Вы находитесь на странице: 1из 4

tELECOM

e-terragridcom TPI

Integrated teleprotection

Generation

Transmission Distribution

Markets

Telecom

Oil and Gas

Telecom

GRID

tELECOM

e-terragridcom TPI

Generation

Transmission Distribution

Markets

Telecom

Oil and Gas

Enhance your grid security without trade-offs


e-terragridcom TPI is an integrated teleprotection module for e-terragridcom T390 power line carrier
Customers critical applications must have dependable access to electricity. Reliable and independent communication between protection relays is paramount in ensuring security of service, protecting the power grid, and maintaining protection scheme operability. The e-terragridcom TPI provides an integrated Teleprotection to Power Line Carrier, that remains a 100% Power Utility controlled communication network. As an alternative to full digital communication solutions, Alstom Grid offers an innovative product for significant improvements in communication reliability in the electrical network. With its dual path communication channels, the e-terragridcom TPI can deliver maximised performance according to customer requirements, drawing the benefits of an optical digital link in parallel with the PLC link.

Communication interface redundancy and connectivity


To improve security and reliability of Teleprotection commands, the e-terragridcom TPI offers the option of digital paths concurrently to PLC thus, improving the Probability of Missing Commands (Pmc) and Transfer Time (T0). Furthermore, in response to key requests from customers, logical operations can now be applied to commands sent simultaneously on all available communication links. At the reception side, an OR function can be applied on the commands received on a different path to trip the corresponding output The output is activated by the first received command from either link.

Communication link options


The e-terragridcom TPI can be equipped with an optical SFP module for inter or intrasubstation communications, allowing direct connection of the e-terragridcom TPIs or to a multiplexer compatible with IEEE C37.94 without converter or other intermediate equipment. Also, e-terragridcom TPI connectivity can be expanded with the addition of electrical communication interfaces over V11/ X21, G703-1 64 Kbits/s and G703-6 2 MBits/s.

Modular architecture
The PLC T390 modular architecture can include up to two e-terragridcom TPI modules.

In terms of Pmc, reliability is improved by the fact that the 2 links operate in parallel Transfer time (T0) is the best of the two links

The 1U height e-terragridcom TPI module offers the largest number of inputs and outputs for an integrated Teleprotection. Each e-terragridcom TPI module is equipped with eight Inputs and 14 Heavy Duty Outputs. They are freely programmable through the Human Machine Interface (HMI) as main output, copy, or alarm. Capacity to activate directly some circuit trip coils. The e-terragridcom TPI module supports up to four commands in analogue mode, or six with priority scheme. In digital mode, eight commands are supported, to cover more protection requirements, but which can also be applied to alarms and position information.

e-terragridcom T390 Power Line Carrier

Integrated Teleprotection Module e-terragridcom TPI

e-terragridcom T390 Power Line Carrier

Optional concurent digital communication path for teleprotection command

Electrical Interface as per V11 / G703 or E1

Multi- Telecom Multiplexer Network plexer


e-terragridcom DXC or e-terragridcom e-DXC

Optical Interface as per IEEE C37.94

Max 40 ou 80W (option) SNMP Compliant Network Management Software e-terrasentinel

Customer Benefits

Modular Integrated Communication redundancy Optimized bandwidth Manageable

Transmission Line LMU Coupling Box Circuit plug and coupling capacitor Circuit plug and coupling capacitor LMU Coupling Box

tELECOM

e-terragridcom TPI

Generation

Transmission Distribution

Markets

Telecom

Oil and Gas

Teleprotection configuration and maintenance


The Teleprotection module is fully configurable through the graphical HMI of the PLC by the mean of an allocation matrix. The HMI automatically recognises the e-terragridcom TPI module(s) and the PLC, which creates time and cost savings, since additional interfaces and specialised test and commissioning tools are unnecessary. All facilities of the graphical HMI T1, such as remote configuration using the PLCs IP address are available to the e-terragridcom TPI module. This includes compatibility with network management system compliant with SNMP protocol. To cope with Cyber security concerns, e-terragridcom T390 is the first PLC equipment to offer AES encryption and this feature is also available with e-terragridcom TPI module to ensure secure information exchange between the HMI and the e-terragridcom T390.

1 TPi in QAM

1 TPi in Speech band silent mode or dual tone per channel (up to 2)

Command in the e-terragridcom T390 digital band (QAM separated or adjacent mode) 4 independent commands or 6 with priority scheme 4 / 8 / 16 KHz per band Functioning in superimposed mode 16 kHz

Analogue Modulation (separated or adjacent) 4 commands or 6 with priority scheme Silent mode (no bandwidth use) in speech band or dual tone (1800 Hz band) (RF band allocation by HMI) 2 / 2.5 / 4 KHz per band
Signalling
Speech TX Band

Signalling
Speech RX Band

QAM TX Band

e-terragridcomTPI Pilot

Pilot

e-terragridcomTPI

Pilot

4 or 8 or 16 kHz

4 or 5 or 8 kHz

Future-Proofed Design
The e-terragridcom TPI architecture is already prepared for support of future hardware developments and, similarly, the firmware is Ethernet-ready (Teleprotection applications using IEC 61850). The firmware also incorporates future options to comply with a large range of customer constraints.

Bandwidth optimisation
To benefit from the maximum ratio between transmission speed and bandwidth, the e-terragridcom TPI can transmit Teleprotection signals within the PLC digital communication stream. Since e-terragridcom TPI command signals cut the digital transmission a Fast Recovery Time algorithm allows resynchronisation of the Digital communication Link after tripping commands that can be as low as 200ms. The e-terragridcom TPI module can also work with analogue channels of 2; 2.5 or 4 kHz . Two possibilities are offered :

Power Line Medium


External Teleprotection Additional Amplier Up to 80W (Optional)

Amplier Up to 40W Telephone Telephone PABX

Processing Unit

Dedicated band to Teleprotection command for best transfer time and security Silent mode over the speech channel. At Idle state the teleprotection does not require any bandwidth. When a trip command is activated, only the channel dedicated to voice transmission can be cut depending on activation or non-activation of the boost facility

LAN Data RS232 Data V11 Data Ethernet

Optional Service Unit Up to 9

Telecom Network

Protection Relay

Integrated Teleprotection Module with Dual Communication Path (Optional)

Intertripping commands

2nd Integrated Teleprotection Module (Optional)

Multiplexer

Digital Medium

tELECOM

e-terragridcom TPI

Generation

Transmission Distribution

Markets

Telecom

Oil and Gas

Technical data

Teleprotection module for Digital Power Line Carrier e-terragridcom T390 Modular architecture upgradable by the customer Transmission up to four independent commands over e-terragridcom T390 (up to six with priority) Transmission up to eight independent commands over Digital link Command can be send simultaneously on both communication medium if available for better reliability and transfer time Commands configurable as blocking, permissive or direct tripping Optimised communication through Power Line Carrier e-terragridcom T390 Compliant with digital PLC e-terragridcom T390 communication (TP in QAM)

Integrated test tools Command forcing with loop-back function offering transfer time measurement Real transfer time and BER measurement on the digital link Cross-connection matrix for Input , Output and communication path

Power supply voltage

Operating temperature

48VDC -30% to +25%

Max relative humidity

-30C / +55C as per IEC 60068-2-1 and -2 95% at 40C as per IEC 60068-2-3 -45C < T < +70C as per IEC 60870-2-1 and -2 IEC 60255-21-1 and -2

Input and Output logical combinations with logical command capacity

Storage Temperature

Inputs ans Outputs

Mechanical Test

8 Inputs Command acquisition by voltage (24 to 250VDC) with optoelectronic decoupling 14 Heavy Duty outputs (8 N/O and 6 N/O-N/C) - up to 290VDC, 100W, Breaking capacity up to 8A* ) * at 100 VDC

Applicable Standard

IEC recommendations

Performance - 4 commands mode

European recommendations

General: follows IEC 60834-1 EMC as per CISP22 (2006) IEC 61000-6-4 IEC 61000-6-2 EN 60950

Communication Interfaces

Overhead line through Power Line Carrier e-terragridcom T390 Redundant communication interface as an option ( to be chosen among ) 64 Kbit/s with G703.1 2 Mbit/s with G703.6 From 32 to 256 Kbit/s with V11 / V35 (RS422 X24 protocol) Optical interface for direct link or IEEE C37.94 to e-terragridcom DXC or any other multiplexer with compatible interface or

Permissive Transfer Time (T0) (including PLCs treatment time):


IEEE Standard

Probability of unwanted command (Puc):


TP over Speech: T0 12 ms TP in QAM: T0 12 ms TP digital 64 Kbps: T0 6.5 ms

C37.90.1 /.2 / .3 C37.94 compatible

Physical Dimension (mm)

483 (W) * 43,6 (1U) (H) * 297 (D)

Probability of missing command (Pmc):


Analogue mode: Puc up to 10-9 Digital mode: Puc 6E E-30 Analogue mode: Up to 10-6 Digital mode: Pmc 1E E-35

Direct single mode up to 250 km Communication on single or dual fibre

For further information please contact: Alstom Grid Inc. 10865 Willows Rd. NE, Redmond WA 98052-2502, USA Tel: +1 (425) 822 6800 e-mail: telecom@alstom.com Alstom Grid Worldwide Contact Center www.alstom.com/grid/contactcentre/ Tel: +44 (0) 1785 250 070 www.alstom.com

Telecom

GRID

ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Features

Human Machine Interface

Operating Conditions

Вам также может понравиться