,570 4,880 4,880 4,880 4,880 M3/Min. 6,128 6,128 6,128 6,128 7,149 7,149 7,149 7,149 8,170 8,170 8,170 8,170 9,191 9,191 9,191 9,191 10,213 10,213 10,213 10,213 Pipe Size 14 14 14 14 14 14 14 14 16 16 16 16 16 16 16 16 18 18 18 18 M 4.4 4.8 5.4 5.4 4.5 4.8 5.5 5.5 4.6 4.9 5.6 5.6 4.6 5.0 5.8 5.8 4.7 5.1 5.9 5.9

24

PCF SERIES...
EXTERNAL PIPING LAYOUT
MODEL PCF 1200 TO PCF 2000

EXTERNAL PIPING DATA


Tower Model PCF 1200-C1 PCF 1200-C2 PCF 1200-C3 PCF 1200-C4 PCF 1400-C1 PCF 1400-C2 PCF 1400-C3 PCF 1400-C4 PCF 1600-C1 PCF 1600-C2 PCF 1600-C3 PCF 1600-C4 PCF 1800-C1 PCF 1800-C2 PCF 1800-C3 PCF 1800-C4 PCF 2000-C1 PCF 2000-C2 PCF 2000-C3 PCF 2000-C4
NOTES:
1. 2. 3. 4. ALL INLET AND OUTLET CONNECTIONS SHALL BE FLANGED TO JIS 10K AS STANDARD. CUSTOMER TO PROVIDE ALL NECESSARY EXTERNAL PIPE SUPPORTS FOR ALL INTER-CONNECTING WATER PIPES. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Piping Connection Size (mm) NB @ Cold Water Basin Inlet 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 450 Outlet 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 450 Auto Make-up Quick Fill 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80 80 80 80 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80 80 80 80 Over Flow 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 Drain 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 R1 @ Inlet 2,930 3,250 3,890 3,890 2,990 3,330 4,010 4,010 3,050 3,410 4,130 4,130 3,110 3,490 4,250 4,250 3,170 3,570 4,370 4,370

Vertical Height (mm) R2 @ Inlet 2,630 2,950 3,590 3,590 2,690 3,030 3,710 3,710 2,750 3,110 3,830 3,830 2,810 3,190 3,950 3,950 2,870 3,270 4,070 4,070 D @ Outlet 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 390 L1

Horizontal Distance (mm) L2 6,400 6,400 6,400 6,400 6,800 6,800 6,800 6,800 7,200 7,200 7,200 7,200 7,600 7,600 7,600 7,600 8,000 8,000 8,000 8,000 L3 800 800 800 800 850 850 850 850 900 900 900 900 950 950 950 950 1,000 1,000 1,000 1,000 5,600 5,600 5,600 5,600 5,950 5,950 5,950 5,950 6,300 6,300 6,300 6,300 6,650 6,650 6,650 6,650 7,000 7,000 7,000 7,000

25

PCF SERIES...
TOWER FOUNDATION LAYOUT
MODEL PCF 1200 TO PCF 2000

TOWER FOUNDATION DIMENSION


Tower Model PCF 1200-C1 PCF 1200-C2 PCF 1200-C3 PCF 1200-C4 PCF 1400-C1 PCF 1400-C2 PCF 1400-C3 PCF 1400-C4 PCF 1600-C1 PCF 1600-C2 PCF 1600-C3 PCF 1600-C4 PCF 1800-C1 PCF 1800-C2 PCF 1800-C3 PCF 1800-C4 PCF 2000-C1 PCF 2000-C2 PCF 2000-C3 PCF 2000-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOUNDATION HEIGHT INDICATED IS MINIMUM REQUIREMENT. INCREASE THE HIGHT IF NECESSARY TO SUIT PIPING INSTALLATION. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 6,400 12,800 19,200 25,600 6,800 13,600 20,400 27,200 7,200 14,400 21,600 28,800 7,600 15,200 22,800 30,400 8,000 16,000 24,000 32,000 L2 6,400 6,400 6,400 6,400 6,800 6,800 6,800 6,800 7,200 7,200 7,200 7,200 7,600 7,600 7,600 7,600 8,000 8,000 8,000 8,000 L3 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 1,900 1,900 1,900 1,900 2,000 2,000 2,000 2,000 Quantity 25 45 65 85 25 45 65 85 25 45 65 85 25 45 65 85 25 45 65 85 314 312 311 310 352 349 348 347 390 387 386 385 427 423 422 421 459 456 455 454

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 523 520 518 517 586 582 579 578 650 645 643 642 711 705 703 702 766 760 758 757 838 831 829 827 938 931 927 925 1,041 1,031 1,028 1,027 1,138 1,128 1,125 1,123 1,225 1,216 1,213 1,211

Anchor Bolts Quantity 30 54 78 102 30 54 78 102 30 54 78 102 30 54 78 102 30 54 78 102 Size M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

Tower Weight (KGS) Shipping 6,800 13,400 20,000 26,500 7,600 15,000 22,300 29,600 8,300 16,300 24,300 32,300 8,800 17,300 25,800 34,300 9,300 18,300 27,300 36,300 Operating 13,400 26,600 39,800 52,900 15,000 29,800 44,500 59,200 16,650 33,000 49,350 65,700 18,200 36,100 54,000 71,900 19,600 38,900 58,200 77,500

26

PCF SERIES...
CONCRETE BASIN LAYOUT
MODEL PCF 1200 TO PCF 2000

CONCRETE BASIN DIMENSION


Tower Model PCF 1200-C1 PCF 1200-C2 PCF 1200-C3 PCF 1200-C4 PCF 1400-C1 PCF 1400-C2 PCF 1400-C3 PCF 1400-C4 PCF 1600-C1 PCF 1600-C2 PCF 1600-C3 PCF 1600-C4 PCF 1800-C1 PCF 1800-C2 PCF 1800-C3 PCF 1800-C4 PCF 2000-C1 PCF 2000-C2 PCF 2000-C3 PCF 2000-C4
NOTES:
1. 2. 3. 4. FOUNDATION SHOULD BE DESIGNED TO CATER THE OPERATING WEIGHT OF THE COOLING TOWER. ALL FOUNDATIONS REQUIRED TO BE LEVELLED WITHIN 3 mm TOLERANCE AND PROVIDED WITH POCKETS FOR ANCHOR BOLTS. FOR COOLING TOWERS EXCEEDING 4 CELLS CONFIGURATION, CONSULT PANWATER FOR TOWER LAYOUT AND FOUNDATION DIMENSIONS. PANWATER RESERVES THE RIGHT TO ALTER OR MODIFY THE SPECIFICATION WITHOUT PRIOR NOTICE IN THE INTEREST OF PRODUCT IMPROVEMENT.

Center Distance Between Supports (mm) Loading Point L1 6,400 12,800 19,200 25,600 6,800 13,600 20,400 27,200 7,200 14,400 21,600 28,800 7,600 15,200 22,800 30,400 8,000 16,000 24,000 32,000 L2 6,400 6,400 6,400 6,400 6,800 6,800 6,800 6,800 7,200 7,200 7,200 7,200 7,600 7,600 7,600 7,600 8,000 8,000 8,000 8,000 L3 1,600 1,600 1,600 1,600 1,700 1,700 1,700 1,700 1,800 1,800 1,800 1,800 1,900 1,900 1,900 1,900 2,000 2,000 2,000 2,000 Quantity 25 45 65 85 25 45 65 85 25 45 65 85 25 45 65 85 25 45 65 85 170 168 167 167 189 186 184 184 209 206 205 204 225 223 221 220 234 231 230 229

Loading Data (KGS) Loading @ A Loading @ B Loading @ C 284 279 279 278 315 311 307 307 348 344 341 340 375 371 368 367 391 385 383 382 454 447 446 445 504 497 492 491 556 550 546 544 600 594 590 588 625 616 613 611

Anchor Bolts Quantity 30 54 78 102 30 54 78 102 30 54 78 102 30 54 78 102 30 54 78 102 Size M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

Tower Weight (KGS) Shipping 6,300 12,400 18,500 24,600 7,100 13,900 20,700 27,500 7,700 15,200 22,600 30,000 8,100 16,000 23,800 31,600 8,500 16,700 24,900 33,100 Operating 7,260 14,300 21,400 28,500 8,070 15,900 23,600 31,400 8,900 17,600 26,200 34,800 9,600 19,000 28,300 37,600 10,000 19,700 29,400 39,100

27

THE COOLING TOWER BEHIND THE INDUSTRY


PET Series
Induced draft cross flow cooling towers using timber splash bars as fill media supported on SS 304 grids. Tower structure constructed from Malaysian hardwood with heavy duty design mechanical equipment for continuous operation & long life span. Most commonly used in applications where water is contaminated and high temperature service. Industries with dusty environment, minimum maintenance provisions and continuous operational duration is anticipated.

PEG Series
Induced
draft cross flow cooling towers with high efficiency PVC fill media and drift eliminators. Tower structures are fabricated from hot dip galvanized heavy gauge sections with FRP hot water basin, cold water basin and exterior casing. Most suitable for cooling water requires very low temperature and high efficiency with respect to power consumption. Applicable to process water with comprehensive water treatment programme. larger flow capacity and limited plot area.

PCT Series
Induced draft cross flow cooling towers with high efficiency PVC fill media and drift eliminators. Tower structures are constructed from either Malaysian hardwood, zinc galvanised steel or FRP pultrusions. Most commonly used for process water requires very low temperature and high efficiency with respect to power consumption. Applicable to process water with comprehensive water treatment programme. larger flow capacity and limited plot area.

PCC Series
A similar type of cooling tower to the PCT Series except the tower structure is constructed of reinforced concrete. This type of cooling tower offer unlimited life span commonly applicable to larger cooling tower size only. Although the initial construction cost is relatively higher, long life span and low maintenence cost over a longer term encourage this type of cooling tower to be used in heavy industries and power plants where continuous operation over very long term is expected.

Manufacturer :

Your Local Agent :

PANWATER ENGINEERING SDN. BHD (173663-M)


Lot 817, AL 288, Jalan Kampung, Kampung Baru Sungai Buluh, 47000 Sungai Buluh, Selangor Darul Ehsan, Malaysia. Tel : 603-6157 9399 (Hunting Line) / 603-6157 5199 / 603-6156 8022 / 603-6156 9190 / 603-6156 9189 Fax : 603-6157 0399 E-mail : panwater@po.jaring.my