Вы находитесь на странице: 1из 12

Manpower requirement Manpower Description (OPERATION) Management Staff Shift Incharge Desk engineer Operation Management Total LMS

Turbine Boiler AHP BOP DM Plant Operation LMS Total Operator 1st Class Mill, Feeder & Boiler Turbine BOP Electrician DM operator & Pump Operation Operator Total 1 2 2 2 1 2 10 4 8 8 8 4 8 40 8 16 16 8 4 8 60 12 24 24 8 4 8 80 1 1 2 1 1 6 4 4 8 4 4 24 8 8 8 4 4 32 12 12 8 4 4 40 1 4 5 4 16 20 8 32 40 12 48 60 Per Control room Per Shift Per control room 3 shift ( x 4) For 4 Units For 6 Units

r requirement Available Further required for 4 Units by Dec 13 6 15 21 4 7 7 4 4 26 8 12 13 3 4 2 42

2 17 19 4 1 1 0 0 6 0 4 3 5 0 6 18

Manpower requirement Manpower Description CHP & Silo Management Management Staff Shift incharge G. Shift CHP & Silo Management total LMS General shift- CHP Shift CHP Silo Ash management Shift CHP & Silo LMS Total Operators 4 2 1 7 0 4 8 4 16 0 4 8 4 16 0 4 8 4 16 0 1 4 5 4 4 8 4 4 8 4 4 8 Per Control room Per Shift Per control room 3 shift ( x 4) For 4 Units For 6 Units

ement Further required Available for 4 Units by Dec 13 3 0 3 2 4 0 6 13 1 4 5 2 4 4 10 -13

Manpower requirement Manpower Description (Mechanical Maintenace) Management Staff Pressure Parts Rotary FD, ID, PA & APH Mills ESP, Duct & Dampers Turbine TG Auxiliaries DMPT, PT & RW CWTP, CWPH & CT Compressors, AC, Fire Fighting & HVAC Shift Engineers Mech. Maintenance Management Total LMS Pressure Parts Rotary FD, ID, PA & APH Mills ESP, Duct & Dampers Turbine TG Auxiliaries DM Plant, PT & RW CWTP, CWPH & CT Compressors, AC, Fire Fighting & HVAC Supervisors 4 nos per shift Mechanical LMS Total Technicans (8 nos per shift) 4 4 8 4 2 4 2 2 2 4 36 6 4 4 8 4 2 4 2 2 2 16 48 24 4 4 8 4 2 4 2 2 2 16 48 24 4 4 8 4 2 4 2 2 2 24 56 28 2 2 2 2 2 2 1 1 1 2 17 2 2 2 2 2 2 1 1 1 8 23 2 2 2 2 2 2 1 1 1 8 23 3 3 3 3 3 3 1 1 1 12 33 Per Control room Per Shift Per control room 3 shift ( x 4) For 4 Units For 6 Units

These persons will be needed in main plant O & M subsequent to project

ement Further required Available for 4 Units by Dec 13 2 2 2 2 2 2 0 0 3 6 9 0 2 14 4 4 8 4 2 4 2 2 2 1 1 0 15 47 24

Manpower Description (C&I) Management Staff HOD Section Incharge Area-1 Area-2 Common Area C&I Management Staff LMS Area-1 Area-2 Common Area LMS TOTAL TECHNICIAN Area-1 Area-2 Common Area TOTAL

Per Shift (A, B, C) 1 1 0 2 1 1 1 3 2 2 1 5

General Shift 1 2 2 2 1 8 3 3 2 8 2 2 0 4

Manpower requirement Total Tot 6 units Available (4 units) (same as 4u) 1 2 6 6 1 16 7 7 6 20 10 10 4 24 1 2 6 6 1 16 7 7 6 20 10 10 4 24 1 2 4 4 1 12 5 6

NOTE: 1: Two persons will be outsourced for miscellaneous package (telephone, PA system etc.) maintenance. 2: MOV maintenance shall be limited to Limit Switch setting by C&I. All other jobs like motor maintenance, Actuator Gearbox & Valve maintenace to be done by respective dept. 3: Three Lead Person (incl. HOD) required and exists is not shown in this table.

t Plan by Oct 1 7 10 Plan by Feb-14 4 8 8

maintenance,

Manpower Description Electrical Management Staff HOD Section Incharge Area-1(BTG) Area-2(BOP) Area-3(S/Y,Line & Trafo) TOTAL LMS Area-1(BTG) Area-2(BOP) Area-3(S/Y,Line & Trafo) Illumination Electrical Repair Shop & Laboratory TOTAL TECHNICIAN Area-1(BTG) Area-2(BOP) Area-3(S/Y,Line & Trafo) Electrical Repair Shop & Laboratory TOTAL

Per Shift (A, B, C) 1 1 0 2 2 2 1 0 0 5 2 2 1 0 5

General Shift 1 2 6 4 1 14 6 4 1 1 1 13 6 4 1 1 12

Manpower Requirement Total Tot 6 units Available (4 units) (same as 4u) 1 2 10 8 1 22 14 12 5 1 1 33 14 12 5 1 32 1 2 10 8 1 22 14 12 5 1 1 33 14 12 5 1 32 1 2 10 5 1 19 2 2 3 1 0 8 11 5 2 0 18

NOTE: Out sourcing of following jobs is to be done: a)Major jobs for 220kV Switch Yard & Lines, Power & Distribution transformers,HT/LT Motor's bearing replacement,Regular i b)Annual Overhauling Jobs.

nt Plan by Oct 3 5 4 2 0 0 11 3 5 2 0 10 Plan by Feb-14 0 7 6 0 0 1 14 0 2 1 1 4

bearing replacement,Regular illumination maintenance,Generator etc.

Manpower requirement Manpower Description (OPERATION) Management Staff Operation Management Total CHP & Silo Management total Mech. Maintenance Management Total C&I Management Total Electrical Maintenance Total TOTAL LMS Operation LMS Total CHP & Silo LMS Total Mechanical LMS Total C&I LMS TOTAL Ekectricak Maintence Total TOTAL Operator Operation Operator Total CHP Operators Mechanical Shift Technicans C&I Tedchnicians total Electrical Technician TotalL TOTAL Per Control room Per Shift 5 5 17 2 2 Per control room 3 shift ( x 4) 20 8 23 8 14 For 4 Units (same for 5 Units) 40 8 23 16 22

31
6 7 36 3 5

73
24 16 48 8 13

109
32 16 48 20 33

57
10 0 6 5 5

109
40 0 24 4 12

149
60 0 24 24 32

26

80

140

wer requirement For 6 Units Further required Available for 4 Units by Dec 13 19 3 9 12 19 21 5 14 4 3

60 8 33 16 22

139
40 16 56 20 33

62
6 6 1 5 8

47
26 10 47 15 11

165
80 0 28 24 32

26
18 13 0 6 18

109
42 -13 24 18 14

164

55

85

Вам также может понравиться