Вы находитесь на странице: 1из 4

7 216 /7 220 F IE L D S E R V IC E V e r.1.0 M a r.

2004

M AIN T E N AN C E

4.3.4

Imagin g Un it (IU)

NO T E When the developer is to be changed, it is necessary that toner in the R ecy cled T oner R ecy cling Duct and T oner Convey ing Duct be fed into the Developer M ix ing Chamber. T o do that, remove the T oner Bottle and run AT DC Auto Adjust twice. 2-46
(1 ) Remo v al o f th e Imagin g Un it (IU)

1. O p e n th e F ro n t Do o r. 2. O p e n th e R ig h t Do o r. 3. R e m o v e tw o s c re w s a n d th e IU .

4035D021AA

P r e c a u tio n s fo r In s ta lla tio n o f th e IU When installing the IU , use care not to damage the P C Drum. Before attempting to install the IU , be sure to fully open the R ight Door. T ak e care that, if the IU is installed with the R ight Door lock ed halfway , it may interfere with the transfer roller. When inserting the IU , do that slowly and, when y ou are sure that the drum gear contacts the mating part, push the IU all the way into position. If this step is done all at once, the drum gear could be damaged.

(2)

Disassemb ly o f th e IU 1. R e m o v e o n e s c re w in th e re a r o f th e IU a n d re m o v e th e h a rn e s s c o v e r.

4035D022AA

1-15

MAINTENANCE

7216/7220 FIELD SERVICE Ver.1.0 Mar. 2004

2. Remove two screws in the rear of the IU.

4035D023AA

3. Remove two screws at the front of the IU.

4035D024AA

4. W iden flaps on b oth ends (mark ed with A in the


A

photo on the left) of the Dru m Assy in the direction of the arrow and tu rn to tak e off the DevelopA

ing Assy .

4035D025AA

5. Unplu g one connector of the Main Erase.

4035D026AA

1-16

7216/7220 FIELD SERVICE Ver.1.0 Mar. 2004

MAINTENANCE

(3)

Removal of the PC Drum 1. Remove two screws and the pivot shaft.

4035D027AA

2. Remove the P C Drum.

NOTES Protect the PC Drum that has been removed with a protective cloth. If the PC Drum has been replaced with a new one, apply a coat of toner to the surface of the new PC Drum. 1-21
4035D028AA

(4)

Removal of the Ozone Filter 1. Remove two screws and the Main Erase.

4035D029AB

2. Remove the Oz one Filter.

4035D030AA

1-17

MAINTENANCE

7216/7220 FIELD SERVICE Ver.1.0 Mar. 2004

(5)

Removal of the PC Drum Charge Corona A ssy 1. Remove the PC Drum. 2. Remove the Main Erase.
3 4

3. Turn the holder in the rear in the direction of the arrow to remove it from the side bracket. 4. Slide out the PC Drum Charge Corona in the direction of the arrow.

4035D031AB

(6)

Removal of the Cleaning Blade

1. Remove the PC Drum Charge Corona Assy. 2. Remove three screws and the Cleaning Blade.

4035D032AA

NOTES When securing the Cleaning Blade, tighten screws in the order of one on one edge, one at the center, and one on the other edge. When the Cleaning Blade has been replaced, apply a coat of toner to the surface of the PC Drum. 1-21

(7 )

Cleaning of the PC Drum Pap er S ep arator Fingers 1. Using a soft cloth dampened with alcohol, wipe the five Paper Separator Fingers clean of dirt.

4035D033AA

1-18

Вам также может понравиться