LF-313LD

LAW-CHAIN

Refrigeration system controller

Panel

Technical

data

Power supply110V/220V AC/50~60Hz Temperature range-50~+80 DisplaySeven segment LED Working temperature-15~+70 MountingSnap-in(Panel) Accuracy1 Fit-in size137*28*32mm3(Panel) Resolution0.1 Fit-in size171*141*39mm3(Rear box) Maximum output ratingCompressor30A/250V(Resistance load) Heater16A/250V (Resistance load) FanLampDefog8A/250V (Resistance load) System parameter table
No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Symbol tS td Sd dt di dd dS FS CL rt tA Description The temperature stop compressor The temperature differential to restart compressor Compressor start time delay after stop Defrost typeELorHS Set defrosting after system running several hours Setting the duration of defrosting Defrost stop heating Fan start temperature the tine of condenser to clean the time of temperature for fraction Sensor calibration adjustment Range -50C ~ +80.0C +0.1C ~ +15.0C 0 ~ 15 Min. EL/HS 0 ~ 24 Hour 0 ~ 60 Min. 0C ~ +80.0C -50C ~ +30.0C 0~250 day 0-15 sec -10C ~ +10C Default -20C +4.0C 2Min. EL 4 Hour 20 Min. +25.0C 0.0C 0 day 0 sec 0.0C

Lock system parameter table


No. Symbol Description Range Default y lock/n unlock Select system parameters to lock or unlock y 1. LO The upper temperature limit 2. tH tS ~ +80.0C +50.0C The lower temperature limit 3. tL -50C ~ tS -50C High temperature alarm 4. AH tS+td~+80C +50.0C Temperature reachAH afterHtvalue alarm start working 0~180 Min. 90 Min. 5. Ht Low temperature alarm 6. AL -50C~tS -30C Temperature reachAL afterLtvalue alarm start working 0~180 Min. 60 Min. 7. Lt Defrost interval time type ti(hour)/CP(quarter hour) ti 8. tC y stop/ n running Fan working type y 9. FL Fan stop time(option for FL=y) 0~60 Min. 3 Min. 10. OF Fan run time(option for FL=y) 0~60 sec 15 sec 11. On Note (1).After choose y on the first lock system parameter LO ; means you select to lock the system parameters display will show system parametertSonlyand it can only be adjusted within the highest tH and lowest tLtemperature limitno other system parameters can be changedthereafter. On the contrary ifn is selectedthen all system parameters can be modified. (2).tCmeans defrost time count type .ti means hours unitCPmeans compressor running timeuse quarter hour unit.

Self test function


Error code E1H E1L E2H E2L AH AL Description Sensor shorted or temperature higher than +80.0C Sensor opened or temperature lower than -50C Evaporator sensor shorted or temperature higher than +80.0C Evaporator sensor opened or temperature lower than -50 High temperature alarm Low temperature alarm Condenser need to be clean

CLn

Operation : A. System parameter setting 1.Press SETkey the display flashes pattern888for 3 times then shows the symbol of the first system
1030018 1030019 REV:1 C,S:6BA9H 012507

LF-313LD
LAW-CHAIN

Refrigeration system controller

parametertS this means the controller entering the parameter modifying phase can press orkey to scroll up/down the parameter that is going to be adjust.Press SETkeythe display shows set valuecan push orkey to increase or decrease the value by one unitpress theSETkey the controller goes to modify the next parameter. PressSETkeythe display shows888 then display cabinet-room temperature mean that you finish parameters setting B. Lock system parameter setting 1.PressSETkey for three secondsthe display begins flashing pattern888. While flashingpress bothandkeys together until display showsLo(which means into parameters lock). PressSETagain the modified value would be showed. At this timepressor to lock by choosingyor to unlock by choosingn. 2.After select system parameters to unlock push SET key the display shows pattern tH can press or key to scroll-move to the next parameter. C. Other operations 1.After sent city power to controllerpushON/OFFkey to Power-onPonor Power-offPof. 2.After powerON the compressor is delaying for protecting. If you want to bypass the delay time and start immediately running the compressorthen you can pushkey until display showsFon. The controller then forces compressor to start up immediately. This special function is only effective on the power on stage. 3.Total operation hours (tot) The total compressor running time can be showed on display by showing three sets digits through push Press button andbutton simultaneously. For example if the total running time is 12345 hours the display will show first set tot (means total running time) then followed by the second digit set 012 then the last digit set345. 4.If there is no key was pushed within 30 seconds the controller jump back normal temperature display **While CLn is flashing , pressto cease alarm.** **To reset the CLnerror code, useon/offkey to trun Off power and turn on power again . The system will re-count the cleaning time. Function keys LED Indicators
ON/ OFF

Power on/off Increase/ Decrease

The controller power supply key To increase or decrease one unit value Request for setting the parameter Push this key to do manual defrost To on/off the door heater for clarify the showcase door To on/off the indoor light appliance

Yellow Green Red Yellow Yellow Yellow


C o r r e c t c o n n e c tio n m e th o d

Lamp on power supply Lamp flash compressor start up delay Lamp on compressor running Lamp on system defrosting Lamp on fan is running Lamp on door heater is on Lamp on indoor light appliance is on

SET

Set Manual defrost Door heater Light on/off

Sensor description

1.5M 4.5cm 6

S i g n a l w i r e w it h w h i te P V C j a c k e t

E x t e n d e d w ir e S h ie l d in g

I s o la t io n w i r e ( G r o u n d w ir e ) w it h b la c k o r r e d P V C ja c k e t

S ig n a l w ir e C o n n e c ts to t h e te r m in a l o n th e G ro u n d c o n t r o ll e r w ire

Isolation NTC sensor with BLACK PVC/1.5M/4.5cm6 metal head If you want to lengthen the NTC sensor probe , for isolating the noise , the extension wire must be shielded, and use the shielded wire as the ground wire. Isolation NTC sensor with RED PVC/1.5M/4.5cm6 metal head (as shown above).

Wiring diagram

LF-313LD
220V S2 GND S1 3 110V
RED WHITE BLACK WHITE

12 11 10 9 8

7 6 5

2 1

Evaporator ROOM
(RED) (BLACK) SENSOR

DEFOG LAMP

FAN DEFROST COMPRESSOR

AC1AC2
power line
1030018 1030019 REV:1 C,S:6BA9H 012507