Professional in: Fire protection in building

Light hazard

Technological innovations which provide solutions for fire protection of life and property in: According to UNE-EN-12.845: Colleges, schools and offices with low fire load and low flammability, which are not unitary surfaces over 126 m 2 with a fire resistance of less than 30 minutes. Penitentiary Institutions. According to NFPA-13: Educational centers, hospitals, nursing homes, hotels, libraries, museums, offices, homes, restaurants, theaters and auditoriums (excluding scenarios), churches, clubs and penitentiary institutions.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:56

Pgina 2

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:56

Pgina 3

INDEX

Page FIXED SYSTEMS: AUTOMATIC SPRINKLERS Automatic sprinkler.....................................................................................1 Valve....................................................................................................................4 FIRE SERVICE EQUIPMENTS Hydrant..............................................................................................................5 FHCs and IPF..................................................................................................6

SYSTEM COMPONENTS Pump control valve....................................................................................7 Valves..................................................................................................................8 Electric switches and monitoring devices.....................................9 PIPE, COUPLINGS AND SUPPORT CPVC pipe....................................................................................................10 Steel pipe.......................................................................................................11 Stainless Steel..............................................................................................12

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 4

AUTOMATIC SPRINKLERS

Fixed Systems: Automatic Sprinklers

DH-80 SPRINKLER

Mximum coverage: 8.5m x 4.3m Response: Quick K=116 Design norm: NFPA 13 Technical Bulletin: 003

NEW COVERAGE HORIZONTAL SIDEWALL 8.4 M WIDTH AND 4.2 M LENGHT Install 1 sprinkler instead of 2
INSTALLATION
CRITERIA:

- Distance between sprinkler maximum 8.4 m minimum 3.6 m - Distance opposite wall 4,2 m - Deflector to ceiling dimensions are 100 mm minimum and 305 mm maximum. - Smooth and flat roofs - K= 116

8.4 m

Hallways Decks Balconies Corridors Roofs Room up to 28 (8.5 m) long

STYLES

AVAILABLE:

FINISHINGS:
- White, chrome, other colors available

- Horizontal sidewall - Horizontal sidewall recessed - Horizontal sidewall concealed


Consult technical bulletin n 003

www.anber gl obe.com

4.2 m

LONG &

NARROW APPLICATIONS:

4.2 m

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 5

AUTOMATIC SPRINKLERS

Fixed Systems: Automatics Sprinklers

DECORATIVES
INCH CONCEALED
Response: Standard and quick K (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable up to 1" Technical bulletin: GL 5653 / GL 5606

AGC, AGC-QR CONCEALED


Response: Standard and quick K (metric): 40, 60, 80 Design norm: UNE-EN12.845 NFPA 13 Coverplate: ajustable por rosca Technical bulletin: 121/154

SWC56 SIDEWALL CONCEALED


Response: Standard and quick K (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable by thread Technical bulletin: 168

GL CONCEALED
Response: Standard and quick K (metric): 39, 59, 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable three position Technical bulletin: GL 2854 / GL2804

MILLENIUM
Response: Quick K (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Technical bulletin: GL 5650

ZX-1
Response: Quick K (metric): 80 Design norm: UNE-EN 12.845 NFPA 13 Technical bulletin: 134

BASIC SIDEWALL RECESSED


Response: Standard and quick K (metric): 39, 59, 80, 111, 116 Design norm: UNE-EN 12.845 NFPA 13 Technical bulletin: GL 5651 / GL 2801

BASIC PENDENT RECESSED


Response: Standard and quick K (metric): 39, 59, 80, 111, 116 Design norm: UNE-EN 12.845 NFPA 13 Technical bulletin: GL 5651 / GL 2801

INSTITUTIONAL
XL.EC AND XL PENDENT
Coverage1: 4.9 m x 4.9 mK K (metric): 80 Response: Quick Design norm: NFPA 13 Hoja tcnica: 113

XL.EC AND XL PENDENT


Coverage1: 4.9 m x 4.9 mK K (metric): 80 Response: Quick Design norm: NFPA 13 Hoja tcnica: 113

1 Maximum coverage area in the cases considered in design norm.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 6

AUTOMATIC SPRINKLERS

Fixed Systems: Automatics Sprinklers

EXTENDED COVERAGE
DH 56
Max. Coverage1: 8,5 m x 3 m Respons: Rpida K (metric): 80 Design norm: NFPA 13 Technical bulletin: 015

DH 80
Max. Coverage1: 8.5 m x 4.3 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: 003

HORIZONTAL SIDEWALL
Max. Coverage1: 4.87 m x 6.7 m Respons: Standard and Quick K (metric): 80 and 116 Design norm: NFPA 13 Technical bulletin: GL5628, GL8128

PENDENT
Max. Coverage1: 6.09 m x 6.09 m Respons: Quick K (metric): 80, 116 Design norm: NFPA 13 Technical bulletin: 148, GL 8109

JL 112 UPRIGHT
Max. Coverage1: 37.2 m2 Respons: Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 173

JL 112 PENDENT
Max. Coverage1: 37.2 m2 Respons: Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 172

F1FR EPEC PENDENT


Max. Coverage1: 17.64 m2 Respons: Quick Design norm: UNE-EN 12.845 with TB222 LPC Technical bulletin: 012

HORIZONTAL SIDEWALL CONCEALED


Max. Coverage1: 4.87 m x 6.09 m Respons: Quick K (metric): 80, 116 Design norm: NFPA 13 Technical bulletin: GL 5613

DH 56 CONCEALED
Max. Coverage1: 8.5 m x 3 m Respons: Quick K (metric): 80 Design norm: NFPA 13 Technical bulletin: 015

DH 80 CONCEALED
Max. Coverage1: 8.5 m x 4.3 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: 003

G4 XLO CONCEALED
Max. Coverage1: 6.09 m x 6.09 m Respons: Standard and Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 144

PENDENT CONCEALED
Max. Coverage1: 6.09 m x 6.09 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: GL 8104

1 Maximum coverage area in the cases considered in design norm.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 7

VALVE

Fixed Systems: Automatic Sprinklers

WET
MODEL H1, H2, H3
Operating principle: water / water Use: Schools, hospitals, homes, offices, restaurants, theaters and premises that have similar conditions and use. Norm: UNE-EN 12845, NFPA 13 AND FM Diameters: 2 , 3, 4, 6 and 8 Description: Pipes contain water. When the sprinkler is opened by the action of the fire, water is discharge inmediatly

RISER CHECK: CONTROL OF PLANT AND AREA

Operating principle: water / water Use: Buildings in height with more than one plant or area for each valve Norm: UNE-EN 12845, NFPA 13 and FM Diameters: 1 8 Description: The pipes contain water. They allow monitoring, draining, purge and control the installation of sprinklers in more than one plant for each checkpoint

PREACTION SYSTEM
AGC-X MODEL
Operating principle: water / detection and/or compressed air Use: Buildings where the effect of water can cause as much damage as the fire such as museums, libraries and penitentiary institutions Norm: UNE-EN 12845, NFPA 13 AND FM Diameters: 2, 2 , 3, 4 and 6 Description: When the detection system send a sign, valve open and water flood the pipes emiting an alarm. Water keep into pipes until sprinkler open by the efect of fire.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 8

HYDRANT

Service Fire Extintion

WET PILLAR FIRE HYDRANT


CALIFORNIA
Use: Buildings located in places without frost problems, traffic or space on sidewalks. Flow rate sparehead: 500 l/min Max. Distance: 80 m real route K factor: outlet of 70 mm K 1745 and outlet of 100 mm K 3780 (K only hydrant) Design characteristic: The hydrant is equipped with globes valves, which have separate opening and closing for each outlet built into the hydrant body.

DRY PILLAR FIRE HYDRANT


SUPERTIFON, TIFON, TIFON PLUS
Use: Buildings located in places with problem of frost and heavy traffic. Flow rate sparehead: 500 l/min Max. Distance: 80 m real route K factor: outlet 70 mm K1900 and outlet 100 mm K 3300 (K only hydrant) Design characteristic: Frost-free System: This model is equipped with a device which AUTOMATICALLY DRAINS any water in the standpipe when the main valve is closed, preventing frost damage. Break-resistant System: The hydrant is also equipped with a device similar to a fuse which, in the case of a heavy blow, will break where the body is connected to the barrel, releasing the main valve which will automatically emain closed because of the water pressure, thereby ensuring full tightness without the need for auxiliart components.

UNDERGROUND FIRE HYDRANT


Use: Buildings located in places with space problems on sidewalks. Flow rate sparehead: 500 l/min Max. Distance: 80 m real route K factor: outlet 70 mm K1830 and outlet 100 mm K 3080 Design characteristic: The locking mechanism is built on non-ferrous materials, thus impeding that with the passage of time, is leaking due to corrosion. They incorporate an optional automatic drainage system, which prevents damage by frost.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 9

FHCs AND IPF

Fire Service Equipments

25 FHCs

Hose: semi-rigid 25 mm Use: Have water spearhead, it does not need to be spreaded in its entirety for use Minimum flow rate: 100 l/min Maximum distance: 25 real route K factor: 42

25 FHCs with 45 mm connector

Hose: semi-rigid 25 mm Use: Allows the adjustment of additional hose 45 Minimun flow rate: 200 l/min Maximum distance: 25 real route

RISER CHECK VALVE

Use: Backstop, discharge, control and monitoring of water network of FHCs Diameter: 1 1/2 to 8 Norm: NFPA 13 D/ 13R

DRY RISER (IPF 39, 40 AND 41)

IPF 39: Outlet in floor with 2 connections 1 1 / 2 "(45 mm) IPF 40: Outlet in floor with 2 connections 1 (45mm). Valve severing 3 "(80 mm) IPF 41: Connection at facade with 2 connections 2 (70 mm) Use: water free-instalation, incorporated into the building to support the fire department services. It is used by connecting the fire department vehicle to the facade inlet in order to supply water to the floor outlets.

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 10

CONTROL PRESSURE VALVE

System Components

PRESSURE REDUCING VALVE


MODEL FP 720 AND FP420
Use: Contributing to establish pressure zones, maintaining the hydraulic balance in the water distribution systems against fire. They are responsible for reducing the pressure highest input to a predetermined constant pressure and lower output. -Line-pressure driven Independent operation -Hydraulic actuation Close drip tight under static pressure High flow capacity -Operation through pilot easy calibration -Free obstacles in the single cavity Free flow -Pre-assembled trim -In-line serviceable Easy maintenance

PUMP CONTROL VALVE


MODEL FP430, FP730 AND FP436
Use: The pressure control pressure valves of the pump is activated by the hydraulic pressure in the line and are designed to protect the pumping systems and water distribution. -Hydraulically powered valve design Quick reaction Closes drip tight time after time Eliminates jamming problems -Advanced pilot system Adjustable closung speed Eliminates pressure surges -System pilot dual parallel -One-piece molded single moving part no maintenance required -Free obstacles in the single cavity Free flow -In-line serviceable Easy maintenance

LEVEL CONTROL VALVE


MODEL FP450
Use: Water level control of tank in protection against FIRE instalation. -Line-pressure driven Independent operation -Balanced rolling-diaphragm High flow capacity Very low opening & closing pressure requirement -Dynamically restrained actuation Non-slam closing -Free obstacles in the single cavity Free flow -External installation Easy access to valve & flota Less wear and tear -In-line serviceable Easy maintenance

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 11

VALVES

System Components

RESILIENT SEATED OS&Y GATE VALVE / RESILIENT SEATED NRS GATE VALVE
OS&Y NRS

Use: Open and close water flow Approvals: FM and UL PN: 16 bar Connection: Flanged

VERTICAL AND HORIZONTAL INDICATOR POST

Use: Show open/close shut-off valve position Approvals: FM, UL

BUTTERFLY VALVE

Use: Open and close water flow with gear operator, indicator switch and position switch. Approvals: FM, UL PN: from 12 to 21 bar Connection: Threaded, grooved and flanged

CHECK VALVE
CHECK VALVE GROOVED

Use: They prevent reverse flow preventing emptying facilities Approvals: FM, UL, ULC PN: 12 bar Connection: Threaded and flanged

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 12

ELECTRIC SWITCHES AND MONITORING DEVICES

System Components

WATERFLOW SWITCHES

Use: Electric Monitoring of waterflow and/or airflow in the instalation Approvals: UL, FM, LPCB, CE

PRESSURE SWITCHES

Use: Electric Monitoring of waterflow and/or airflow in the instalation Approvals: UL, FM, LPC, CE

TAMPER SUPERVISORY SWITCHES

Use: Show valve position Approvals: UL, FM, CE

WATER TANK SWITCHES

Use: Show level of water in the tank Approvals: UL

COMPRESSOR

Use: Pressurization of the sprinkler network in dry pipe system and preaction system Types: Coaxial, belt, diesel

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 13

CPVC PIPE

Pipe, Couplings and Support

CPVC PIPE
-Resistant to aggressive environments and condensation -Pipes from 3 / 4 "to 3" -Post chlorinated poly vinyl chloride -Its lightness eases the assembly and eliminates the need for qualified staff -Minimizing redundant in works -Better coefficient of friction (lower pressure drop), C = 140

FITTINGS & COUPLINGS

Use: Union of CPVC pipe. Tees. Sprinkler tee PN: 12 bar Working temperature: +2C + 66 C Description: provide flexibility for the installation. No need for qualified personnel. Eliminate welding work

PIPE HANGERS AND SUPPORT

Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Description: Designed to support pipe in case of fire.

www.anber gl obe.com

10

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 14

STEEL PIPE

Pipe, Couplings and Support

STEEL PIPE PREFABRICATION


-Any pipe: any standard, from 1 up to 12 -Any finish available -Process standardization and improving quality product. -Easy assembly and it is not needed professional labour force. -Minimizing redundant in works -Planning of a priori assembly. -Sizing and calculation based on real installation

GROOVED FITTINGS & COUPLINGS


Description: It consists of a tube corrugated helical flexible of stainless steel, one outlet, a reducer, a bar and two support fixing reducer to the support guides of false ceiling ensuring a perfect position for automatic sprinklers. Approvals: UL / FM

GROOVED FITTINGS & COUPLINGS

Use: joint of steel pipe, Tee, sprinkler tee. PN: 21 bar Working temperature: -60 + 110 C Description: Give flexibility to instalation. Without profesional labour force. Eliminate welding

PIPE HANGERS AND SUPPORT

Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Approvals: FM, UL Description: Designed to support pipe in case of fire.

11

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 15

STAINLESS STEEL PIPE

Pipe, Couplings and Support

STAINLESS STEEL PIPE

- Resistant to aggressive environments and condensation - Pipe 10 mm to 108 mm - Stainless steel AISI 304 or AISI 316 - It facilitates the assembly to be slight and there was no need for the qualified personnel - Minimizing redundant in works - Better coefficient of friction (lower pressure drop), C = 140

FITTINGS & COUPLINGS

Use: Union of stainless steel pipe. Tees. Sprinkler tee PN: 20 bar Working temperature: -30 C +110 C Description: provide flexibility for the installation. No need for qualified personnel. Eliminate welding work

PIPE HANGERS AND SUPPORT

Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Approvals: FM, UL Description: Designed to support pipe in case of fire.

www.anber gl obe.com

12

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 16

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 17

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 18

www.anber gl obe.com

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 19

RIESGO LIGERO:RIESGO LIGERO

24/6/08

14:57

Pgina 20

w w w . a n b e r g l o b e . c o m