Key Benets
Flexible deployment Carrier grade Fault tolerance Enhanced QoS management Standards compliance
Carrier Grade: The EPC3000 is designed to meet environmental conditions of operators Network Operation Center. It is built on an industry standard 13U/14-slot ATCA hardware with redundant hot-swappable power supplies. The hardware supports varying degree of redundant configurations to match operators network availability targets. Fault Tolerance: The EPC3000 supports on-chassis redundancy and geographic redundancy configurations. On-chassis redundancy consists of 1+1 redundancy for the control plane and N+1 redundancy for the data plane. This redundancy scheme ensures active sessions are retained for all connected users, while user data lost is kept to a minimum by the load-balancing feature of the data plane traffic, should the chassis experiences a single blade failure. Geographic redundancy consists of a second EPC3000 located in a different geographic location as a backup EPC. Besides hardware redundancy, the EPC3000 supports primary and secondary servers for redundant Home Subscriber Server (HSS) and Policy and Charging Rules Function (PCRF).
Enhanced QoS management: The Policy and Charging Enforcement Function (PCEF) in the EPC3000 enforces Quality of Service (QoS) and manages multiple service flows as directed by the PCRF. This function allows operator to offer differential service levels based on subscriber and application priorities. Such QoS mechanism is extremely important for public safety and mission critical application where network resource is directed to the highest priority users during emergencies. Standards Compliance: The EPC3000 complies with 3GPP standards, allowing the components in the EPC3000 to interwork with other 3GPP compliant LTE eNodeB via the S1 interface, PCRF via the Gx interface and HSS via the S6a interface.
Gx
PCRF
S6a
HSS
EPC3000
S6a PCRF Gx
LTE USB UE
S1
Power Dimension
Weight Compliance Operating temperature Storage temperature Operating humidity Regulatory & compliance
EMC
nnFCC Part 15 and CISPR 22, Class B
Environment
nnGR-63-CORE criteria 69-71, 72, 73, 107-109, 110-112, 114, 115, 117, 119, 122, 123, 124, 128 nnETSI ETS 300 019-1-1: storage class 1.2 for non-temp-controlled locations nnETSI ETS 300 019-1-2: transp. class 2.3 except for rain requirement nnETSI ETS 300 019-1-3: prA1 earthquake response spectrum, /A1 operating class 3.1 for temp-con-
trolled locations
nnETSI ETS 300 753: acoustic noise for env. class 3.1 non-ofce environments
USA Headquarters 90 New Montgomery Street, Suite 315 San Francisco, CA 94105 United States +1 415 430 1350 UK R&D Center Unit 7, Greenways Business Park Chippenham, Wiltshire SN15 1BN United Kingdom +44 (0) 1249 800 100 Website: www.gd-broadband.com
2012 General Dynamics. All rights reserved.
GDB-EPC3000-1-0812