TYPE B160 / TYPE B200 Single acting, Double acting and Two stage
CONTENTS
- Operating principle of Resato air-driven gas boosters types B160 and B200 - Introduction - Advantages of the Resato air-driven gas booster types B160 and B200 - Why use an air-driven gas booster - Operating the Resato air-driven gas booster - How to select the right Resato gas booster Dangerous gases Atex Gas booster selection information: Installation Resato gas boosters B160 and B200 material specications - Standard range performance of the high-pressure sealing - Accessories
Outlet (Po)
Supply (Ps)
INTRODUCTION
Resato offers a complete range of single, double acting and two-stage gas boosters. The boosters are available in various ratios. The higher the ratio the higher the output pressure of the booster. Single acting boosters only have one gas cylinder. Double acting boosters have two identical gas cylinders for a higher output ow. For higher compression ratios, e.g. relative high output pressure at relative low inlet pressure, two-stage boosters are used. These boosters have two different gas cylinders, each with a different ratio. The complete range is available in type B160 for normal ow rates and in type B200 for higher ow rates and higher pressures. Resato gas boosters are suitable for transfer and pressurization of a wide range of gases, e.g. Nitrogen, Helium, CO2, Argon and Breathing air. For use with other gases contact Resato for information on possible booster modications and installation instructions.
2
Supply (Ps)
Interstage
w w w. r e s a t o . c o m
w w w. r e s a t o . c o m
ATEX
As an option, Resato air driven gas boosters can be delivered in an ATEX 94/9/EC compliant version. The user of the gas booster is responsible for classifying the area of use, while identifying the equipment category is the responsibility of the manufacturer. Resato gas boosters are ATEX approved for Group II, category 2 zones G & D (code EX).
Double acting type (single acting is indicated by 1; double stage is indicated with two ratios) B160 65 2/EX
INSTALLATION
Resato gas boosters can be mounted in any position. For maintenance reasons you are advised to mount gas boosters in horizontal position, using the four thread holes in the air drive end caps. If it is not possible to use the standard thread holes, brackets can be used (see Accessories). The gas boosters will deliver their rated capacity at 7 bar (100 psi) air drive pressure with the required air ow. The air supply line requires an air pressure regulator to control the output of the gas booster. Apart from that it is necessary to mount an oil lubricator and a lter/water separator in the air supply line. A start/stop air valve can be mounted in the air supply line on request.
w w w. r e s a t o . c o m
Type
Pressure ratio
Max. compression ratio 785 cc 1570 cc 2450 cc 1570 cc 385 cc 770 cc 785 cc 1225 cc 770 cc 200 cc 400 cc 250 cc 400 cc 125 cc 385 cc 785 cc 250 cc 70 cc 140 cc 385 cc 125 cc 50 cc 100 cc 140 cc 200 cc 60 cc 100 cc 30 cc 125 cc 200 cc 125 cc 70 cc 60 cc 125 cc 70 cc 36 cc 18 cc 70 cc 22,6 cc 36 cc 11,3 cc 70 cc 30 cc 50 cc 82,2 bar(1190 psi) 82,5 bar(1195 psi) 83 bar(1200 psi) 15,6 bar (225 psi) 33,3 bar (480 psi) 22,2 bar (320 psi) 1235 bar (17910 psi) 1235 bar (17910 psi) 1245 bar (17910 psi) 6xPa 36xPa 36,7xPa 17,8 bar (260 psi) 46,4 bar (670 psi) 11,8 bar (170 psi) 2,3 bar (12 psi) 52,6 bar (760 psi) 53,1 bar (770 psi) 16,1 bar (230 psi) 25,5xPa 695 bar (10080 psi) 8,3xPa 34xPa 790 bar (11455 psi) 800 bar (11600 psi) 10,5xPa 65xPa+2xPs 100xPa+Ps 100xPa+4xPs 100xPa+2,3xPs 115xPa+Ps 115xPa 115xPa+4xPs 180xPa+Ps 180xPa+Ps 180xPa 180xPa+6xPs 180xPa+3xPs 180xPa+2,8xPs 535 bar 695 bar 710 bar 725 bar 800 bar 800 bar 805 bar 1260 bar 1260 bar 1260 bar 1330 bar 1330 bar 1330 bar 29,6 bar (430 psi) 29,7 bar (430 psi) 29,9 bar (435 psi) 7,5 bar (110 psi) 8,2 bar (120 psi) 12,2 bar (175 psi) 450 bar 450 bar 450 bar (6525 psi) (6525 psi) (6525 psi) 4,5xPa 4,5xPa 15,6xPa 65xPa+Ps 65xPa+Ps 65xPa 65xPa+4xPs 65xPa+4,3xPs 65xPa+2,6xPs 450 bar 450 bar 450 bar 450 bar 450 bar 485 bar (6525 psi) (6525 psi) (6525 psi) (6525 psi) (6525 psi) (7030 psi) (7760 psi) (10080 psi) (10295 psi) (10295 psi) (11600 psi) (11600 psi) (11670 psi) (18270 psi) (18270 psi) (18270 psi) (19285 psi) (19285 psi) (19285 psi) 19,1 bar (275 psi) 18,9 bar (275 psi) 20,6 bar (300 psi) 8,1 bar (115 psi) 285 bar 285 bar 310 bar (4130 psi) (4130 psi) (4495 psi) 7,5xPa 40xPa 40xPa+Ps 45xPa+Ps 45xPa+3xPs 285 bar 285 bar 310 bar 325 bar (4130 psi) (4130 psi) (4495 psi) (4715 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 11,6 bar (170 psi) 13,3 bar (190 psi) 13,2 bar (190 psi) 2,0 bar (30 psi) 8,3 bar (120 psi) 175 bar 210 bar 210 bar (2540 psi) (3050 psi) (3050 psi) 1xPa 15xPa 25xPa+Ps 30xPa 30xPa+Ps 30xPa+6xPs 30xPa+2xPs 175 bar 210 bar 210 bar 210 bar 250 bar (2540 psi) (3050 psi) (3050 psi) (3050 psi) (3625 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3,8 bar (55 psi) 4,8 bar (70 psi) 4,7 bar (68 psi) 7,4 bar (110 psi) 7,4 bar (110 psi) 7,5 bar (110 psi) 2,3 bar (33 psi) 1,9 bar (30 psi) 55 bar 70 bar 70 bar 110 bar 110 bar 115 bar (795 psi) (1015 psi) (1015 psi) (1595 psi) (1595 psi) (1670 psi) 2,5xPa 4xPa 8xPa+Ps 10xPa 10xPa+Ps 15xPa+Ps 15xPa+Ps 15xPa 15xPa+3xPs 15xPa+3,8xPs 55 bar 70 bar 70 bar 110 bar 110 bar 115 bar 115 bar 115 bar (795 psi) (1015 psi) (1015 psi) (1595 psi) (1595 psi) (1670 psi) (1670 psi) (1670 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/4 NPT-F 1/2 NPT-F 1/4 NPT-F 1/2 NPT-F 1/2 NPT-F 1/4 NPT-F 1/4 NPT-F 1/4 NPT-F 1/2 NPT-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F 1/4 NPT-F 1/2 NPT-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F 1/4 NPT-F 1/2 NPT-F 1/4 NPT-F 1/4 NPT-F M16x1,5 HP-F 1/4 NPT-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F 2,4 bar 2,4 bar 1,3 bar 1,3 bar (35 psi) (35 psi) (19 psi) (19 psi) 35 bar 35 bar (510 psi) (510 psi) 2,5xPa 4,2xPa 5xPa 5xPa+Ps 5xPa+2xPs 4xPa+1,6xPs 35 bar 35 bar 45 bar 45 bar (510 psi) (510 psi) (650 psi) (650 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/4 NPT-F 1/2 NPT-F 1/4 NPT-F 1/4 NPT-F 1/2 NPT-F 1/4 NPT-F 1/4 NPT-F 1/4 NPT-F 1/4 NPT-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F 1/4 NPT-F 1/4 NPT-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F M16x1,5 HP-F 17,5 kg 22 kg 22 kg 29 kg 29 kg 17,5 kg 22 kg 22 kg 29 kg 17,5 kg 22 kg 29 kg 29 kg 17,5 kg 22 kg 22 kg 22 kg 17,5 kg 22 kg 29 kg 29 kg 22 kg 29 kg 17,5 kg 22 kg 29 kg 29 kg 22 kg 29 kg 29 kg 29 kg 22 kg 17,5 kg 22 kg 22 kg 29 kg 17,5 kg 22 kg 22 kg 29 kg 1,8 bar 1,8 bar 1,8 bar 2,8 bar (26 psi) (26 psi) (26 psi) (40 psi) 18 bar 18 bar 18 bar 28 bar (260 psi) (260 psi) (260 psi) (405 psi) 2,5xPa 2,5xPa+Ps 2,5xPa+Ps 4xPa+Ps 18 bar 18 bar 18 bar 28 bar (260 psi) (260 psi) (260 psi) (405 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 1-7 bar (14-100 psi) 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 3/4 BSP-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 1/2 NPT-F 17,5 kg 22 kg 29kg 29 kg
Stroke volume
Outlet connection
Weight
up to 0-30 bar
up to 50 bar
1:2 1:1,6
up to 120 bar
1:3 1:3,8
up to 250 bar
1:6 1:2
up to 350 bar
40 40 45 1:15 / 1: 45
1:3
w w w. r e s a t o . c o m
up to 500 bar
up to 800 bar
1:30 / 1: 65 100 1:25 / 1:100 1:45 / 1:100 115 115 1:30 / 1:115
up to 1350 bar
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-2,5-1
1:2,5 1:10 785 cc 1,8 bar (26 psi) 18 bar (260 psi) 2,5 x Pa 18 bar (260 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 17,5 kg
600 500
Gas flow (Nl/min)
Ps= 6 Bar Ps= 5 Bar
10 Po (Bar)
15
AIR INLET
B160-2,5-2
66
197,5
310 740
197,5
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
6
B160-2,5-2
1:2,5 1:10 1570 cc 1,8 bar (26 psi) 18 bar (260 psi) 2,5 x Pa + Ps 18 bar (260 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 22 kg
10
Po (Bar)
15
20
w w w. r e s a t o . c o m
170
25
239
170
239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-2,5-2
1:2,5 1:10 2450 cc 1,8 bar (26 psi) 18 bar (260 psi) 2,5 x Pa + Ps 18 bar (260 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
Ps= 10 Bar
Ps= 8 Bar
Ps= 6 Bar
Ps= 4 Bar
10
Po (Bar)
20
B200-4-2
1/2'' NPT
1/2'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-4-2
1:4 1:10 1570 cc 2,8 bar (40 psi) 28 bar (405 psi) 4 x Pa + Ps 28 bar (405 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
20
Po (Bar)
30
40
7
w w w. r e s a t o . c o m
212
281
170
QA = Air ow
239
30
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-5-1
1:5 1:15 385 cc 2,4 bar (35 psi) 35 bar (510 psi) 5 x Pa 35 bar (510 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 17,5 kg
600 500
Gas flow (Nl/min)
Ps= 11 Bar
10
20 Po (Bar)
30
B160-5-2
66
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
8
B160-5-2
1:5 1:15 770 cc 2,4 bar (35 psi) 35 bar (510 psi) 5 x Pa + Ps 35 bar (510 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 22 kg
Ps= 12 Bar
Ps= 10 Bar
10
20
Po (Bar)
30
40
w w w. r e s a t o . c o m
170
239
Outlet
Outlet
170
50
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-2,5-5
1:2,5/1:5 1:35 1:2 785 cc 1,3 bar (19 psi) 2,5 x Pa 5 x Pa + 2 x Ps 49 bar (650 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 22 kg
600 500
Gas flow (Nl/min)
Ps= 6 Bar Ps= 5 Bar Ps= 4 Bar Ps= 3 Bar Ps= 2 Bar
10
20
Po (Bar)
30
40
B200-2,5-4
1/2'' NPT
87
170
50
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-2,5-4
1:2,5/1:4 1:35 1:1,6 1225 cc 1,3 bar (19 psi) 4,2 x Pa 4 x Pa + 1,6 x Ps 45 bar (650 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
2500
2000
Gas flow (Nl/min)
Ps= 15 Bar
1500
Ps= 10 Bar
1000
Ps= 5 Bar
500
Ps= 2 Bar
25
Po (Bar)
50
212
75
9
w w w. r e s a t o . c o m
281
239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-8-2
1:8 1:15 770 cc 3,8 bar (55 psi) 55 bar (795 psi) 8 x Pa + Ps 55 bar (795 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
Ps= 15 Bar
20
30
40 Po (Bar)
50
60
70
B160-10-1
3/4'' BSP
66
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
10
B160-10-1
1:10 1:15 200 cc 4,8 bar (70 psi) 70 bar (1015 psi) 10 x Pa 70 bar (1015 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 17,5 kg
600
Ps= 30 Bar
500
Ps= 25 Bar
20
40 Po (Bar)
60
w w w. r e s a t o . c o m
170
212
1/2'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-10-2
1:10 1:15 400 cc 4,7 bar (68 psi) 70 bar (1015 psi) 10 x Pa + Ps 70 bar (1015 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 22 kg
Ps= 15 Bar
20
40
Po (Bar)
60
80
170
QA = Air ow
100
B160-15-2
1/4'' NPT
66
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-15-2
1:15 1:15 250 cc 7,4 bar (110 psi) 110 bar (1595 psi) 15 x Pa + Ps 110 bar (1595 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 22 kg
50
Po (Bar)
100
150
11
w w w. r e s a t o . c o m
1/2'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-15-2
1:15 1:15 400 cc 7,4 bar (110 psi) 110 bar (1595 psi) 15 x Pa + Ps 110 bar (1595 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
1200 1000
Gas flow (Nl/min)
Ps= 25 Bar Ps= 20 Bar Ps= 15 Bar
800 600
Ps= 10 Bar
400 200
Ps= 8 Bar
25
50
Po (Bar)
75
100
B160-15-1
66
1/4'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
12
B160-15-1
1:15 1:15 125 cc 7,5 bar (110 psi) 115 bar (1670 psi) 15 x Pa 115 bar (1670 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 17,5 kg
600 500
Gas flow (Nl/min)
Pa
= 6 Bar
Ps= 40 Bar
Ps= 30 Bar
Ps= 20 Bar
100
20
40
Po (Bar)
60
80
w w w. r e s a t o . c o m
170 239
212
125
100
281
1/2'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-5-15
1:5/1:15 1:50 1:3 385 cc 2,3 bar (33 psi) 2,5 x Pa 15 x Pa + 3 x Ps 115 bar (1670 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 22 kg
600 500
Gas flow (Nl/min)
Pa
= 6 Bar
Ps= 9 Bar
Ps= 6 Bar
Ps= 3 Bar
50
Po (Bar)
100
150
B200-4-15
1/2'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-4-15
1:4/1:15 1:60 1:3,8 785 cc 1,9 bar (30 psi) 4 x Pa 15 x Pa + 3,8 x Ps 115 bar (1670 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/2'' NPT-F 29 kg
500
400
Ps= 5 Bar
Ps= 4 Bar
300
200
100
50
Po (Bar)
100
150
13
w w w. r e s a t o . c o m
212
281
1/2'' NPT
170
110 212
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-25-2
1:25 1:15 250 cc 11,6 bar (170 psi) 175 bar (2540 psi) 25 x Pa + Ps 175 bar (2540 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 29 kg
30
60
90
120 Po (Bar)
150
180
210
B160-30-1
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
14
B160-30-1
1:30 1:15 70 cc 13,3 bar (190 psi) 210 bar (3050 psi) 30 x Pa 210 bar (3050 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 17,5 kg
500
Ps= 70 Bar
400
Ps= 60 Bar
300
200
Ps= 30 Bar
100
50
100
Po (Bar)
150
200
w w w. r e s a t o . c o m
170
212
250
1/4'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-30-2
1:30 1:15 140 cc 13,2 bar (190 psi) 210 bar (3050 psi) 30 x Pa + Ps 210 bar (3050 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 22 kg
100
Po (Bar)
AIR INLET
200
170
B160-5-30
1/2'' NPT Outlet
26,4
66
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-5-30
1:5/1:30 1:100 1:6 385 cc 2,0 bar (30 psi) 1 x Pa 30 x Pa + 6 x Ps 210 bar (3050 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/4'' NPT-F 22 kg
300 250
Gas flow (Nl/min)
Ps= 6 Bar
Ps= 2 Bar
100
Po (Bar)
200
170
300
15
w w w. r e s a t o . c o m
239
300
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-15-30
1:15/1:30 1:30 1:2 125 cc 8,3 bar (120 psi) 15 x Pa 30 x Pa + 2 x Ps 250 bar (3625 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 22 kg
600 500
Gas flow (Nl/min)
Ps= 50 Bar Ps= 40 Bar Ps= 30 Bar
400 300
Ps= 20 Bar
200
Ps= 10 Bar
100
100
200
Po (Bar)
66
M16x1.5 239 25,5 290 341 525 M16x1.5 168 17,5 M6 110 170
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
16
B160-40-1
1:40 1:15 50 cc 19,1 bar (275 psi) 285 bar (4130 psi) 40 x Pa 285 bar (4130 psi)) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 17,5 kg
500
Ps= 100 Bar
400
Ps= 80 Bar
300
Ps= 60 Bar
200
Ps= 40 Bar
100
Ps= 20 Bar
50
100
Po (Bar)
150
200
w w w. r e s a t o . c o m
170
QA = Air ow
170
QA = Air ow
300
250
M16x1.5
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-40-2
1:40 1:15 100 cc 18,9 bar (275 psi) 285 bar (4130 psi) 40 x Pa + Ps 285 bar (4130 psi)) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 22 kg
Ps= 80 Bar
Ps= 60 Bar
Ps= 40 Bar
100
200 Po (Bar)
300
B200-45-2
1/4'' NPT
1/4'' NPT
170 1/4'' NPT 16,5 168 290 341 711 1/4'' NPT 16,5 168 M6 110 212
QA = Air ow
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-45-2
1:45 1:15 140 cc 20,6 bar (300 psi) 310 bar (4495 psi) 45 x Pa + Ps 310 bar (4495 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F 1/4'' NPT-F 29 kg
100
150
200 Po (Bar)
250
300
350
17
w w w. r e s a t o . c o m
212
QA = Air ow
281
239
1/4'' NPT
110 212
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-15-45
1:15/1:45 1:40 1:3 200 cc 8,1 bar (115 psi) 7,5 x Pa 45 x Pa + 3 x Ps 325 bar (4715 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F 1/4'' NPT-F 29 kg
600 500
Gas flow (Nl/min)
Ps= 30 Bar Ps= 25 Bar Ps= 20 Bar Ps= 15 Bar Ps= 10 Bar
50
100
150
200 Po (Bar)
250
300
350
66
M16x1.5
212
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
18
B160-65-2
1:65 1:15 60 cc 29,6 bar (430 psi) 450 bar (6525 psi) 65 x Pa + Ps 450 bar (6525 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 22 kg
200
300
400 Po (Bar)
500
600
700
w w w. r e s a t o . c o m
239
281
M16x1.5 281
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-65-2
1:65 1:15 100 cc 29,7 bar (430 psi) 450 bar (6525 psi) 65 x Pa + Ps 450 bar (6525 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 29 kg
1200 1000
Gas flow (Nl/min)
800
Ps= 75 Bar
600
Ps= 50 Bar
400 200
100
200
300
400 Po (Bar)
500
600
700
B160-65-1
66
M16x1.5 239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-65-1
1:65 1:15 30 cc 29,9 bar (435 psi) 450 bar (6525 psi) 65 x Pa 450 bar (6525 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 17,5 kg
500
400
Ps= 130 Bar
300
200
100
100
200
Po (Bar)
300
400
170
QA = Air ow
212
500
19
w w w. r e s a t o . c o m
M16x1.5
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-15-65
1:15/1:65 1:60 1:4 125 cc 7,5 bar (110 psi) 4,5 x Pa 65 x Pa + 4 x Ps 450 bar (6525 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F M16x1,5 HP-F 22 kg
300 250
Gas flow (Nl/min)
Ps= 25 Bar
75
150
225
300 Po (Bar)
375
450
525
AIR INLET
87
B200-15-65
1/2'' NPT
3/4BSP
1/4'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
20
B200-15-65
1:15/1:65 1:55 1:4,3 200 cc 8,2 bar (120 psi) 4,5 x Pa 65 x Pa + 4,3 x Ps 450 bar (6525 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/2'' NPT-F M16x1,5 HP-F 29 kg
500
400
Gas flow (Nl/min)
300
Ps= 15 Bar
200
Ps= 10 Bar
100
100
200
300
400 Po (Bar)
500
600
700
w w w. r e s a t o . c o m
212
281
170
QA = Air ow
239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-25-65
1:25/1:65 1:40 1:2,6 125 cc 12,2 bar (175 psi) 15,6 x Pa 65 x Pa + 2,6 x Ps 485 bar (7030 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F M16x1,5 HP-F 29 kg
600 500
Gas flow (Nl/min)
Ps= 50 Bar
400 300
200 100
Ps= 15 Bar
100
200
300
400 Po (Bar)
500
600
700
66
M16x1,5 239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-30-65
1:30/1:65 1:30 1:2 70 cc 17,8 bar (260 psi) 25,5 x Pa 65 x Pa + 2 x Ps 535 bar (7760 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F M16x1,5 HP-F 22 kg
600 500
Gas flow (Nl/min)
Ps= 90 Bar
Ps= 70 Bar
Ps= 50 Bar
100
200
300
400 Po (Bar)
500
600
700
21
w w w. r e s a t o . c o m
170
QA = Air ow
212
QA = Air ow
M16x1.5 281
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-100-2
1:100 1:15 60 cc 46,4 bar (670 psi) 695 bar (10080 psi) 100 x Pa + Ps 695 bar (10080 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 29 kg
150
300
450
600 Po (Bar)
750
900
1050
B200-25-100
1/4'' NPT
87
M16x1.5 281
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
22
B200-25-100
1:25/1:100 1:60 1:4 125 cc 11,8 bar (170 psi) 8,3 x Pa 100 x Pa + 4 x Ps 710 bar (10295 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F M16x1,5 HP-F 29 kg
600 500
Gas flow (Nl/min)
400
Ps= 40 Bar
200
400
Po (Bar)
600
800
1000
w w w. r e s a t o . c o m
212
212
1/4'' NPT
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B200-45-100
1:45/1:100 1:60 1:2,3 70 cc 2,3 bar (12 psi) 34 x Pa 100 x Pa + 2,3 x Ps 725 bar (10295 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 22 kg
600 500
Gas flow (Nl/min)
Ps= 50 Bar
200
400
Po (Bar)
600
800
1000
B160-115-2
M16x1.5
66
M16x1.5
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-115-2
1:115 1:15 36 cc 52,6 bar (760 psi) 800 bar (11600 psi) 115 x Pa + Ps 800 bar (11600 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 22 kg
600 500 400 300 200 100 75 150 225 300 375 450 525 600 675 750 825 900 975 1050 1125 Po (Bar)
23
Ps= 150 Bar Ps= 100 Bar
w w w. r e s a t o . c o m
170
239
212
M16x1.5 239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
B160-115-1
1:115 1:15 18 cc 53,1 bar (770 psi) 800 bar (11600 psi) 115 x Pa 800 bar (11600 psi) 1-7 bar (11600 psi) 3/4'' BSP-F M16x1,5 HP-F M16x1,5 HP-F 17,5 kg
600 500
Gas flow (Nl/min)
Ps= 350 Bar Ps= 300 Bar
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Po (Bar)
B160-30-115
1/4'' NPT
66
M16x1,5 239
TECHNICAL DATA
Pressure ratio Max. compression ratio Stroke volume ratio Stroke volume Minimal supply pressure (Ps) Maximum supply pressure (Ps) Actual gas outlet pressure (Po) Max. outlet pressure (Po) Air drive pressure (Pa) Air supply connection Gas supply connection Outlet connection Weight
24
B160-30-115
1:30/1:115 1:50 1:4 70 cc 16,1 bar (230 psi) 10,5 x Pa 115 x Pa + 4 x Ps 805 bar (11670 psi) 1-7 bar (14-100 psi) 3/4'' BSP-F 1/4'' NPT-F M16x1,5 HP-F 22 kg
Ps= 60 Bar Ps= 50 Bar Ps= 40 Bar Ps= 30 Bar Ps= 20 Bar
300
450
600 Po (Bar)
750
900
1050
w w w. r e s a t o . c o m
170
170
M16x1.5
TECHNICAL DATA
B160-180-2
1:180 Pressure ratio 1:15 Max. compression ratio Stroke volume ratio 22,6 cc Stroke volume 82,2 bar (1190 psi) Minimal supply pressure (Ps) Maximum supply pressure (Ps) 1260 bar (18270 psi) 180 x Pa + Ps Actual gas outlet pressure (Po) 1260 bar (18270 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection M16x1,5 HP-F Gas supply connection M16x1,5 HP-F Outlet connection 22 kg Weight
1200 1000
Gas flow (Nl/min)
Ps= 500 Bar
250
500
750
1000 Po (Bar)
1250
1500
1750
AIR INLET
B200-180-2
M16x1.5
3/4'' BSP
87
M16x1.5
TECHNICAL DATA
B200-180-2
1:180 Pressure ratio 1:15 Max. compression ratio Stroke volume ratio 36 cc Stroke volume 82,5 bar (1195 psi) Minimal supply pressure (Ps) Maximum supply pressure (Ps) 1260 bar (18270 psi) 180 x Pa + Ps Actual gas outlet pressure (Po) 1260 bar (18270 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection M16x1,5 HP-F Gas supply connection M16x1,5 HP-F Outlet connection 29 kg Weight
750
1000 Po (Bar)
1250
1500
1750
25
w w w. r e s a t o . c o m
212
QA = Air ow
281
170
239
M16x1.5 239
TECHNICAL DATA
B160-180-1
1:180 Pressure ratio 1:15 Max. compression ratio Stroke volume ratio 11,3 cc Stroke volume 83 bar (1200 psi) Minimal supply pressure (Ps) Maximum supply pressure (Ps) 1260 bar (18270 psi) 180 x Pa Actual gas outlet pressure (Po) 1260 bar (18270 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection M16x1,5 HP-F Gas supply connection M16x1,5 HP-F Outlet connection 17,5 kg Weight
600
Ps= 600 Bar
500
Gas flow (Nl/min)
75 150 225 300 375 450 525 600 675 750 825 900 975 1050 1125 Po (Bar)
AIR INLET
B160-30-180
1/4NPT
3/4'' BSP
66
M16x1,5 239
168
M6
110 170
TECHNICAL DATA
B160-30-180
1:30/1:180 Pressure ratio 1:80 Max. compression ratio 1:6 Stroke volume ratio 70 cc Stroke volume 15,6 bar (225 psi) Minimal supply pressure (Ps) 6 x Pa Maximum supply pressure (Ps) 180 x Pa + 6 x Ps Actual gas outlet pressure (Po) 1330 bar (19285 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection 1/4'' NPT-F Gas supply connection M16x1,5 HP-F Outlet connection 22 kg Weight
26
300 250
Gas flow (Nl/min)
Ps= 35 Bar Ps= 30 Bar Ps= 25 Bar Ps= 20 Bar Ps= 15 Bar
200
400
600
800 Po (Bar)
1000
1200
1400
w w w. r e s a t o . c o m
170
170
M16x1,5 239
TECHNICAL DATA
B160-65-180
1:65/1:180 Pressure ratio 1:40 Max. compression ratio 1:3 Stroke volume ratio 30 cc Stroke volume 33,3 bar (480 psi) Minimal supply pressure (Ps) 36 x Pa Maximum supply pressure (Ps) 180 x Pa + 3 x Ps Actual gas outlet pressure (Po) 1330 bar (19285 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection M16x1,5 HP-F Gas supply connection M16x1,5 HP-F Outlet connection 22 kg Weight
600 500
Ps= 210 Bar
400 300
200
Ps= 50 Bar
100
300
600
900
1200 Po (Bar)
1500
1800
2100
AIR INLET
B200-65-180
1/4'' NPT
3/4BSP
87
M6
110 212
TECHNICAL DATA
B200-65-180
1000
1:65/1:180 Pressure ratio 1:60 Max. compression ratio 1:2,8 Stroke volume ratio 50 cc Stroke volume 22,2 bar (480 psi) Minimal supply pressure (Ps) 36,7 x Pa Maximum supply pressure (Ps) Actual gas outlet pressure (Po) 180 x Pa + 2,8 x Ps 1330 bar (19285 psi) Max. outlet pressure (Po) 1-7 bar (14-100 psi) Air drive pressure (Pa) 3/4'' BSP-F Air supply connection M16x1,5 HP-F Gas supply connection M16x1,5 HP-F Outlet connection 29 kg Weight
800
Ps= 210 Bar
600
400
200
300
600
900
1200 Po (Bar)
1500
1800
2100
27
w w w. r e s a t o . c o m
212
170
Air inlet
Cycling valve
Pilot hole
H.P. ange
HIGH-PRESSURE SECTION: High pressure cylinder: bronze RG7; stainless steel 1.4122/15-5PH High pressure piston: stainless steel 1.4112/1.3980/17-4PH/ (guiding material: CuSn8) Check valves: housing: stainless steel 1.4122/15-5PH balls: ceramic other internal parts: stainless steel 1.4404/17-4PH Clamping rings: PVC SEALINGS: Check valves: (Ceramic) High-pressure piston: polymer compounds based on low-friction PTFE resins Alternative: on request Air piston: NBR V-shaped rings
28
w w w. r e s a t o . c o m
EXHAUST MUFFLER
To suppress noise and prevent ingress of contamination into the air cycling valve, the gas boosters are standard supplied with exhaust mufers: - type S-16 for the B160 range - type S-20 for the B200 range. If no exhaust mufer is required or available and noise levels are above acceptable, exhaust pipes can be led away to a remote location.
BRACKETS
If for any reason the thread holes in the air drive end caps cannot be used to mount the gas booster, four welding brackets (4) can be used. The nuts of the air cylinder clamping bolts can be used to mount the brackets to the gas booster. Ordering code for the brackets is B-16/20 for booster types B160 and B200.
ADAPTERS
Many booster types have a high-pressure connection (see selection tables). If necessary, Resato can provide highpressure adapters with UNF high-pressure NPT or BSP thread connections. Please refer to our catalogue of high-pressure ttings, adapters and tubing for more information.
ORDERING EXAMPLE
B200 Booster range 65 Ratio 2 Double acting / / EX Atex version
(refer to table)
29
w w w. r e s a t o . c o m
NOTES
30
w w w. r e s a t o . c o m
NOTES
31
w w w. r e s a t o . c o m
RESATO INTERNATIONAL BV
1e Energieweg 13 NL-9301 LK P.O. Box 30 NL-9300 AA Roden - Holland Roden - Holland Phone: +31 (0) 50 501 6877 Fax: +31 (0) 50 501 2402 E-mail: hpsales@resato.com Internet: www.resato.com
Please note that general data and specications given in this brochure are subject to change without notice. Feel free to contact our sales department if you need more denite information.