Light hazard
Technological innovations which provide solutions for fire protection of life and property in: According to UNE-EN-12.845: Colleges, schools and offices with low fire load and low flammability, which are not unitary surfaces over 126 m 2 with a fire resistance of less than 30 minutes. Penitentiary Institutions. According to NFPA-13: Educational centers, hospitals, nursing homes, hotels, libraries, museums, offices, homes, restaurants, theaters and auditoriums (excluding scenarios), churches, clubs and penitentiary institutions.
www.anber gl obe.com
24/6/08
14:56
Pgina 2
24/6/08
14:56
Pgina 3
INDEX
Page FIXED SYSTEMS: AUTOMATIC SPRINKLERS Automatic sprinkler.....................................................................................1 Valve....................................................................................................................4 FIRE SERVICE EQUIPMENTS Hydrant..............................................................................................................5 FHCs and IPF..................................................................................................6
SYSTEM COMPONENTS Pump control valve....................................................................................7 Valves..................................................................................................................8 Electric switches and monitoring devices.....................................9 PIPE, COUPLINGS AND SUPPORT CPVC pipe....................................................................................................10 Steel pipe.......................................................................................................11 Stainless Steel..............................................................................................12
www.anber gl obe.com
24/6/08
14:57
Pgina 4
AUTOMATIC SPRINKLERS
DH-80 SPRINKLER
Mximum coverage: 8.5m x 4.3m Response: Quick K=116 Design norm: NFPA 13 Technical Bulletin: 003
NEW COVERAGE HORIZONTAL SIDEWALL 8.4 M WIDTH AND 4.2 M LENGHT Install 1 sprinkler instead of 2
INSTALLATION
CRITERIA:
- Distance between sprinkler maximum 8.4 m minimum 3.6 m - Distance opposite wall 4,2 m - Deflector to ceiling dimensions are 100 mm minimum and 305 mm maximum. - Smooth and flat roofs - K= 116
8.4 m
STYLES
AVAILABLE:
FINISHINGS:
- White, chrome, other colors available
www.anber gl obe.com
4.2 m
LONG &
NARROW APPLICATIONS:
4.2 m
24/6/08
14:57
Pgina 5
AUTOMATIC SPRINKLERS
DECORATIVES
INCH CONCEALED
Response: Standard and quick K (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable up to 1" Technical bulletin: GL 5653 / GL 5606
GL CONCEALED
Response: Standard and quick K (metric): 39, 59, 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable three position Technical bulletin: GL 2854 / GL2804
MILLENIUM
Response: Quick K (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Technical bulletin: GL 5650
ZX-1
Response: Quick K (metric): 80 Design norm: UNE-EN 12.845 NFPA 13 Technical bulletin: 134
INSTITUTIONAL
XL.EC AND XL PENDENT
Coverage1: 4.9 m x 4.9 mK K (metric): 80 Response: Quick Design norm: NFPA 13 Hoja tcnica: 113
www.anber gl obe.com
24/6/08
14:57
Pgina 6
AUTOMATIC SPRINKLERS
EXTENDED COVERAGE
DH 56
Max. Coverage1: 8,5 m x 3 m Respons: Rpida K (metric): 80 Design norm: NFPA 13 Technical bulletin: 015
DH 80
Max. Coverage1: 8.5 m x 4.3 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: 003
HORIZONTAL SIDEWALL
Max. Coverage1: 4.87 m x 6.7 m Respons: Standard and Quick K (metric): 80 and 116 Design norm: NFPA 13 Technical bulletin: GL5628, GL8128
PENDENT
Max. Coverage1: 6.09 m x 6.09 m Respons: Quick K (metric): 80, 116 Design norm: NFPA 13 Technical bulletin: 148, GL 8109
JL 112 UPRIGHT
Max. Coverage1: 37.2 m2 Respons: Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 173
JL 112 PENDENT
Max. Coverage1: 37.2 m2 Respons: Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 172
DH 56 CONCEALED
Max. Coverage1: 8.5 m x 3 m Respons: Quick K (metric): 80 Design norm: NFPA 13 Technical bulletin: 015
DH 80 CONCEALED
Max. Coverage1: 8.5 m x 4.3 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: 003
G4 XLO CONCEALED
Max. Coverage1: 6.09 m x 6.09 m Respons: Standard and Quick K (metric): 160 Design norm: NFPA 13 Technical bulletin: 144
PENDENT CONCEALED
Max. Coverage1: 6.09 m x 6.09 m Respons: Quick K (metric): 116 Design norm: NFPA 13 Technical bulletin: GL 8104
www.anber gl obe.com
24/6/08
14:57
Pgina 7
VALVE
WET
MODEL H1, H2, H3
Operating principle: water / water Use: Schools, hospitals, homes, offices, restaurants, theaters and premises that have similar conditions and use. Norm: UNE-EN 12845, NFPA 13 AND FM Diameters: 2 , 3, 4, 6 and 8 Description: Pipes contain water. When the sprinkler is opened by the action of the fire, water is discharge inmediatly
Operating principle: water / water Use: Buildings in height with more than one plant or area for each valve Norm: UNE-EN 12845, NFPA 13 and FM Diameters: 1 8 Description: The pipes contain water. They allow monitoring, draining, purge and control the installation of sprinklers in more than one plant for each checkpoint
PREACTION SYSTEM
AGC-X MODEL
Operating principle: water / detection and/or compressed air Use: Buildings where the effect of water can cause as much damage as the fire such as museums, libraries and penitentiary institutions Norm: UNE-EN 12845, NFPA 13 AND FM Diameters: 2, 2 , 3, 4 and 6 Description: When the detection system send a sign, valve open and water flood the pipes emiting an alarm. Water keep into pipes until sprinkler open by the efect of fire.
www.anber gl obe.com
24/6/08
14:57
Pgina 8
HYDRANT
www.anber gl obe.com
24/6/08
14:57
Pgina 9
25 FHCs
Hose: semi-rigid 25 mm Use: Have water spearhead, it does not need to be spreaded in its entirety for use Minimum flow rate: 100 l/min Maximum distance: 25 real route K factor: 42
Hose: semi-rigid 25 mm Use: Allows the adjustment of additional hose 45 Minimun flow rate: 200 l/min Maximum distance: 25 real route
Use: Backstop, discharge, control and monitoring of water network of FHCs Diameter: 1 1/2 to 8 Norm: NFPA 13 D/ 13R
IPF 39: Outlet in floor with 2 connections 1 1 / 2 "(45 mm) IPF 40: Outlet in floor with 2 connections 1 (45mm). Valve severing 3 "(80 mm) IPF 41: Connection at facade with 2 connections 2 (70 mm) Use: water free-instalation, incorporated into the building to support the fire department services. It is used by connecting the fire department vehicle to the facade inlet in order to supply water to the floor outlets.
www.anber gl obe.com
24/6/08
14:57
Pgina 10
System Components
www.anber gl obe.com
24/6/08
14:57
Pgina 11
VALVES
System Components
RESILIENT SEATED OS&Y GATE VALVE / RESILIENT SEATED NRS GATE VALVE
OS&Y NRS
Use: Open and close water flow Approvals: FM and UL PN: 16 bar Connection: Flanged
BUTTERFLY VALVE
Use: Open and close water flow with gear operator, indicator switch and position switch. Approvals: FM, UL PN: from 12 to 21 bar Connection: Threaded, grooved and flanged
CHECK VALVE
CHECK VALVE GROOVED
Use: They prevent reverse flow preventing emptying facilities Approvals: FM, UL, ULC PN: 12 bar Connection: Threaded and flanged
www.anber gl obe.com
24/6/08
14:57
Pgina 12
System Components
WATERFLOW SWITCHES
Use: Electric Monitoring of waterflow and/or airflow in the instalation Approvals: UL, FM, LPCB, CE
PRESSURE SWITCHES
Use: Electric Monitoring of waterflow and/or airflow in the instalation Approvals: UL, FM, LPC, CE
COMPRESSOR
Use: Pressurization of the sprinkler network in dry pipe system and preaction system Types: Coaxial, belt, diesel
www.anber gl obe.com
24/6/08
14:57
Pgina 13
CPVC PIPE
CPVC PIPE
-Resistant to aggressive environments and condensation -Pipes from 3 / 4 "to 3" -Post chlorinated poly vinyl chloride -Its lightness eases the assembly and eliminates the need for qualified staff -Minimizing redundant in works -Better coefficient of friction (lower pressure drop), C = 140
Use: Union of CPVC pipe. Tees. Sprinkler tee PN: 12 bar Working temperature: +2C + 66 C Description: provide flexibility for the installation. No need for qualified personnel. Eliminate welding work
Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Description: Designed to support pipe in case of fire.
www.anber gl obe.com
10
24/6/08
14:57
Pgina 14
STEEL PIPE
Use: joint of steel pipe, Tee, sprinkler tee. PN: 21 bar Working temperature: -60 + 110 C Description: Give flexibility to instalation. Without profesional labour force. Eliminate welding
Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Approvals: FM, UL Description: Designed to support pipe in case of fire.
11
www.anber gl obe.com
24/6/08
14:57
Pgina 15
- Resistant to aggressive environments and condensation - Pipe 10 mm to 108 mm - Stainless steel AISI 304 or AISI 316 - It facilitates the assembly to be slight and there was no need for the qualified personnel - Minimizing redundant in works - Better coefficient of friction (lower pressure drop), C = 140
Use: Union of stainless steel pipe. Tees. Sprinkler tee PN: 20 bar Working temperature: -30 C +110 C Description: provide flexibility for the installation. No need for qualified personnel. Eliminate welding work
Use: Clamp and hanger / fastener accesories / Channel / Fixing accessories / Complements Approvals: FM, UL Description: Designed to support pipe in case of fire.
www.anber gl obe.com
12
24/6/08
14:57
Pgina 16
www.anber gl obe.com
24/6/08
14:57
Pgina 17
www.anber gl obe.com
24/6/08
14:57
Pgina 18
www.anber gl obe.com
24/6/08
14:57
Pgina 19
24/6/08
14:57
Pgina 20
w w w . a n b e r g l o b e . c o m
Avda. de las Flores, 13 -15 - P.E. El Molino 28970 Humanes de Madrid - Madrid (Espaa) Tel.: (+34) 91 606 37 11 Fax: (+34) 91 690 95 61 e-mail: ventas@anber.es