Installation
Make sure an electrical outlet is within 3 feet of where the
D-Series panel will mount. If there are no outlets, one will need Features
to be added.
– Wall mounted white powder coated back panel and cover.
Install and level Z-Bracket with 1/4” x 2-1/2” lag screw to – Easy access to all components.
studs. Make sure the Z-Bracket is the correct size for the – Pre-wired circulators and controls.
given D-Series panel. Incorrect Z-Brackets may interfere with – Simple CAT 5 jump wiring to connect panels.
cover placement. – Single union connection between panels.
– Integrated leveling system.
Hang the D-Series panel on the Z-Bracket. Optional lag screws – Z-Bracket for simplified mounting.
may be added to the bottom of the panel, further securing the
panel to the wall. Hang cover from top down.
Specifications
To purge a Mix panel make sure all necessary isolation valves
Supply Voltage . . . . . . . . . . . . . . 120 Volts
are closed and all purge valves are open. Proceed until all
Circulator Type. . . . . . . . . . . . . . . Watts Radiant 15-58
zones are filled and purged. Open all purge ball valves and cap
. . . . . . . . . . . . . . . . . . . . . . Taco 007
the drain. Make sure all isolation ball valves are open for
. . . . . . . . . . . . . . . . . . . . . . Bell and Gossett NRF-22
normal operation.
Electrical . . . . . . . . . . . . . . . . . . . Relay and CAT 5 Connection
Mix Valve Cv . . . . . . . . . . . . . . . . 3.2 gpm
Refer to the installation manual for further details.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials
without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Hydronex D-Series DMix 3 zone panel. DMix Hybrid series are
available from 1 to 3 zones.
Product Options
DMix Valve Panel, 1 Taco 007 Pump DMixV1TA007 81005830 28” x 31.5”
DMix Valve Panel, 2 Taco 007 Pumps DMixV2TA007 81005831 40” x 31.5”
DMix Valve Panel, 3 Taco 007 Pumps DMixV3TA007 81005832 40” x 31.5”
DMix Valve Panel, 1 Bell & Gossett NRF-22 Pump DMixV1BGNRF22 81005833 28” x 31.5”
DMix Valve Panel, 2 Bell & Gossett NRF-22 Pumps DMixV2BGNRF22 81005834 40” x 31.5”