Valve Sizing Calculation

Customer: Fax: Contact: Item: 5 Tags: Description: Service Description: Sizing Type: Ideal Gas PETROAMAZONAS Phone: Contact: PO Number: Project: 10480 P&ID Number: 31B016-EPF-01-140B Line Number: Solving for: Cv Noise is IECAerodynamic Flow is Volumetric CASO MIN- 0 CASO MAX- 1 CASO MIN 2- 2 CASO MAX 2- 3 60.300 1228.000 793.000 120.000 0.709 0.850 0.330 14.690 0.18572 6 80 6 80 6 1.677 0.558 91.020 578.000 143.000 120.000 0.736 0.850 0.220 14.690 0.42641 6 80 6 80 6 1.424 0.558 60.300 1228.000 793.000 60.000 0.682 0.850 0.470 14.690 0.18572 6 80 6 80 6 1.677 0.558 91.020 578.000 143.000 60.000 0.700 0.850 0.290 14.690 0.42641 6 80 6 80 6 1.424 0.558

Qty: 1 PCV-9011 VER 5 6 Inch 667 ED-DVC6200 Pressure control valve Flow is Turbulent Variable Name Units Gas Temperature (T1) deg F Inlet Pressure (P1) psig Pressure Change (dP) psi Gas Flow Rate (Qg) MMscfd Pressure Drop Ratio Factor (Xt) Pressure Recovery Factor (Fl) Valve Style Modifier (Fd) Atmospheric Pressure psi Kinematic Viscosity (Nu) cSt Pipe Size Up in Pipe Schedule Up Pipe Size Down in Pipe Schedule Down Nominal Valve Diameter (dv) in Specific heats ratio (gamma) Molecular weight /Specific gravity SG

Valve/Trim Rn ft Ao in2 T2 deg F Sizing Coefficient (Cv) Dynamic Viscosity (Mu) Pipe Outside Diam. Up Pipe Outside Diam. Down Mass flow rate (w) Inlet Compressibility Factor (Z1) Whisper III Trim Level LpAeTrim1m LpAeOutlet1m LpAeValve1m LpAeValveRn Inlet fluid density (Rho1) M1 Pipe Mo Valve M2 Pipe Outlet fluid density (Rho2) Upstream Fluid Velocity (V1) Downstream Fluid Velocity (V2) Z2 Warnings

Globe/Angle 3.281 28.000 60.300 76.399 0.013 6.625 6.625 213115.729 0.824 111 < 50 111 111 4.370 0.046 0.143 0.153 1.303 74.837 250.979 1.000

Globe/Angle 3.281 28.000 91.020 238.276 0.012 6.625 6.625 213115.729 0.923 98 < 50 98 98 1.757 0.120 0.159 0.171 1.230 186.146 265.807 1.000

Globe/Angle 3.281 28.000 60.300 38.712 0.013 6.625 6.625 106557.865 0.824 107 < 50 107 107 4.370 0.023 0.071 0.077 1.303 37.418 125.490 1.000

Globe/Angle 3.281 28.000 91.020 119.880 0.012 6.625 6.625 106557.865 0.923 95 < 50 95 95 1.757 0.060 0.080 0.086 1.230 93.073 132.904 1.000

cP in in lb/h

dB(A) dB(A) dB(A) dB(A) lb/ft3 Mach Mach Mach lb/ft3 ft/s ft/s

The Sound Pressure Level, LpA, of this condition exceeds the suggested limit of 110 dBA (normalized at 1 meter with STD pipe schedule). Additional source noise attenuation is required; path treatment is not appropriate. Note: Your noise prediction may be less than 110 dBA because you input a distance greater than 1 meter, or the pipe schedule input is greater than STD.

The Sound Pressure Level, LpA, of this condition exceeds the suggested limit of 110 dBA (normalized at 1 meter with STD pipe schedule). Additional source noise attenuation is required; path treatment is not appropriate. Note: Your noise prediction may be less than 110 dBA because you input a distance greater than 1 meter, or the pipe schedule input is greater than STD.