Вы находитесь на странице: 1из 46

SERVICE

Whirlpool EMEA Customer Services

AWE 6316/1

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 2 of 44

Service Information Toploader Washing machine AWE 6316/1


8593 631 10080 Last Modication: 07/10/08 Creation Date: 07/10/08

Spare Part List Exploded View Technical Data Wiring Diagram Circuit Diagram Program Chart Testprogram Error Codes Service Bulletin 4812 712 40355 Service Bulletin 4812 712 40354 Service Bulletin 4812 712 40322 Service Bulletin 4812 712 40317 Service Bulletin 4812 712 40308 Service Bulletin 4812 712 40327 Service Bulletin 4812 712 40348 Service Bulletin 4812 712 40320 Service Bulletin 4812 712 40313 Service Bulletin 4812 712 40319 Service Bulletin 4812 712 40321 Service Bulletin 4812 712 40315

2 4 6 8 10 12 20 21 25 27 29 31 32 35 36 38 39 40 42 44

This document is only intended for qualied technicans who are aware of the respective safety regulations. Subject to modications Whirlpool EMEA www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 3 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Spare Part List
Pos 002 0 002 1 004 0 010 0 010 1 011 0 012 7 012 8 021 0 022 0 022 1 024 0 040 0 061 0 061 1 061 2 081 4 086 4 086 5 100 1 100 3 100 5 110 4 130 0 191 0 191 1 200 0 201 0 220 0 221 1 223 0 223 1 271 0 272 0 290 0 301 0 331 0 331 2 332 0 333 0 333 1 400 0 421 0 421 2 430 0 451 0 490 0 490 1 521 0 521 0 12NC 4812 459 38057 4812 459 38058 4812 440 19625 4812 459 48175 4812 440 11637 4812 462 48054 4812 310 18497 4812 528 78075 4812 440 10838 4812 440 10839 4812 440 10841 4812 440 11638 4812 417 19155 4812 466 88995 4812 466 88996 4812 466 88492 4812 529 18043 4812 529 18045 4812 529 18052 4812 440 10842 4812 440 10843 4812 440 10845 4812 498 18249 4812 417 19193 4812 466 68596 4812 492 98037 4812 418 18692 4801 101 00027 4812 418 18632 4812 310 18843 4812 418 48725 4812 418 48605 4812 358 18167 4812 528 88083 4812 532 68078 4801 101 00016 4812 414 58306 4812 414 58307 4812 410 29501 4812 410 29503 4812 410 29504 4812 361 58444 4812 121 18285 4812 404 38679 4801 101 00001 4812 259 28919 4819 321 18136 4812 321 28367 4801 101 00023 4812 214 70658 Description

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 4 of 44

Flap round GW Hinge ap GW Drip tray assy Door frame inner GW Frame Top+nozzle box KIT Foot Trolley kit front Foot rear Front panel WH GW Side panel right GW Side panel left GW Rear panel Hinge bolt lid GW Counter weight rear, 5 pts Counter weight front Counter weight bottom Shock absorber Pin f. Shock absorber Damper f. Shock absorber Lid outer GW Lid inner GW Lid assembly WH GW Handle cpl. WH GW Door latch GW Door bellow Strap f. bellow Tub LR-5pins/4x Cover f. tub LR/4x Drum 210 mm Kit latch f.drum 641m lifter Drum lifter 54 mm with weight BELT PV 1204 H8 Pulley 298 mm Gasket Control panel AWE 6316/1 Knob timer Spring Knob timer Push button 4 Opt. Push button start/reset Push button option Motor 1BA5736-0WA/BSH Interf.lter Holder RFI Pump,draining Heating element 2050W, 230V + NTC Cable mains 2m SA Strain relief Control unit DOMINO, programmed Control unit Eureka

Whirlpool EMEA

www.scc-service.com

SERVICE
Pos 571 0 571 1 581 0 620 0 630 0 653 0 653 1 691 0 701 0 702 2 707 0 707 1 712 4 712 6 712 9 753 0 754 0 754 1 760 0 781 0 782 0 787 0 787 1 794 0 900 0 900 1 900 2 900 3 901 0 910 0 910 1 910 3 910 4 910 5 910 6 921 0 930 1 930 2 941 0 953 0 962 0 962 2 965 0 990 0 990 2 993 0 993 1 12NC 4812 281 28468 4812 281 18069 4812 271 28554 4812 239 58046 4812 271 38519 4812 134 18077 4812 134 18078 4812 282 19485 4812 530 29329 4812 530 29453 4812 526 48244 4812 526 48049 4812 418 68302 4812 418 68164 4812 418 68404 4812 418 68187 4812 530 28938 4812 530 28832 4812 480 58403 4819 530 29035 4812 530 28941 4812 530 29309 4812 530 29311 4812 530 58098 4819 401 18686 4812 401 18431 4812 255 18304 4819 401 18529 4812 401 18462 4812 502 48347 4812 502 38151 4812 502 18404 4812 502 18423 4812 502 18705 4812 505 18367 4812 400 18047 4812 492 48171 4812 492 48162 4812 310 19144 4812 325 68001 4812 440 98142 4812 440 11424 4812 462 79974 4812 310 19224 4812 310 18506 4819 530 29028 4812 290 18025 Description

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 5 of 44

Valve magnet 1 inlet, 2 outlets Cover for top frame Pressostat Module E3/4 Opt. Door lock Light guide PR.FLOW-FULL Light guide 4 Opt. Sensor NTC Hose, inlet; EN 11770 Reex Hose valve-dispenser Nozzle box cold cpl. Clamp f. nozzle box Siphon f. softener Clip soap dispenser Soap dispenser Chamber,air Drainhose Lock eco Filter Hose draining Hose Pressostat Hose Air Exaust Cover of hose Gasket Clamp hose Clamp to pump Holder hose Clamp hose Clamp drain hose; drain hose Screw,selftap 3,5x14 Screw 4x14 Hex ange bolt M6x16 Screw PT 7x15 Screw M8x35 Nut push in M 8 Washer Torsions spring Spring Bearing kit ALL 1100 Shaft seal Cover for Motor AC Spacer Cap Transport blocking Fixing mat.set Counter weight Fixing mat.set bottom U Curve for outlet hose Clamp heating element

Whirlpool EMEA

www.scc-service.com

SERVICE
Exploded View

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 6 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Exploded View

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 7 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Technical Data
Dimensions + Weight

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 8 of 44

Product dimensions Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 cm Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 cm Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 cm Weight net . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 kg

Electrical base data


Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V 10% Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 A Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~2.3 kW

Drum data
Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 l Wash speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 rpm Spinning max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 rpm

Pressostat
Level1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12/14 Overow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 16

Door lock
Kind of switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch with PTC heater of bimetal Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 (90 - 264) V Locking time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 s Unlock time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 s

Inlet valve
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 - 240 V / 50 Hz Rated ow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (1.5 - 5 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 l/min Pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 - 10 bar Nominal resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (20 C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8 k

Drain pump
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 - 240 V / 50 Hz Total power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 W Resistor (coil) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (0.55 - 1 m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2 l/min Position of draining hose outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.9 - 1.25 m

Whirlpool EMEA

www.scc-service.com

SERVICE
Heating element

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 9 of 44

Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V + 10 %, -15 % Total power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2050 W Resistance (20 C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Leakage current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.8 mA NTC sensor Resistance NTC 0 C 30 C 40 C 50 C 60 C 70 C 95 C 35.9 9.8 6.6 4.6 3.2 2.3 1.1 k k k k k k k

Motor
Resistance contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (20 C) Stator (full eld) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.95 Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.85 Tacho generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.3

Control unit
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOMINO Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V - 240 V Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz Output control unit Motor Aquastop In pump step NTC Pump Doorlock Pressostat - empty - full Valve (Rast 2.5) Options M7.6 - DSS3.2 AQ2.2 - DSS3.2 AQ2.1 - DSS3.3 Not measurable DP2.1 - DP2.2 DSS3.1 - DSS3.3 E4 - E2 PR2.1 - E2 PR2.2 - E2 V2.1 - V2.2 Not measurable >40 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V >170 V

Whirlpool EMEA

www.scc-service.com

SERVICE
Wiring Diagram

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 10 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Legend

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 11 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Circuit Diagram

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 12 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Legend

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 13 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 14 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 15 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 16 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 17 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 18 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 19 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 20 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Program Chart

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 21 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Testprogram

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 22 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Error Codes

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 23 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Error Codes

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 24 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Error Codes

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 25 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE
Error Codes

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 26 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 27 of 44

Service Bulletin 4812 712 40355


AUTHOR: Ronny Schuricht Last Update: 05/11/11 VERSION: 1.0 TITLE: Water dripping from lid onto side panels. SUBJECT: In rare cases, when the lid is opened after a washing cycle, water drips down the side panels.

REMEDIAL ACTION
If customer claims wet side panels, remove the lid and put some silicon in the area of the frame like shown in the pictures.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 28 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 29 of 44

Service Bulletin 4812 712 40354


AUTHOR: Ronny Schuricht Last Update: 02/07/11 VERSION: 1.0 TITLE: new xation pin for shock absorber SUBJECT: Since 8th dec. 2010 a new pin xing the shock absorber to the tub is used in production .

REMEDIAL ACTION
The new pin is interchangeable with the old version. In SPC the old pins will be replaced by the new version.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 30 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 31 of 44

Service Bulletin 4812 712 40322


AUTHOR: Ronny Schuricht Last Update: 06/22/11 VERSION: 2.0 TITLE: weighted drum lifter replaced SUBJECT: The weighted drum lifter 4812 418 48605 is out of production and will not be available anymore.

REMEDIAL ACTION
When ordering the weighted drum lifter, you will get automatically the usuall lifter without integrated weight 4819 418 49713. With the new drum lifter the drum has got a certain unbalance also when it is empty. Due to this fact it can happen that during the test program the spin is not performed (unbalance detection). For machines with Domino control board its possible to use an alternative start procedure for the test program (no unbalance detection) to test the spinning anyway:

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 32 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 33 of 44

Service Bulletin 4812 712 40317


AUTHOR: Ronny Schurricht Last Update: 07/01/09 VERSION: 1.0 TITLE: Heating Element alternative solution. SUBJECT: In special conditions it can occur that the heating element after a short period gets broken caused by very hard water (limestone) or variations in power supply.

REMEDIAL ACTION
If the heating element gets broken under mentioned conditions we recommend using the alternative heating element that is nickel treated and usable for power supply up to 240V. According to SPC 600 pieces will be on stock from week 52 onwards.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 34 of 44

Service Bulletin 4812 712 40308


AUTHOR: Ronny Schurricht Last Update: 07/01/09 VERSION: 1.0 TITLE: wiring as spare part SUBJECT: Due to some requests we introduce all the wiring cables between timer and the different components as spare parts.

REMEDIAL ACTION
Please nd the needed wiring in the tables on the following pages. The wirings will be not included in any Service Info. In the tables underneath you can nd standardized wirings that are covering all versions of machines. Therefore they can be longer than the original ones. When installing the new wirings the original routing of cables must be kept in order to avoid any damages caused by kinking or touching with other components.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 35 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 36 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 37 of 44

Service Bulletin 4812 712 40327


AUTHOR: Ronny Schuricht Last Update: 01/21/10 VERSION: 1.0 TITLE: "F08"at end of cycle and "clean lter"indication SUBJECT: A new software for the controlboards mentioned below has been released. The new software includes a modication of F08 identication and an improvement of the pump cycle in order to avoid "long drain"and "clean lter"indications, caused by ecoball sticking.

REMEDIAL ACTION
"F 08": If that failure indication appears at the end of a wash cycle and all parts like heating element and wiring are ok, then replace the original control board by the new one and program the board by SAM. "clean lter": If this indication appears, but the pump lter and the drain hoses are empty, not kinked and well mounted and it is sure, that the indication is related to ecoball sticking in the drain hose (tub-pump) even it is already replaced by the new version (SB 481271240326), then replace the original control board by the new one and program the board by SAM. Only the mentioned basic control boards are available with the new software! Please use the new control boards as spare part only in case of the above described behaviours. For any other reason, please use the control boards according to Service Info. The control boards will be substituted by the new versions step by step in respect of the production capacity of the supplier. Its planned to introduce the new control boards in production completely until week39 2009.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 38 of 44

Service Bulletin 4812 712 40348


AUTHOR: Ronny Schuricht Last Update: 05/16/11 VERSION: 1.0 TITLE: F23 appears, but pressure switch is ok. SUBJECT: The customer claims the failure indication F23.

REMEDIAL ACTION
Pressure switch Failure This failure code can be also generated by a defect heater or a defect drain pump or bad harness connections to heater or drain pump. To exclude the drain pump and the heater as root cause, please check: 1. Check if the drain pump is running and check for foreign objects in the lter (see F03) 2. Inverse the mains plug polarity (by turning the mains plug or by changing polarity of single connectors of the power cord on the RFI Filter => ATTENTION: unplug appliance from mains before touching the single connectors!!!) If with inversed polarity failure code remains F23, continue with checks for Pressure switch. If with inversed polarity failure code changes to F12, check for Heater failure F12. Pressure switch failure: If the CCU can not properly read the OPEN or CLOSED status of the pressure switch contacts or if the CCU detects during the wash cycle that the pressure switch contact for the wash level L1 (11-14) and the pressure switch contact for level "empty drum L0"(11-12) are CLOSED or OPEN simultanously for 10 sec., this failure will be displayed. Potential Causes Check the wiring connections between the pressure switch and the CCU (2 connectors on pressure switch and 2 connectors on CCU) Check for proper operation of the pressure switch contacts (without water: 11-14 open, 11-12 closed, with water: 11-14 closed, 11-12 open). Check the electrical resistance of the pressure switch for open and closed contacts without and with water. Start the Service program. If the problem persists the Error Code F23 will be displayed. If no issue found, check other points from hydraulic system like blocked air trap or blocked pressure switch hose (see failure F01 and F03)

If these actions do not solve the issue and all parts like pressure switch and heating element are working correctly, then exchange the control board by the new version indicated in the table below.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 39 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 40 of 44

Service Bulletin 4812 712 40320


AUTHOR: Ronny Schuricht Last Update: 03/31/09 VERSION: 1.0 TITLE: rotary program selector Domino SUBJECT: In some washing machines with Domino control unit and rotary program selector it was detected, that turning of program selector is too hard, program selection not possible or program indication is different from selected program. Related machines are of production week 10 and 11 2009.

REMEDIAL ACTION
If such a failure occurs on machines of mentioned production period, the rotary program selector has got a mechanical defect. The related control units are supplied by Bitron with production week 09 and 10 2009. They have to be exchanged according to the spare part list in the related Service Info. How to identify the related control units:

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 41 of 44

Service Bulletin 4812 712 40313


AUTHOR: Juergen Reinhardt Last Update: 11/17/09 VERSION: 1.0 TITLE: F06 randomly displayed in Domino controls

CAUSE
Sensible failure detection in drive system for safety reasons

REMEDIAL ACTION
Please check the following points:

Load: Was there bulky load in the drum or was the machine overloaded ?

Drive system: Please check the tacho generator (resistance and cable). Please guarantee a proper and tight seat of the belt on drive shaft and pulley. Please check the electrical connections between controls and motor.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 42 of 44

Service Bulletin 4812 712 40319


AUTHOR: Ronny Schurricht Last Update: 03/27/09 VERSION: 1.0 TITLE: Avoiding F13 in the eld. SUBJECT: In the eld we have a few cases of F13 caused by leakage due to water owing into the electrical contacts of door lock during nal spin.

REMEDIAL ACTION
In order to avoid water leakage in production (week 10/2009) an insulation tape was implemented, stacked on the upper part of door lock. (see the picture) The application of insulation tape by serviceman is always necessary, when water leaks between lid of machine and front panel. Insulation tape: dimensions: 9 x 2 x max. 20 mm, material: Polyethylene foam. The usage of insulation tape is a temporary solution. In order to solve this problem in the future the door lock will be modied in the critical area and a new service bulletin will be issued.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 43 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 44 of 44

Service Bulletin 4812 712 40321


AUTHOR: Ronny Schuricht Last Update: 10/14/10 VERSION: 3.0 TITLE: Drum with improved pulley xation and drum opening. SUBJECT: There were made some modications on Alliance drums in production (7.4.2009): 1. Change of hole for pulley screw in the hub from M6 to M8 to improve connection drum pulley. (LR+HR) 2. New hinge of drum door with thickness 1,8 mm (before 1,5 mm) and rivets with diameter 4 mm (before 3 mm). (HR with 210 mm door). 3. New shape of drum door for new hinge of drum. (HR with 210 mm door) Also the heating element holder (HR), is replaced by a new one with lower shape. (pls nd Service Bulletin 481271240318) Update 19.07.2010 4. Change of hole in the hub (opposite side of pulley) from M6 to M8. Machines from serial number 341029..... onwards are equipped with the new screw M8x18 and accordingly modied drum. The washer is cancelled. Update 08.10.2010 5. Substitution of LR drum 4801 111 02217 by LR drum 4801 111 02218 equipped with drum opening of the HR drum, that is more stable.

REMEDIAL ACTION
We introduced new spare parts: drum kits with pulley screw M8x23. In the case of HR also with heating element holder + screw. The drum with new hinge (1,8 mm) has got a bigger diameter. In order to avoid contact of the drum with the old heating element holder its necessary to exchange it by the new one when the drum is replaced. In LR machines it is not necessary because of enough space between drum and heating element holder. Update 19.07.2010 As spare parts the drum kits mentioned in the table below are equipped with the tting screws. Service codes remain the same like before. Update 08.10.2010 If the drum of a 5kg LR machine needs to be exchanged the LR drum with 210mm drum opening will be send as spare part. Repair is exactly the same. The drum will t without any problems.

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 45 of 44

Whirlpool EMEA

www.scc-service.com

SERVICE

Whirlpool EMEA Customer Services

8593 631 10080, 07/10/08 page 46 of 44

Service Bulletin 4812 712 40315


AUTHOR: Ronny Schurricht Last Update: 07/01/09 VERSION: 1.0 TITLE: Bearing kit does not t.

REMEDIAL ACTION
We have some claims about spare part bearing kits, that doesnt t in the tub. Reason is a material change in production that causes slightly different measures. In Alliance LR machines the new bearing kit is used since week 49/2007. In case of exchanging the bearing kits, its important to take care about the correct bearing kit according to Service Info.

Whirlpool EMEA