Engine Protection PartnerAS


Schaller Automation Service & Repair Centre

ABC handbook for all VISATRON oil mist detector users.

The 2005 catalogue.

Content:
Content Engine Protection Partner AS- Schaller Automation repair & service centre Our services The VISATRON oil mist detector systems VN 115/87 VN 116/87 VN 215/87 Technical data Dimension Terminal plan Technical data The parts on a oil mist detector Routine maintenance schedule Fault indication on LED display LED 14 blinking and ready is off LED 13 blinking and ready is off LED 12 blinking and ready is off LED 11 blinking and ready is off LED 10 blinking and ready is off LED 9 blinking and ready is off LED 8 blinking and ready is off LED 7 blinking and ready is off LED 6 blinking and ready is off LED 5 blinking and ready is off LED 4 blinking and ready is off LED 3 blinking and ready is off LED 2 blinking and ready is off LED 1 blinking and ready is off All LED are off- no light The pipe system Pipe system for VN 115/87 and VN 116/87 Pipe system for VN 215/87 The siphon block Sampling funnels Installation guide for options Installation of heating element for measuring head Installation of scavenging air set Spare part list Spare parts for VN 115/79 & VN 115/87 Spare parts for VN 116/82 & VN 116/87 Spare parts for VN 215/82 & VN 215/87 Parts in the service box Contact person/ contact information page 1 page 2 page 4 page 6 page 6 page 6 page 7 page 7 page 8 page 9 page 10 page 14 page 16 page 16 page 17 page 17 page 17 page 18 page 18 page 18 page 19 page 19 page 20 page 20 page 20 page 20 page 21 page 21 page 22 page 23 page 24 page 25 page 26 page 27 page 28 page 29 page 30

The information in this document is the property of Engine Protection Partner AS and may not be copied, or communicated to a third party, or used, for any purpose other than for which it is supplied without the express written consent of Engine Protection Partner AS

Engine Protection Partner AS (EPP)


- Schaller Automations repair and service centre
EPP is located in Bergen- Norway, and was established in 1994 by Mr. Yngve Nilsen. EPP is Schaller Automations repair and service centre and are only focussing at oil mist detector technology. This means that our customers get a high standard of knowledge to the products and the services that we present in the marked. The companies work closely together, and Schaller Automation KG is the manufacturer of the Visatron oil mist detector systems. EPP is the only company who is authorized for repairs of the Visatron oil mist detectors worldwide by Schaller Automation. In 2003, the company handled over 3.000 cases connected to sale, installations and service/ repairs worldwide. All repaired, reconditioned and new systems have 12 month warranty.

Facts about EPP:


We are the only authorized repair centre for Schaller Automation on World wide basis. We are the marked leader within repairs and service of the Visatron systems. High knowledge of oil mist detection technology. Short repair time at the oil mist detectors. Short delivery time of new systems, spare parts and services. Long warranties at our services. We are a flexible partner for our customers. We always have all types of spare parts available. Open 7 days a week24 hours. Free training courses.

We dont sell dreams- but improved technology!


In the companyprofile, everything is focused on high quality and excellent service for our customers. Since the start with repairs, we work continuously to raise the quality to new levels. EPP have always the latest and most improved technology within tools, measurement and test techniques to secure that our customers are getting their vessels running. The claim- rate for year 2003 was only 0,6 % for over 700 oil mist detector repairs. The low claimrate is a result of all the different testing procedures that all repaired parts have to pass before we can do classification in the end. How we are testing: Step 1: When we a starting to do a repair, we dismantle all parts. All electronic parts as electronic module, in- foamed electronic components in measuring head housing and valve box devices are controlled by POLAR fault locating system. From this test procedure we get a overview of which Electronic parts who have to be replaced.

Step 2: After the change of defect components, all sensor functions are calibrated after own calibration procedure.

Step 3: When calibrations, electronically and mechanically repair is done, all units have to be tested in 2 hours by a simulated computerized vibration tester.

Step 4: The last test before the repairs is finished, is the climate chamber test. This is a long time test who least in over 19 hours. The climate test is simulating extreme temperature conditions from minimum 5 and up to 70 degrees Celsius.

Our services:
Sale of new systems: Engine Protection Partner AS deliver new Visatron oil mist detectors VN 115/87 CE, VN 116/87 CE and VN 215/87 CE. All new detectors can be delivered with heating element for measuring head housing, scavenging air system and Visatron pressure regulator as standard, and the delivery time is only one day.

Sale of second- hand systems: Engine Protection Partner AS offer secondhand systems. We have a stock for VN 115/79, VN 115/87 EMC / CE, VN 116/82, VN 116/87 EMC / CE, VN 215/82 and VN 215/87 EMC / CE. All second- hand systems are delivered with heating element for measuring head housing, scavenging air system, Visatron pressure regulator and 12 mount warranty. We also sell second- hand main parts as electronic modules and measuring head housings.

Sale of spare parts: Engine Protection Partner AS guarantee that all types of spare parts are on stock at all times. The delivery time is never longer than one (1) day. Order the one day- get the parts delivered the next day.

Installations: Engine Protection Partner AS delivers complete installation kit for all three models. The installation kit consist of main pipe system, engine wall connections, sampling funnels or Siphon blocks and oil mist detector bracket. Engine Protection Partner AS has trained personnel to do the installation at customers location. Service on vessels: At Engine Protection Partner AS we have our own service engineer crew for doing service and repairs at vessels location. In the same time, all existing oil mist detector pipe systems are tested and necessary adjusted before the job is completed.

Our service department: Engine Protection Partner AS is the only authorized repair centre for Schaller Automation. We handle between 700 and 1.000 repairs yearly. All types of repairs are done by us, and it takes never longer than 4 days to get your systems finished and certificated. Our repair centre is well-known world wide for the extremely high quality and excellent service. The repair centre is open 24 hours- 7 days a week.

Service agreements: Engine Protection Partner AS offer service agreements for the marine marked. Please take contact for more specific information. Our service and technical information phone: We have 24 hours open phone where vessel crew can call directly to us regarding questions about technical information and trouble shooting. You are always welcome to take contact with us.

The VISATRON oil mist detector systems:


VISATRON VN 115/87 like all other units of the VISATRON series, continuously and simultaneously evacuate crankcase atmosphere from each crankcase compartment between two main bearings. The Types VN 115/87 and VN 116/87 use a header-suction-tube system for this purpose. The oil mist detector is positioned in the middle between two header-suction-tube sections located on the engine sides; from these sections, single-suction tubes branch off near the compartments. These tubes are considerably thinner than the header-suction tubes and they have a throttling effect. Owing to the large header-suction- tube diameter the vacuum and consequently the sample flow at each suction point remain virtually constant. The arrangement of the detector in the middle of the header-suction tube results in an optimally short sample running time in the tube system. In the detector itself the sample mixture of both header-suction-tube sections is conducted through an optical turbid metric channel. Subsequently, the oil mist is discharged together with the exhaust air from the wearresistant air jet pump. The turbidity of the crankcase atmosphere (oil mist droplets having a diameter of approx. 5 mm) is measured by optical absorption. The measuring path consists of two infrared diodes, one of them working as a transmitter and the other one as a receiver. Oil mist passing between them absorbs some of the infrared light, thereby reducing the amount of light reaching the receiver. The selected unit of measurement is % opacity [%OP]; 0% opacity means zero, turbidity, 100% OP, however, total optical absorption. VISATRON VN 116/87 as compared to the Type VN 115, is more sensitive because it has an additional differential alarm level. It compares the oil mist concentration from each side of the heeder-suction- tube section and responds if there is a difference, this being a sure sign for an overheating damage in the compartment group with the higher opacity. The differential alarm level is carried along with regard to its sensitivity relating to the 10stage adjustment of the alarm level which is also available for VN 115. For measuring the opacity differential, the sample flows of both header-suction-tube sections are fed to the turbid metric channel one after the other by closing the respective tube sections alternately by means of reed valves. The microprocessor saves both opacity values and executes the opacity comparison (damage check). In home position both valves are open. They only become operative if the compound opacity from both header-suction-tube sections exceeds the sensitive threshold for starting the damage check. This will trip an alarm if the decisive differential alarm level is being exceeded. At the same time it is indicated in which compartment group the damage has occurred.Oil mist is explosive from a concentration of 50 mg of atomized oil in 1 litre of air = 40% OP, ignition temperature of approx. 500 0 C. It is important that the opacity value exponentially depends, upon the oil mist concentration, i. e. it is already very high in case of a minor turbidity. Therefore, turbidity measurement with the header-suction-tube system can also reach a high sensitivity (e.g. 0,5% OP= 0,1 mg/l of oil mist) from a damaged compartment mixed with crankcase atmosphere from the other compartments is diluted in the header-suction tube. In case of medium speed trunk-piston engines the compartment volumes are relatively small compared with the crankcase of crosshead engines so that the oil mist has developed from an overheating damage will rapidly result in a higher concentration. VISATRON VN 215/87, operates in the same way as the Type VN 116/87 as far as the tripping of an alarm is concerned, however, it is able to additionally indicate the suction point with the highest opacity and thus the compartment in which the overheating damage has occurred. Unlike the other types, the VN 215/87 has a singlesuction-tube system, each compartment being connected by a separate tube to valve box designed for 10 suction lines.All procedures are similar to those of type VN 116/87. Normally, the compound opacity of the oil mist from all compartments will continuously be measured. If the opacity exceeds the damage check starting threshold a damage check will be executed. lf the differential alarm level is exceeded, an alarm causing the automatic stop of the machine or a speed reduction will immediately be tripped. In contrast to the type VN 116/87, a search run will be continued. By closing the valves of certain compartment groups according to an iteration procedure and by an opacity comparison, the single-suction line can finally be determined which is supplied with oil mist from the compartment in which the overheating damage has occurred. For damage indication on the detector, the position of the valve which is still left open is used for indicating the damaged compartment. In order to meet the high mechanical and electrical demands and to take account of the mostly limited space at the engine, all VISATRON oil mist detectors are constructed as packaged units by using aluminium cast, with the wear-resistant air jet jump, the vibration-isolated base plate for the metal-clad measuring unit with plug and socket connection as well as the electrical and pneumatically connections being erected on a solid cast iron plate. The suction tubes on the left and right side are connected to the valve box by two moulded rubber flanges having no threads. The use of the particularly advantageous siphon assembly likewise allows a connection of the tubes of the siphon blocks without any threads. All subassemblies including the valve box are provided with plug and socket connections and can, if necessary, be exchanged without the tubes at the engine having to be dismounted.

Technical data:
Dimension:

Terminal plan:

Technical data:
Operating voltage: 24 V DC +/- 25%, with reverse battery protection Power consumption: Maximum 3 A Electromagnetic compatibility: Wiring failures: 50 Hz to 10 kHz, 3 V eff./10 kHz to 50 kHz, 1 V eff. Electromagnetic fields: 30 kHz to 200 MHz, field strength 10 V/m, Damped oscillation: 1 MHz, 1 kV, 400 pulses per second, High- energy pulses: 0,5 joule, 5 rV, Ri= 500 Ohm. Electromagnetic fields: 30 kHz to 1 GHz with 10 V/m, Acc. to IEC 801-3 (ambient class 3, 10 V/m, 30 kHz- 16 Hz ) Fast transients ( bust ): Acc. to IEC 801-4, ( ambient class 3 ) Electrostatic discharge: Acc. to IEC 801-2 Negative pressure measured: At least 60 mm, maximum 80 mm W.G. in measuring unit Driving air for air jet pump: 0,3 to 0,5 bar Air consumption: Dependent on the number of suction points, however, max. 1 normal m3 /h Protection: IP 44 Admissible operating temperature range: 0 C to + 70 C Admissible oil mist temperature range: Maximum + 70 C. Admissible storage and transport temperature range: - 25 C to + 80 C. Humidity: Max. 90% relative humidity Vibration: Max. acc. 6,0 G. Weights: VN 115/87 = 7,5 kg. VN 116/87 = 9,4 kg. VN 215/87 = 9,6 kg.

Heating element for measuring head.

Scavenging air set block

Screw for U- tube manometer

Inspection cover/ Scavenging air set

Pipe for scavenging air set LED indicator ALARM lamp TEST lamp READY lamp Sensitivity switch LED indicator

Measuring head

Vibration plate for measuring head. Lower suspensions Screw plug

VN 115: Tube connection VN 116: Valve box device VN 215: Valve box device Oil mist pipe from engine input

Output pipe back to engine

Ejector output Ejector input Connection socket Main cable for mea. Head

Contact/ RESET house RESET button Connector for heating element

Routine maintenance schedule.


The routine maintenance schedule has to be followed as described below. The manufacturers warranty will become void if these instructions are not followed. Valid for gas operation with TPS turbo charger, stationary power plant application and marine engines.
500 Procedure 1. Procedure 2 Procedure 3. Procedure 4. Procedure 5. 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 24000 48000

x o x

x o

x o x

x o x

x o x

x o x

x o x

x o

x o x

x o x x

Procedure: Running hours


X= Overhaul/ change. O= Testing/ adjustment of system.

Procedure 1.

Change Scavenging air filter and Circlip for scavenging air filter (part no. 10042 & 10041)

Procedure 2:

Turn off the air pressure

open the inspection cover

put the 5% test glass (part no. 10039) between the infra- red sensor track (the TEST lamp will light up)

push the RESET button (LED no. 14 start to blink) close the inspection cover

fill up the u- tube manometer (part no. 10055) to the middle with slacked water

10

dismount the plug from the inspection cover

install the u- tube

turn up the pressure to 60 mm. water colum

the LED no. 14 disappears and READY lamp lights.

Procedure 3:

Open the inspection cover

clean the infrared sensor glasses with cotton stick & alcohol... close the inspection cover.

Procedure 4:

Reduce the incoming air pressure

disconnect the RESET task connector

dismount the measuring head housing

disconnect the connecting case

change the small seal

change the seal for connecting case

Remount the connector case on the base plateunscrew the vibration plate

change the vibration dampers

11

change the flexible bellows

reinstall the vibration plate to the base plate

change the measuring head seal

install the measuring head at the vibration plate open the inspection cover

change the scavenging air filter

change the seal for inspection cover

clean the infra red sensor glasses

clean the bores with cleaning needle

change the screw & seal for inspection cover close the inspection cover

unscrew the plugs at the connection case

change the plug & seal

check the heating element if it is hot

check all leaders in the main socket

Follow procedure no. 2 when setting the system back in operation!

12

Procedure 5:

Unscrew the measuring head housing with electronic modulereplace this with new exchange unit.

Send the defect OMD unit back to Engine Protection Partner AS. The measuring head and electronic module have to be re- calibrated, sensors and the main cable at the measuring head housing will may be changed.

13

Fault indication on LED- display:


Fault: LED number 14 is blinking and the ready light is off.
Follow the procedure below:

Turn off the pressure regulator

remove the plug at the inspection cover...

install the u- tube manometer

fill up water to the middle of the scaleturn up the pressure until it reaches 60 mm. at the scalethe LED 14 shall stop blinking, and the OMD shall go back to ready mode. If this does not help, do as follows..

Open the inspection coverreplace both scavenging air filter and circlips (do not clean the filters!!)close the inspection cover. If this does not help, do as follows..

Open the inspection cover

use the cleaning needle and put it into the hole at the right side

and the left side

close the inspection cover. If this does not help, do as follows.. Replace the measuring head & electronic module.

14

If this does not help, do as follows..

Remove the measuring head housing

check the seal for measuring head, If damaged, change the seal

check both flexible bellows under the vibration damp plate. If it is damaged, change the flexible bellows.

If this does not help, do as follows..

Disconnect the ejector input

carefully clean the unit with clean spray for OMD

reinstall the ejector input.

If this does not help, do as follows..

Disconnect the ejector output

carefully clean the unit with clean spray for OMD

reinstall the ejector output.

If this does not help, do as follows..

Replace measuring head housing and electronic module.

15

Fault indication on LED- display:


Fault: LED number 13 is blinking and the ready light is off.
- infrared filter clogged!

Open the inspection cover

the infrared filter glasses are dirty

clean the glasses with a cotton stick and alcohol

Close the inspection cover. If this does not help, do as follows Replace measuring head housing and electronic module.

Fault: LED number 12 is blinking and the ready light is off.


LED 12 not in use!

Push the reset button If this does not help, do as follows

Replace measuring head housing and electronic module.

16

Fault: LED number 11 is blinking and the ready light is off.


- OMD indicates that the temperature is less than 0 C around the system!
Engine compartment ventilator blows cold air into the device change blowing direction of ventilator away from the OMD or install scavenging air system (part no. 10678) and heating element for measuring head (part no. 10671). If this does not help, do as follows

Replace measuring head housing and electronic module.

Fault: LED number 10 is blinking and the ready light is off.


ambient temperature above 70 C.
Protect device against sources of heat radiation install scavenging air set. If this does not help, do as follows

Replace measuring head housing and electronic module.

Fault: LED number 9 is blinking and the ready light is off.


electronic temperature below 0 C.
Check if engine room ventilator blows air directly at the OMD device Change blowing direction of the ventilator to ensure that cold air is not directed to the OMD device. If this does not help, do as follows Install heating element for measuring head (part no. 10671) & scavenging air set (part no. 10678). If this does not help, do as follows

Replace measuring head housing and electronic module.

17

Fault: LED number 8 is blinking and the ready light is off.


electronic temperature above 70 C.
Check if heat sources radiates on the OMD deviceprotect OMD device against heat radiation, improve fresh air circulation. If this does not help, do as follows Install heating element for measuring head (part no. 10671) & scavenging air set (part no. 10678). If this does not help, do as follows

Replace measuring head housing and electronic module.

Fault: LED number 7 is blinking and the ready light is off.


RESET button defective.

Check if the reset button is blockedeliminate blocking. If this does not help, do as follows Replace measuring head housing and electronic module.

Fault: LED number 6 is blinking and the ready light is off.


not in use.

Replace measuring head housing and electronic module.

18

Fault: LED number 5 is blinking and the ready light is off.


OMD sensivity switch defective.

Replace measuring head housing and electronic module.

Fault: LED number 4 is blinking and the ready light is off.


Infrared sensor track defective.

Open the inspection cover

the infrared filter glasses are dirty

clean the glasses with a cotton stick and alcohol

Close the inspection cover. If this does not help, do as follows

Replace measuring head housing and electronic module.

19

Fault: LED number 3 & 2 is blinking and the ready light is off.
electronic module defective.

Replace measuring head housing and electronic module.

Fault: LED number 1 is blinking and the ready light is off.


electronic module defective.

Replace measuring head housing and electronic module.

Fault: All LED are dead/ no light.

Remove the reset task house

measure the voltage between pin 1 & 2 (18- 26 Vdc) remove the measuring head housing

replace the fuse (2A) If this does not help, do as follows Replace measuring head housing and electronic module.

20

The pipe system.


It is important to have a correct designed pipe system. With a wrong designed pipe system, you will get fault alarms and it may be able to result in blocked pipes. When new installing of pipe system, it is important to emphasize cleanliness during the assembly work! Clean pipelines and fastening parts before assembly. Lay pipes in a stress- free manner.

The pipe size used for VN 115/87 and VN 116/87 should be: Header 22 * 2 mm. ( i. d. 18 mm), max length: 9 meters. Suction pipes 10 * 2 mm. ( i. d. not less than 6 mm ). The pipe size used for VN 215/87 should be: Header 14 * 2 mm. ( i. d. 10 mm). All pipe laying for pipe systems without typhoon block needs to have at least a gradient of 2- 6%

Pipe systems for VN 115/87 and VN 116/87:


Descending pipe system with headers above suction points on the left side. Ascending to the device, ascending gradient 2% to 6%, without sagging, avoid oil collection. Horizontal pipe system with siphon blocks on the right side.

Installation for VN 215/87:


Descending pipe system with headers above suction points on the left side. Ascending to the device, ascending gradient 2% to 4%, without sagging, avoid oil collection. Up to 5 separate pipes on each side of the detector. Horizontal pipe system with siphon blocks on the right side.

21

The Siphon Block


The siphon block is designed to let the oil mist go through the pipe system and let the oil and oil droplets go down and back to the crankcase. The siphon blocks are made for VN 115/87, VN 116/87 and VN 215/87 systems. The design makes the installation of pipes quick and easy.

22

Sampling funnels.
If you have too much oil in the pipe system, you need to check if there is sampling funnels installed in the crankshaft room on every suction point. A sampling funnel is an oil labyrinth, where the oil droplets are filtered away, and just the oil mist is passing (see drawing to the right). It is also necessary to install sampling funnels if the pipe system does not have the 2-4 % of an angel (see drawing below). There is two different main types of sampling funnels: the short type (normally used for new engines) and long type sampling funnel (normally used for engines with age over 8 years).

1. Sampling funnel

2. Suction pipes. 3. Header pipe. 4. Drain pipe (leading the oil back to the engine).

23

Installation guide for the options.


Heating element for measuring head housing. Part no. 10671
A standard heating element is installed in all the VN/87 series, in the base plate. This heating unit might not be sufficient to cover all cases (cases of extreme humidity in the crankcase, higher water content in the lubricating oil or lower than normal ambient temperatures). The measuring head heating systems serves to heat the top of the measuring head and the crankcase gas flowing through the VN device, in order to avoid condensation of water, especially in climatic sone with high humidity or low temperatures. Condensation of water may trigger a false high oil mist alarm when small droplets of water are detected by the optical measuring track and shuts down the engine. The heating element for measuring head has 70% better effect in-front of the heating element for base plate.

Installation of the heating element:

Turn off the supply air into the OMD device

disconnect the RESET plug

remove the two screws at the top of the measuring head

Install the heating element at the top

remove the old heating element

plug the hole where the old element has been installed

use the same contact as used for the old heating elementset the RESET plug into the connector againturn up the air supply to 60 mm. water column.

24

Scavenging air set. Part no. 10678


The scavenging air system uses the air flow from the ejector input. This means that the system does not use the atmosphere outside the detector. This helps to reduce the risk of fault alarms caused by polluted air in the engine room. The system also reduces the amount of condensation flowing through the oil mist detector. The scavenging air set reduces the heat inside the measuring head housing. Installation of scavenging air system:

Turn off the supply air into the OMD device

disconnect the RESET plug

dismount the old inspection cover

install the air block on the right side of the measuring head

install the new inspection cover

Remove the old ejector input

Install the new ejector input

connect the flexible pipe into the block

close the inspection cover

reconnect the reset plug to the connector

turn up the air supply to 60 mm water column.

25

Spare parts for VN 115/87 & VN 115/79

1. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

10202. 10922. 10051. 10052. 10604. 10206. 10033. 10049. 10019. 10054. 10083. 10088. 10042. 10041.

Connecting Casing VN 115/87 Connecting casing VN 115/79 Heating element for base plate Cable clip for heating element Base plate (lower VN part) Seal Connecting socket Valve box seal Measuring head suspension button Cap seal Screw plug R Cover for measuring head Scavenging air filter Circlip for scavenging air filter

14. 14. 15. 16. 17. 18. 19. 24. 25. 26. 26. 27. 28.

10601. 10920 10023. 10018. 10022. 10208. 10209. 10084. 10085. 10603. 10921. 10043. 10087.

Measuring head for VN 115/87 Measuring head for VN 115/79 Expansion bellows Measuring head suspension top Measuring head seal Screw plug Screw plug seal Protecting cover for el. module Fastening screw for el. module Electronic module VN 115/87 Electronic module VN 115/79 Fuse 2A Fuse cap.

26

Spare parts for VN 116/87 & VN 116/82

1. 1. 2. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.

10302. 10923. 10051. 10671 10052. 10604. 10306. 10033. 10307. 10305. 10019. 10083. 10082. 10088. 10042. 10041.

Valve box VN 116/87 Valve box VN 116/82 Heating element for base plate Heating element for measuring head Cable clip Base plate (lower VN part) Oil reflux seal Connecting socket Oil mist seal Seal for valve box Measuring head suspension button Screw plug R Seal for item 10 Cover for measuring head Scavenging air filter Circlip for scavenging air filter

15. 15. 16. 17. 18. 19. 20. 21. 22. 24. 25. 26. 26. 27. 28.

10706. 10923. 10023. 10018. 10022. 10208. 10209. 10312. 10313. 10084. 10085. 10707. 10924. 10043. 10087.

Measuring head for VN 116/87 Measuring head for VN 116/82 Expansion bellows Measuring head suspension top Measuring head seal Screw plug Screw plug seal Pipe connection Seal for connecting casing Protecting cover for el. module Fastening screw for el. module Electronic module VN 116/87 Electronic module VN 116/82 Fuse 2A Fuse cap.

27

Spare parts for VN 215/87 & VN 215/82

1. 1. 2. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.

10402. 10928. 10051. 10671 10032. 10052. 10406. 10033. 10407. 10405. 10019. 10409. 10083. 10082. 10088. 10408.

Valve box VN 215/87 Valve box VN 215/82 Heating element for base plate Heating element for measuring head Base plate (lower VN part) Cable clip Oil reflux seal Connecting socket Oil mist seal Seal for valve box Measuring head suspension button Clamp plate for pipe connection Screw plug R1/4 Seal for item 11 Cover for measuring head Pipe connection left

15. 16. 17. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 26. 27. 28.

10042. 10041. 10801. 10931. 10023. 10018. 10022. 10430. 10412. 10411. 10084. 10085. 10802. 10934. 10043. 10087.

Scavenging air filter Circlip for scavenging air filter Measuring head for VN 215/87 Measuring head for VN 215/82 Expansion bellows Measuring head suspension top Measuring head seal Pipe connection- right Drain plug for pipe connection Rubber sleeve for pipe connection Protecting cover for el. module Fastening screw for el. module Electronic module VN 215/87 Electronic module VN 215/82 Fuse 2A Fuse cap.

28

Different parts in the service box

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18.

10024. 10053. 10054. 10031. 10002. 10018. 10019. 10020. 10030. 10034. 10155. 10035. 10135. 10036. 10040. 10037. 10038. 10039.

Manual Quick connection for u- tube manometer Gasket Wrench mounting of electronic module Filter for pressure regulator Suspension bottom Suspension top Flexible clamp ring for distance bolt Lower spring for suspension Lower distance bolt for suspension Oil return gasket Alcohol Cleaning needle Cotton stick Slacked water Screw driver for mounting of mea. head Screw driver for adjustm. of alarm level 5 % glass

19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36.

10041. 10042. 10023. 10043. 10406. 10044. 10407. 10412. 10411. 10045. 10156. 10047. 10157. 10048. 10049. 10050. 10409. 10046.

Circlip for fresh air filter Fresh air filter Flexible bellow Fuse 2A Oil return gasket Hexagon wrench for valve box Oil mist gasket valve box Lock plug for valve box Rubber plate for tube connection Mount piece for cigarette burner Ring box end wrench Hexagon wrench Screw drive 4 mm Pliers for mounting circlip for air filters Gasket for valve box Plastic bag Clamp plate for tube connection U- tube manometer

29

Contact information

Company name: Company address:

Engine Protection Partner AS O. J. Brocks gate 16 A- 2nd floor P. O. Box 2668 Mohlenpris 5836 Bergen- Norway (+47) 55 30 19 00 (+47) 55 30 19 01 (+47) 55 30 19 00/ (+47) 946 32 220 www.epp.no yngve@epp.no- Technical questions, spare parts orders ect. Nordea Bank Norge ASA. 6001 Aalesund- Norway NO21 6550 05 16482 NDEANOKK 6550. 05. 16482 976 683 560

Office phone: Office fax: 24 hour phone: Home page: E- mail addresses: Bank details: Bank address: IBAN code: Swift code: Account number: Org. no/ VAT number:

30