IEC Title : Graphical Symbols for Diagrams Part 3 : Conductors and Connecting Devices )
National Foreword This Indian Standard ( Part 3 ) which is identical with IEC Pub 617-3 ( 1983 ) Graphical symbols ror diagrams - Part 3 : Conductors and connecting devices; issued by the International Electrotechnical Commission ( IEC ), was adopted by the Bureau of Indian Standards on the recommendation of the Basic 5lectrotechnical Standards Sectional Committee and approval of the Electrotechnical Division Council. Cross Reference InternationalStandard IEC Pub 445 ( 1973 ) Identification of apparatus terminals and general rules for a uniform system of terminal marking, using an alphanumeric notation Corresponding Indian Standard IS : 11353-1985 Guide for uniform system of marking and identification of conductors and apparatus terminals
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
0 November
1988, BIS
Gr 5
BUREAU
MANAK
OF
INDIAN
STANDARDS
MARG
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
SECTION 1 - CONDUCTORS
No. 03-01-01
Symbol
Description Conductor Group of conductors Line Cable Circuit Transmission path (for example, for microwaves)
Notes I. -
Singl+ne
representation of conductors.
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
When a single line represents a group of conductors, their number may be indicated either by adding small strokes or one stroke and a figure. OIi-OlM Form I rb
Examples:
Three conductors
03-01-03 Form 2 I
,3
2. -
Additional information may be indicated as follows: Above the line: kind of current, system of distribution, frequency and voltage;
Below the line: the number of conductors of the circuit followed by a multiplication sign and the cross-sectional area of each conductor. If different sizes of conductors are used, their particulars should be separated by a plus sign. The conductor material may be indicated by its chemical symbol.
034144
11ov
Examples:
Direct current circuit, 110 V, two ahtminium conductors
of 120 mm*
ZxlZOmm* Al
03-01-05
3N L
50 Hz 4OOV
Three-phase circuit, 50 Hz, 400 V, three conductors of 120 mm< with neutral of 50 mm
3x120 + 1x50
Flexible conductor
03-01-06
03-01-07
03-01-08
Twisted conductors, two conductors shown The note with symbol 03-01-09 applies
No.
03-0109
SplbOl
fi
I I I I
together or in a screen) but the lines representing them on a diagram are not adjacent to each other, the method shown below may be used.
03-01-10
Example:
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
03-01-11
Coaxial pair Note. - If the coaxial structure is not maintained, the tangential line should be drawn only on the coaxial side.
03-01-12
Example:
03-01-14
03-01-1s
SECTION 2 - TERMINALS
AND CON~IXTIONS
OF CONDUCTORS
No.
Symbol 0 0
Description Connection of conductors Terminal Note. - The circle rtIa9 be filled in.
3342-01 B342-02
B-02-03
Junction of conductors
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
03-02-06 Form 1 +0342-07 Form 2 + 03-02-08 Conductor joint In-line splice Connection common to a group of similar items Double junction of conductors
03-02-09
0342-10
10
Nore. - The total number of similar items may be indicated by a figure near the common connection symbol.
Example:
3-1 03-02-11 II
Interchange of conductors, change of phase sequence or inversion of polarity, shown for n conductors in singleline representation Note. - The interchanged conductors may be indicated. For the identification of the conductors, IEC Publication 445: Identification of Apparatus TerminaIs and General Rules for a Uniform System of Terminal Marking, Using an AIphanumeric Notation, applies.
Example:
03-m-12
Ll t3 e
.5
No.
03-02-13
03-U&14
Example: Synchronous generator, three-phase, both leads of each phase brought out, shown with external neutral point
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
SECTION 3 - CONNECTING
DEVICES
NO.
Symbol
Description
. Preferred form
Other form
03-03-01 4
Socket (female)
.,
03-03-03
Plug (male)
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
03-03-05 +I-03-03-06
_(t_
03-03-07 --I+-
Multipole multi-line
zz
zz *-
03-03@$g ---c+_
single-line
representation
03-03-O!I
Connector
Note. - The symbol should be used only when it is de--u sired to distinguish between the fixed and free parts of the connector assembly.
03-03-10
Connector
applies
Plug and jack, telephone type, two-pole Note. - The longest pole on the plug symbol represents the tip of the plug, and the shortest the sleeve.
Coaxial plug and socket Note. - If the coaxial plug or socket is connected to a coaxial pair, the tangential line(s) should be appropriately extended.
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
Plug and socket-type connector, for example U-link: male-male 03-03-21 male-female
03-03-22
03++&?
=4==
SUPPLIED BY BOOK SUPPLY BUREAU TO ACME TELE POWER LIMITED IMT, MANESAR FOR INTERNAL USE AT THIS LOCATION ONLY
03-04-03
Zli-line
representation
o3-04-04.
I
,3
I
,3
single-line representation
03-04-05
Junction box, shown with three conductors with T-connections: multi-line representation
03-
03-04-07
Pressure-tight bulkhead cable glahd, shown with three cables Note. - The high pressure side is the longer side of the trapezoid thus retaining gland in bulk-head.
9