Вы находитесь на странице: 1из 4

Installation Instructions Beam Detector

PB-30 / PB-60 Features - Twin beams - Aspheric lens type - External light protection - Wide adjustment Function - Protection against frost/dew - Maximum range : 5 times that of the protection range

1. Description
Alarm LED Terminals Monitor jack Good LED Vertical adjustment screw View finder Lens Response time adjustment Power LED Tamper Tamper

Mounting plate

Receiver

Transmitter

Cover

2. Cautions on Installation

Avoid direct exposure to strong lights, such as sunlight and headlights. Avoid light in a direct path of 0~4 of optical axis.

Do not install the unit on unsteady surfaces.

Do not install in a site where beam may be interrupted by trees or plants; consider seasonal changes.

Do not install in places where units may be splashed frequently by dirty water or direct sea spray. (Causes dirt or salt build up on enclosures.)

3. Response Time
700 50

Response time (m/sec.)

4. Protection Distance and Expansion of beam


Protection distance and expansion of beam
MODEL PB-30 PB-60 l 30m (100ft) 60m (200ft) A 0.9m (3ft) 1.8m (6ft)

Protection distance l

5. Installation
5-1 Wall mounting
- Remove cover from unit and slide the mounting plate to detach it. - Break grommet on mounting plate and pull wire through it. Secure the plate with 4mm screws. - With your wire exposed, break knock-outs on the rear of unit, pull wire through as shown in the figure below and attach it to the mounting plate. Wire hole - After wiring is complete, adjust alignment, check operation and attach cover.

5-2 Pole mounting

6. Optical Alignment
Read voltage from monitor jack with a digital voltmeter to confirm optical alignment and to obtain the highest reliability. 1. Supply power with cover detached. 2. Set Transmitter lens to Receiver lens by using the view finder. Look through view finder on either side and line up optics horizontally and vertically until the opposite unit is visible. Using the adjustment, the lens can move horizontally (0~180) and vertically (0~14) allowing the unit to work in all directions. The opposite Transmitter or Receiver should appear on the view finder of inside middle mirror. 3. Adjust the Transmitter horizontally and vertically to get highest voltage reading. Adjust the Receiver horizontally and vertically to get highest voltage reading. - Reference table.
Vertical adjustment 7

View finder

Monitor Jack Output Voltage 3.0V or higher 3.0V or lower

Beam level Good Readjustment

4. Confirm the beam level by inserting a tester in monitor jack of receiver.


90 Horizontal adjustment

Receiver

7. Terminal assignment
After installation, test operation by walk testing.
Transmitter Receiver
NC

Status Power ON Good Alarm


NO

LED Display Green LED ON Red LED OFF / Green LED ON Red LED ON / Green LED OFF

Action

Response speed

POWER

GOOD(Green)/ALARM(Red) POWER(Green) : When Beam is alive, When Beam alignment is out, Red LED ON Green LED ON When Beam alignment is on, Green LED ON

8. Troubleshooting
Symptom Power LED does not light Alarm LED does not light when the beam is broken. Possible Cause 1. No power supply. 2. Bad wiring connection, broken wire or short. 1. No power supply. 2. Bad wiring connection, broken wire or short. 3. Beam is reflected on another object and sent into the receiver. 4. Two beams arent broken simultaneously 1. Beam alignment is out. 2. Shading object between Tx. and Rx. 3. Optics of units are soiled. 4. Improper channel. 1. Bad wiring connection. 2. Change of supply voltage. 3. Shading object between Tx. and Rx. 4. A large electric noise source, such as power machine, is located nearby Tx. and Rx. 5. Unstable installation of Transmitter and Receiver. 6. Soiled optics of Tx. and Rx. 7. Improper alignment. 8. Small animals may pass through the 2 beams Remedy 1. Turn on the power. 2. Check wiring. 1. Turn on the power. 2. Check wiring. 3. Remove the reflecting object or change beam direction. 4. Break 2 beams simultaneously. 1. Check and adjust again. 2. Remove the shading object. 3. Clean the optics with a soft cloth. 4. Check channel. 1. Check again. 2. Stabilize supply voltage. 3. Remove the shading object. 4. Change the place for installation. 5. Stabilize. 6. Clean the optics with a soft cloth 7. Check and adjust again. 8.Set the response time longer.

Alarm LED continues to light Intermittent alarms.

9. Technical Characteristics
MODEL Protection range Detection method Infrared beam Response time Supply voltage Current LED Alarm output Tamper output Temperature Beam adjustment Mounting site Material Weight PB-30 30m (100ft) PB-60 60m (200ft)

Twin synchronized pulsed beams IR LED 50 ~ 700mS DC 10.8 ~ 18V (Non-polarity) Receiver : 27mA, Transmitter : 30mA Tx : Power (Green) Rx : Good (Green), Alarm (Red) Dry contact relay output 1C Dry contact 1b (Rx) -20C ~ +60C (-4F ~ +140F Horizontal : 180 , Vertical : 14 Indoor / Outdoor Cover (PC resin), Base (ABS resin) Receiver : 369g, Transmitter : 357g

10. Dimensions

1601 NW 84 AVE, Miami, FL 33126 Phone: (305) 994-8186 / Fax: (305) 994-8167 Email: sales@paradoxbrand.com